Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Echocardiography ; 41(8): e15888, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-39042643

RESUMEN

BACKGROUND: Device-related thrombosis (DRT) is a common finding after left atrial appendage closure (LAAC) and is associated with worse outcomes. As women are underrepresented in clinical studies, further understanding of sex differences in DRT patients is warranted. METHODS AND RESULTS: This sub-analysis from the EUROC-DRT-registry compromises 176 patients with diagnosis of DRT after LAAC. Women, who accounted for 34.7% (61/176) of patients, were older (78.0 ± 6.7 vs. 74.9 ± 9.1 years, p = .06) with lower rates of comorbidities. While DRT was detected significantly later in women (173 ± 267 vs. 127 ± 192 days, p = .01), anticoagulation therapy was escalated similarly, mainly with initiation of novel oral anticoagulant (NOAC), vitamin K antagonist (VKA) or heparin. DRT resolution was achieved in 67.5% (27/40) of women and in 75.0% (54/72) of men (p = .40). In the remaining cases, an intensification/switch of anticoagulation was conducted in 50.% (9/18) of men and in 41.7% (5/12) of women. Final resolution was achieved in 72.5% (29/40) cases in women, and in 81.9% (59/72) cases in men (p = .24). Women were followed-up for a similar time as men (779 ± 520 vs. 908 ± 687 days, p = .51). Kaplan-Meier analysis revealed no difference in mortality rates in women (Hazard Ratio [HR]: 1.73, 95%-Confidence interval [95%-CI]: .68-4.37, p = .25) and no differences in stroke (HR: .83, 95%-CI: .30-2.32, p = .72) within 2 years after LAAC. CONCLUSION: Evaluation of risk factors and outcome revealed no differences between men and women, with DRT in women being diagnosed significantly later. Women should be monitored closely to assess for DRT formation/resolution. Treatment strategies appear to be equally effective.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Sistema de Registros , Trombosis , Humanos , Femenino , Masculino , Apéndice Atrial/cirugía , Anciano , Trombosis/etiología , Fibrilación Atrial/cirugía , Factores Sexuales , Anticoagulantes/uso terapéutico , Factores de Riesgo , Complicaciones Posoperatorias , Dispositivo Oclusor Septal , Resultado del Tratamiento , Ecocardiografía Transesofágica/métodos , Europa (Continente)/epidemiología , Cierre del Apéndice Auricular Izquierdo
2.
Clin Res Cardiol ; 112(12): 1790-1799, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37294311

RESUMEN

BACKGROUND: Device-related thrombus (DRT) after left atrial appendage closure (LAAC) is associated with adverse outcomes, i.e. ischemic stroke or systemic embolism (SE). Data on predictors of stroke/SE in the context of DRT are limited. AIMS: This study aimed to identify predisposing factors for stroke/SE in DRT patients. In addition, the temporal connection of stroke/SE to DRT diagnosis was analyzed. METHODS: The EUROC-DRT registry included 176 patients, in whom DRT after LAAC were diagnosed. Patients with symptomatic DRT, defined as stroke/SE in the context of DRT diagnosis, were compared against patients with non-symptomatic DRT. Baseline characteristics, anti-thrombotic regimens, device position, and timing of stroke/SE were compared. RESULTS: Stroke/SE occurred in 25/176 (14.2%) patients diagnosed with DRT (symptomatic DRT). Stroke/SE occurred after a median of 198 days (IQR 37-558) after LAAC. In 45.8% stroke/SE occurred within one month before/after DRT diagnosis (DRT-related stroke). Patients with symptomatic DRT had lower left ventricular ejection fractions (50.0 ± 9.1% vs. 54.2 ± 11.0%, p = 0.03) and higher rates of non-paroxysmal atrial fibrillation (84.0% vs. 64.9%, p = 0.06). Other baseline parameters and device positions were not different. Most ischemic events occurred among patients with single antiplatelet therapy (50%), however, stroke/SE was also observed under dual antiplatelet therapy (25%) or oral anticoagulation (20%). CONCLUSION: Stroke/SE are documented in 14.2% and occur both in close temporal relation to the DRT finding and chronologically independently therefrom. Identification of risk factors remains cumbersome, putting all DRT patients at substantial risk for stroke/SE. Further studies are necessary to minimize the risk of DRT and ischemic events.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Accidente Cerebrovascular , Trombosis , Humanos , Resultado del Tratamiento , Fibrilación Atrial/complicaciones , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/epidemiología , Trombosis/diagnóstico , Trombosis/epidemiología , Trombosis/etiología , Accidente Cerebrovascular/diagnóstico , Accidente Cerebrovascular/epidemiología , Accidente Cerebrovascular/etiología , Sistema de Registros , Apéndice Atrial/diagnóstico por imagen
3.
Clin Res Cardiol ; 111(11): 1276-1285, 2022 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-35849156

