Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 24
Filtrar
1.
Adv Radiat Oncol ; 9(2): 101379, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38405312

RESUMEN

Purpose: The PERYTON trial is a multicenter randomized controlled trial that will investigate whether the treatment outcome of salvage external beam radiation therapy (sEBRT) will be improved with hypofractionated radiation therapy. A pretrial quality assurance (QA) program was undertaken to ensure protocol compliance within the PERYTON trial and to assess variation in sEBRT treatment protocols between the participating centers. Methods and Materials: Completion of the QA program was mandatory for each participating center (N = 8) to start patient inclusion. The pretrial QA program included (1) a questionnaire on the center-specific sEBRT protocol, (2) a delineation exercise of the clinical target volume (CTV) and organs at risk, and (3) a treatment planning exercise. All contours were analyzed using the pairwise dice similarity coefficient (DSC) and the 50th and 95th percentile Hausdorff distance (HD50 and HD95, respectively). The submitted treatment plans were reviewed for protocol compliance. Results: The results of the questionnaire showed that high-quality, state-of-the-art radiation therapy techniques were used in the participating centers and identified variations of the sEBRT protocols used concerning the position verification and preparation techniques. The submitted CTVs showed significant variation, with a range in volume of 29 cm3 to 167 cm3, a mean pairwise DSC of 0.52, and a mean HD50 and HD95 of 2.3 mm and 24.4 mm, respectively. Only in 1 center the treatment plan required adaptation before meeting all constraints of the PERYTON protocol. Conclusions: The pretrial QA of the PERYTON trial demonstrated that high-quality, but variable, radiation techniques were used in the 8 participating centers. The treatment planning exercise confirmed that the dose constraints of the PERYTON protocol were feasible for all participating centers. The observed variation in CTV delineation led to agreement on a new (image-based) delineation guideline to be used by all participating centers within the PERYTON trial.

2.
Int J Radiat Oncol Biol Phys ; 118(3): 688-696, 2024 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-37729971

RESUMEN

PURPOSE: Prostate-specific membrane antigen positron emission tomography/computed tomography (PSMA PET/CT) scan is the standard imaging procedure for biochemical recurrent prostate cancer postprostatectomy because of its high detection rate at low serum prostate-specific antigen levels. However, existing guidelines for clinical target volume (CTV) in prostate bed salvage external beam radiation therapy (sEBRT) are primarily based on experience-based clinical consensus and have been validated using conventional imaging modalities. Therefore, this study aimed to optimize CTV definition in sEBRT by using PSMA PET/CT-detected local recurrences (LRs). METHODS AND MATERIALS: Patients with suspected LR on PSMA PET/CT postprostatectomy were retrospectively enrolled in 9 Dutch centers. Anonymized scans were centrally reviewed by an expert nuclear medicine physician. Each boundary of the CTV guideline from the Groupe Francophone de Radiothérapie en Urologie (GFRU) was evaluated and adapted to improve the accuracy and coverage of the area at risk of LR (CTV) on PSMA PET/CT. The proposed CTV adaptation was discussed with the radiation oncologists of the participating centers, and final consensus was reached. To assess reproducibility, the participating centers were asked to delineate 3 new cases according to the new PERYTON-CTV, and the submitted contours were evaluated using the Dice similarity coefficient (DSC). RESULTS: After central review, 93 LRs were identified on 83 PSMA PET/CTs. The proposed CTV definition improved the coverage of PSMA PET/CT-detected LRs from 67% to 96% compared with the GFRU-CTV, while reducing the GFRU-CTV by 25%. The new CTV was highly reproducible, with a mean DSC of 0.82 (range, 0.81-0.83). CONCLUSIONS: This study contributes to the optimization of CTV definition in postprostatectomy sEBRT by using the pattern of LR detected on PSMA PET/CT. The PERYTON-CTV is highly reproducible across the participating centers and ensures coverage of 96% LRs while reducing the GFRU-CTV by 25%.


Asunto(s)
Tomografía Computarizada por Tomografía de Emisión de Positrones , Neoplasias de la Próstata , Masculino , Humanos , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Estudios Retrospectivos , Reproducibilidad de los Resultados , Próstata/diagnóstico por imagen , Recurrencia Local de Neoplasia/diagnóstico por imagen , Recurrencia Local de Neoplasia/radioterapia , Recurrencia Local de Neoplasia/cirugía , Neoplasias de la Próstata/diagnóstico por imagen , Neoplasias de la Próstata/radioterapia , Neoplasias de la Próstata/cirugía , Prostatectomía/métodos , Radioisótopos de Galio , Antígeno Prostático Específico
3.
Ther Adv Med Oncol ; 15: 17588359231179311, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37441326

