Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 40
Filtrar
1.
Eur Respir J ; 2024 Jul 26.
Artículo en Inglés | MEDLINE | ID: mdl-39060013

RESUMEN

OBJECTIVE: This multicenter, international, retrospective study aims to investigate whether respiratory system reactance (Xrs) assessed by respiratory oscillometry on the 7th day of life is associated with respiratory outcomes in preterm infants below 32 weeks' gestation. METHODS: Sinusoidal pressure oscillations (2-5 cmH2O peak-to-peak, 10 Hz) were superimposed on the positive end-expiratory pressure (PEEP). We assessed the association of Xrs z-score with the duration of respiratory support using linear regression and with bronchopulmonary dysplasia (BPD, according to Jensen et al. 2019) using logistic regression. We used the likelihood ratio test to evaluate whether Xrs z-score adds significantly to clinical predictors, including gestational age (GA), birth weight (BW) and the National Institute of Child Health and Human Development (NICHD) BPD prediction model. RESULTS: One hundred and thirty-seven infants (median (Q1, Q3) GA=28.43 (26.11, 30.29) weeks) were included; 44 (32%) developed BPD. Xrs z-score was significantly associated with the duration of respiratory support (R2=0.35). Xrs z-score was significantly higher in infants who developed BPD (p<0.001); the optimal cut-off value was 2.6, associated with 77% sensitivity and 80% specificity. In univariable analysis, per z-score increase in Xrs, the OR for BPD increased by 60% and the respiratory support by eight days. In multivariable analysis, Xrs z-score added significantly to the NICHD model and to GA and BW z-score to predict respiratory support duration (p=0.016 and p=0.014, respectively) and BPD development (p=0.003 and p<0.001, respectively). CONCLUSION: Xrs z-score on the 7th day after birth improves the prediction of respiratory outcome in preterm infants.

2.
Respiration ; : 1-14, 2024 Jun 07.
Artículo en Inglés | MEDLINE | ID: mdl-38843786

RESUMEN

BACKGROUND: Within-breath analysis of oscillometry parameters is a growing research area since it increases sensitivity and specificity to respiratory pathologies and conditions. However, reference equations for these parameters in White adults are lacking and devices using multiple sinusoids or pseudorandom forcing stimuli have been underrepresented in previous studies deriving reference equations. The current study aimed to establish reference ranges for oscillometry parameters, including also the within-breath ones in White adults using multi-sinusoidal oscillations. METHODS: White adults with normal spirometry, BMI ≤30 kg/m2, without a smoking history, respiratory symptoms, pulmonary or cardiac disease, neurological or neuromuscular disorders, and respiratory tract infections in the previous 4 weeks were eligible for the study. Study subjects underwent oscillometry (multifrequency waveform at 5-11-19 Hz, Resmon PRO FULL, RESTECH Srl, Italy) in 5 centers in Europe and the USA according to international standards. The within-breath and total resistance (R) and reactance (X), the resonance frequency, the area under the X curve, the frequency dependence of R (R5-19), and within-breath changes of X (ΔX) were submitted to lambda-mu-sigma models for deriving reference equations. For each output parameter, an AIC-based stepwise input variable selection procedure was applied. RESULTS: A total of 144 subjects (age 20.8-86.3 years; height 146-193 cm; BMI 17.42-29.98 kg/m2; 56% females) were included. We derived reference equations for 29 oscillatory parameters. Predicted values for inspiratory and expiratory parameters were similar, while differences were observed for their limits of normality. CONCLUSIONS: We derived reference equations with narrow confidence intervals for within-breath and whole-breath oscillatory parameters for White adults.

3.
Am J Physiol Lung Cell Mol Physiol ; 327(2): L203-L217, 2024 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-38771135