RESUMEN

BACKGROUND: Data on Device-related Thrombus (DRT) after left atrial appendage closure (LAAC) remain scarce. This study aimed to investigate risk factors for DRT from centers reporting to the EUROC-DRT registry. METHODS: We included 537 patients (112 with DRT and 425 without DRT) who had undergone LAAC between 12/2008 and 04/2019. Baseline and implantation characteristics, anti-thrombotic treatment and clinical outcomes were compared between both groups in uni- and multivariate analyses. Additional propensity-score matching (PSM) was conducted to focus on the role of implantation characteristics. RESULTS: Patients with DRT showed higher rates of previous stroke/transient ischemic attack (TIA) (49.1% vs. 34.7%, p < 0.01), spontaneous echocardiographic contrast (SEC) (44.9% vs. 27.7%, p < 0.01) and lower left atrial appendage (LAA) peak emptying velocity (35.4 ± 18.5 vs. 42.4 ± 18.0 cm/s, p = 0.02). Occluders implanted in DRT patients were larger (25.5 ± 3.8 vs. 24.6 ± 3.5 mm, p = 0.03) and implanted deeper in the LAA (mean depth: 7.6 ± 4.7 vs. 5.7 ± 4.7 mm, p < 0.01). Coverage of the appendage ostium was achieved less often in DRT patients (69.5% vs. 81.5%, p < 0.01), while DRT patients were less frequently on oral anticoagulation (7.1% vs. 16.7%, p < 0.01). Multivariate analysis identified age, prior stroke/TIA and SEC as independent risk factors for DRT. After PSM, implantation depth was found to be predictive. Rates of stroke/TIA were higher in DRT patients (13.5% vs. 3.8%, Hazard Ratio: 4.21 [95%-confidence interval: 1.88-9.49], p < 0.01). CONCLUSIONS: DRT after LAAC is associated with adverse outcome and appears to be of multifactorial origin, depending on patient characteristics, anticoagulation regimen and device position.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Ataque Isquémico Transitorio , Accidente Cerebrovascular , Trombosis , Humanos , Apéndice Atrial/diagnóstico por imagen , Apéndice Atrial/cirugía , Fibrilación Atrial/complicaciones , Fibrilación Atrial/cirugía , Resultado del Tratamiento , Trombosis/diagnóstico , Trombosis/epidemiología , Trombosis/etiología , Accidente Cerebrovascular/diagnóstico , Accidente Cerebrovascular/epidemiología , Accidente Cerebrovascular/etiología , Factores de Riesgo , Ecocardiografía , Sistema de Registros , Anticoagulantes/uso terapéutico
4.
Heart Rhythm ; 19(6): 917-926, 2022 06.
Artículo en Inglés | MEDLINE | ID: mdl-35181483