RESUMEN

Background/objectives: Accurate and uniform interpretation and reporting of metastatic prostate cancer (PCa) lesions on prostate-specific membrane antigen (PSMA) positron emission tomography/computed tomography (PET/CT) are indispensable. 18F-PSMA-1007 is increasingly used because of its favorable imaging characteristics. However, increased non-specific skeletal uptake may be an important pitfall of this radioligand. Therefore, we aimed to assess the interobserver variation in reporting skeletal 18F-PSMA-1007 uptake on PET/CT. Design/methods: In total, 33 18F-PSMA-1007 PET/CT scans of 21 patients with primary PCa and 12 patients with biochemical recurrence were included, and a total of 85 skeletal lesions were evaluated by three independent observers. The primary endpoint was the interobserver variability of the likelihood of malignancy of the skeletal lesions on both patient and lesion level (kappa analysis). Results: Observers qualified most lesions as not malignant (81-91%) and the overall mean interobserver agreement was moderate on both patient (κ: 0.54) and lesion level (κ: 0.55). In 52 lesions without corresponding CT substrate, the rating resulted in not malignant in 95-100%. Availability of additional imaging (60% of lesions) did not improve interobserver agreement (κ: 0.39 on lesion level) and resulted in unchanged rating for all observers in 78%. Conclusion: This interobserver analysis of skeletal 18F-PSMA-1007 uptake resulted in moderate agreement, in line with rates reported in literature. Importantly, the presence of non-specific skeletal uptake without CT substrate, as a potential shortcoming of 18F-PSMA-1007, did not impair interobserver agreement.

4.
Trials ; 22(1): 768, 2021 Nov 04.
Artículo en Inglés | MEDLINE | ID: mdl-34736509

RESUMEN

BACKGROUND: The BULLSEYE trial is a multicenter, open-label, randomized controlled trial to test the hypothesis if 177Lu-PSMA is an effective treatment in oligometastatic hormone-sensitive prostate cancer (oHSPC) to prolong the progression-free survival (PFS) and postpone the need for androgen deprivation therapy (ADT). The original study protocol was published in 2020. Here, we report amendments that have been made to the study protocol since the commencement of the trial. CHANGES IN METHODS AND MATERIALS: Two important changes were made to the original protocol: (1) the study will now use 177Lu-PSMA-617 instead of 177Lu-PSMA-I&T and (2) responding patients with residual disease on 18F-PSMA PET after the first two cycles are eligible to receive additional two cycles of 7.4 GBq 177Lu-PSMA in weeks 12 and 18, summing up to a maximum of 4 cycles if indicated. Therefore, patients receiving 177Lu-PSMA-617 will also receive an interim 18F-PSMA PET scan in week 4 after cycle 2. The title of this study was modified to; "Lutetium-177-PSMA in Oligo-metastatic Hormone Sensitive Prostate Cancer" and is now partly supported by Advanced Accelerator Applications, a Novartis Company. CONCLUSIONS: We present an update of the original study protocol prior to the completion of the study. Treatment arm patients that were included and received 177Lu-PSMA-I&T under the previous protocol will be replaced. TRIAL REGISTRATION: ClinicalTrials.gov NCT04443062 . First posted: June 23, 2020.


Asunto(s)
Antagonistas de Andrógenos , Neoplasias de la Próstata Resistentes a la Castración , Hormonas , Humanos , Lutecio/efectos adversos , Masculino , Neoplasias de la Próstata Resistentes a la Castración/diagnóstico por imagen , Neoplasias de la Próstata Resistentes a la Castración/tratamiento farmacológico , Radioisótopos
5.
Clin Cancer Res ; 27(13): 3595-3601, 2021 07 01.
Artículo en Inglés | MEDLINE | ID: mdl-33883176

RESUMEN

PURPOSE: [177Lu]Lu-PSMA-617 radioligand therapy (177Lu-PSMA) is a novel treatment for metastatic castration-resistant prostate cancer (mCRPC), which could also be applied to patients with metastatic hormone-sensitive prostate cancer (mHSPC) with PSMA expression. In this prospective study (NCT03828838), we analyzed toxicity, radiation doses, and treatment effect of 177Lu-PSMA in pateints with low-volume mHSPC. PATIENTS AND METHODS: Ten progressive patients with mHSPC following local treatment, with a maximum of ten metastatic lesions on [68Ga]Ga-PSMA-11 PET/diagnostic-CT imaging (PSMA-PET) and serum PSA doubling time <6 months received two cycles of 177Lu-PSMA. Whole-body single-photon emission CT/CT (SPECT/CT) and blood dosimetry was performed to calculate doses to the tumors and organs at risk (OAR). Adverse events (AE), laboratory values (monitoring response and toxicity), and quality of life were monitored until week 24 after cycle 2, the end of study (EOS). All patients underwent PSMA-PET at screening, 8 weeks after cycle 1, 12 weeks after cycle 2, and at EOS. RESULTS: All patients received two cycles of 177Lu-PSMA without complications. No treatment-related grade III-IV adverse events were observed. According to dosimetry, none of the OAR reached threshold doses for radiation-related toxicity. Moreover, all target lesions received a higher radiation dose than the OAR. All 10 patients showed altered PSA kinetics, postponed androgen deprivation therapy, and maintained good quality of life. Half of the patients showed a PSA response of more than 50%. One patient had a complete response on PSMA-PET imaging until EOS and two others had only minimal residual disease. CONCLUSIONS: 177Lu-PSMA appeared to be a feasible and safe treatment modality in patients with low-volume mHSPC.


