Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros













Base de datos
Intervalo de año de publicación
1.
Eur Radiol ; 2024 Jan 15.
Artículo en Inglés | MEDLINE | ID: mdl-38221584

RESUMEN

BACKGROUND: Although core needle biopsy is an important tool in minimally invasive tissue sampling and diagnostics for head and neck masses, comprehensive data about safety and outcomes is lacking. PURPOSE: To retrospectively evaluate the diagnostic performance and safety of computed tomography (CT)-guided percutaneous core needle biopsy of head and neck masses. MATERIAL AND METHODS: This retrospective single-center study included patients from 04/2007 to 12/2021, and a total of 156 core needle biopsies were evaluated. The initial histopathological results were compared with the long-term final diagnosis to evaluate the diagnostic yield of CT-guided core needle biopsies. The patients' age, sex, and history of malignancy, as well as procedural complications and radiation exposure were collected. RESULTS: A total of 156 biopsies of 150 patients (mean age 56 years ± 17; 89 men) were evaluated. 57.3% (86/150) of patients had a history of malignancy. 55.1% (86/156) of the lesions were accessed by an infrahyoid needle approach. 92.9% (145/156) of biopsies yielded conclusive results. There were no false positives and 4 false negatives, resulting in a total false negative rate of 2.7% (4/145) and a total diagnostic yield of 90.4% (141/156). There were nine puncture-related complications (9/156-5.7%). None of the complications required further reintervention. The average dose length product was 311.3 mGy × cm. CONCLUSION: CT-guided core needle biopsies of head and neck masses showed excellent results with high diagnostic yield and clinical safety. CLINICAL RELEVANCE STATEMENT: General anesthesia for open biopsy carries a higher risk for elderly patients, and fine needle aspiration has a poor reputation in terms of its diagnostic yield. This study focuses on safety and diagnostic yield of CT-guided core needle biopsies. KEY POINTS: • CT-guided core needle biopsy in head and neck tumors was a reliable and safe procedure. • The most common cause for an inconclusive biopsy result was a shortage of tissue collected during the biopsy. • During our study period of nearly 15 years, the radiation exposure of head and neck biopsies decreased.

2.
Radiol Oncol ; 57(2): 158-167, 2023 06 01.
Artículo en Inglés | MEDLINE | ID: mdl-37341197

RESUMEN

BACKGROUND: While computed tomography (CT)-guided liver biopsies are commonly performed using unenhanced images, contrast-enhanced images are beneficial for challenging puncture pathways and lesion locations. This study aimed to evaluate the accuracy of CT-guided biopsies for intrahepatic lesions using unenhanced, intravenous (IV)-enhanced, or intra-arterial Lipiodol-marked CT for lesion marking. PATIENTS AND METHODS: Six-hundred-seven patients (men: 358 [59.0%], mean age 61 years; SD ±12.04) with suspect hepatic lesions and CT-guided liver biopsies were retrospectively evaluated. Successful biopsies were histopathological findings other than typical liver tissue or non-specific findings. Data was ascertained regarding the use of contrast medium for the biopsy-planning CT, unenhanced (group 1) vs. Lipiodol (group 2) vs. IV contrast (group 3). Technical success and influencing factors were insulated. Complications were noted. The results were analyzed using the Wilcoxon-Man-Whitney t-test, Chi-square test, and Spearman-Rho. RESULTS: Overall lesion hitting rate was 73.1%, with significantly better rates using Lipiodol-marked lesions (79.3%) compared to group 1 (73.8%) and group 3 (65.2%) (p = 0.037). Smaller lesions (<20 mm diameter) benefited significantly from Lipiodol-marking with 71.2% successful biopsy rate compared to group 1 (65.5%) and group 3 (47.7%) (p = 0.021). Liver cirrhosis (p = 0.94) and entity of parenchymal lesions (p = 0.78) had no impact on the hitting rate between the groups. No major complications occurred during the interventions. CONCLUSIONS: Pre-biopsy Lipiodol marking of suspect hepatic lesions significantly increases the lesion-hitting rate and is especially beneficial for biopsy of smaller targets below 20 mm diameter. Further, Lipiodol marking is superior to IV contrast for non-visible lesions in unenhanced CT. Target lesion entity has no impact on the hitting rate.