RESUMEN

This study investigated the relationship between three respiratory support approaches on lung volume recruitment during the first 2 h of postnatal life in preterm lambs. We estimated changes in lung aeration, measuring respiratory resistance and reactance by oscillometry at 5 Hz. We also measured intratracheal pressure in subsets of lambs. The first main finding is that sustained inflation (SI) applied noninvasively (Mask SI; n = 7) or invasively [endotracheal tube (ETT) SI; n = 6] led to similar rapid lung volume recruitment (∼6 min). In contrast, Mask continuous positive airway pressure (CPAP) without SI (n = 6) resuscitation took longer (∼30-45 min) to reach similar lung volume recruitment. The second main finding is that, in the first 15 min of postnatal life, the Mask CPAP without SI group closed their larynx during custom ventilator-driven expiration, leading to intratracheal positive end-expiratory pressure of ∼17 cmH2O (instead of 8 cmH2O provided by the ventilator). In contrast, the Mask SI group used the larynx to limit inspiratory pressure to ∼26 cmH2O (instead of 30 cmH2O provided by the ventilator). These different responses affected tidal volume, being larger in the Mask CPAP without SI group [8.4 mL/kg; 6.7-9.3 interquartile range (IQR)] compared to the Mask SI (5.0 mL/kg; 4.4-5.2 IQR) and ETT SI groups (3.3 mL/kg; 2.6-3.7 IQR). Distinct physiological responses suggest that spontaneous respiratory activity of the larynx of preterm lambs at birth can uncouple pressure applied by the ventilator to that applied to the lung, leading to unpredictable lung pressure and tidal volume delivery independently from the ventilator settings.NEW & NOTEWORTHY We compared invasive and noninvasive resuscitation on lambs at birth, including or not sustained inflation (SI). Lung volume recruitment was faster in those receiving SI. During noninvasive resuscitation, larynx modulation reduced tracheal pressure from that applied to the mask in lambs receiving SI, while it led to increased auto-positive end-expiratory pressure and very large tidal volumes in lambs not receiving SI. Our results highlight the need for individualizing pressures and monitoring tidal volumes during resuscitation at birth.


Asunto(s)
Animales Recién Nacidos , Pulmón , Volumen de Ventilación Pulmonar , Tráquea , Animales , Volumen de Ventilación Pulmonar/fisiología , Ovinos , Pulmón/fisiología , Tráquea/fisiología , Mecánica Respiratoria/fisiología , Presión de las Vías Aéreas Positiva Contínua/métodos , Resucitación/métodos , Intubación Intratraqueal/métodos , Presión , Respiración con Presión Positiva/métodos
4.
J Clin Med ; 13(7)2024 Mar 24.
Artículo en Inglés | MEDLINE | ID: mdl-38610633

RESUMEN

Background: Oscillometry allows for the non-invasive measurements of lung mechanics. In COVID-19 ARDS patients treated with Non-Invasive Oxygen Support (NI-OS), we aimed to (1) observe lung mechanics at the patients' admission and their subsequent changes, (2) compare lung mechanics with clinical and imaging data, and (3) evaluate whether lung mechanics helps to predict clinical outcomes. Methods: We retrospectively analyzed the data from 37 consecutive patients with moderate-severe COVID-19 ARDS. Oscillometry was performed on their 1st, 4th, and 7th day of hospitalization. Resistance (R5), reactance (X5), within-breath reactance changes (ΔX5), and the frequency dependence of the resistance (R5-R19) were considered. Twenty-seven patients underwent computed tomographic pulmonary angiography (CTPA): collapsed, poorly aerated, and normally inflated areas were quantified. Adverse outcomes were defined as intubation or death. Results: Thirty-two patients were included in this study. At the first measurement, only 44% of them had an abnormal R5 or X5. In total, 23 patients had measurements performed on their 3rd day and 7 on their 7th day of hospitalization. In general, their R5, R5-R19, and ΔX decreased with time, while their X5 increased. Collapsed areas on the CTPA correlated with the X5 z-score (ρ = -0.38; p = 0.046), while poorly aerated areas did not. Seven patients had adverse outcomes but did not present different oscillometry parameters on their 1st day of hospitalization. Conclusions: Our study confirms the feasibility of oscillometry in critically ill patients with COVID-19 pneumonia undergoing NI-OS. The X5 z-scores indicates collapsed but not poorly aerated lung areas in COVID-19 pneumonia. Our data, which show a severe impairment of gas exchange despite normal reactance in most patients with COVID-19 ARDS, support the hypothesis of a composite COVID-19 ARDS physiopathology.