Asunto(s)
Antígeno Prostático Específico , Neoplasias de la Próstata Resistentes a la Castración , Antagonistas de Andrógenos/uso terapéutico , Dipéptidos/efectos adversos , Compuestos Heterocíclicos con 1 Anillo/efectos adversos , Hormonas/uso terapéutico , Humanos , Masculino , Proyectos Piloto , Estudios Prospectivos , Neoplasias de la Próstata Resistentes a la Castración/tratamiento farmacológico , Neoplasias de la Próstata Resistentes a la Castración/metabolismo , Neoplasias de la Próstata Resistentes a la Castración/radioterapia , Calidad de Vida , Radioisótopos , Radiofármacos
6.
J Nucl Med ; 62(11): 1517-1523, 2021 11.
Artículo en Inglés | MEDLINE | ID: mdl-33789933

RESUMEN

The gastrin-releasing peptide receptor (GRPr) is overexpressed in prostate cancer (PCa) cells, making it an excellent tool for targeted imaging. The 68Ga-labeled GRPr antagonist SB3 has shown excellent results in preclinical and clinical studies and was selected for further clinical investigation. The aims of this phase I study were to investigate 68Ga-SB3 PET/CT imaging of primary PCa tumors and assess safety. More aims included an investigation of biodistribution and dosimetry and a comparison with pathology and GRPr expression. Methods: Ten therapy-naïve, biopsy-confirmed PCa patients planned for prostatectomy were included. A 3-h extensive PET/CT imaging protocol was performed within 2 wk before prostatectomy. Prostate tissue was evaluated for tumor localization and Gleason score, and in vitro autoradiography was performed to determine GRPr expression. Available MRI scans performed within 3 mo before the study were matched. For dosimetry, residence times were estimated and effective dose to the body as well as absorbed doses to organs were calculated using the IDAC dose model, version 2.1. Results: Administration of 68Ga-SB3 (187.4 ± 40.0 MBq, 40 ± 5 µg) was well tolerated; no significant changes in vital signs or laboratory results were observed. 68Ga-SB3 PET/CT showed lesions in 8 of 10 patients. Pathologic analysis revealed a total of 16 tumor lesions, of which PET/CT showed 14, resulting in a sensitivity of 88%. 68Ga-SB3 PET/CT imaging showed uptake in 2 large prostatic intraepithelial neoplasia foci, considered a precursor to PCa, resulting in an 88% specificity. Autoradiography of tumor lesions revealed heterogeneous GRPr expression and was negative in 4 patients. Both PET/CT-negative patients had a GRPr-negative tumor. In autoradiography-positive tumors, the level of GRPr expression showed a significant correlation to tracer uptake on PET/CT. Dosimetry calculations estimated the effective dose to be 0.0144 mSv/MBq, similar to other 68Ga-labeled radiopeptides. The highest absorbed dose was detected in the physiologic GRPr-expressing pancreas (0.198 mGy/MBq), followed by the bladder wall and kidneys. Conclusion:68Ga-SB3 PET/CT is a safe imaging method and a promising tool for early PCa imaging.


Asunto(s)
Tomografía Computarizada por Tomografía de Emisión de Positrones , Neoplasias de la Próstata , Receptores de Bombesina , Humanos , Masculino , Persona de Mediana Edad , Distribución Tisular
7.
BMC Cancer ; 20(1): 884, 2020 Sep 14.
Artículo en Inglés | MEDLINE | ID: mdl-32928177

RESUMEN

BACKGROUND: In recent years, there is increasing evidence showing a beneficial outcome (e.g. progression free survival; PFS) after metastases-directed therapy (MDT) with external beam radiotherapy (EBRT) or targeted surgery for oligometastatic hormone sensitive prostate cancer (oHSPC). However, many patients do not qualify for these treatments due to prior interventions or tumor location. Such oligometastatic patients could benefit from radioligand therapy (RLT) with 177Lu-PSMA; a novel tumor targeting therapy for end-stage metastatic castration-resistant prostate cancer (mCRPC). Especially because RLT could be more effective in low volume disease, such as the oligometastatic status, due to high uptake of radioligands in smaller lesions. To test the hypothesis that 177Lu-PSMA is an effective treatment in oHSPC to prolong PFS and postpone the need for androgen deprivation therapy (ADT), we initiated a multicenter randomized clinical trial. This is globally, the first prospective study using 177Lu-PSMA-I&T in a randomized multicenter setting. METHODS & DESIGN: This study compares 177Lu-PSMA-I&T MDT to the current standard of care (SOC); deferred ADT. Fifty-eight patients with oHSPC (≤5 metastases on PSMA PET) and high PSMA uptake (SUVmax > 15, partial volume corrected) on 18F-PSMA PET after prior surgery and/or EBRT and a PSA doubling time of < 6 months, will be randomized in a 1:1 ratio. The patients randomized to the interventional arm will be eligible for two cycles of 7.4GBq 177Lu-PSMA-I&T at a 6-week interval. After both cycles, patients are monitored every 3 weeks (including adverse events, QoL- and xerostomia questionnaires and laboratory testing) at the outpatient clinic. Twenty-four weeks after cycle two an end of study evaluation is planned together with another 18F-PSMA PET and (whole body) MRI. Patients in the SOC arm are eligible to receive 177Lu-PSMA-I&T after meeting the primary study objective, which is the fraction of patients who show disease progression during the study follow up. A second primary objective is the time to disease progression. Disease progression is defined as a 100% increase in PSA from baseline or clinical progression. DISCUSSION: This is the first prospective randomized clinical study assessing the therapeutic efficacy and toxicity of 177Lu-PSMA-I&T for patients with oHSPC. TRIAL REGISTRATION: Clinicaltrials.gov identifier: NCT04443062 .


