Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 34
Filtrar
1.
ASAIO J ; 2024 03 06.
Artículo en Inglés | MEDLINE | ID: mdl-38446842

RESUMEN

Mechanical circulatory support (MCS) as a bridge to lung transplant is an infrequent but accepted pathway in patients who have refractory end-stage pulmonary failure. The American Association of Thoracic Surgeons Expert Consensus Guidelines, published in 2023, recommends venovenous (VV) extracorporeal membrane oxygenation (ECMO) as the initial configuration for those patients who have failed conventional medical therapy, including mechanical ventilation, while waiting for lung transplantation and needing MCS. Alternatively, venoarterial (VA) ECMO can be used in patients with acute right ventricular failure, hemodynamic instability, or refractory respiratory failure. With the advancement in percutaneous venopulmonary (VP) ECMO cannulation techniques, this option is becoming an attractive configuration as bridge to lung transplantation. This configuration enhances stability of the right ventricle, prevents recirculation with direct introduction of pulmonary artery oxygenation, and promotes hemodynamic stability during mobility, rehabilitation, and sedation-weaning trials before lung transplantation. Here, we present a case series of eight percutaneous VP ECMO as bridge to lung transplant with all patients mobilized, awake, and successfully transplanted with survival to hospital discharge.

2.
J Cardiothorac Surg ; 18(1): 134, 2023 Apr 11.
Artículo en Inglés | MEDLINE | ID: mdl-37041646

RESUMEN

COVID-19 infection can lead to severe acute respiratory distress syndrome (ARDS), right ventricular (RV) failure and pulmonary hypertension. Venovenous extracorporeal membrane oxygenation (V-V ECMO) has been used for patients with refractory hypoxemia. More recently dual-lumen right atrium to pulmonary artery oxygenated right ventricular assist devices (Oxy-RVAD) have been utilized in the severe medical refractory COVID ARDS setting. Historically, animal data has demonstrated that high continuous non-pulsatile RVAD flows, leading to unregulated and unprotected circulation through the pulmonary vessels is associated with an increased risk of pulmonary hemorrhage and increased amount of extravascular lung water. These risks are heightened in the setting of ARDS with fragile capillaries, left ventricular (LV) diastolic failure, COVID cardiomyopathy, and anticoagulation. Concurrently, due to infection, tachycardia, and refractory hypoxemia, high V-V ECMO flows to match high cardiac output are often necessary to maintain systemic oxygenation. Increase in cardiac output without a concurrent increase in VV ECMO flow will result in a higher fraction of deoxygenated blood returning to the right heart and therefore resulting in hypoxemia. Several groups have suggested using a RVAD only strategy in COVID ARDS; however, this exposes the patients to the risk of pulmonary hemorrhage. We present one of the first known cases using an RV mechanical support, partial flow pulmonary circulation, oxygenated Veno-venopulmonary (V-VP) strategy resulting in RV recovery, total renal recovery, awake rehabilitation, and recovery.


Asunto(s)
COVID-19 , Oxigenación por Membrana Extracorpórea , Insuficiencia Cardíaca , Corazón Auxiliar , Síndrome de Dificultad Respiratoria , Animales , Oxigenación por Membrana Extracorpórea/métodos , Resultado del Tratamiento , Ventrículos Cardíacos , Insuficiencia Cardíaca/etiología , Síndrome de Dificultad Respiratoria/etiología , Hipoxia/etiología
3.
ASAIO J ; 69(8): e391-e396, 2023 08 01.
Artículo en Inglés | MEDLINE | ID: mdl-36867841

RESUMEN

Extracorporeal membrane oxygenation (ECMO) is used in cases of severe respiratory failure refractory to medical management. Use of ECMO is increasing, along with new cannulation strategies including oxygenated right ventricular assist devices (oxy-RVADs). Multiple dual lumen cannulas are now available, which increase the potential for patient mobility and decrease the number of vascular access sites. However, dual lumen, single cannula flow can be limited by adequate inflow, requiring the need for an additional inflow cannula to meet patient demands. This cannula configuration may result in differential flows in the inflow and outflow limbs and altered flow dynamics, increasing the risk of intracannula thrombus. We describe a series of four patients treated with oxy-RVAD for COVID-19-associated respiratory failure complicated by dual lumen ProtekDuo intracannula thrombus.