5.
J Appl Physiol (1985) ; 136(6): 1499-1506, 2024 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-38634505

RESUMEN

Data on static compliance of the chest wall (Ccw) in preterm infants are scarce. We characterized the static compliance of the lung (CL) and Ccw to determine their relative contribution to static compliance of the respiratory system (Crs) in very preterm infants at 36 wk postmenstrual age (PMA). We also aimed to investigate how these compliances were influenced by the presence of bronchopulmonary dysplasia (BPD) and impacted breathing variables. Airway opening pressure, esophageal pressure, and tidal volume (VT) were measured simultaneously during a short apnea evoked by the Hering-Breuer reflex. We computed tidal breathing variables, airway resistance (R), and dynamic lung compliance (CL,dyn), inspiratory capacity (IC), and Crs, CL, and Ccw. Functional residual capacity was assessed by the multiple breath washout technique (FRCmbw). Breathing variables, compliances, and lung volumes were adjusted for body weight. Twenty-three preterm infants born at 27.2 ± 2.0 wk gestational age (GA) were studied at 36.6 ± 0.6 wk PMA. Median and interquartile range (IQR) Crs/kg is 0.69 (0.6), CL/kg 0.95 (1.0), and Ccw/kg 3.0 (2.4). Infants with BPD (n = 11) had lower Crs/kg (P = 0.013), CL/kg (P = 0.019), and Ccw/kg (P = 0.027) compared with infants without BPD. Ccw/CL ratio was equal between groups. FRCmbw/kg (P = 0.044) and IC/kg (P = 0.005) were decreased in infants with BPD. Infants with BPD have reduced static compliance of the respiratory system, the lungs, and chest wall. Decreased Crs, CL, and Ccw in infants with BPD explain the lower FRC and IC seen in these infants.NEW & NOTEWORTHY Data on chest wall compliance in very preterm infants in the postsurfactant era are scarce. To our knowledge, we are the first group to report data on static respiratory system compliance (Crs), lung compliance (CL), and chest wall compliance (Ccw) in preterm infants with and without bronchopulmonary dysplasia (BPD) in the postsurfactant era.


Asunto(s)
Displasia Broncopulmonar , Recien Nacido Prematuro , Pulmón , Mecánica Respiratoria , Pared Torácica , Humanos , Pared Torácica/fisiopatología , Pared Torácica/fisiología , Recién Nacido , Masculino , Femenino , Mecánica Respiratoria/fisiología , Displasia Broncopulmonar/fisiopatología , Rendimiento Pulmonar/fisiología , Recien Nacido Prematuro/fisiología , Pulmón/fisiopatología , Volumen de Ventilación Pulmonar/fisiología , Resistencia de las Vías Respiratorias/fisiología , Recien Nacido Extremadamente Prematuro/fisiología , Edad Gestacional , Capacidad Residual Funcional/fisiología
6.
Am J Physiol Lung Cell Mol Physiol ; 326(6): L770-L785, 2024 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-38563994

RESUMEN

Novel therapies are needed for bronchopulmonary dysplasia (BPD) because no effective treatment exists. Mesenchymal stromal cell extracellular vesicles (MSC-sEVs) have therapeutic efficacy in a mouse pup neonatal hyperoxia BPD model. We tested the hypothesis that MSC-sEVs will improve lung functional and structural development in mechanically ventilated preterm lambs. Preterm lambs (∼129 days; equivalent to human lung development at ∼28 wk gestation) were exposed to antenatal steroids, surfactant, caffeine, and supported by mechanical ventilation for 6-7 days. Lambs were randomized to blinded treatment with either MSC-sEVs (human bone marrow MSC-derived; 2 × 1011 particles iv; n = 8; 4 F/4 M) or vehicle control (saline iv; 4 F/4 M) at 6 and 78 h post delivery. Physiological targets were pulse oximetry O2 saturation 90-94% ([Formula: see text] 60-90 mmHg), [Formula: see text] 45-60 mmHg (pH 7.25-7.35), and tidal volume 5-7 mL/kg. MSC-sEVs-treated preterm lambs tolerated enteral feedings compared with vehicle control preterm lambs. Differences in weight patterns were statistically significant. Respiratory severity score, oxygenation index, A-a gradient, distal airspace wall thickness, and smooth muscle thickness around terminal bronchioles and pulmonary arterioles were significantly lower for the MSC-sEVs group. S/F ratio, radial alveolar count, secondary septal volume density, alveolar capillary surface density, and protein abundance of VEGF-R2 were significantly higher for the MSC-sEVs group. MSC-sEVs improved respiratory system physiology and alveolar formation in mechanically ventilated preterm lambs. MSC-sEVs may be an effective and safe therapy for appropriate functional and structural development of the lung in preterm infants who require mechanical ventilation and are at risk of developing BPD.NEW & NOTEWORTHY This study focused on potential treatment of preterm infants at risk of developing bronchopulmonary dysplasia (BPD), for which no effective treatment exists. We tested treatment of mechanically ventilated preterm lambs with human mesenchymal stromal cell extracellular vesicles (MSC-sEVs). The results show improved respiratory gas exchange and parenchymal growth of capillaries and epithelium that are necessary for alveolar formation. Our study provides new mechanistic insight into potential efficacy of MSC-sEVs for preterm infants at risk of developing BPD.