Asunto(s)
Lutecio/administración & dosificación , Neoplasias Hormono-Dependientes/tratamiento farmacológico , Neoplasias de la Próstata Resistentes a la Castración/tratamiento farmacológico , Neoplasias de la Próstata/tratamiento farmacológico , Radioisótopos/administración & dosificación , Antagonistas de Andrógenos/administración & dosificación , Antagonistas de Andrógenos/efectos adversos , Progresión de la Enfermedad , Hormonas/genética , Hormonas/metabolismo , Humanos , Lutecio/efectos adversos , Masculino , Persona de Mediana Edad , Metástasis de la Neoplasia , Neoplasias Hormono-Dependientes/patología , Neoplasias Hormono-Dependientes/radioterapia , Supervivencia sin Progresión , Neoplasias de la Próstata/patología , Neoplasias de la Próstata/radioterapia , Neoplasias de la Próstata Resistentes a la Castración/patología , Neoplasias de la Próstata Resistentes a la Castración/radioterapia , Calidad de Vida , Radioisótopos/efectos adversos , Radiofármacos/administración & dosificación , Resultado del Tratamiento
8.
Eur Heart J Cardiovasc Imaging ; 15(11): 1281-8, 2014 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-25073595

RESUMEN

AIMS: Hybrid single photon emission computed tomography (SPECT)/coronary computed tomography angiography (CCTA) has only been evaluated for its diagnostic accuracy as a single test in patients suspected of significant coronary artery disease (CAD). Added value of hybrid SPECT/CCTA beyond usual clinical work-up, or use of each of these tests separately, remains unclear. We evaluated the added value of hybrid myocardial perfusion SPECT (SPECT) and CCTA, beyond pre-test likelihood and exercise stress ECG (X-ECG), in the diagnosis of CAD. METHODS AND RESULTS: Two hundred and five patients with stable angina pectoris and intermediate-to-high pre-test likelihood were prospectively included. All patients underwent clinical history and examination, X-ECG, stress and rest SPECT, coronary calcium scoring (CCS) and CCTA. Fractional flow reserve measurement <0.80 or a lesion >50% on coronary angiography (CA) served as reference standard for significant CAD. Multiple imputation was used to correct for missing test results (17-20%). Added value of hybrid SPECT/CCTA to the basic model of pre-test likelihood plus X-ECG was quantified using logistic regression analysis. Model differences were then assessed using differences in C-index and in net reclassification improvement (NRI). The basic model had a C-index of 0.73 (95%CI 0.66-0.80). This significantly increased to 0.85 (95%CI 0.80-0.91) by addition of only SPECT, to 0.90 (95%CI 0.85-0.94) when adding only CCTA, and to 0.96 (95%CI 0.92-0.99) when adding hybrid SPECT/CCTA. The accompanying NRIs were 0.82 (95%CI 0.62-1.02), 0.86 (95%CI 0.66-1.06) and 1.57 (95%CI 1.11-1.59) respectively. CONCLUSION: Current analysis resembles clinical routine of layered testing and shows that hybrid SPECT/CCTA imaging has a substantially higher yield than standalone SPECT or CCTA in the diagnostic workup of patients suspected of significant CAD.


Asunto(s)
Angiografía Coronaria , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Imagen Multimodal , Tomografía Computarizada de Emisión de Fotón Único , Tomografía Computarizada por Rayos X , Estudios Transversales , Electrocardiografía , Prueba de Esfuerzo , Femenino , Reserva del Flujo Fraccional Miocárdico , Humanos , Masculino , Persona de Mediana Edad , Países Bajos , Estudios Prospectivos , Radiofármacos , Factores de Riesgo , Tecnecio Tc 99m Sestamibi
9.
Eur J Nucl Med Mol Imaging ; 41(3): 536-47, 2014 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-24030670

