1.
J Med Imaging (Bellingham) ; 11(3): 037001, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38765874

RESUMEN

Purpose: To investigate the accuracy of high-framerate echo particle image velocimetry (ePIV) and computational fluid dynamics (CFD) for determining velocity vectors in femoral bifurcation models through comparison with optical particle image velocimetry (oPIV). Approach: Separate femoral bifurcation models were built for oPIV and ePIV measurements of a non-stenosed (control) and a 75%-area stenosed common femoral artery. A flow loop was used to create triphasic pulsatile flow. In-plane velocity vectors were measured with oPIV and ePIV. Flow was simulated with CFD using boundary conditions from ePIV and additional duplex-ultrasound (DUS) measurements. Mean differences and 95%-limits of agreement (1.96*SD) of the velocity magnitudes in space and time were compared, and the similarity of vector complexity (VC) and time-averaged wall shear stress (TAWSS) was assessed. Results: Similar flow features were observed between modalities with velocities up to 110 and 330 cm/s in the control and the stenosed model, respectively. Relative to oPIV, ePIV and CFD-ePIV showed negligible mean differences in velocity (<3 cm/s), with limits of agreement of ±25 cm/s (control) and ±34 cm/s (stenosed). CFD-DUS overestimated velocities with limits of agreements of 13±40 and 16.1±55 cm/s for the control and stenosed model, respectively. VC showed good agreement, whereas TAWSS showed similar trends but with higher values for ePIV, CFD-DUS, and CFD-ePIV compared to oPIV. Conclusions: EPIV and CFD-ePIV can accurately measure complex flow features in the femoral bifurcation and around a stenosis. CFD-DUS showed larger deviations in velocities making it a less robust technique for hemodynamical assessment. The applied ePIV and CFD techniques enable two- and three-dimensional assessment of local hemodynamics with high spatiotemporal resolution and thereby overcome key limitations of current clinical modalities making them an attractive and cost-effective alternative for hemodynamical assessment in clinical practice.

2.
Cardiovasc Eng Technol ; 14(6): 743-754, 2023 12.
Artículo en Inglés | MEDLINE | ID: mdl-37783950

RESUMEN

PURPOSE: Intraventricular blood flow dynamics are associated with cardiac function. Accurate, noninvasive, and easy assessments of hemodynamic quantities (such as velocity, vortex, and pressure) could be an important addition to the clinical diagnosis and treatment of heart diseases. However, the complex time-varying flow brings many challenges to the existing noninvasive image-based hemodynamic assessments. The development of reliable techniques and analysis tools is essential for the application of hemodynamic biomarkers in clinical practice. METHODS: In this study, a time-resolved particle tracking method, Shake-the-Box, was applied to reconstruct the flow in a realistic left ventricle (LV) silicone model with biological valves. Based on the obtained velocity, 4D pressure field was calculated using a Poisson equation-based pressure solver. Furthermore, flow analysis by proper orthogonal decomposition (POD) of the 4D velocity field has been performed. RESULTS: As a result of the Shake-the-Box algorithm, we have extracted: (i) particle positions, (ii) particle tracks, and finally, (iii) 4D velocity fields. From the latter, the temporal evolution of the 3D pressure field during the full cardiac cycle was obtained. The obtained maximal pressure difference extracted along the base-to-apex was about 2.7 mmHg, which is in good agreement with those reported in vivo. The POD analysis results showed a clear picture of different scale of vortices in the pulsatile LV flow, together with their time-varying information and corresponding kinetic energy content. To reconstruct 95% of the kinetic energy of the LV flow, only the first six POD modes would be required, leading to significant data reduction. CONCLUSIONS: This work demonstrated Shake-the-Box is a promising technique to accurately reconstruct the left ventricle flow field in vitro. The good spatial and temporal resolutions of the velocity measurements enabled a 4D reconstruction of the pressure field in the left ventricle. The application of POD analysis showed its potential in reducing the complexity of the high-resolution left ventricle flow measurements. For future work, image analysis, multi-modality flow assessments, and the development of new flow-derived biomarkers can benefit from fast and data-reducing POD analysis.


