Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
2.
Eur Heart J Cardiovasc Imaging ; 20(12): 1395-1406, 2019 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-31220240

RESUMEN

AIMS: To investigate valve sizing and the haemodynamic relevance of the predicted left ventricular outflow tract (LVOT) in patients with mitral annular calcification (MAC) undergoing transatrial transcatheter valve implantation (THV). METHODS AND RESULTS: In total, 21 patients undergoing transatrial THV, multiplanar reconstruction (MPR), maximum intensity projection (MIP), and cubic spline interpolation (CSI) were compared for MA sizing during diastole. In addition, predicted neo-LVOT areas were measured in 18 patients and correlated with the post-procedural haemodynamic dimensions. The procedure was successful in all patients (100%). Concomitant aortic valve replacement was performed in eight patients (43%) (AVR group). Sizing using MPR and MIP yielded comparable results in terms of area, perimeter, and diameter, whereas the dimensions obtained with CSI were systematically smaller. The simulated mean systolic neo-LVOT area was 133.4 ± 64.2 mm2 with an anticipated relative LVOT area reduction (neo-LVOT area/LVOT area × 100) of 59.3 ± 14.7%. The systolic relative LVOT area reduction, but not the absolute neo-LVOT area, was found to predict the peak (r = 0.69; P = 0.002) and mean (r = 0.65; P = 0.004) post-operative aortic gradient in the overall population as well as separately in the AVR (peak: r = 0.91; P = 0.002/mean: r = 0.85; P = 0.002) and no-AVR (peak: r = 0.89; P = 0.003/mean: r = 0.72; P = 0.008) groups. CONCLUSION: In patients with severe MAC undergoing transatrial transcatheter valve implantation, MPR, and MIP yielded comparable annular dimensions, while values obtained with CSI tended to be systematically smaller. Mitral annular area and the average annular diameter appear to be reliable parameters for valve selection. Simulated relative LVOT reduction was found to predict the post-procedural aortic gradients.


Asunto(s)
Estenosis de la Válvula Aórtica , Enfermedades de las Válvulas Cardíacas , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Cateterismo Cardíaco , Enfermedades de las Válvulas Cardíacas/diagnóstico por imagen , Enfermedades de las Válvulas Cardíacas/cirugía , Humanos , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Resultado del Tratamiento
3.
J Thorac Cardiovasc Surg ; 156(1): 132-142, 2018 07.
Artículo en Inglés | MEDLINE | ID: mdl-29627180

RESUMEN

OBJECTIVE: To assess the outcomes of transatrial implantation of a transcatheter heart valve (THV) for the treatment of mitral valve disease with severe mitral annular calcification (MAC). METHODS: Implantation of a balloon-expandable THV was performed on cardiopulmonary bypass via left atrial exposure in patients considered at risk for left ventricular outflow tract obstruction. The anterior mitral valve leaflet was systematically resected and pledgeted sutures were placed to enhance stability and reduce paravalvular leak. RESULTS: Twenty-six consecutive symptomatic patients with severe MAC (mean age, 78 ± 7 years; 92% female; mean Society of Thoracic Surgeons score, 9.4 ± 4.8) were included at 6 different centers. Two patients (8%) received an Edwards Sapien XT (Edwards Lifesciences, Irvine, Calif), and 24 (92%) an Edwards Sapien 3 bioprosthesis (Edwards Lifesciences). Concomitant aortic valve replacement was performed in 11 patients. Technical success according to the criteria of the Mitral Valve Academic Research Consortium was achieved in all patients. The mean transmitral gradient decreased from 10 ± 5 to 4 ± 2 mm Hg (P < .001) with trace or mild regurgitation in all patients. An elevated mean transaortic gradient (30 mm Hg) was observed in 1 patient (4%). Five patients died during hospital stay (19%) and 2 additional between discharge and 30 days (30-day mortality: 27%). Sustained functional improvement was observed in the remaining patients. CONCLUSIONS: Transatrial implantation of a THV for the treatment of MAC is associated with high technical success despite unfavorable anatomy. In this early experience of very high surgical risk patients, 30-day all-cause mortality was high. Patients at particular risk appear to be those with chronic kidney disease requiring multiple valve surgery.