RESUMEN

PURPOSE: We developed and tested a single acquisition rest (99m)Tc-sestamibi/stress (201)Tl dual isotope protocol (SDI) with the intention of improving the clinical workflow and patient comfort of myocardial perfusion single photon emission computed tomography (SPECT). METHODS: The technical feasibility of SDI was evaluated by a series of anthropomorphic phantom studies on a standard SPECT camera. The attenuation map was created by a moving transmission line source. Iterative reconstruction including attenuation correction, resolution recovery and Monte Carlo simulation of scatter was used for simultaneous reconstruction of dual tracer distribution. For clinical evaluation, patient studies were compared to stress (99m)Tc and rest (99m)Tc reference images acquired in a 2-day protocol. Clinical follow-up examinations like coronary angiography (CAG) and fractional flow reserve (FFR) were included in the assessment if available. RESULTS: Phantom studies demonstrated the technical feasibility of SDI. Artificial lesions inserted in the phantom mimicking ischaemia could be clearly identified. In 51/53 patients, the image quality was adequate for clinical evaluation. For the remaining two obese patients with body mass index > 32 the injected (201)Tl dose of 74 MBq was insufficient for clinical assessment. In answer to this the (201)Tl dose was adapted for obese patients in the rest of the study. In 31 patients, SDI and (99m)Tc reference images resulted in equivalent clinical assessment. Significant differences were found in 20 patients. In 18 of these 20 patients additional examinations were available. In 15 patients the diagnosis based on the SDI images was confirmed by the results of CAG or FFR. In these patients the SDI images were more accurate than the (99m)Tc reference study. In three patients minor ischaemic lesions were detected by SDI but were not confirmed by CAG. In one of these cases this was probably caused by pronounced apical thinning. For two patients no relevant clinical follow-up information was available for evaluation. CONCLUSION: The proposed SDI protocol has the potential to improve clinical workflow and patient comfort and suggests improved accuracy as demonstrated in the clinical feasibility study.


Asunto(s)
Prueba de Esfuerzo/métodos , Imagen de Perfusión Miocárdica/métodos , Radiofármacos , Tecnecio Tc 99m Sestamibi , Talio , Tomografía Computarizada de Emisión de Fotón Único/métodos , Adulto , Anciano , Anciano de 80 o más Años , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Femenino , Humanos , Masculino , Persona de Mediana Edad , Fantasmas de Imagen , Radiofármacos/farmacocinética , Tecnecio Tc 99m Sestamibi/farmacocinética , Talio/farmacocinética
11.
Eur Heart J Cardiovasc Imaging ; 14(7): 642-9, 2013 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-23291392

RESUMEN

AIMS: Hybrid myocardial perfusion imaging with single photon emission computed tomography (SPECT) and CT coronary angiography (CCTA) has the potential to play a major role in patients with non-conclusive SPECT or CCTA results. We evaluated the performance of hybrid SPECT/CCTA vs. standalone SPECT and CCTA for the diagnosis of significant coronary artery disease (CAD) in patients with an intermediate to high pre-test likelihood of CAD. METHODS AND RESULTS: In total, 98 patients (mean age 62.5 ± 10.1 years, 68.4% male) with stable anginal complaints and a median pre-test likelihood of 87% (range 22-95%) were prospectively included in this study. Hybrid SPECT/CCTA was performed prior to conventional coronary angiography (CA) including fractional flow reserve (FFR) measurements. Hybrid analysis was performed by combined interpretation of SPECT and CCTA images. The sensitivity, specificity, positive (PPV), and negative (NPV) predictive values were calculated for standalone SPECT, CCTA, and hybrid SPECT/CCTA on per patient level, using an FFR <0.80 as a reference for significant CAD. Significant CAD was demonstrated in 56 patients (57.9%). Non-conclusive SPECT or CCTA results were found in 32 (32.7%) patients. SPECT had a sensitivity of 93%, specificity 79%, PPV 85%, and NPV 89%. CCTA had a sensitivity of 98%, specificity 62%, PPV 77%, and NPV 96%. Hybrid analysis of SPECT and CCTA improved the overall performance: sensitivity, specificity, PPV, and NPV for the presence of significant CAD to 96, 95, 96, and 95%, respectively. CONCLUSIONS: In > 40% of the patients with a high pre-test likelihood no significant CAD was demonstrated, emphasizing the value of accurate pre-treatment cardiovascular imaging. Hybrid SPECT/CCTA was able to accurately diagnose and exclude significant CAD surpassing standalone myocardial SPECT and CCTA, vs. a reference standard of FFR measurements.


Asunto(s)
Angiografía Coronaria/métodos , Enfermedad de la Arteria Coronaria/diagnóstico , Imagen Multimodal , Tomografía Computarizada de Emisión de Fotón Único/métodos , Tomografía Computarizada por Rayos X/métodos , Adulto , Anciano , Estudios de Cohortes , Intervalos de Confianza , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Estudios Transversales , Femenino , Humanos , Funciones de Verosimilitud , Masculino , Persona de Mediana Edad , Imagen de Perfusión Miocárdica/métodos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
13.
Int J Cardiovasc Imaging ; 29(3): 677-84, 2013 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-22903741

RESUMEN

Coronary calcium scoring (CCS) adds to the diagnostic performance of myocardial perfusion single-photon emission computed tomography (SPECT) to assess the presence of significant coronary artery disease (CAD). Patients with a high pre-test likelihood are expected to have a high CCS which potentially could enhance the diagnostic performance of myocardial perfusion SPECT in this specific patient group. We evaluated the added value of CCS to SPECT in the diagnosis of significant CAD in patients with an intermediate to high pre-test likelihood. In total, 129 patients (mean age 62.7 ± 9.7 years, 65 % male) with stable anginal complaints and intermediate to high pre-test likelihood of CAD (median 87 %, range 22-95) were prospectively included in this study. All patients received SPECT and CCS imaging preceding invasive coronary angiography (CA). Fractional flow reserve (FFR) measurements were acquired from patients with angiographically estimated 50-95 % obstructive CAD. For SPECT a SSS > 3 was defined significant CAD. For CCS the optimal cut-off value for significant CAD was determined by ROC curve analysis. The reference standard for significant CAD was a FFR of <0.80 acquired by CA. Significant CAD was demonstrated in 64 patients (49.6 %). Optimal CCS cut-off value for significant CAD was >182.5. ROC curve analysis for prediction of the presence of significant CAD for SPECT, CCS and the combination of CCS and SPECT resulted in an area under the curve (AUC) of 0.88 (95 % CI 81-94), 0.75 (95 % CI 66-83 %) and 0.92 (95 % CI 87-97 %) respectively. The difference of the AUC between SPECT and the combination of CCS and SPECT was 0.05 (P = 0.12). The addition of CCS did not significantly improve the diagnostic performance of SPECT in the evaluation of patients with a predominantly high pre-test likelihood of CAD.


