Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Support Care Cancer ; 30(10): 8377-8389, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-35513755

RESUMEN

INTRODUCTION: Despite reduction of xerostomia with intensity-modulated compared to conformal X-ray radiotherapy, radiation-induced dental complications continue to occur. Proton therapy is promising in head and neck cancers to further reduce radiation-induced side-effects, but the optimal dental management has not been defined. MATERIAL AND METHODS: Dental management before proton therapy was assessed compared to intensity-modulated radiotherapy based on a bicentric experience, a literature review and illustrative cases. RESULTS: Preserved teeth frequently contain metallic dental restorations (amalgams, crowns, implants). Metals blur CT images, introducing errors in tumour and organ contour during radiotherapy planning. Due to their physical interactions with matter, protons are more sensitive than photons to tissue composition. The composition of restorative materials is rarely documented during radiotherapy planning, introducing dose errors. Manual artefact recontouring, metal artefact-reduction CT algorithms, dual or multi-energy CT and appropriate dose calculation algorithms insufficiently compensate for contour and dose errors during proton therapy. Physical uncertainties may be associated with lower tumour control probability and more side-effects after proton therapy. Metal-induced errors should be quantified and removal of metal restorations discussed on a case by case basis between dental care specialists, radiation oncologists and physicists. Metallic amalgams can be replaced with water-equivalent materials and crowns temporarily removed depending on rehabilitation potential, dental condition and cost. Implants might contraindicate proton therapy if they are in the proton beam path. CONCLUSION: Metallic restorations may more severely affect proton than photon radiotherapy quality. Personalized dental care prior to proton therapy requires multidisciplinary assessment of metal-induced errors before choice of conservation/removal of dental metals and optimal radiotherapy.


Asunto(s)
Atención Odontológica , Neoplasias de Cabeza y Cuello , Neoplasias de Cabeza y Cuello/radioterapia , Humanos , Metales , Terapia de Protones/efectos adversos , Traumatismos por Radiación , Radioterapia de Intensidad Modulada/efectos adversos , Agua
2.
Radiat Oncol ; 17(1): 23, 2022 Feb 04.
Artículo en Inglés | MEDLINE | ID: mdl-35120547

RESUMEN

BACKGROUND: To develop an auxiliary GPU-accelerated proton therapy (PT) dose and LETd engine for the IBA Proteus®ONE PT system. A pediatric low-grade glioma case study is reported using FRoG during clinical practice, highlighting potential treatment planning insights using variable RBE dose (DvRBE) and LETd as indicators for clinical decision making in PT. METHODS: The physics engine for FRoG has been modified for compatibility with Proteus®ONE PT centers. Subsequently, FRoG was installed and commissioned at NPTC. Dosimetric validation was performed against measurements and the clinical TPS, RayStation (RS-MC). A head patient cohort previously treated at NPTC was collected and FRoG forward calculations were compared against RS-MC for evaluation of 3D-Γ analysis and dose volume histogram (DVH) results. Currently, treatment design at NPTC is supported with fast variable RBE and LETd calculation and is reported in a representative case for pediatric low-grade glioma. RESULTS: Simple dosimetric tests against measurements of iso-energy layers and spread-out Bragg Peaks in water verified accuracy of FRoG and RS-MC. Among the patient cohort, average 3D-Γ applying 2%/2 mm, 3%/1.5 mm and 5%/1 mm were > 97%. DVH metrics for targets and OARs between FRoG and RayStation were in good agreement, with ∆D50,CTV and ∆D2,OAR both ⪅1%. The pediatric case report demonstrated implications of different beam arrangements on DvRBE and LETd distributions. From initial planning in RayStation sharing identical optimization constraints, FRoG analysis led to plan selection of the most conservative approach, i.e., minimized DvRBE,max and LETd,max in OARs, to avoid optical system toxicity effects (i.e., vision loss). CONCLUSION: An auxiliary dose calculation system was successfully integrated into the clinical workflow at a Proteus®ONE IBA facility, in excellent agreement with measurements and RS-MC. FRoG may lead to further insight on DvRBE and LETd implications to help clinical decision making, better understand unexpected toxicities and establish novel clinical procedures with metrics currently absent from the standard clinical TPS.