Asunto(s)
Ventrículos Cardíacos , Hemodinámica , Ventrículos Cardíacos/diagnóstico por imagen , Procesamiento de Imagen Asistido por Computador , Presión , Biomarcadores , Velocidad del Flujo Sanguíneo
3.
Artículo en Inglés | MEDLINE | ID: mdl-37721879

RESUMEN

Assessing the coronary circulation with contrast-enhanced echocardiography has high clinical relevance. However, it is not being routinely performed in clinical practice because the current clinical tools generally cannot provide adequate image quality. The contrast agent's visibility in the myocardium is generally poor, impaired by motion and nonlinear propagation artifacts. The established multipulse contrast schemes (MPCSs) and the more experimental singular value decomposition (SVD) filter also fall short to solve these issues. Here, we propose a scheme to process amplitude modulation/amplitude-modulated pulse inversion (AM/AMPI) echoes with higher order SVD (HOSVD) instead of conventionally summing the complementary pulses. The echoes from the complementary pulses form a separate dimension in the HOSVD algorithm. Then, removing the ranks in that dimension with dominant coherent signals coming from tissue scattering would provide the contrast detection. We performed both in vitro and in vivo experiments to assess the performance of our proposed method in comparison with the current standard methods. A flow phantom study shows that HOSVD on AM pulsing exceeds the contrast-to-background ratio (CBR) of conventional AM and an SVD filter by 10 and 14 dB, respectively. In vivo porcine heart results also demonstrate that, compared to AM, HOSVD improves CBR in open-chest acquisition (up to 19 dB) and contrast ratio (CR) in closed-chest acquisition (3 dB).


Asunto(s)
Algoritmos , Ecocardiografía , Animales , Porcinos , Corazón/diagnóstico por imagen , Tórax , Artefactos
4.
Eur Radiol Exp ; 6(1): 32, 2022 07 06.
Artículo en Inglés | MEDLINE | ID: mdl-35790584

RESUMEN

BACKGROUND: Local blood flow affects vascular disease and outcomes of endovascular treatment, but quantifying it is challenging, especially inside stents. We assessed the feasibility of blood flow quantification in native and stented femoral arteries, using high-frame-rate (HFR) contrast-enhanced ultrasound (CEUS) particle image velocimetry (PIV), also known as echoPIV. METHODS: Twenty-one patients with peripheral arterial disease, recently treated with a stent in the femoral artery, were included. HFR CEUS measurements were performed in the native femoral artery and at the inflow and outflow of the stent. Two-dimensional blood flow was quantified through PIV analysis. EchoPIV recordings were visually assessed by five observers and categorised as optimal, partial, or unfeasible. To evaluate image quality and tracking performance, contrast-to-tissue ratio (CTR) and vector correlation were calculated, respectively. RESULTS: Fifty-eight locations were measured and blood flow quantification was established in 49 of them (84%). Results were optimal for 17/58 recordings (29%) and partial for 32 recordings (55%) due to loss of correlation (5/32; 16%), short vessel segment (8/32; 25%), loss of contrast (14/32; 44%), and/or shadows (18/32; 56%). In the remaining 9/58 measurements (16%) no meaningful flow information was visualised. Overall, CTR and vector correlation were lower during diastole. CTR and vector correlation were not different between stented and native vessel segments, except for a higher native CTR at the inflow during systole (p = 0.037). CONCLUSIONS: Blood flow quantification is feasible in untreated and stented femoral arteries using echoPIV. Limitations remain, however, none of them related to the presence of the stent. TRIAL REGISTRATION: ClinicalTrials.gov, NCT04934501 (retrospectively registered).