Asunto(s)
Angiografía Coronaria/métodos , Enfermedad de la Arteria Coronaria/diagnóstico , Vasos Coronarios/diagnóstico por imagen , Tomografía Computarizada Multidetector , Imagen de Perfusión Miocárdica/métodos , Tomografía Computarizada de Emisión de Fotón Único , Calcificación Vascular/diagnóstico , Anciano , Área Bajo la Curva , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/fisiopatología , Vasos Coronarios/fisiopatología , Prueba de Esfuerzo , Femenino , Reserva del Flujo Fraccional Miocárdico , Humanos , Modelos Logísticos , Masculino , Persona de Mediana Edad , Imagen Multimodal , Tomografía de Emisión de Positrones , Valor Predictivo de las Pruebas , Pronóstico , Estudios Prospectivos , Curva ROC , Medición de Riesgo , Factores de Riesgo , Índice de Severidad de la Enfermedad , Tomografía Computarizada por Rayos X , Calcificación Vascular/diagnóstico por imagen , Calcificación Vascular/fisiopatología
14.
Heart ; 99(3): 188-94, 2013 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-23086965

RESUMEN

OBJECTIVES: To evaluate to what extent treatment decisions for patients with stable angina pectoris can be made based on hybrid myocardial perfusion single-photon emission CT (SPECT) and CT coronary angiography (CCTA). It has been shown that hybrid SPECT/CCTA has good performance in the diagnosis of significant coronary artery disease (CAD). The question remains whether these imaging results lead to similar treatment decisions as compared to standalone SPECT and invasive coronary angiography (CA). METHODS: We prospectively included 107 patients (mean age 62.8±10.0 years, 69% male) with stable anginal complaints and an intermediate to high pre-test likelihood for CAD. Hybrid SPECT/CCTA was performed prior to CA in all patients. The study outcome was the treatment decision categorised as: no revascularisation, percutaneous coronary intervention (PCI) or coronary artery bypass grafting (CABG). Treatment decisions were made by two interventional cardiologists and one cardiothoracic surgeon in two steps: first, based on the results of hybrid SPECT/CCTA; second, based on SPECT and CA. RESULTS: Revascularisation (PCI or CABG) was indicated in 54 (50%) patients based on SPECT and CA. Percentage agreement of treatment decisions in all patients based on hybrid SPECT/CCTA versus SPECT and CA on the necessity of revascularisation was 92%. Percentage agreement of treatment decisions in patients with matched, unmatched and normal hybrid SPECT/CCTA findings was 95%, 84% and 100%, respectively. CONCLUSIONS: Panel evaluation shows that patients could be accurately indicated for and deferred from revascularisation based on hybrid SPECT/CCTA.


Asunto(s)
Angina Estable/diagnóstico , Angiografía Coronaria/métodos , Toma de Decisiones , Imagen Multimodal/métodos , Imagen de Perfusión Miocárdica/métodos , Revascularización Miocárdica/métodos , Tomografía de Emisión de Positrones , Tomografía Computarizada por Rayos X , Angina Estable/cirugía , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Reproducibilidad de los Resultados , Índice de Severidad de la Enfermedad
15.
Pacing Clin Electrophysiol ; 34(5): 587-92, 2011 May.
Artículo en Inglés | MEDLINE | ID: mdl-21609339

RESUMEN

BACKGROUND: Information is scarce on the effects of right ventricular apical (RVA) pacing on regional and global myocardial blood flow (MBF). The purpose of this study was to assess the relationship between pacing rate and both regional and global MBF. METHODS: Four patients with exclusive atrial pacing and six patients with exclusive RVA pacing underwent three consecutive H(2) (15)O positron emission tomography scans at 60, 90, and 130 pulses per minute (ppm). For each pacing rate, regional and global MBF was determined. In all patients, the left ventricular (LV) function was normal. RESULTS: By varying the atrial pacing rate from 60 to 130 ppm, the mean global MBF increased from 0.94 to 1.40 mL/g/min, whereas the mean septal to lateral MBF ratio decreased from 1.09 to 0.83. In ventricular-paced patients at corresponding rates, the mean global MBF also increased from 1.07 to 1.52 mL/g/min but here the mean septal to lateral MBF ratio increased from 0.83 to 1.0. CONCLUSIONS: During both acute atrial and RVA pacing, regional and global MBF increases with higher pacing rates. However, the septal to lateral MBF ratio decreases with atrial pacing and increases with RVA pacing in patients with normal LV function. In RVA pacing, these different rate-dependent effects on regional MBF can be considered as a favorable factor that helps to understand why in some long-term paced patients, LV function is preserved.