Asunto(s)
COVID-19 , Oxigenación por Membrana Extracorpórea , Insuficiencia Respiratoria , Trombosis , Humanos , Cánula , Oxigenación por Membrana Extracorpórea/efectos adversos , COVID-19/complicaciones , Insuficiencia Respiratoria/etiología , Insuficiencia Respiratoria/terapia , Trombosis/etiología
4.
J Cardiothorac Vasc Anesth ; 34(11): 3006-3012, 2020 11.
Artículo en Inglés | MEDLINE | ID: mdl-32828653

RESUMEN

OBJECTIVE: Anticoagulation may be a challenge in coronavirus disease 2019 (COVID-19) extracorporeal membrane oxygenation due to endothelial injury and dysregulation of coagulation, which may increase the risk of thrombotic and bleeding complications. This report was created to describe the authors' single institutional experience, with emphasis on the high rate of intracranial hemorrhage for the first 10 patients with COVID-19 placed on venovenous extracorporeal membrane oxygenation (VV ECMO). DESIGN: Case series, retrospective analysis. SETTING: Single institution. PARTICIPANTS: Ten patients. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: Patient characteristics, mortality, stroke rate, and length of stay data were collected in all patients. In addition, laboratory values of D-dimer and C-reactive protein and standard measurements of prothrombin and activated partial thromboplastin time were collected on all patients. Ten patients, each confirmed with COVID-19 via reverse transcription-polymerase chain reaction, were supported on VV ECMO for acute respiratory distress syndrome (ARDS) for a mean duration of 9.4 ± 7 days. Four of 10 patients had hemorrhagic strokes, 3 of which resulted in death. At 30 days after initiation of VV ECMO, a total of 7 survivors included 6 patients discharged from the hospital and 1 patient who remained in the intensive care unit. CONCLUSIONS: In this small study of 10 patients, intracranial hemorrhage was a common complication, resulting in a high rate of death. The authors urge caution in the anticoagulation management of VV ECMO for patients with severe ARDS and COVID-19 patients. Close monitoring of all hematologic parameters is recommended during ECMO support while awaiting larger, multicenter studies to examine the best practice.


Asunto(s)
Anticoagulantes/administración & dosificación , Betacoronavirus , Infecciones por Coronavirus/terapia , Oxigenación por Membrana Extracorpórea/efectos adversos , Hemorragias Intracraneales/etiología , Neumonía Viral/terapia , Anticoagulantes/efectos adversos , COVID-19 , Infecciones por Coronavirus/epidemiología , Oxigenación por Membrana Extracorpórea/métodos , Femenino , Estudios de Seguimiento , Humanos , Hemorragias Intracraneales/diagnóstico , Masculino , Persona de Mediana Edad , Pandemias , Neumonía Viral/epidemiología , Estudios Retrospectivos , SARS-CoV-2
5.
J Cardiothorac Vasc Anesth ; 33(7): 1865-1870, 2019 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-30559066

RESUMEN

OBJECTIVES: The objectives of this study were as follows: (1) to describe a successful design for a mobile lung rescue program, focusing on challenges and resources required to support such a program, and (2) report short-term outcomes for patients placed on venovenous extracorporeal life support (VV-ECLS) by a transferring team before inter-facility transport to a specialized extracorporeal life support (ECLS) center. DESIGN: This retrospective review and analysis used patient chart review to collect outcomes data and resource demand. SETTING: A single institutional experience in an academic center in the United States. PARTICIPANTS: Patient selection targeted the 75 patients who were placed on VV-ECLS for acute respiratory failure at an outside institution by the authors' team before transport from January 1, 2015, through December 31, 2017. INTERVENTIONS: No intervention was made. MEASUREMENTS AND MAIN RESULTS: Average time for dispatch and transfer was 4 hours and 10 minutes for ground and 3 hours and 30 minutes for air transport (p = 0.029). Demand was highest in winter, with 61% (46/75) of patients presenting from November through April, and daytime, with 73% (55/75) occurring from 8 am to 8 pm. Demand increased during the study period, with 21 patients in 2015, 24 in 2016, and 30 in 2017. Mortality was low, with 72% of patients surviving to discharge. CONCLUSIONS: Herein a successful mobile lung rescue program for transfer to a regional ECLS center is described. These findings demonstrate bed availability during high census and presence of a physician for duration of transport. These challenges can be overcome and successful implementation can be made with low mortality, supporting the development of regional ECLS centers.