Asunto(s)
Arteria Femoral , Stents , Estudios de Factibilidad , Arteria Femoral/diagnóstico por imagen , Humanos , Reología/métodos , Ultrasonografía/métodos
5.
J Acoust Soc Am ; 151(6): 3993, 2022 06.
Artículo en Inglés | MEDLINE | ID: mdl-35778226

RESUMEN

Ultrasound (US) contrast agents consist of microbubbles ranging from 1 to 10 µm in size. The acoustical response of individual microbubbles can be studied with high-frame-rate optics or an "acoustical camera" (AC). The AC measures the relative microbubble oscillation while the optical camera measures the absolute oscillation. In this article, the capabilities of the AC are extended to measure the absolute oscillations. In the AC setup, microbubbles are insonified with a high- (25 MHz) and low-frequency US wave (1-2.5 MHz). Other than the amplitude modulation (AM) from the relative size change of the microbubble (employed in Renaud, Bosch, van der Steen, and de Jong (2012a). "An 'acoustical camera' for in vitro characterization of contrast agent microbubble vibrations," Appl. Phys. Lett. 100(10), 101911, the high-frequency response from individual vibrating microbubbles contains a phase modulation (PM) from the microbubble wall displacement, which is the extension described here. The ratio of PM and AM is used to determine the absolute radius, R0. To test this sizing, the size distributions of two monodisperse microbubble populations ( R = 2.1 and 3.5 µm) acquired with the AC were matched to the distribution acquired with a Coulter counter. As a result of measuring the absolute size of the microbubbles, this "extended AC" can capture the full radial dynamics of single freely floating microbubbles with a throughput of hundreds of microbubbles per hour.


Asunto(s)
Microburbujas , Radio (Anatomía) , Medios de Contraste , Ultrasonografía
6.
Ultrasound Med Biol ; 48(8): 1518-1527, 2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-35577661

RESUMEN

Local flow patterns influence stent patency, while blood flow quantification in stents is challenging. The aim of this study was to investigate the feasibility of 2-D blood flow quantification using high-frame-rate, contrast-enhanced ultrasound (HFR-CEUS) and particle image velocimetry (PIV), or echoPIV, in patients with aortoiliac stents. HFR-CEUS measurements were performed at 129 locations in 62 patients. Two-dimensional blood flow velocity fields were obtained using echoPIV. Visual inspection was performed by five observers to evaluate feasibility. The contrast-to-background ratio and average vector correlation were calculated and compared between stented and native vessel segments. Flow quantification with echoPIV was feasible in 128 of 129 locations (99%), with optimal quantification in 40 of 129 locations (31%). Partial quantification was achieved in 88 of 129 locations (68%), where one or multiple limiting issues occurred (not related to the stent) including loss of correlation during systole (57/129), short vessel segments (20/129), loss of contrast during diastole (20/129) and shadow regions (20/129). The contrast-to-background ratio and vector correlation were lower downstream in the imaged blood vessel, independent of the location of the stent. In conclusion, echoPIV was feasible in stents placed in the aortoiliac region, and the stents did not adversely affect flow tracking.


Asunto(s)
Hemodinámica , Stents , Aorta , Velocidad del Flujo Sanguíneo/fisiología , Estudios de Factibilidad , Humanos , Reología
7.
Artículo en Inglés | MEDLINE | ID: mdl-35594222

RESUMEN

Suppressing tissue clutter is an essential step in blood flow estimation and visualization, even when using ultrasound contrast agents. Blind source separation (BSS)-based clutter filter for high-framerate ultrasound imaging has been reported to perform better in tissue clutter suppression than the conventional frequency-based wall filter and nonlinear contrast pulsing schemes. The most notable BSS technique, singular value decomposition (SVD) has shown compelling results in cases of slow tissue motion. However, its performance degrades when the tissue motion is faster than the blood flow speed, conditions that are likely to occur when imaging the small vessels, such as in the myocardium. Independent component analysis (ICA) is another BSS technique that has been implemented as a clutter filter in the spatiotemporal domain. Instead, we propose to implement ICA in the spatial domain where motion should have less impact. In this work, we propose a clutter filter with the combination of SVD and ICA to improve the contrast-to-background ratio (CBR) in cases where tissue velocity is significantly faster than the flow speed. In an in vitro study, the range of fast tissue motion velocity was 5-25 mm/s and the range of flow speed was 1-12 mm/s. Our results show that the combination of ICA and SVD yields 7-10 dB higher CBR than SVD alone, especially in the tissue high-velocity range. The improvement is crucial for cardiac imaging where relatively fast myocardial motions are expected.