Asunto(s)
Estimulación Cardíaca Artificial/métodos , Circulación Coronaria/fisiología , Tomografía de Emisión de Positrones , Flujo Sanguíneo Regional/fisiología , Síndrome del Seno Enfermo/diagnóstico por imagen , Síndrome del Seno Enfermo/terapia , Anciano , Análisis de Varianza , Femenino , Humanos , Masculino , Análisis de Regresión , Síndrome del Seno Enfermo/fisiopatología
16.
Nucl Med Commun ; 31(6): 539-46, 2010 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-20429095

RESUMEN

PURPOSE: Simultaneous dual isotope (SDI) acquisition of (201)Tl rest/(99m)Tc-sestamibi stress-myocardial perfusion single photon emission computed tomography is a desirable new procedure in nuclear cardiology. In this protocol (201)Tl is injected at rest but imaging is performed not earlier than after exercise. Therefore, one must be convinced that throughout exercise (201)Tl remains distributed in an identical pattern as at rest. Before SDI can be applied clinically, (201)Tl rest MPS before and after exercise test needs to be compared for equality. The aim of this study was to assess the effect of time and exercise on the clearance of preinjected (201)Tl in normal and ischemic myocardium. METHODS: In 122 patients rest (201)Tl and delayed (n =20) or poststress (n= 102) (201)Tl imaging was performed. Quantitative analysis of mean counts-per-pixel was performed for each segment in a 17-segment model. Differences between rest and delayed or poststress (201)Tl MPS were calculated. Patients with a poststress (201)Tl image were divided into normal (N= 66) and ischemic (N= 36) groups. Visual analysis was performed by two independent observers scoring the 17 segments on a scale of 0-4. RESULTS: The overall difference between rest (201)Tl and poststress (201)Tl MPS was - 15.4%. Normal and ischemic patients showed 16.2 and 14.0% (P =0.17) washout, respectively. Visual assessment by two independent observers revealed no regional differences between rest (201)Tl and delayed or poststress (201)Tl MPS. CONCLUSION: (201)Tl poststress MPS shows significant washout of thallium. This washout is not segmental, but global over the myocardium. No significant differences are found between normal and ischemic myocardium. The poststress (201)Tl MPS is a reliable reflection of rest perfusion. SDI acquisition of (201)Tl rest/(99m)Tc-sestamibi stress-MPS is clinically applicable.


Asunto(s)
Ejercicio Físico , Isquemia Miocárdica/metabolismo , Isquemia Miocárdica/fisiopatología , Talio/farmacocinética , Estudios de Casos y Controles , Femenino , Humanos , Masculino , Tasa de Depuración Metabólica , Persona de Mediana Edad , Isquemia Miocárdica/diagnóstico por imagen , Imagen de Perfusión Miocárdica , Variaciones Dependientes del Observador , Descanso , Factores de Tiempo , Tomografía Computarizada de Emisión de Fotón Único
17.
J Nucl Cardiol ; 17(2): 216-24, 2010 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-20033856

RESUMEN

BACKGROUND: The value of myocardial perfusion SPECT (MPS) for patients with left bundle branch block (LBBB) or right ventricular apical (RVA) pacing seems reduced. The prognosis of patients with only abnormal activation related perfusion defects (AARD) due to LBBB or RVA-pacing is similar to those with a normal MPS. We assessed the prognostic value of MPS in patients with LBBB or RVA pacing. METHODS: Patients with LBBB or RVA pacing referred for vasodilator stress MPS between April 2002 and January 2006 were analyzed. Group 1 are patients with normal MPS and MPS with AARD. Group 2 are patients with an MPS with a perfusion defect extending outside the AARD area. Events were cardiac death, acute myocardial infarction and coronary revascularization. RESULTS: In Group 1 (101 patients) 12 events and in Group 2 (96 patients) 45 events occurred during a mean follow-up of 2.6 +/- 1.5 years. The prognosis of Group 2 was significantly worse (49%) compared with Group 1 (91%). The annual cardiac death rate was 0.7%/year in Group 1 and 6.4%/year in Group 2 (P < .001). The prognosis of patients with LBBB was not different from those with RVA pacing. CONCLUSION: Group 2 had a significantly worse cardiac prognosis compared to Group 1. The annual cardiac death rate of <1% in Group 1 warrants a watchful waiting strategy, whereas the cardiac death rate in Group 2 warrants aggressive invasive coronary strategies.


