Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
BJU Int ; 2024 Apr 24.
Artículo en Inglés | MEDLINE | ID: mdl-38659306

RESUMEN

OBJECTIVE: To investigate the feasibility of fluorescence molecular imaging (FMI), using cetuximab-800CW, as an intraoperative tool to determine surgical margins in penile squamous cell carcinoma (PSCC). PATIENTS AND METHODS: A total of 11 patients with PSCC received 75 mg cetuximab followed by 15 mg cetuximab-800CW 2 days before surgery. FMI of the whole excision specimen and tissue slices was performed. Fluorescence visualisation was correlated to histopathology. Based on tumour and healthy tissue regions of interest, mean fluorescence intensity was calculated for each individual patient. RESULTS: Significant differences between tumour and healthy mean fluorescence intensity were found with tumour-to-background ratios of a median (IQR) of 1.51 (0.99) and a mean (SD) of 1.51 (0.32) in the excision specimen and tissue slices, respectively. One patient showed a high relative fluorescence intensity with a signal-to-background ratio of 1.79, corresponding to a tumour-positive margin on fresh frozen sectioning. CONCLUSION: In this Phase I study we showed that cetuximab-800CW seems suitable to discriminate PSCC from background tissue. The tracer was well tolerated, and no false positive spots were seen.

2.
J Biomed Opt ; 29(1): 016003, 2024 01.
Artículo en Inglés | MEDLINE | ID: mdl-38235321

RESUMEN

Significance: Surgical excision is the main treatment for solid tumors in oral squamous cell carcinomas, where wide local excision (achieving a healthy tissue margin of >5 mm around the excised tumor) is the goal as it results in reduced local recurrence rates and improved overall survival. Aim: No clinical methods are available to assess the complete surgical margin intraoperatively while the patient is still on the operating table; and while recent intraoperative back-bench fluorescence-guided surgery approaches have shown promise for detecting "positive" inadequate margins (<1 mm), they have had limited success in the detection of "close" inadequate margins (1 to 5 mm). Here, a dual aperture fluorescence ratio (dAFR) approach was evaluated as a means of improving detection of close margins. Approach: The approach was evaluated on surgical specimens from patients who were administered a tumor-specific fluorescent imaging agent (cetuximab-800CW) prior to surgery. The dAFR approach was compared directly against standard wide-field fluorescence imaging and pathology measurements of margin thickness in specimens from three patients and a total of 12 margin locations (1 positive, 5 close, and 6 clear margins). Results: The area under the receiver operating characteristic curve, representing the ability to detect close compared to clear margins (>5 mm) was found to be 1.0 and 0.57 for dAFR and sAF, respectively. Improvements in dAFR were found to be statistically significant (p<0.02). Conclusions: These results provide evidence that the dAFR approach potentially improves detection of close surgical margins.


Asunto(s)
Carcinoma de Células Escamosas , Neoplasias de Cabeza y Cuello , Neoplasias de la Boca , Humanos , Carcinoma de Células Escamosas de Cabeza y Cuello/diagnóstico por imagen , Carcinoma de Células Escamosas de Cabeza y Cuello/cirugía , Carcinoma de Células Escamosas/diagnóstico por imagen , Carcinoma de Células Escamosas/cirugía , Neoplasias de la Boca/diagnóstico por imagen , Neoplasias de la Boca/cirugía , Márgenes de Escisión , Recurrencia Local de Neoplasia/diagnóstico por imagen , Recurrencia Local de Neoplasia/patología , Estudios Retrospectivos
3.
Nat Commun ; 14(1): 4952, 2023 08 16.
Artículo en Inglés | MEDLINE | ID: mdl-37587149

RESUMEN

Inadequate surgical margins occur frequently in oral squamous cell carcinoma surgery. Fluorescence molecular imaging (FMI) has been explored for intraoperative margin assessment, but data are limited to phase-I studies. In this single-arm phase-II study (NCT03134846), our primary endpoints were to determine the sensitivity, specificity and positive predictive value of cetuximab-800CW for tumor-positive margins detection. Secondary endpoints were safety, close margin detection rate and intrinsic cetuximab-800CW fluorescence. In 65 patients with 66 tumors, cetuximab-800CW was well-tolerated. Fluorescent spots identified in the surgical margin with signal-to-background ratios (SBR) of ≥2 identify tumor-positive margins with 100% sensitivity, 85.9% specificity, 58.3% positive predictive value, and 100% negative predictive value. An SBR of ≥1.5 identifies close margins with 70.3% sensitivity, 76.1% specificity, 60.5% positive predictive value, and 83.1% negative predictive value. Performing frozen section analysis aimed at the fluorescent spots with an SBR of ≥1.5 enables safe, intraoperative adjustment of surgical margins.