Asunto(s)
Glioma del Nervio Óptico/radioterapia , Terapia de Protones/métodos , Niño , Humanos , Dosificación Radioterapéutica
3.
Front Oncol ; 11: 673886, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34211847

RESUMEN

PURPOSE: Proton therapy (PT) can be a good option to achieve tumor control while reducing the probability of radiation induced toxicities compared to X-ray-based radiotherapy. However, there are still uncertainties about the effects of PT on the organs in direct contact with the irradiated volume. The aim of this prospective series was to report 6-month follow-up of clinical and functional optic neuropathy rates of patients treated by proton therapy using a standardized comprehensive optic examination. METHODS AND MATERIALS: Standardized ophthalmological examinations were performed to analyze subclinical anomalies in a systematic way before treatment and 6 months after the end of proton therapy with: Automatic visual field, Visual evoked potential (VEP) and optic coherence of tomography (OCT). RESULTS: From October 2018 to July 2020 we analyzed 81 eyes. No significant differences were found in the analysis of the clinical examination of visual functions by the radiation oncologist. However, considering VEP, the impairment was statistically significant for both fibers explored at 30'angle (p:0.007) and 60'angle (p <0.001). In patients with toxicity, the distance of the target volume from the optical pathways was more important with a p-value for 30'VEP at 0.035 and for 60'VEP at 0.039. CONCLUSIONS: These results confirm uncertainties concerning relative biological effectiveness of proton therapy, linear energy transfer appears to be more inhomogeneous especially in areas close to the target volumes. The follow-up of patients after proton therapy is not an easy process to set up but it is necessary to improve our knowledges about the biological effects of proton therapy in real life. Our study which will continue during the coming years, suggests that follow-up with in-depth examinations such as VEP as a biomarker could improve the detection of early abnormalities.

4.
Radiother Oncol ; 147: 30-39, 2020 06.
Artículo en Inglés | MEDLINE | ID: mdl-32224315

RESUMEN

The quality of radiation therapy has been shown to significantly influence the outcomes for head and neck squamous cell carcinoma (HNSCC) patients. The results of dosimetric studies suggest that intensity-modulated proton therapy (IMPT) could be of added value for HNSCC by being more effective than intensity-modulated (photon) radiation therapy (IMRT) for reducing side effects of radiation therapy. However, the physical properties of protons make IMPT more sensitive than photons to planning uncertainties. This could potentially have a negative effect on the quality of IMPT planning and delivery. For this review, the three French proton therapy centers collaborated to evaluate the differences between IMRT and IMPT. The review explored the effects of these uncertainties and their management for developing a robust and optimized IMPT treatment delivery plan to achieve clinical outcomes that are superior to those for IMRT. We also provide practical suggestions for the management of HNSCC carcinoma with IMPT. Because metallic dental implants can increase range uncertainties (3-10%), patient preparation for IMPT may require more systematic removal of in-field alien material than is done for IMRT. Multi-energy CT may be an alternative to calculate more accurately the dose distribution. The practical aspects that we describe are essential to guarantee optimal quality in radiation therapy in both model-based and randomized clinical trials.


Asunto(s)
Neoplasias de Cabeza y Cuello , Terapia de Protones , Radioterapia de Intensidad Modulada , Neoplasias de Cabeza y Cuello/radioterapia , Humanos , Terapia de Protones/efectos adversos , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador , Radioterapia de Intensidad Modulada/efectos adversos , Carcinoma de Células Escamosas de Cabeza y Cuello/radioterapia
5.
Phys Med ; 32(5): 664-70, 2016 May.
Artículo en Inglés | MEDLINE | ID: mdl-27132030

RESUMEN

PURPOSE: Static beam intensity-modulated-radiation-therapy (IMRT) and/or Volumetric-Modulated-Arc-Therapy (VMAT) are now available in many regional radiotherapy departments. The aim of this multi-institutional audit was to design a new methodology based on radiochromic films to perform an independent quality control. METHODS: A set of data were sent to all participating centres for two clinical localizations: prostate and Head and Neck (H&N) cancers. The agreement between calculations and measurements was verified in the Octavius phantom (PTW) by point measurements using ionization chambers and by 2D measurements using EBT3 radiochromic films. Due to uncertainties in the whole procedure, criteria were set to 5% and 3% in local dose and 3mm in distance excluding doses lower than 10% of the maximum doses. No normalization point or area was used for the quantitative analysis. RESULTS: 13 radiotherapy centres participated in this audit involving 28 plans (12 IMRT, 16 VMAT). For point measurements, mean errors were -0.18±1.54% and 0.00±1.58% for prostate and H&N cases respectively. For 2D measurements with 5%/3mm criteria, gamma map analysis showed a pixel pass rate higher than 95% for prostate and H&N. Mean gamma index was lower than 0.4 for prostate and 0.5 for H&N. Both techniques yielded similar results. CONCLUSION: This study showed the feasibility of an independent quality control by peers for conventional IMRT and VMAT. Results from all participating centres were found to be in good agreement. This regional study demonstrated the feasibility of our new methodology based on radiochromic films without dose normalization on a specific point.


Asunto(s)
Neoplasias de Cabeza y Cuello/radioterapia , Neoplasias de la Próstata/radioterapia , Radioterapia de Intensidad Modulada/métodos , Radioterapia/métodos , Calibración , Dosimetría por Película , Humanos , Procesamiento de Imagen Asistido por Computador , Masculino , Fantasmas de Imagen , Control de Calidad , Radiometría , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador/métodos , Rotación
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...