Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros












Base de datos
Asunto principal
Intervalo de año de publicación
1.
Sci Prog ; 107(3): 368504241274583, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39196592

RESUMEN

BACKGROUND: Epistaxis is a recurring cause for referral to emergency departments. Its management can be complex; hence, it is critical to provide appropriate support to Otolaryngology-Head and Neck Surgery (OHNS) residents to develop clinical reasoning skills to manage such cases. Learning-by-Concordance (LbC) is a recently developed educational tool that encourages learners to think through simulated clinical scenarios. A panel of ENTs provides insightful feedback to residents, reflecting a diversity of opinions about practice. Our study aimed to assess LbC's feasibility and perceived value for training OHNS residents in epistaxis management. METHODS: In this qualitative study, three OHNS surgeons, including two faculty members and one resident, wrote the LbC scenarios. The LbC tool was made available to participants through an online platform. A panel of four OHNS faculty provided feedback on answers to LbC questions. Otolaryngology-Head and Neck Surgery residents participated and provided their opinion on the value of this educational tool through an online questionnaire. RESULTS: A total of 10 one-hour sessions were required to create and upload the training tool. To provide insightful feedback embedded in the learning tool, the four panelists needed 60 min each. Of the 37 participating residents, 25 (68%) completed the training. Overall satisfaction was high: 88% appreciated the training method, and 92% wanted to use this type of training again. Most residents felt the training enabled them to improve their clinical reasoning when encountering a patient with epistaxis (92%) and their knowledge about epistaxis (96%). CONCLUSION: Findings suggest that OHNS residents could benefit from clinical reasoning exercises with panelist feedback using the LbC approach for clinical presentations that require complex approaches to manage conditions such as epistaxis.


Asunto(s)
Epistaxis , Epistaxis/terapia , Humanos , Proyectos Piloto , Otolaringología/educación , Internado y Residencia , Competencia Clínica , Retroalimentación , Encuestas y Cuestionarios , Aprendizaje
2.
Front Surg ; 8: 740935, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34692763

RESUMEN

Background: Endoscopy during middle ear surgery is advantageous for better exploration of middle ear structures. However, using an endoscope has some weaknesses as surgical gestures are performed with one hand. This may trouble surgeons accustomed to using two-handed surgery, and may affect accuracy. A robot-based holder may combine the benefits from endoscopic exposure with a two-handed technique. The purpose of this study was to assess the safety and value of an endoscope held by a teleoperated system. Patients and Methods: A case series of 37 consecutive patients operated using endoscopic exposure with robot-based assistance was analyzed retrospectively. The RobOtol® system (Collin, France) was teleoperated as an endoscope holder in combination with a microscope. The following data were collected: patient characteristics, etiology, procedure type, complications, mean air and bone conduction thresholds, and speech performance at 3 months postoperatively. Patients had type I (myringoplasty), II (partial ossiculoplasty), and III (total ossiculoplasty) tympanoplasties in 15, 14, and 4 cases, respectively. Three patients had partial petrosectomies for cholesteatomas extending to the petrous apex. Finally, one case underwent resection of a tympanic paraganglioma. Ambulatory procedures were performed in 25 of the 37 patients (68%). Results: Complete healing with no perforation of the tympanic membrane was noted postoperatively in all patients. No complications relating to robotic manipulation occurred during surgery or postoperatively. The mean air conduction gain was 3.8 ± 12.6 dB for type I (n = 15), 7.9 ± 11.4 dB for type II (n = 14), and -0.9 ± 10.8 for type III tympanoplasties (n = 4), and the postoperative air-bone conduction gap was 13.8 ± 13.3 dB for type I, 19.7 ± 11.7 dB for type II and 31.6 ± 13.0 dB for type III tympanoplasty. They was no relapse of cholesteatoma or paraganglioma during the short follow-up period (<1 year). Conclusion: This study indicates that robot-assisted endoscopy is a safe and trustworthy tool for several categories of middle ear procedures. It combines the benefits of endoscopic exposure with a two-handed technique in middle ear surgery. It can be used as a standalone tool for pathology limited to the middle ear cleft or in combination with a microscope in lesions extending to the mastoid or petrous apex.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...