Asunto(s)
Animales Recién Nacidos , Displasia Broncopulmonar , Vesículas Extracelulares , Pulmón , Células Madre Mesenquimatosas , Respiración Artificial , Animales , Vesículas Extracelulares/metabolismo , Vesículas Extracelulares/trasplante , Células Madre Mesenquimatosas/metabolismo , Pulmón/metabolismo , Pulmón/patología , Respiración Artificial/efectos adversos , Respiración Artificial/métodos , Ovinos , Displasia Broncopulmonar/patología , Displasia Broncopulmonar/terapia , Displasia Broncopulmonar/metabolismo , Humanos , Femenino
8.
Respir Res ; 25(1): 4, 2024 Jan 04.
Artículo en Inglés | MEDLINE | ID: mdl-38178216

RESUMEN

RATIONALE: Lung recruitment and continuous distending pressure (CDP) titration are critical for assuring the efficacy of high-frequency ventilation (HFOV) in preterm infants. The limitation of oxygenation (peripheral oxygen saturation, SpO2) in optimizing CDP calls for evaluating other non-invasive bedside measurements. Respiratory reactance (Xrs) at 10 Hz measured by oscillometry reflects lung volume recruitment and tissue strain. In particular, lung volume recruitment and decreased tissue strain result in increased Xrs values. OBJECTIVES: In extremely preterm infants treated with HFOV as first intention, we aimed to measure the relationship between CDP and Xrs during SpO2-driven CDP optimization. METHODS: In this prospective observational study, extremely preterm infants born before 28 weeks of gestation undergoing SpO2-guided lung recruitment maneuvers were included in the study. SpO2 and Xrs were recorded at each CDP step. The optimal CDP identified by oxygenation (CDPOpt_SpO2) was compared to the CDP providing maximal Xrs on the deflation limb of the recruitment maneuver (CDPXrs). RESULTS: We studied 40 infants (gestational age at birth = 22+ 6-27+ 5 wk; postnatal age = 1-23 days). Measurements were well tolerated and provided reliable results in 96% of cases. On average, Xrs decreased during the inflation limb and increased during the deflation limb. Xrs changes were heterogeneous among the infants for the amount of decrease with increasing CDP, the decrease at the lowest CDP of the deflation limb, and the hysteresis of the Xrs vs. CDP curve. In all but five infants, the hysteresis of the Xrs vs. CDP curve suggested effective lung recruitment. CDPOpt_SpO2 and CDPXrs were highly correlated (ρ = 0.71, p < 0.001) and not statistically different (median difference [range] = -1 [-3; 9] cmH2O). However, CDPXrs were equal to CDPOpt_SpO2 in only 6 infants, greater than CDPOpt_SpO2 in 10, and lower in 24 infants. CONCLUSIONS: The Xrs changes described provide complementary information to oxygenation. Further investigation is warranted to refine recruitment maneuvers and CPD settings in preterm infants.


Asunto(s)
Ventilación de Alta Frecuencia , Recien Nacido Extremadamente Prematuro , Humanos , Recién Nacido , Oscilometría , Pulmón , Mediciones del Volumen Pulmonar/métodos , Ventilación de Alta Frecuencia/métodos
9.
Am J Respir Crit Care Med ; 209(4): 444-453, 2024 Feb 15.
Artículo en Inglés | MEDLINE | ID: mdl-37972230

RESUMEN

Rationale: Respiratory resistance (Rrs) and reactance (Xrs) as measured by oscillometry and their intrabreath changes have emerged as sensitive parameters for detecting early pathological impairments during tidal breathing. Objectives: This study evaluates the prevalence and association of abnormal oscillometry parameters with respiratory symptoms and respiratory diseases in a general adult population. Methods: A total of 7,560 subjects in the Austrian LEAD (Lung, hEart, sociAl, boDy) Study with oscillometry measurements (computed with the Resmon Pro FULL; Restech Srl) were included in this study. The presence of respiratory symptoms and doctor-diagnosed respiratory diseases was assessed using an interview-based questionnaire. Rrs and Xrs at 5 Hz, their inspiratory and expiratory components, the area above the Xrs curve, and the presence of tidal expiratory flow limitation were analyzed. Normality ranges for oscillometry parameters were defined. Measurements and Main Results: The overall prevalence of abnormal oscillometry parameters was 20%. The incidence of abnormal oscillometry increased in the presence of symptoms or diagnoses: 17% (16-18%) versus 27% (25-29%), P < 0.0001. All abnormal oscillometry parameters except Rrs at 5 Hz were significantly associated with respiratory symptoms/diseases. Significant associations were found, even in subjects with normal spirometry, with abnormal oscillometry incidence rates increasing by 6% (4-8%; P < 0.0001) in subjects with symptoms or diagnoses. Conclusions: Abnormal oscillometry parameters are present in one-fifth of this adult population and are significantly associated with respiratory symptoms and disease. Our findings underscore the potential of oscillometry as a tool for detecting and evaluating respiratory impairments, even in individuals with normal spirometry.