Asunto(s)
Oxigenación por Membrana Extracorpórea/métodos , Insuficiencia Respiratoria/terapia , Enfermedad Aguda , Adulto , Femenino , Humanos , Masculino , Persona de Mediana Edad , Transferencia de Pacientes , Estudios Retrospectivos
8.
Anesth Analg ; 124(3): 846-848, 2017 03.
Artículo en Inglés | MEDLINE | ID: mdl-27749338

RESUMEN

When clinicians consider extracorporeal life support (ECLS) for acute respiratory distress syndrome (ARDS) patients with hemodynamic instability, both veno-arterial (VA) and veno-venous (VV) ECLS are therapeutic possibilities. We analyzed 17 patients with ARDS on inotropic or vasopressor support requiring ECLS for refractory hypoxemia. After implementing VV ECLS, pressor requirements (based on norepinephrine equivalents) were significantly lower in all patients (P = .0001 for overall comparison across time points). None of the 17 patients required conversion from VV ECLS to VA ECLS (95% confidence interval 0%-20.0%). In this sample of 17 patients with substantial baseline vasopressor support and hypoxemic respiratory failure, initiation of VV ECLS was associated with reduced pressor requirements. Such a strategy may help avoid complications of VA ECLS in patients with both respiratory and hemodynamic failure.


Asunto(s)
Oxigenación por Membrana Extracorpórea/métodos , Hemodinámica/fisiología , Sistemas de Manutención de la Vida , Síndrome de Dificultad Respiratoria/fisiopatología , Síndrome de Dificultad Respiratoria/terapia , Estudios de Cohortes , Humanos , Síndrome de Dificultad Respiratoria/diagnóstico , Estudios Retrospectivos
12.
J Cardiothorac Vasc Anesth ; 29(1): 240-5, 2015 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-25620147

RESUMEN

The functional aortic annulus represents a sound clinical framework for understanding the components of the aortic root complex. Recent three-dimensional imaging analysis has demonstrated that the aortic annulus frequently is elliptical rather than circular. Comprehensive three-dimensional quantification of this aortic annular geometry by transesophageal echocardiography and/or multidetector computed tomography is essential to guide precise prosthesis sizing in transcatheter aortic valve replacement to minimize paravalvular leak for optimal clinical outcome. Furthermore, three-dimensional transesophageal echocardiography accurately can quantify additional parameters of the functional aortic annulus such as coronary height for complete sizing profiles for all valve types in transcatheter aortic valve replacement. Although it is maturing rapidly as a clinical imaging modality, its role in transcatheter aortic valve replacement is seen best as complementary to multidetector computed tomography in a multidisciplinary heart team model.


Asunto(s)
Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Ecocardiografía Tridimensional/métodos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Atención Perioperativa/métodos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Ecocardiografía Transesofágica/métodos , Humanos
16.
J Card Surg ; 29(3): 343-8, 2014 May.
Artículo en Inglés | MEDLINE | ID: mdl-24495015

RESUMEN

OBJECTIVE: To determine operative outcomes of right mini-thoracotomy mitral valve surgery utilizing port access technology in first-time and reoperative cardiac surgery patients. METHODS: From 2002 to 2011, 881 patients underwent minimally invasive mitral valve surgery. Of these, 154 patients had previous cardiac operations via sternotomy (Group 1), of which 18 (12%) had two previous operations. Seven hundred and twenty-seven patients had no previous cardiac operations (Group 2). RESULTS: Patient demographics were similar in both groups. In Group 1, 76 (49%) patients had previous coronary artery bypass grafting, 13 (8%) had previous aortic valve surgery, and 57 (37%) had previous mitral valve surgery. Preoperative echo findings for Groups 1 and 2 included severe mitral regurgitation (MR) (88%, n = 135; 94%, n = 687), mitral stenosis (MS) (4%, n = 6; 2%, n = 12), MS + MR (8%, n = 13; 4%, n = 28), and ejection fraction (48%, 56%). Operative procedures in Groups 1 and 2 were MV repair (54%, n = 84; 89%, n = 645) and MV replacement (46%, n = 70; 11%, n = 82). Circulatory management techniques for Groups 1 and 2 included endoballoon (75%, n = 116; 79%, n = 576), Chitwood clamp (8%, n = 12; 20%, n = 147), and fibrillatory arrest (17%, n = 30; 0.5%, n = 4). Perioperative outcomes were: stroke: 2.5%, 1.6%; reoperation for bleeding: 5%, 6%; valvular reoperation rate: 0.6%, 2%; aortic dissection: 2.5%, 1%; and wound infection: 0%, 0%. Transfusion requirement was 49% (n = 76) and 31% (n = 232), respectively. Median hospital stay was seven and seven days, respectively. On postoperative echocardiography, 98% (n = 151) and 99% (n = 718) of patients had zero or trace MR (1+) with 100% freedom from MR > 2+. In-hospital mortality was 3% (n = 5) and 1% (n = 8). CONCLUSIONS: Operative outcomes with minimally invasive mitral valve surgery utilizing port access technology can be performed safely. Stroke rate was higher in the reoperative cases (p = NS) although similar to reports evaluating redo sternotomy in mitral valve cases.