Asunto(s)
Medios de Contraste , Procesamiento de Señales Asistido por Computador , Velocidad del Flujo Sanguíneo/fisiología , Movimiento (Física) , Fantasmas de Imagen , Ultrasonografía/métodos
8.
Cardiovasc Ultrasound ; 20(1): 11, 2022 Apr 26.
Artículo en Inglés | MEDLINE | ID: mdl-35473581

RESUMEN

BACKGROUND: Echo-Particle Image Velocimetry (echoPIV) tracks speckle patterns from ultrasound contrast agent(UCA), being less angle-sensitive than colour Doppler. High frame rate (HFR) echoPIV enables tracking of high velocity flow in the left ventricle (LV). We aimed to demonstrate the potential clinical use of HFR echoPIV and investigate the feasibility and accuracy in patients. METHODS: Nineteen patients admitted for heart failure were included. HFR contrast images were acquired from an apical long axis view (ALAX), using a fully-programmable ultrasound system. A clinical UCA was continuously infused with a dedicated pump. Additionally, echocardiographic images were obtained using a clinical system, including LV contrast-enhanced images and pulsed-wave (PW) Doppler of the LV inflow and outflow in ALAX. 11 patients underwent CMR and 4 cardiac CT as clinically indicated. These CMR and CT images were used as reference. In 10 patients with good echoPIV tracking and reference imaging, the intracavitary flow was compared between echoPIV, conventional and UCA echocardiography. RESULTS: EchoPIV tracking quality was good in 12/19 (63%), moderate in 2/19 (10%) and poor in 5/19 (26%) subjects. EchoPIV could determine inflow velocity in 17/19 (89%), and outflow in 14/19 (74%) patients. The correlation of echoPIV and PW Doppler was good for the inflow (R2 = 0.77 to PW peak; R2 = 0.80 PW mean velocity) and moderate for the outflow (R2 = 0.54 to PW peak; R2 = 0.44 to PW mean velocity), with a tendency for echoPIV to underestimate PW velocities. In selected patients, echoPIV was able in a single acquisition to demonstrate flow patterns which required multiple interrogations with classical echocardiography. Those flow patterns could also be linked to anatomical abnormalities as seen in CMR or CT. CONCLUSION: HFR echoPIV tracks multidirectional and complex flow patterns which are unapparent with conventional echocardiography, while having comparable feasibility. EchoPIV tends to underestimate flow velocities as compared to PW Doppler. It has the potential to provide in one acquisition all the functional information obtained by conventional imaging, overcoming the angle dependency of Doppler and low frame rate of classical contrast imaging.


Asunto(s)
Ecocardiografía , Ventrículos Cardíacos , Velocidad del Flujo Sanguíneo , Ecocardiografía/métodos , Ventrículos Cardíacos/diagnóstico por imagen , Humanos , Fantasmas de Imagen , Reología/métodos
9.
Magn Reson Med ; 87(5): 2398-2411, 2022 05.
Artículo en Inglés | MEDLINE | ID: mdl-34866236

RESUMEN

PURPOSE: To assess errors associated with EPI-accelerated intracardiac 4D flow MRI (4DEPI) with EPI factor 5, compared with non-EPI gradient echo (4DGRE). METHODS: Three 3T MRI experiments were performed comparing 4DEPI to 4DGRE: steady flow through straight tubes, pulsatile flow in a left-ventricle phantom, and intracardiac flow in 10 healthy volunteers. For each experiment, 4DEPI was repeated with readout and blip phase-encoding gradient in different orientations, parallel or perpendicular to the flow direction. In vitro flow rates were compared with timed volumetric collection. In the left-ventricle phantom and in vivo, voxel-based speed and spatio-temporal median speed were compared between sequences, as well as mitral and aortic transvalvular net forward volume. RESULTS: In steady-flow phantoms, the flow rate error was largest (12%) for high velocity (>2 m/s) with 4DEPI readout gradient parallel to the flow. Voxel-based speed and median speed in the left-ventricle phantom were ≤5.5% different between sequences. In vivo, mean net forward volume inconsistency was largest (6.4 ± 8.5%) for 4DEPI with nonblip phase-encoding gradient parallel to the main flow. The difference in median speed for 4DEPI versus 4DGRE was largest (9%) when the 4DEPI readout gradient was parallel to the flow. CONCLUSIONS: Velocity and flow rate are inaccurate for 4DEPI with EPI factor 5 when flow is parallel to the readout or blip phase-encoding gradient. However, mean differences in flow rate, voxel-based speed, and spatio-temporal median speed were acceptable (≤10%) when comparing 4DEPI to 4DGRE for intracardiac flow in healthy volunteers.


Asunto(s)
Imagen Eco-Planar , Imagenología Tridimensional , Velocidad del Flujo Sanguíneo , Corazón/diagnóstico por imagen , Humanos , Imagen por Resonancia Magnética , Fantasmas de Imagen
10.
Cardiovasc Ultrasound ; 19(1): 38, 2021 Dec 08.
Artículo en Inglés | MEDLINE | ID: mdl-34876127

RESUMEN

BACKGROUND: The aim of this systematic review was to evaluate current inter-modality agreement of noninvasive clinical intraventricular flow (IVF) assessment with 3 emerging imaging modalities: echocardiographic particle image velocimetry (EPIV), vector flow mapping (VFM), and 4-dimensional flow cardiovascular magnetic resonance imaging (4D flow CMR). METHODS: We performed a systematic literature review in the databases EMBASE, Medline OVID and Cochrane Central for identification of studies evaluating left ventricular (LV) flow patterns using one of these flow visualization modalities. Of the 2224 initially retrieved records, 10 EPIV, 23 VFM, and 25 4D flow CMR studies were included in the final analysis. RESULTS: Vortex parameters were more extensively studied with EPIV, while LV energetics and LV transport mechanics were mainly studied with 4D flow CMR, and LV energy loss and vortex circulation were implemented by VFM studies. Pooled normative values are provided for these parameters. The meta- analysis for the values of two vortex morphology parameters, vortex length and vortex depth, failed to reveal a significant change between heart failure patients and healthy controls. CONCLUSION: Agreement between the different modalities studying intraventricular flow is low and different methods of measurement and reporting were used among studies. A multimodality framework with a standardized set of flow parameters is necessary for implementation of noninvasive flow visualization in daily clinical practice. The full potential of noninvasive flow visualization in addition to diagnostics could also include guiding medical or interventional treatment.


Asunto(s)
Insuficiencia Cardíaca , Función Ventricular Izquierda , Velocidad del Flujo Sanguíneo , Ecocardiografía , Ventrículos Cardíacos/diagnóstico por imagen , Humanos , Imagen por Resonancia Magnética
11.
Radiology ; 301(2): 332-338, 2021 11.
Artículo en Inglés | MEDLINE | ID: mdl-34427462