Asunto(s)
Calcinosis/cirugía , Cateterismo Cardíaco/métodos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Insuficiencia de la Válvula Mitral/cirugía , Estenosis de la Válvula Mitral/cirugía , Válvula Mitral/cirugía , Anciano , Anciano de 80 o más Años , Valvuloplastia con Balón , Calcinosis/diagnóstico por imagen , Calcinosis/mortalidad , Calcinosis/fisiopatología , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/instrumentación , Cateterismo Cardíaco/mortalidad , Ecocardiografía Tridimensional , Ecocardiografía Transesofágica , Femenino , Prótesis Valvulares Cardíacas , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Hemodinámica , Mortalidad Hospitalaria , Humanos , Masculino , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/fisiopatología , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/mortalidad , Insuficiencia de la Válvula Mitral/fisiopatología , Estenosis de la Válvula Mitral/diagnóstico por imagen , Estenosis de la Válvula Mitral/mortalidad , Estenosis de la Válvula Mitral/fisiopatología , Complicaciones Posoperatorias/mortalidad , Recuperación de la Función , Medición de Riesgo , Factores de Riesgo , Índice de Severidad de la Enfermedad , Técnicas de Sutura , Factores de Tiempo , Tomografía Computarizada por Rayos X , Resultado del Tratamiento , Estados Unidos
4.
Heart Rhythm ; 11(1): 39-45, 2014 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-24184028

RESUMEN

BACKGROUND: Ablation technology has been introduced to replace the surgical incisions of the Cox-Maze procedure in order to simplify the operation. However, the efficacy of these ablation devices has not been prospectively evaluated. OBJECTIVE: The purpose of this study was to examine the efficacy and safety of irrigated unipolar and bipolar radiofrequency ablation for the treatment of persistent and long-standing persistent atrial fibrillation (AF) during concomitant cardiac surgical procedures. METHODS: Between May 2007 and July 2011, 150 consecutive patients were enrolled at 15 U.S. centers. Patients were followed for 6 to 9 months, at which time a 24-hour Holter recording and echocardiogram were obtained. Recurrent AF was defined as any atrial tachyarrhythmia (ATA) lasting over 30 seconds on the Holter monitor. The safety end-point was the percent of patients who suffered a major adverse event within 30 days of surgery. All patients underwent a biatrial Cox-Maze lesion set. RESULTS: Operative mortality was 4%, and there were 4 (3%) 30-day major adverse events. Overall freedom from ATAs was 66%, with 53% of patients free from ATAs and also off antiarrhythmic drugs at 6 to 9 months. Increased left atrial diameter, shorter total ablation time, and an increasing number of concomitant procedures were associated with recurrent AF (P <.05). CONCLUSION: Irrigated radiofrequency ablation for treatment of AF during cardiac surgery was associated with a low complication rate. No device-related complications occurred. The Cox-Maze lesion set was effective at restoring sinus rhythm and had higher success rates in patients with smaller left atrial diameters and longer ablation times.


Asunto(s)
Fibrilación Atrial/cirugía , Procedimientos Quirúrgicos Cardíacos , Ablación por Catéter/métodos , Sistema de Conducción Cardíaco/cirugía , Anciano , Fibrilación Atrial/complicaciones , Fibrilación Atrial/fisiopatología , Ablación por Catéter/mortalidad , Ecocardiografía , Electrocardiografía Ambulatoria , Femenino , Estudios de Seguimiento , Sistema de Conducción Cardíaco/fisiopatología , Humanos , Masculino , Estudios Prospectivos , Tasa de Supervivencia/tendencias , Irrigación Terapéutica , Factores de Tiempo , Resultado del Tratamiento , Estados Unidos/epidemiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...