Asunto(s)
Cateterismo Cardíaco/métodos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Procedimientos Quirúrgicos Mínimamente Invasivos/métodos , Anuloplastia de la Válvula Mitral/métodos , Válvula Mitral/cirugía , Toracotomía/métodos , Adulto , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Reoperación , Resultado del Tratamiento
18.
J Cardiothorac Vasc Anesth ; 28(1): 1-7, 2014 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-24440007

RESUMEN

This article reviewed selected research highlights of 2013 that pertain to the specialty of cardiothoracic and vascular anesthesia. The first major theme is the commemoration of the sixtieth anniversary of the first successful cardiac surgical procedure with cardiopulmonary bypass conducted by Dr Gibbon. This major milestone revolutionized the practice of cardiovascular surgery and invigorated a paradigm of mechanical platforms for contemporary perioperative cardiovascular practice. Dr Kolff was also a leading contributor in this area because of his important contributions to the refinement of cardiopulmonary bypass and mechanical ventricular assistance. The second major theme is the diffusion of echocardiography throughout perioperative practice. There are now guidelines and training pathways to guide its generalization into everyday practice. The third major theme is the paradigm shift in perioperative fluid management. Recent large randomized trials suggest that fluids are drugs that require a precise prescription with respect to type, dose, and duration. The final theme is patient safety in the cardiac perioperative environment. A recent expert scientific statement has focused attention on this issue because most perioperative errors are preventable. It is likely that clinical research in this area will blossom because this is a major opportunity for improvement in our specialty. The patient care processes identified in these research highlights will further improve perioperative outcomes for our patients.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Puente Cardiopulmonar , Ecocardiografía , Fluidoterapia , Humanos , Seguridad del Paciente , Atención Perioperativa
20.
J Card Surg ; 28(4): 329-35, 2013 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-23879336

RESUMEN

OBJECTIVE: To evaluate the accuracy of Doppler-derived transmitral valve gradients immediately after mitral valve repair by comparing them with near simultaneously obtained direct catheter gradients. DESIGN: A prospective study. SETTING: A tertiary care medical center. PARTICIPANTS: Twenty elective adult surgical patients presenting for mitral valve repair surgery. METHODS: Mitral valve surgery proceeded in standard fashion except for the use of a smaller than usual left ventricular vent catheter (Medtronic DLP 10 French left heart vent catheter). After completion of the mitral valve repair and subsequent cardiac de-airing, the patient was weaned from cardiopulmonary bypass. Immediately after separation, the study period began. Near simultaneous transmitral Doppler gradients were obtained with directly measured catheter gradients via the vent catheter. RESULTS: While the mean peak gradient difference of 1.1 mmHg was small (p-value 0.18, 95% CI: -0.54 to 2.73 mmHg), the correlation between Doppler and catheter gradient measurements (Pearson correlation coefficient r = 0.54, p = 0.055) only approached statistical significance due to the large variance associated with the small sample size. In all patients with a peak gradient greater than 10 mmHg (4 of the 20 patients), overestimation of catheter gradients by Doppler occurred, with two showing a 62% to 73% discrepancy. In these two cases, there was also evidence for elevated left ventricular end-diastolic pressure (LVEDP) along with high transmitral blood flow velocities. CONCLUSION: Doppler-derived transmitral gradients provide a simple, safe, and reliable measure of the true physiologic transmitral valve gradient. At the same time, it is important to recognize that significant Doppler over-estimation of catheter gradients may occur in patients with elevated Doppler transmitral velocities. The causes of these overestimations are unknown. They may be related to technical recording errors. They may also be related to an inherent weakness in Doppler technology--its inability to account for any distal recovery of pressure, which in a select group of patients could be significant.


Asunto(s)
Cateterismo Cardíaco/métodos , Ecocardiografía Transesofágica/métodos , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Anciano , Anciano de 80 o más Años , Velocidad del Flujo Sanguíneo , Humanos , Persona de Mediana Edad , Válvula Mitral/patología , Válvula Mitral/fisiopatología , Insuficiencia de la Válvula Mitral/fisiopatología , Periodo Posoperatorio , Estudios Prospectivos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...