Asunto(s)
Pulmón , Enfermedades Respiratorias , Adulto , Humanos , Oscilometría , Respiración , Espiración , Espirometría , Volumen Espiratorio Forzado , Resistencia de las Vías Respiratorias
10.
ERJ Open Res ; 9(2)2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-37041988

RESUMEN

A patient regularly self-performing home oscillometry developed severe COVID-19 pneumonia and continued testing during and after the disease. COVID-19 suddenly worsened oscillatory reactance, which took almost 1 year to recover to pre-COVID-19 values. https://bit.ly/3WCpWC0.

11.
Neonatology ; 120(3): 404-405, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37100038
12.
Pediatr Pulmonol ; 58(5): 1454-1462, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-36748837

RESUMEN

BACKGROUND: Preterm infants have immature control of breathing and impaired pulmonary gas exchange. We hypothesized that infants with bronchopulmonary dysplasia (BPD) have a blunted ventilatory response and peripheral oxygen saturation (SpO2 ) instability during a hypoxic challenge. METHODS: We evaluated the response to hypoxia in 57 very preterm infants (38 no BPD, 10 mild BPD, 9 moderate-to-severe BPD) at 36 weeks' postmenstrual age. The fraction of inspired oxygen (FI O2 ) was reduced stepwise at 5-min intervals to achieve peripheral SpO2 between 86% and 95%. The lowest permissible FI O2 and SpO2 were 0.14% and 86%. We recorded SpO2 , FI O2 , and the respiratory signal (respiratory inductive plethysmography). We calculated respiratory rate (RR), tidal volume (VT ), minute ventilation (VE ), and respiratory drive (ratio between VT and inspiratory time, VT /TI ). SpO2 variability was expressed as the interquartile range (IQR). RESULTS: FI O2 was reduced from a median (Q1, Q3) of 0.21 (0.21, 0.21) to 0.17 (0.17, 0.18). We observed a marked individual variability in the ventilatory response to the hypoxic challenge, regardless of BPD severity. At the lowest permissible FI O2 , 37 (65%) infants reduced their VE , and 20 (35%) increased minute ventilation; 20 infants (35%) developed periodic breathing associated with increased SpO2 IQR and lower SpO2 minima, and 16 (28%) exhibited an oscillatory pattern in VE and SpO2 without end-expiratory pauses, regardless of BPD severity. CONCLUSION: In very preterm infants, a mild hypoxic challenge reduced ventilation, increased SpO2 variability and periodic breathing regardless of BPD severity.


Asunto(s)
Displasia Broncopulmonar , Enfermedades del Prematuro , Lactante , Recién Nacido , Humanos , Recien Nacido Prematuro , Saturación de Oxígeno , Pulmón , Hipoxia , Oxígeno
13.
Physiol Meas ; 44(1)2023 01 31.
Artículo en Inglés | MEDLINE | ID: mdl-36599175

RESUMEN

Objective.To examine the influence of the endotracheal tube (ETT) on respiratory reactance (Xrs) measured with the forced oscillation technique (FOT) and develop a correction method for it.Approach.In a bench study, the reactance of ETTs (Xtube) with different dimensions was measured on a breathing test lung in various respiratory settings.Main results.Xtubecan be accurately predicted by a fitted formula, with an R2of 0.97, with negligible effects due to changes in respiratory pattern and lung volume.Significance.The developed formula offers the ability to measure ETT-independent Xrsvalues of patients, improving the potential of FOT for lung function testing in mechanically ventilated newborns.


Asunto(s)
Pulmón , Respiración Artificial , Humanos , Recién Nacido , Oscilometría/métodos , Pruebas de Función Respiratoria/métodos , Intubación Intratraqueal
14.
Neonatology ; 120(3): 275-286, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36516800

RESUMEN

INTRODUCTION: We evaluate the accuracy of postnatal biochemical and lung function tests performed within 3 h from birth for predicting surfactant need in preterm infants ≤34 weeks' gestation receiving noninvasive respiratory support for respiratory distress syndrome (RDS). METHODS: We systematically searched MEDLINE, Embase, The Cochrane Library, PROSPERO, and clinicaltrials.gov databases for studies published from 2000 to November 10, 2021, cross-referencing relevant literature and contacting experts. We included diagnostic accuracy studies and systematic reviews of biochemical or lung function tests identifying the need for surfactant in preterm neonates ≤34 weeks' with RDS not intubated at birth. The authors individually assessed the risk of bias following a tailored QUADAS-2 tool. RESULTS: Eight studies, including 810 infants, met the inclusion criteria. Four tests were included: the click test, the stable microbubble test, the lamellar body count on gastric aspirates, and the forced oscillation technique. The reference standards were transparent criteria for distinguishing the infants according to oxygen requirement, which reflected the current criteria for surfactant therapy. The risk of bias was judged high because of the population selection and exclusion of participants from the analysis. There were no serious concerns regarding blinding and applicability. The individual study sensitivity and specificity range from 0.60 to 1 and from 0.51 to 0.91, respectively. It was not appropriate to combine the accuracy estimates in a meta-analysis because of the heterogeneity of the study characteristics. CONCLUSIONS: Current evidence is insufficient to recommend biochemical and lung function tests for tailoring surfactant therapy.


Asunto(s)
Surfactantes Pulmonares , Síndrome de Dificultad Respiratoria del Recién Nacido , Humanos , Recién Nacido , Recien Nacido Prematuro , Surfactantes Pulmonares/uso terapéutico , Síndrome de Dificultad Respiratoria del Recién Nacido/terapia , Síndrome de Dificultad Respiratoria del Recién Nacido/tratamiento farmacológico , Pruebas de Función Respiratoria , Tensoactivos
15.
J Vis Exp ; (202)2023 Dec 22.
Artículo en Inglés | MEDLINE | ID: mdl-38189518

RESUMEN

Normal in utero lung development and growth rely upon the expansion of airspaces and the controlled efflux of lung liquid into the amniotic space. Infants with congenital diaphragmatic hernia (CDH) also have lung hypoplasia due to occupation of the chest cavity by the stomach and bowel and, in the most severe cases, the liver. Balloon tracheal occlusion reduces the severity of lung hypoplasia in fetuses with CDH but increases the risk of premature birth. Understanding the optimal occlusion pressure and duration required to improve lung hypoplasia with tracheal occlusion is essential to improving in utero corrective treatments for CDH. The study reports a new method for continuous measurement of the intratracheal and amniotic pressures in an unoccluded and occluded fetal lamb surgical model of CDH. Time-pregnant Merino ewes underwent two recovery hysterotomies: the first at ~80 days of gestation to create the CDH, and the second at ~101 days of gestation to occlude the fetal trachea and implant an intratracheal and amniotic pressure measurement device. Lambs were delivered at ~142 days, and the pressure measurement device was removed and cleaned. The data were downloaded and filtered using a 6 h window. Transrespiratory pressure was calculated.


Asunto(s)
Hernias Diafragmáticas Congénitas , Tráquea , Animales , Femenino , Embarazo , Amnios , Feto , Hernias Diafragmáticas Congénitas/diagnóstico , Hernias Diafragmáticas Congénitas/cirugía , Ovinos , Tráquea/cirugía
16.
Front Pediatr ; 11: 1324413, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-38274467

RESUMEN

Background: Evaluating oscillometry parameters separately for the inspiratory and expiratory breath phases and their within-breath differences can help to identify exercise-induced bronchoconstriction (EIB) in pediatric outpatients disclosing exercise-induced symptoms (EIS). Aims: To assess the response in impedance parameters following an exercise challenge in patients reporting EIS. Methods: Sixty-eight patients reporting EIS (34 asthmatics and 34 suspected of asthma, age mean = 10.8 years, range = 6.0-16.0) underwent an incremental treadmill exercise test. Spirometry was performed at baseline and 1, 5-, 10-, 15-, and 20-min post exercise. Oscillometry was performed at baseline and at 3- and 18-min post exercise. Bronchodilator response to 200 µg albuterol was then assessed. EIB was defined as a forced expiratory volume in 1 s (FEV1) fall ≥10% from baseline. Expiratory and inspiratory resistance (Rrs) and reactance (Xrs), their z-score (Ducharme et al. 2022), and their mean within-breath differences (ΔRrs = Rrsexp-Rrsinsp, ΔXrs = Xrsexp-Xrsinsp) were calculated. Receiver operating characteristic (ROC) curves and their areas (AUCs) were used to evaluate impedance parameters' performances in classifying EIB. Results: Asthmatic patients developed EIB more frequently than those suspected of asthma [18/34 (52.9%) vs. 2/34 (5.9%), p < 0.001]. In the 20 subjects with EIB, Rrsinsp, Rrsexp, Xrsinsp, and Xrsexp peaked early (3'), and remained steady except for Xrsinsp, which recovered faster afterward. ΔXrs widened 18 min following the exercise and reversed sharply after bronchodilation (BD) (-1.81 ± 1.60 vs. -0.52 ± 0.80 cmH2O × s/L, p < 0.001). Cutoffs for EIB leading to the highest AUCs were a rise of 0.41 in z-score Rrsinsp (Se: 90.0%, Sp: 66.7%), and a fall of -0.64 in z-score Xrsinsp (Se: 90.0%, Sp: 75.0%). Accepting as having "positive" postexercise oscillometry changes those subjects who had both z-scores beyond respective cutoffs, sensitivity for EIB was 90.0% (18/20) and specificity, 83.3% (40/48). Conclusion: Oscillometry parameters and their within-breath differences changed markedly in pediatric patients presenting EIB and were restored after the bronchodilator. Strong agreement between z-scores of inspiratory oscillometry parameters and spirometry supports their clinical utility, though larger studies are required to validate these findings in a broader population.