RESUMEN

Background The accurate quantification of blood flow in aortoiliac arteries is challenging but clinically relevant because local flow patterns can influence atherosclerotic disease. Purpose To investigate the feasibility and clinical application of two-dimensional blood flow quantification using high-frame-rate contrast-enhanced US (HFR-CEUS) and particle image velocimetry (PIV), or US velocimetry, in participants with aortoiliac stenosis. Materials and Methods In this prospective study, participants with a recently diagnosed aortoiliac stenosis underwent HFR-CEUS measurements of the pre- and poststenotic vessel segments (August 2018 to July 2019). Two-dimensional quantification of blood flow was achieved by performing PIV analysis, which was based on pairwise cross-correlation of the HFR-CEUS images. Visual inspection of the entire data set was performed by five observers to evaluate the ability of the technique to enable adequate visualization of blood flow. The contrast-to-background ratio and average vector correlation were calculated. In two participants who showed flow disturbances, the flow complexity and vorticity were calculated. Results Thirty-five participants (median age, 67 years; age range, 56-84 years; 22 men) were included. Visual scoring showed that flow quantification was achieved in 41 of 42 locations. In 25 locations, one or multiple issues occurred that limited optimal flow quantification, including loss of correlation during systole (n = 12), shadow regions (n = 8), a short vessel segment in the image plane (n = 7), and loss of contrast during diastole (n = 5). In the remaining 16 locations, optimal quantification was achieved. The contrast-to-background ratio was higher during systole than during diastole (11.0 ± 2.9 vs 6.9 ± 3.4, respectively; P < .001), whereas the vector correlation was lower (0.58 ± 0.21 vs 0.47 ± 0.13; P < .001). The flow complexity and vorticity were high in regions with disturbed flow. Conclusion Blood flow quantification with US velocimetry is feasible in patients with an aortoiliac stenosis, but several challenges must be overcome before implementation into clinical practice. Clinical trial registration no. NTR6980 © RSNA, 2021 Online supplemental material is available for this article.


Asunto(s)
Enfermedades de la Aorta/diagnóstico por imagen , Enfermedades de la Aorta/fisiopatología , Arteriopatías Oclusivas/diagnóstico por imagen , Arteriopatías Oclusivas/fisiopatología , Reología/métodos , Ultrasonografía/métodos , Anciano , Anciano de 80 o más Años , Aorta/diagnóstico por imagen , Aorta/fisiopatología , Medios de Contraste , Estudios de Factibilidad , Femenino , Humanos , Arteria Ilíaca/diagnóstico por imagen , Arteria Ilíaca/fisiopatología , Aumento de la Imagen/métodos , Masculino , Persona de Mediana Edad , Estudios Prospectivos
13.
Artículo en Inglés | MEDLINE | ID: mdl-33720832

RESUMEN

High-frame-rate (HFR) echo-particle image velocimetry (echoPIV) is a promising tool for measuring intracardiac blood flow dynamics. In this study, we investigate the optimal ultrasound contrast agent (UCA: SonoVue) infusion rate and acoustic output to use for HFR echoPIV (PRF = 4900 Hz) in the left ventricle (LV) of patients. Three infusion rates (0.3, 0.6, and 1.2 ml/min) and five acoustic output amplitudes (by varying transmit voltage: 5, 10, 15, 20, and 30 V-corresponding to mechanical indices of 0.01, 0.02, 0.03, 0.04, and 0.06 at 60-mm depth) were tested in 20 patients admitted for symptoms of heart failure. We assess the accuracy of HFR echoPIV against pulsed-wave Doppler acquisitions obtained for mitral inflow and aortic outflow. In terms of image quality, the 1.2-ml/min infusion rate provided the highest contrast-to-background ratio (CBR) (3-dB improvement over 0.3 ml/min). The highest acoustic output tested resulted in the lowest CBR. Increased acoustic output also resulted in increased microbubble disruption. For the echoPIV results, the 1.2-ml/min infusion rate provided the best vector quality and accuracy; mid-range acoustic outputs (corresponding to 15-20-V transmit voltages) provided the best agreement with the pulsed-wave Doppler. Overall, the highest infusion rate (1.2 ml/min) and mid-range acoustic output amplitudes provided the best image quality and echoPIV results.