RESUMEN

BACKGROUND: The new-generation WATCHMAN FLX (Boston Scientific) device for left atrial appendage occlusion has been modified in various aspects to improve procedural results. No comparison of the WATCHMAN FLX device with the previous WATCHMAN device is available. OBJECTIVE: We aimed to compare procedural results with WATCHMAN FLX in patients on dual antiplatelet therapy at ∼3 months with data with WATCHMAN (EWOLUTION [Registry on WATCHMAN Outcomes in Real-Life Utilization]). METHODS: One hundred sixty-four consecutive patients receiving the WATCHMAN FLX device in 4 European centers were included in the retrospective ALSTER-FLX registry. As a control group for a matched-pair analysis, 1020 patients treated with the WATCHMAN device and data up to first follow-up (∼3 months) from EWOLUTION were used. RESULTS: Implantation was successful in all ALSTER-FLX patients (100%) and similar to results in EWOLUTION (99%) (P = .2). We observed no stroke or device embolization in ALSTER-FLX similar to EWOLUTION (stroke 0.5%, device embolization 0.4%) at 3 months. Numerically less ALSTER-FLX patients (2.4%) developed a device-associated thrombus as compared with 3.7% EWOLUTION patients, yet without reaching statistical significance after matching (median [95% confidence interval] device-associated thrombus pairwise event difference 2 [0-6]; P = .1). WATCHMAN FLX implantation was associated with a significant higher sealing rate compared with EWOLUTION at 3 months (ALSTER-FLX 90% vs EWOLUTION 79.4%; P = .039 after matching). Major nonprocedural bleeding events and mortality were similar after matching (median event difference for bleeding 0 [-3 to 3]; P = .6 and death 1 [-2 to 4]; P = .3). CONCLUSION: Periprocedural, early 3-month outcomes with WATCHMAN FLX demonstrate a similar safety profile and an improved sealing rate compared to the WATCHMAN device.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Accidente Cerebrovascular , Trombosis , Apéndice Atrial/cirugía , Cateterismo Cardíaco , Humanos , Análisis por Apareamiento , Sistema de Registros , Estudios Retrospectivos , Accidente Cerebrovascular/etiología , Trombosis/etiología , Resultado del Tratamiento
5.
Circ Cardiovasc Interv ; 14(5): e010195, 2021 05.
Artículo en Inglés | MEDLINE | ID: mdl-34003661

RESUMEN

BACKGROUND: Left atrial appendage closure is an established therapy in patients with atrial fibrillation. Although device-related thrombosis (DRT) is relatively rare, it is potentially linked to adverse events. As data on DRT characteristics, outcome, and treatment regimen are scarce, we aimed to assess these questions in a multicenter approach. METHODS: One hundred fifty-six patients with the diagnosis of DRT after left atrial appendage closure were included in the multinational EUROC-DRT registry. Baseline characteristics included clinical and echocardiographic data. After inclusion, all patients underwent further clinical and echocardiographic follow-up to assess DRT dynamics, treatment success, and outcome. RESULTS: DRT was detected after a median of 93 days (interquartile range, 54­161 days) with 17.9% being detected >6 months after left atrial appendage closure. Patients with DRT were at high ischemic and bleeding risk (CHA2DS2-VASc 4.5±1.7, HAS-BLED 3.3±1.2) and had nonparoxysmal atrial fibrillation (67.3%), previous stroke (53.8%), and spontaneous echo contrast (50.6%). The initial treatment regimens showed comparable resolution rates (antiplatelet monotherapy: 57.1%, dual antiplatelet therapy: 85.7%, vitamin K antagonists: 80.0%, novel oral anticoagulants: 75.0%, and heparin: 68.6%). After intensification or switch of treatment, complete DRT resolution was achieved in 79.5% of patients. Two-year follow-up revealed a high risk of mortality (20.0%) and ischemic stroke (13.8%) in patients with DRT. Patients with incomplete DRT resolution showed numerically higher stroke rates and increased mortality rates (stroke: 17.6% versus 12.3%, P=0.29; mortality: 31.3% versus 13.1%, P=0.05). CONCLUSIONS: A substantial proportion of DRT is detected >6 months after left atrial appendage closure, highlighting the need for imaging follow-up. Patients with DRT appear to be at a high risk for stroke and mortality. While DRT resolution was achieved in most patients, incomplete DRT resolution appeared to identify patients at even higher risk. Optimal DRT diagnostic criteria and treatment regimens are warranted.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Accidente Cerebrovascular , Trombosis , Apéndice Atrial/diagnóstico por imagen , Apéndice Atrial/cirugía , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/terapia , Humanos , Sistema de Registros , Accidente Cerebrovascular/diagnóstico por imagen , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/terapia , Trombosis/diagnóstico por imagen , Trombosis/etiología , Trombosis/terapia , Resultado del Tratamiento
6.
Ann Vasc Surg ; 64: 88-98, 2020 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-31634608

RESUMEN

BACKGROUND: The urgent treatment of ruptured abdominal aortic aneurysms (rAAA) remains a challenging condition with devastating morbidity and mortality. Available studies are often limited due to a significant selection bias. This study aims to illuminate real-world evidence using comprehensive data from electronic health records, registries, postmortem findings, and administrative data on all consecutively treated patients presenting with rAAA at a tertiary care center. METHODS: This is a retrospective cross-sectional cohort study covering consecutively treated patients with rAAA between 2009 and 2018. All noninvasive treatments, fatalities, and invasive repairs were included. Information on patient's characteristics, prehospital, and inpatient care was gathered. Short-term outcomes and long-term survival were analyzed for relevant subgroups. RESULTS: In total, 139 patients with rAAA (median age 75 years and 20.9% females, 79.9% infrarenal) were treated increasingly frequent by endovascular aortic repair (EVAR) when compared to open-surgical aortic repair (OSR) during the study period (16.7% in 2009 to 33.3% in 2018, P < 0.05). The rate of patients who had been turned down for rAAA repair was 10.8%, and the overall in-hospital mortality was 43.2%. Perioperative morbidity and mortality were similar for EVAR and OSR, although patients treated by OSR presented with a lower mean Glasgow Coma Scale during the prehospital (12.7 vs. 14.3) and inpatient care (12.7 vs. 14.4) (both P < 0.001), higher rates of intubation (12.8% vs. 10.9%, P < 0.001), lower systolic blood pressure (115 mm Hg vs. 127 mm Hg, P = 0.042), and more often had a cardiac arrest before the operation (14.1% vs. 2.3%, P < 0.001). Higher patient's age (Odds Ratio, OR 1.09; Hazard Ratio, HR 1.06), history of stroke or transient ischemic attack (OR 5.30; HR 2.64), higher serum creatinine (OR 1.81; HR 1.31), and occurrence of colonic ischemia (OR 11.31; HR 2.82) were significantly associated with higher odds of dying in hospital and in the longer term, respectively. CONCLUSIONS: We observed comparable outcomes following OSR and EVAR, although hemodynamically unstable patients were more likely to be treated by OSR. This study also confirmed the impact of colonic ischemia as a devastating complication following rAAA repair emphasizing the need for further reflection by the vascular community.


Asunto(s)
Aneurisma de la Aorta Abdominal/cirugía , Rotura de la Aorta/cirugía , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Hospitales de Alto Volumen , Anciano , Anciano de 80 o más Años , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/mortalidad , Aneurisma de la Aorta Abdominal/fisiopatología , Rotura de la Aorta/diagnóstico por imagen , Rotura de la Aorta/mortalidad , Rotura de la Aorta/fisiopatología , Implantación de Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/mortalidad , Toma de Decisiones Clínicas , Estudios Transversales , Procedimientos Endovasculares/efectos adversos , Procedimientos Endovasculares/mortalidad , Femenino , Hemodinámica , Mortalidad Hospitalaria , Humanos , Masculino , Selección de Paciente , Complicaciones Posoperatorias/mortalidad , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Centros de Atención Terciaria , Factores de Tiempo , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...