1.
Herzschrittmacherther Elektrophysiol ; 26(4): 359-66, 2015 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-26315154

RESUMEN

INTRODUCTION: Unnecessary ventricular pacing is associated with increased morbidity and mortality. Over the years different algorithms have been developed to reduce right ventricular pacing. OBJECTIVES: Goal of the present study was to test the efficacy of the ventricular intrinsic preference (VIP) algorithm in patients with atrioventricular intact (AVi) and atrioventricular compromised (AVc) AV-conduction. METHODS: Evaluation of VIP feature in pacemaker patients (EVITA) was a multicenter, prospective, randomized trial (Trials.gov Identifier: NCT00366158). In total, 389 patients were randomized to AVc group: n = 140/132 VIP OFF/VIP On, AVi group: n = 54/63 VIP OFF/VIP ON). One-month post-implantation AV conduction testing (AVc: PR/AR interval > 210 ms) was performed. Follow-up visits occurred 6 and 12 months after DDD-pacemaker implantation. RESULTS: In AVi and AVc-patients initiation of the VIP feature significantly reduced incidence of ventricular pacing (AVi: 53 ± 38 vs. 9 ± 21%, p = 0.0001; AVc: 79 ± 31 vs. 28 ± 35%, p = 0.0001). DDD-pacemaker implantation per se significantly reduced incidence of AF in VIP ON (AVi 27 vs. 0%, p < 0.0001; AVc 29 vs. 3%, p < 0.0001) and VIP OFF patients (AVi 43 vs. 4%, p < 0.0001; AVc 33 vs. 3, p < 0.0001), without significant differences between VIP ON and OFF groups (p > 0.05). In the AVc group activation of VIP significantly reduced incidence of adverse events (AE). All-cause mortality was not significantly different in VIP ON (n = 5) and VIP OFF (n = 4, p > 0.05) patients. CONCLUSION: AV search hysteresis (VIP) markedly reduces ventricular pacing both in patients with normal AV conduction and in patients with prolonged PR interval or intermittent AV block.


Asunto(s)
Algoritmos , Bradicardia/mortalidad , Bradicardia/prevención & control , Estimulación Cardíaca Artificial/métodos , Estimulación Cardíaca Artificial/estadística & datos numéricos , Terapia Asistida por Computador/métodos , Adulto , Anciano , Anciano de 80 o más Años , Bloqueo Atrioventricular/diagnóstico , Bloqueo Atrioventricular/mortalidad , Bloqueo Atrioventricular/prevención & control , Bradicardia/diagnóstico , Comorbilidad , Europa (Continente)/epidemiología , Femenino , Humanos , Estudios Longitudinales , Masculino , Persona de Mediana Edad , Prevalencia , Factores de Riesgo , Método Simple Ciego , Tasa de Supervivencia , Terapia Asistida por Computador/estadística & datos numéricos , Resultado del Tratamiento , Adulto Joven
2.
Europace ; 3(4): 332-5, 2001 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-11678393

RESUMEN

The first Autocapture generation worked well with all recommended leads. The newer Autocapture generation provides a more sensitive resolution for evoked response testing and its implementation in a dual-chamber device. The purpose of the study was to evaluate the performance of the Affinity SR/DR pacemaker with the new Autocapture algorithm in combination with the small surface area pacing lead MembraneEX in 129 patients. Autocapture ventricular threshold, sensing threshold, lead impedance, evoked response (ER) and polarization signals were determined at implantation and discharge, as well as after 1 and 3 months. Autocapture recommendation rate was based on the ER sensitivity test. The median pacing threshold was 0.38, 0.50, 0.75, 0.75 V at implant, discharge, 1 and 3 months post-implant, respectively. The respective data for median lead impedance were 744, 605, 649 and 691 ohms; median sensing threshold was 12.5 mV at all visits. The median ER amplitude was 9.0, 10.1, 9.9 and 10.1 mV and the median polarization signal 0.39 mV at all visits. The frequency of recommended Autocapture activation was 98.3%, 99.2%, 98.3% and 96.2% of all patients at implant, at discharge, 1 and 3 months post-implant respectively. In conclusion, the studied pulse generator enabled, in combination with this pacing lead, in >95% of all patients activation of Autocapture.


Asunto(s)
Algoritmos , Marcapaso Artificial , Anciano , Anciano de 80 o más Años , Estimulación Cardíaca Artificial/métodos , Impedancia Eléctrica , Diseño de Equipo , Femenino , Humanos , Masculino , Persona de Mediana Edad