Asunto(s)
Bloqueo de Rama/diagnóstico por imagen , Bloqueo de Rama/diagnóstico , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/diagnóstico , Tomografía Computarizada de Emisión de Fotón Único/métodos , Anciano , Femenino , Humanos , Procesamiento de Imagen Asistido por Computador , Masculino , Persona de Mediana Edad , Miocardio/patología , Perfusión , Pronóstico , Estudios Retrospectivos , Factores de Tiempo , Resultado del Tratamiento , Vasodilatadores
18.
J Nucl Cardiol ; 16(1): 97-104, 2009.
Artículo en Inglés | MEDLINE | ID: mdl-19152134

RESUMEN

BACKGROUND: To define the physical and clinical reproducibility of (201)Tl myocardial perfusion SPECT (MPS), this study assesses the variation between two repeated rest (201)Tl MPS with repositioning only, with a two-hour time interval and with phantom measurements as a reference. METHODS: Three anthropomorphic thorax phantoms were filled with (201)Tl. For each phantom five repeated (201)Tl MPS were obtained. In addition, in 20 patients repeated (201)Tl rest-MPS and in 26 patients early and delayed (201)Tl rest-MPS were performed. Quantitative analysis was done using MunichHeart. Statistical methods were used to calculate variability. Visual analysis was performed by 2 independent observers. RESULTS: The average variation between repeated phantom MPS was 0.5% (95% confidence interval (CI): -0.4% to 1.4%). For patient scans this was -5.0% (95% CI: -2.5% to -7.5%) and between early and delayed (201)Tl MPS -15.5% (95% CI: -11.7% to -19.3%). Visual assessment revealed no clinical significant differences between rest (201)Tl and repeated or delayed (201)Tl MPS. CONCLUSIONS: Repositioning in phantom (201)Tl MPS does not cause significant variation. Repeated (201)Tl MPS in patients shows 5.0% decrease of (201)Tl in 30 minutes, which increases to 15% during a two-hour time interval without quantitative or visual regional differences. This decrease indicates a time-related washout of (201)Tl, but does not change clinical diagnosis.


Asunto(s)
Ventrículos Cardíacos/diagnóstico por imagen , Interpretación de Imagen Asistida por Computador/métodos , Talio , Tomografía Computarizada de Emisión de Fotón Único/métodos , Femenino , Humanos , Aumento de la Imagen/métodos , Masculino , Persona de Mediana Edad , Fantasmas de Imagen , Radiofármacos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Tomografía Computarizada de Emisión de Fotón Único/instrumentación
19.
Eur J Echocardiogr ; 9(5): 672-7, 2008 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-18490318

RESUMEN

AIMS: A depressed left ventricular function (LVF) is sometimes observed during right ventricular apical (RVA) pacing, but any prediction of this adverse effect cannot be done. Right ventricular outflow tract (RVOT) pacing is thought to deteriorate LVF less frequently because of a more normal LV activation pattern. This study aims to assess the acute effects of RVA and RVOT pacing on LVF in order to determine the contribution of echocardiography for the selection of the optimum pacing site during pacemaker (PM) implantation. METHODS AND RESULTS: Fourteen patients with a DDD-pacemaker (7 RVA, 7 RVOT) and normal LVF without other cardiac abnormalities were studied. PM dependency, because of sick sinus syndrome with normal atrioventricular and intraventricular conduction, was absent in all, allowing acute programming changes. Wall motion score (WMS), longitudinal LV strain, and tissue Doppler imaging for electromechanical delay were assessed with echocardiography during AAI pacing constituting baseline and DDD pacing. The WMS was normal at baseline (AAI pacing) in all patients and LV dyssynchrony was absent. Acute RVA and RVOT pacing deteriorated WMS, electromechanical delay, and longitudinal LV strain, but no difference of the deterioration between both pacing sites was present and dyssynchrony did not emerge. CONCLUSION: Both acute RVA and RVOT pacing negatively affect WMS, longitudinal LV strain, and mechanical activation times, without clear differences between both pacing sites. Thus echocardiographic techniques do not facilitate the selection between RVOT and RVA pacing to exclude adverse effects on LVF during PM implantation in patients with a normal LVF.


Asunto(s)
Estimulación Cardíaca Artificial , Ventrículos Cardíacos/diagnóstico por imagen , Disfunción Ventricular Derecha/diagnóstico por imagen , Disfunción Ventricular Derecha/fisiopatología , Anciano , Femenino , Humanos , Masculino , Proyectos Piloto , Ultrasonografía , Disfunción Ventricular Derecha/terapia
20.
Clin Nucl Med ; 32(9): 683-4, 2007 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-17710018

RESUMEN

A patient with chronic myelomonocytic leukemia developed drug-induced pulmonary toxicity after using low dose oral etoposide. Because etoposide-induced pulmonary toxicity is an uncommon but serious adverse event, clinicians must be vigilant about the possibility of it, so that the optimal treatment can start as soon as possible. This report demonstrates that PET scintigraphy might be a helpful tool in the early diagnosis of drug-induced pulmonary toxicity.


Asunto(s)
Etopósido/efectos adversos , Fluorodesoxiglucosa F18 , Enfermedades Pulmonares/inducido químicamente , Enfermedades Pulmonares/diagnóstico por imagen , Tomografía de Emisión de Positrones/métodos , Administración Oral , Anciano , Antineoplásicos Fitogénicos/efectos adversos , Etopósido/administración & dosificación , Humanos , Leucemia Mielógena Crónica BCR-ABL Positiva/tratamiento farmacológico , Masculino , Radiofármacos , Enfermedades Raras/inducido químicamente , Enfermedades Raras/diagnóstico por imagen , Enfermedades Raras/prevención & control
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...