Asunto(s)
Ventrículos Cardíacos , Microburbujas , Acústica , Medios de Contraste , Ventrículos Cardíacos/diagnóstico por imagen , Humanos , Ultrasonografía
14.
J Med Imaging (Bellingham) ; 8(1): 017001, 2021 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-33457445

RESUMEN

Purpose: Detailed blood flow studies may contribute to improvements in carotid artery stenting. High-frame-rate contrast-enhanced ultrasound followed by particle image velocimetry (PIV), also called echoPIV, is a technique to study blood flow patterns in detail. The performance of echoPIV in presence of a stent has not yet been studied extensively. We compared the performance of echoPIV in stented and nonstented regions in an in vitro flow setup. Approach: A carotid artery stent was deployed in a vessel-mimicking phantom. High-frame-rate contrast-enhanced ultrasound images were acquired with various settings. Signal intensities of the contrast agent, velocity values, and flow profiles were calculated. Results: The results showed decreased signal intensities and correlation coefficients inside the stent, however, PIV analysis in the stent still resulted in plausible flow vectors. Conclusions: Velocity values and laminar flow profiles can be measured in vitro in stented arteries using echoPIV.

15.
Sci Rep ; 10(1): 18431, 2020 10 28.
Artículo en Inglés | MEDLINE | ID: mdl-33116234

RESUMEN

Natural and active shear wave elastography (SWE) are potential ultrasound-based techniques to non-invasively assess myocardial stiffness, which could improve current diagnosis of heart failure. This study aims to bridge the knowledge gap between both techniques and discuss their respective impacts on cardiac stiffness evaluation. We recorded the mechanical waves occurring after aortic and mitral valve closure (AVC, MVC) and those induced by acoustic radiation force throughout the cardiac cycle in four pigs after sternotomy. Natural SWE showed a higher feasibility than active SWE, which is an advantage for clinical application. Median propagation speeds of 2.5-4.0 m/s and 1.6-4.0 m/s were obtained after AVC and MVC, whereas ARF-based median speeds of 0.9-1.2 m/s and 2.1-3.8 m/s were reported for diastole and systole, respectively. The different wave characteristics in both methods, such as the frequency content, complicate the direct comparison of waves. Nevertheless, a good match was found in propagation speeds between natural and active SWE at the moment of valve closure, and the natural waves showed higher propagation speeds than in diastole. Furthermore, the results demonstrated that the natural waves occur in between diastole and systole identified with active SWE, and thus represent a myocardial stiffness in between relaxation and contraction.


Asunto(s)
Diagnóstico por Imagen de Elasticidad , Corazón/fisiología , Contracción Miocárdica , Animales , Femenino , Porcinos
16.
Ultrasound Med Biol ; 46(11): 2875-2890, 2020 11.
Artículo en Inglés | MEDLINE | ID: mdl-32843233

RESUMEN

Cardiac function and vascular function are closely related to the flow of blood within. The flow velocities in these larger cavities easily reach 1 m/s, and generally complex spatiotemporal flow patterns are involved, especially in a non-physiologic state. Visualization of such flow patterns using ultrasound can be greatly enhanced by administration of contrast agents. Tracking the high-velocity complex flows is challenging with current clinical echographic tools, mostly because of limitations in signal-to-noise ratio; estimation of lateral velocities; and/or frame rate of the contrast-enhanced imaging mode. This review addresses the state of the art in 2-D high-frame-rate contrast-enhanced echography of ventricular and deep-vessel flow, from both technological and clinical perspectives. It concludes that current advanced ultrasound equipment is technologically ready for use in human contrast-enhanced studies, thus potentially leading to identification of the most clinically relevant flow parameters for quantifying cardiac and vascular function.


Asunto(s)
Vasos Sanguíneos/diagnóstico por imagen , Medios de Contraste , Corazón/diagnóstico por imagen , Corazón/fisiopatología , Ultrasonografía/métodos , Predicción , Humanos , Imagenología Tridimensional , Flujo Sanguíneo Regional , Ultrasonografía/tendencias
17.
Ultrasound Med Biol ; 46(3): 805-817, 2020 03.
Artículo en Inglés | MEDLINE | ID: mdl-31924419