17.
J Pediatr ; 251: 149-155, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-35944717

RESUMEN

OBJECTIVES: To identify short-term repeatability of forced oscillation technique (FOT) measurement of lung function, assess the lung function response to bronchodilators (BDs) by FOT, and prove the concept that only some very preterm infants manifest a change in lung mechanics in response to BD. STUDY DESIGN: We retrospectively analyzed respiratory system resistance and respiratory system reactance measured by FOT (Fabian HFOi). The measurement short-term repeatability was assessed in 43 patients on 60 occasions; BD responsiveness was assessed using a different data set, including 38 measurements in 18 infants. The coefficient of repeatability was calculated as twice the SD of differences between measurements performed 15 minutes apart. We assessed BD responsiveness by measuring respiratory system resistance and respiratory system reactance before and 15 minutes after administering 200 mcg/kg of nebulized salbutamol. A positive response was defined as an improvement in respiratory system resistance or respiratory system reactance greater than the identified coefficient of repeatability. RESULTS: The coefficient of repeatability was 7.5 cmH2O∗s/L (21%) for respiratory system resistance and 6.3 cmH2O∗s/L (21%) for respiratory system reactance. On average, respiratory system resistance did not change significantly following BD administration, though respiratory system reactance increased significantly (from -32.0 [-50.2, -24.4] to -27.9 [-38.1, -22.0] cmH2O∗s/L, P < .001). Changes in respiratory system resistance or respiratory system reactance after BD were greater than the identified coefficient of repeatability in 8 infants (44%) on 13 (34%) occasions. CONCLUSIONS: We identified a threshold to assess BD responsiveness by FOT in preterm infants. We speculate that FOT could be used to assess and personalize treatment with BD.


Asunto(s)
Resistencia de las Vías Respiratorias , Broncodilatadores , Lactante , Humanos , Recién Nacido , Broncodilatadores/uso terapéutico , Estudios Retrospectivos , Resistencia de las Vías Respiratorias/fisiología , Recien Nacido Prematuro , Pruebas de Función Respiratoria/métodos , Mecánica Respiratoria
18.
IEEE J Transl Eng Health Med ; 10: 4900708, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35415022

RESUMEN

OBJECTIVE: Monitoring infants' breathing activity is crucial in research and clinical applications but remains a challenge. This study aims to develop a contactless method to monitor breathing patterns and thoracoabdominal asynchronies in infants inside the incubator, using depth cameras. METHODS: We proposed an algorithm to extract the 3D displacements of the ribcage and abdomen from the analysis of depth images. We evaluated the accuracy of the system in-vitro vs. a reference motion capture analyzer. We also conducted a feasibility study on 12 patients receiving non-invasive respiratory support to estimate the mean and the variability of the chest wall displacements in preterm infants and evaluate the suitability of the proposed system in the clinical setting. RESULTS: In-vitro, the mean (95% CI) error in the measurement of amplitude, frequency and phase shift between compartmental displacements was -0.14 (-0.57, 0.28) mm, 0.02 (-0.99, 1.03) bpm, and -0.40 (-1.76, 0.95)°, respectively. In-vivo, the mean (95% CI) amplitude of the ribcage and abdomen displacements were 0.99 (0.34, 2.67) mm and 1.20 (0.40, 2.15) mm, respectively. CONCLUSIONS: The developed system proved accurate in-vitro and was suitable for the clinical environment. CLINICAL IMPACT: The proposed method has value for evaluating infants' breathing patterns in research applications and, after further development, may represent a simple monitoring tool for infants' respiratory activity inside the incubator.