Asunto(s)
Aceite Etiodizado , Biopsia Guiada por Imagen , Masculino , Humanos , Persona de Mediana Edad , Estudios Retrospectivos , Hígado/diagnóstico por imagen , Tomografía Computarizada por Rayos X
3.
J Craniofac Surg ; 31(5): e465-e469, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32310873

RESUMEN

BACKGROUND: Oral cancer is a common and life threatening disease that requires interdisciplinary treatment and often necessitates complex facial reconstruction. Standard care includes tumor resection, while reconstruction is routinely performed with free radial forearm flaps. As esthetic results are crucial for quality of life, flap size, flap volume, and flap composition have to be considered. To date no standardized measurement of flap volume and shrinkage has been established for routine use. The purpose of this study was therefore to evaluate the transplant volume of radial forearm flaps in craniomaxillofacial reconstruction using magnetic resonance imaging (MRI) volumetry. MATERIAL AND METHODS: Ten postoperative MR sequences of 5 patients were included. All patients had received transplantation of radial forearm flaps after tumor resection and radiation therapy. Evaluated parameters were: sex, age, type of flap, flap volume. Two different observers (1 surgeon and 1 radiologist) segmented transplant volume at three different time points in a postoperative MRI independently and in consensus, using both axial and coronal slices. A nonfat saturated T1 spin echo sequence was used. Mean transplant volume was calculated. RESULTS: A total of 90 volumetric measurements were included. Overall Tvolm was 24.83 cm from axial sections and 27.25 cm from coronal sections. Measurements for axial and coronal orientations differed significantly. Results showed excellent intra- and inter-rater correlation, coefficient for rater A and rater B were 0.91 (axial) and 0.96 (coronal). CONCLUSION: MRI volumetry is a noninvasive reproducible method to quantify volume of free radial forearm flaps in situ but should follow specific considerations for best results.


Asunto(s)
Antebrazo/diagnóstico por imagen , Neoplasias de la Boca/cirugía , Anciano , Femenino , Antebrazo/cirugía , Humanos , Imagenología Tridimensional , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Neoplasias de la Boca/diagnóstico por imagen , Calidad de Vida , Procedimientos de Cirugía Plástica , Colgajos Quirúrgicos/cirugía
4.
Eur J Radiol ; 110: 142-147, 2019 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-30599852

RESUMEN

INTRODUCTION & OBJECTIVES: Percutaneous nephrostomy [1] has emerged as a pivotal approach in the therapeutic management of the obstructed urinary tract. A consecutive incorporation of ultrasonic and radiographic guidance, the approach experienced an almost ubiquitious distribution while most centers currently applying either one or both of these tools jointly. However, success of ultrasound-guidance is limited in obese patients and non-dilated uropathy. In turn, fluoroscopy usually requires an opacification of the urinary collecting system by intravenous or antegrade contrast media injection, which might be harmful for already impaired renal function, raise intrapelvic pressure and augment the risk of sepsis and hemorrhage. CT-guided PCN aids in overcoming these limitations. In the current study, we present the experience of a tertiary referral center with this technique. MATERIALS & METHODS: Epidemiological and clinical data of all patients treated with a CT-guided PCN of native kidneys at the University Hospital Frankfurt between October 2003 and October 2013 were retrospectively collected from the patient charts. Procedural parameters including radiological aspects, technical and therapeutic success, complication and mortality rate have been analyzed statistically. RESULTS: In total, 140 PCN procedures have been performed in 77 patients with a median age of 69 (± 13). The median body mass index was 27 with 66.6% of patients being overweight or obese. Charlson comorbidity index was 7 ranging 0-16. Indications for PCNs were obstructive uropathy (62.9), urine extravasation (22.9%), urinary tract fistulas (11.4%) and technical reasons (2.8%). In 68.8% of patients, initial diagnosis was malignancy. 56.4% of kidneys were non-dilated before puncture. In 78.4% prone position, otherwise supine oblique position (17.3%) or supine position (4.3%) was used. 71.4% of PCNs were carried out solely under local anesthesia. Technical success has been achieved in 90% with a complication rate of 3.6% (all grade minor B) and was not significantly different between dilated and non-dilated kidneys. 42.9% of fistulas and 64.3% of urinary tract leakages, healed after PCN placement. 30 days mortality rate was 5.2% without being directly associated with the PCN procedure itself. CONCLUSION: CT-guided PCN is a feasible approach associated with low morbidity. It is particularly useful in complex clinical scenarios e.g. critically ill, newly operated or obese patients as well as non-dilated kidneys. Moreover, it represents a minimally-invasive option for treating leakages and fistulas of the urinary tract.


Asunto(s)
Nefrostomía Percutánea/métodos , Enfermedades Urológicas/cirugía , Anciano , Anestesia Local , Dilatación Patológica/cirugía , Estudios de Factibilidad , Femenino , Fluoroscopía/métodos , Humanos , Riñón/diagnóstico por imagen , Masculino , Obesidad/complicaciones , Sobrepeso/complicaciones , Radiografía Intervencional , Insuficiencia Renal/cirugía , Estudios Retrospectivos , Cirugía Asistida por Computador , Tomografía Computarizada por Rayos X/métodos , Ultrasonografía Intervencional , Enfermedades Uretrales/cirugía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA