Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Nucl Med Commun ; 45(2): 108-114, 2024 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-37901928

RESUMEN

OBJECTIVES: To measure the absorbed dose to the thyroid in patients injected with 123 I-Ioflupane where the thyroid was not blocked with prophylaxis to investigate whether thyroid blocking should be limited to younger patients. This risk from the additional absorbed dose to the thyroid was then compared to the risk from iodine overdose through ingestion of the iodide prophylaxis, resulting in iodine-induced hyper/hypothyroidism (IIH). METHODS: A cohort of patients (n = 30) who did not receive thyroid prophylaxis underwent static thyroid imaging 3 h after 123 I-Ioflupane administration. The measured thyroidal uptake of free 123 I was then extrapolated to peak uptake time (24 h post-administration). This value was used to calculate cumulated activity in the thyroid and thus thyroid-thyroid absorbed dose D(rthy←rthy ) using the relevant S-value in the MIRD method. RESULTS: Mean D(rthy←rthy ) was found to be 13.6 mGy with an SD of 8.8 mGy; this would contribute an additional 0.5 mSv to the effective dose. CONCLUSION: ARSAC recommends in its Notes for Guidance prophylactic thyroid blocking if the absorbed dose to the thyroid is >50 mGy; the maximum thyroid dose in this study cohort was 36.3 mGy. With risk from IIH and its associated cardiac complications increasing with age, this study suggests that iodide prophylaxis with 123 I-Ioflupane should be reconsidered for elderly patient.


Asunto(s)
Yodo , Glándula Tiroides , Humanos , Anciano , Yoduros/farmacología , Yodo/farmacología , Dosis de Radiación
2.
Front Endocrinol (Lausanne) ; 13: 843857, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35370990

RESUMEN

Background: Subclinical thyrotoxicosis (SCT) is associated with significant morbidity and mortality, specifically increased risk of atrial fibrillation and cardiovascular death. The management is ill-defined due to the scarcity of randomised controlled studies. Some clinicians recommend radioiodine (RAI) treatment however its long-term outcome is unknown. Therefore, further data is needed to provide robust evidence-based guidelines. Methods: A prospective, single-protocol analysis of the outcome of SCT patients (Grade 1; 0.1-0.4 mIU/L and Grade 2; <0.1 mIU/L) treated with mean dose of 427 MBq of I131, followed up for up to 18 years. Thyroid function tests were measured at 4-6 weeks, 3-, 6-, and 12-months post-RAI, and annually thereafter. Cure was defined as achieving a euthyroid/hypothyroid state. Results: Seventy-eight patients with a median age of 68 years (range 36-84) and varying aetiology [55 toxic multinodular goitre (TMNG), 10 toxic nodule (TN) and 13 Graves' disease (GD)] were followed up for a median period of 7.5 years (range 1-18). The cure rate was 100%. The rates of hypothyroidism in TMNG, TN and GD were 23.6%, 30% and 38.5% respectively. The median time to hypothyroidism was 6 and 12 months in GD and TMNG/TN respectively. No differences in outcome between Grade 1 versus Grade 2 were observed. Conclusion: RAI using single mean dose of 427 MBq is effective and safe, irrespective of aetiology or grade of TSH suppression. GD patients become hypothyroid within the first year, whilst TMNG/TN for up to 9-years. Thus after 12 months of follow up, annual thyroid function monitoring is advised.


Asunto(s)
Neoplasias de la Tiroides , Tirotoxicosis , Adulto , Anciano , Anciano de 80 o más Años , Estudios de Seguimiento , Humanos , Radioisótopos de Yodo/uso terapéutico , Persona de Mediana Edad , Estudios Prospectivos , Neoplasias de la Tiroides/tratamiento farmacológico , Tirotoxicosis/inducido químicamente , Tirotoxicosis/tratamiento farmacológico , Tirotoxicosis/radioterapia
3.
Clin Endocrinol (Oxf) ; 97(1): 100-105, 2022 07.
Artículo en Inglés | MEDLINE | ID: mdl-35244288

RESUMEN

OBJECTIVE: To evaluate the prevalence and clinical significance of nonuniform technetium (99m Tc) uptake among patients with Graves' disease (GD). DESIGN, PATIENTS AND MEASUREMENTS: Patients with GD, referred between July 2005 and March 2018, had Tc99 - uptake scans and TSH-receptor antibody (TRAb) measured before antithyroid drug (ATD) therapy. Risk of relapse after ATD cessation was monitored until June 2021 and compared between GD patients based on uptake patterns. RESULTS: Of the 276 GD patients (mean age, 49.8 years; 84% female), 25 (9.0%) had nonuniform Tc99 uptake. At diagnosis, individuals with nonuniform uptake were older (mean age of 61.8 vs. 48.5 years, p < .001), had lower mean thyroid hormone levels (free thyroxine: 36.3 vs. 45.4 pmol/L, p = .04 and free triiodothyronine: 10.0 vs. 17.8 pmol/L, p < .001) and median TRAb levels (4.2 vs. 6.6 U/L, p = .04) compared with those with a uniform uptake. Older age was a significant predictor for the presence of nonuniform uptake in GD patients; odds ratio (95% confidence intervals) of 1.07 (1.03 - 1.10). The risk of relapse was similar in both groups after a median (IQR) follow-up of 41 (13-74) months after ATD cessation (56.0% vs. 46.3%, respectively); hazard ratio (95% confidence intervals) of 1.74 (0.96-3.15). CONCLUSIONS: Nonuniform radio-isotope uptake is seen in 1 in 11 patients with GD which could be misdiagnosed as toxic multinodular goitre if TRAb levels are not measured. Treatment of GD patients with nonuniform radio-isotope uptake with ATD therapy as first-line appears to be equally effective as compared with those with uniform uptake. TRAb testing should be the main diagnostic test for patients with suspected GD with radio-labelled uptake scans being reserved for those who are TRAb negative.


Asunto(s)
Autoanticuerpos , Enfermedad de Graves , Antitiroideos/uso terapéutico , Femenino , Enfermedad de Graves/diagnóstico , Humanos , Isótopos/uso terapéutico , Masculino , Persona de Mediana Edad , Prevalencia , Receptores de Tirotropina , Recurrencia
4.
Nucl Med Commun ; 39(3): 268-275, 2018 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-29346173

RESUMEN

The Alderson striatal phantom is frequently used to assess I-FP-CIT (Ioflupane) image quality and to test semi-quantification software. However, its design is associated with a number of limitations, in particular: unrealistic image appearances and inflexibility. A new physical phantom approach is proposed on the basis of subresolution phantom technology. The design incorporates thin slabs of attenuating material generated through additive manufacturing, and paper sheets with radioactive ink patterns printed on their surface, created with a conventional inkjet printer. The paper sheets and attenuating slabs are interleaved before scanning. Use of thin layers ensures that they cannot be individually resolved on reconstructed images. An investigation was carried out to demonstrate the performance of such a phantom in producing simplified I-FP-CIT uptake patterns. Single photon emission computed tomography imaging was carried out on an assembled phantom designed to mimic a healthy patient. Striatal binding ratio results and linear striatal dimensions were calculated from the reconstructed data and compared with that of 22 clinical patients without evidence of Parkinsonian syndrome, determined from clinical follow-up. Striatal binding ratio results for the fully assembled phantom were: 3.1, 3.3, 2.9 and 2.6 for the right caudate, left caudate, right putamen and right caudate, respectively. All were within two SDs of results derived from a cohort of clinical patients. Medial-lateral and anterior-posterior dimensions of the simulated striata were also within the range of values seen in clinical data. This work provides the foundation for the generation of a range of more clinically realistic, physical phantoms.


Asunto(s)
Análisis Costo-Beneficio , Fantasmas de Imagen/economía , Diagnóstico por Imagen , Impresión , Tropanos
5.
Nucl Med Commun ; 38(6): 471-479, 2017 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-28394818

RESUMEN

OBJECTIVE: The objective of this study was to quantify any improvement with the GE 'Sharp IR' point-spread function (PSF) reconstruction algorithm in addition to ordered subsets expectation maximum (OSEM) and time-of-flight (TOF) reconstruction algorithms and establish the optimum parameters to be used in clinical studies. MATERIALS AND METHODS: We conducted a range of experiments using the National Electrical Manufacturers Association image quality phantom filled with a 4 : 1 signal-to-background ratio. We scanned the phantom using the GE Discovery 690 PET/CT scanner. We varied iteration number and Gaussian filtration. Results were compared for OSEM, OSEM+TOF and OSEM+TOF+PSF reconstructions. A sample of 15 whole-body fluorine-18-fluorodeoxyglucose were reconstructed with OSEM+TOF and OSEM+TOF+PSF using a selection of optimum reconstruction parameters determined in phantom studies. Clinicians qualitatively ranked their preferred images to choose optimum parameters. RESULTS: The addition of PSF improved signal-to-noise ratios (SNRs), contrast, hot contrast recovery coefficients and noise over OSEM and OSEM+TOF reconstruction algorithms. SNRs were the highest at two iterations and with 0 or 2 mm filters with OSEM+TOF+PSF reconstruction in all phantom studies. Clinicians generally favoured OSEM+TOF+PSF reconstruction with three iterations and a 2 mm filter. CONCLUSION: PSF reconstruction significantly improved image quality for both clinical and phantom studies. We recommended the optimum reconstruction parameters using three iterations, 24 subsets and a 2 mm filter, which improved SNRs by up to 28.8% for small lesions (P<0.05).


Asunto(s)
Algoritmos , Procesamiento de Imagen Asistido por Computador/métodos , Tomografía Computarizada por Tomografía de Emisión de Positrones , Femenino , Humanos , Masculino , Persona de Mediana Edad , Fantasmas de Imagen , Control de Calidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...