Asunto(s)
Recien Nacido Prematuro , Pared Torácica , Estudios de Factibilidad , Humanos , Lactante , Recién Nacido , Respiración , Frecuencia Respiratoria
19.
PLoS One ; 17(3): e0265202, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35312682

RESUMEN

BACKGROUND: Non-invasive ventilation (NIV) has been increasingly used in COVID-19 patients. The limited physiological monitoring and the unavailability of respiratory mechanic measures, usually obtainable during invasive ventilation, is a limitation of NIV for ARDS and COVID-19 patients management. OBJECTIVES: This pilot study was aimed to evaluate the feasibility of non-invasively monitoring respiratory mechanics by oscillometry in COVID-19 patients with moderate-severe acute respiratory distress syndrome (ARDS) receiving NIV. METHOD: 15 COVID-19 patients affected by moderate-severe ARDS at the RICU (Respiratory Intensive Care Unit) of the University hospital of Cattinara, Trieste, Italy were recruited. Patients underwent oscillometry tests during short periods of spontaneous breathing between NIV sessions. RESULTS: Oscillometry proved to be feasible, reproducible and well-tolerated by patients. At admission, 8 of the 15 patients showed oscillometry parameters within the normal range which further slightly improved before discharge. At discharge, four patients had still abnormal respiratory mechanics, not exclusively linked to pre-existing respiratory comorbidities. Lung mechanics parameters were not correlated with oxygenation. CONCLUSIONS: Our results suggest that lung mechanics provide complementary information for improving patients phenotyping and personalisation of treatments during NIV in COVID 19 patients, especially in the presence of respiratory comorbidities where deterioration of lung mechanics may be less coupled with changes in oxygenation and more difficult to identify. Oscillometry may provide a valuable tool for monitoring lung mechanics in COVID 19 patients receiving NIV.


Asunto(s)
COVID-19/terapia , Pulmón/fisiopatología , Ventilación no Invasiva/métodos , Oscilometría/métodos , Síndrome de Dificultad Respiratoria/virología , Adulto , Anciano , COVID-19/fisiopatología , Estudios de Factibilidad , Femenino , Humanos , Italia , Masculino , Persona de Mediana Edad , Proyectos Piloto , Síndrome de Dificultad Respiratoria/fisiopatología , Síndrome de Dificultad Respiratoria/terapia , Mecánica Respiratoria , Estudios Retrospectivos
20.
Pediatr Allergy Immunol ; 33(1): e13702, 2022 01.
Artículo en Inglés | MEDLINE | ID: mdl-34797002

RESUMEN

BACKGROUND: Self-reported exercise-induced dyspnea (EID) is common among adolescents. Possible underlying pathologies are exercise-induced bronchoconstriction (EIB) and laryngeal obstruction (EILO). The forced oscillation technique (FOT) may evaluate exercise-induced changes in airway caliber. AIM: To investigate in adolescents the relationship between EID, EIB (post-exercise fall in forced expiratory volume in 1s (FEV1 )≥10%), EILO, and post-exercise challenge changes in FOT parameters. METHODS: One hundred and forty-three subjects (97 with EID) of 13-15 years old underwent a standardized exercise challenge with FOT measurement and spirometry repeatedly performed between 2 and 30 min post-exercise. EILO was studied in a subset of 123 adolescents. Subjects showing greater changes than the healthy subgroup in the modulus of the inspiratory impedance were considered FOT responders. RESULTS: EID-nonEIB subjects presented similar post-exercise changes in all FOT parameters to nonEID-nonEIB adolescents. Changes in all FOT parameters correlated with FEV1 fall. 45 of 97 EID subjects responded neither by FEV1 nor FOT to exercise. 19 and 18 subjects responded only by FEV1 (onlyFEV1 responders) or FOT (onlyFOTresponders), respectively. Only a lower baseline forced vital capacity (FVC)%predicted and a higher FEV1 /FVC distinguished the onlyFEV1 responders from onlyFOTresponders. FOT parameters did not present specific post-exercise patterns in EILO subjects. CONCLUSION: FOT can be used to identify post-exercise changes in lower airway function. However, EID has a modest relation with both FEV1 and FOT responses, highlighting the need for objective testing. More research is needed to understand whether onlyFEV1 responders and onlyFOTresponders represent different endotypes.


Asunto(s)
Disnea , Adolescente , Pruebas de Provocación Bronquial , Disnea/diagnóstico , Volumen Espiratorio Forzado , Humanos , Oscilometría , Autoinforme , Espirometría
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...