RESUMEN

Left ventricular (LV) blood flow is an inherently complex time-varying 3-D phenomenon, where 2-D quantification often ignores the effect of out-of-plane motion. In this study, we describe high frame rate 4-D echocardiographic particle image velocimetry (echo-PIV) using a prototype matrix transesophageal transducer and a dynamic LV phantom for testing the accuracy of echo-PIV in the presence of complex flow patterns. Optical time-resolved tomographic PIV (tomo-PIV) was used as a reference standard for comparison. Echo-PIV and tomo-PIV agreed on the general profile of the LV flow patterns, but echo-PIV smoothed out the smaller flow structures. Echo-PIV also underestimated the flow rates at greater imaging depths, where the PIV kernel size and transducer point spread function were large relative to the velocity gradients. We demonstrate that 4-D echo-PIV could be performed in just four heart cycles, which would require only a short breath-hold, providing promising results. However, methods for resolving high velocity gradients in regions of poor spatial resolution are required before clinical translation.


Asunto(s)
Ecocardiografía Tetradimensional , Ventrículos Cardíacos/diagnóstico por imagen , Velocidad del Flujo Sanguíneo , Fantasmas de Imagen , Reología
19.
J Biomech ; 90: 40-49, 2019 Jun 11.
Artículo en Inglés | MEDLINE | ID: mdl-31030891

RESUMEN

Left ventricular flow is intrinsically complex, three-dimensional and unsteady. Its features are susceptible to cardiovascular pathology and treatment, in particular to surgical interventions involving the valves (mitral valve replacement). To improve our understanding of intraventricular fluid mechanics and the impact of various types of prosthetic valves thereon, we have developed a custom-designed versatile left ventricular phantom with anatomically realistic moving left ventricular membrane. A biological, a tilting disc and a bileaflet valve (in two different orientations) were mounted in the mitral position and tested under the same settings. To investigate 3D flow within the phantom, a four-view tomographic particle image velocimetry setup has been implemented. The results compare side-by-side the evolution of the 3D flow topology, vortical structures and kinetic energy in the left ventricle domain during the cardiac cycle. Except for the tilting disc valve, all tested prosthetic valves induced a crossed flow path, where the outflow crosses the inflow path, passing under the mitral valve. The biological valve shows a strong jet with a peak velocity about twice as high compared to all mechanical heart valves, which makes it easier to penetrate deeply into the cavity. Accordingly, the peak kinetic energy in the left ventricle in case of the biological valve is about four times higher than the mechanical heart valves. We conclude that the tomographic particle imaging velocimetry setup provides a useful ground truth measurement of flow features and allows a comparison of the effects of different valve types on left ventricular flow patterns.


Asunto(s)
Prótesis Valvulares Cardíacas , Ventrículos Cardíacos/diagnóstico por imagen , Reología , Tomografía Computarizada por Rayos X , Humanos , Válvula Mitral/cirugía , Modelos Cardiovasculares , Diseño de Prótesis
20.
Artículo en Inglés | MEDLINE | ID: mdl-29990263

RESUMEN

Echocardiographic determination of multicomponent blood flow dynamics in the left ventricle remains a challenge. In this paper, we compare contrast enhanced, high frame rate (HFR) (1000 frames/s) echo-particle image velocimetry (ePIV) against optical particle image velocimetry (oPIV, gold standard), in a realistic left ventricular (LV) phantom. We find that ePIV compares well to oPIV, even for the high velocity inflow jet (normalized RMSE = 9% ± 1%). In addition, we perform the method of proper orthogonal decomposition, to better qualify and quantify the differences between the two modalities. We show that ePIV and oPIV resolve very similar flow structures, especially for the lowest order mode with a cosine similarity index of 86%. The coarser resolution of ePIV does result in increased variance and blurring of smaller flow structures when compared to oPIV. However, both modalities are in good agreement with each other for the modes that constitute the bulk of the kinetic energy. We conclude that HFR ePIV can accurately estimate the high velocity diastolic inflow jet and the high energy flow structures in an LV setting.


Asunto(s)
Ecocardiografía/métodos , Ventrículos Cardíacos/diagnóstico por imagen , Procesamiento de Imagen Asistido por Computador/métodos , Reología/métodos , Medios de Contraste , Ecocardiografía/instrumentación , Diseño de Equipo , Humanos , Modelos Cardiovasculares , Fantasmas de Imagen