Asunto(s)
Carcinoma de Células Escamosas , Neoplasias de la Boca , Humanos , Carcinoma de Células Escamosas/diagnóstico por imagen , Carcinoma de Células Escamosas/cirugía , Cetuximab , Colorantes , Receptores ErbB , Márgenes de Escisión , Imagen Molecular , Neoplasias de la Boca/diagnóstico por imagen , Neoplasias de la Boca/cirugía , Radiofármacos
4.
Oral Oncol ; 134: 106099, 2022 11.
Artículo en Inglés | MEDLINE | ID: mdl-36096045

RESUMEN

OBJECTIVE: New techniques have emerged to aid in preventing inadequate margins in oral squamous cell carcinoma (OSCC) surgery, but studies comparing different techniques are lacking. Here, we compared narrow band imaging (NBI) with fluorescence molecular imaging (FMI), to study which intraoperative technique best assesses the mucosal tumour margins. MATERIALS AND METHODS: NBI was performed in vivo and borders were marked with three sutures. For FMI, patients received 75 mg of unlabelled cetuximab followed by 15 mg cetuximab-800CW intravenously-two days prior to surgery. The FMI borders were defined on the excised specimen. The NBI borders were correlated with the FMI outline and histopathology. RESULTS: Sixteen patients were included, resulting in 31 NBI and 30 FMI measurements. The mucosal border was delineated within 1 mm of the tumour border in 4/31 (13 %) of NBI and in 16/30 (53 %) FMI cases (p = 0.0008), and within 5 mm in 23/31 (74 %) of NBI and in 29/30 (97 %) of FMI cases (p = 0.0048). The median distance between the tumour border and the imaging border was significantly greater for NBI (3.2 mm, range -6.1 to 12.8 mm) than for FMI (0.9 mm, range -3.0 to 7.4 mm; p = 0.028). Submucosal extension and previous irradiation reduced NBI accuracy. CONCLUSION: Ex vivo FMI performed more accurately than in vivo NBI in mucosal margin assessment, mainly because NBI cannot detect submucosal extension. NBI adequately identified the mucosal margin especially in early-stage and not previously irradiated tumours, and may therefore be preferable in these tumours for practical and cost-related reasons.


Asunto(s)
Carcinoma de Células Escamosas , Neoplasias de Cabeza y Cuello , Neoplasias de la Boca , Carcinoma de Células Escamosas/diagnóstico por imagen , Carcinoma de Células Escamosas/patología , Carcinoma de Células Escamosas/cirugía , Cetuximab/uso terapéutico , Humanos , Márgenes de Escisión , Imagen Molecular , Neoplasias de la Boca/diagnóstico por imagen , Neoplasias de la Boca/patología , Neoplasias de la Boca/cirugía , Imagen de Banda Estrecha , Estudios Prospectivos
6.
J Nucl Med ; 63(5): 672-678, 2022 05.
Artículo en Inglés | MEDLINE | ID: mdl-34531264

RESUMEN

In most oral cancer patients, surgical treatment includes resection of the primary tumor combined with excision of lymph nodes (LNs), either for staging or for treatment. All LNs harvested during surgery require tissue processing and subsequent microscopic histopathologic assessment to determine the nodal stage. In this study, we investigated the use of the fluorescent tracer cetuximab-800CW to discriminate between tumor-positive and tumor-negative LNs before histopathologic examination. Here, we report a retrospective ad hoc analysis of a clinical trial designed to evaluate the resection margin in patients with oral squamous cell carcinoma (NCT02415881). Methods: Two days before surgery, patients were intravenously administered 75 mg of cetuximab followed by 15 mg of cetuximab-800CW, an epidermal growth factor receptor-targeting fluorescent tracer. Fluorescence images of excised, formalin-fixed LNs were obtained and correlated with histopathologic assessment. Results: Fluorescence molecular imaging of 514 LNs (61 pathologically positive nodes) could detect tumor-positive LNs ex vivo with 100% sensitivity and 86.8% specificity (area under the curve, 0.98). In this cohort, the number of LNs that required microscopic assessment was decreased by 77.4%, without missing any metastases. Additionally, in 7.5% of the LNs false-positive on fluorescence imaging, we identified metastases missed by standard histopathologic analysis. Conclusion: Our findings suggest that epidermal growth factor receptor-targeted fluorescence molecular imaging can aid in the detection of LN metastases in the ex vivo setting in oral cancer patients. This image-guided concept can improve the efficacy of postoperative LN examination and identify additional metastases, thus safeguarding appropriate postoperative therapy and potentially improving prognosis.


Asunto(s)
Carcinoma de Células Escamosas , Neoplasias de Cabeza y Cuello , Neoplasias de la Boca , Carcinoma de Células Escamosas/diagnóstico por imagen , Carcinoma de Células Escamosas/patología , Carcinoma de Células Escamosas/cirugía , Cetuximab , Receptores ErbB , Neoplasias de Cabeza y Cuello/patología , Humanos , Escisión del Ganglio Linfático , Ganglios Linfáticos/diagnóstico por imagen , Ganglios Linfáticos/patología , Ganglios Linfáticos/cirugía , Metástasis Linfática/diagnóstico por imagen , Metástasis Linfática/patología , Imagen Molecular , Neoplasias de la Boca/diagnóstico por imagen , Neoplasias de la Boca/cirugía , Estudios Retrospectivos
7.
Nat Biomed Eng ; 6(5): 503-514, 2022 05.
Artículo en Inglés | MEDLINE | ID: mdl-34750537

RESUMEN

The pathological assessment of surgical specimens during surgery can reduce the incidence of positive resection margins, which otherwise can result in additional surgeries or aggressive therapeutic regimens. To improve patient outcomes, intraoperative spectroscopic, fluorescence-based, structural, optoacoustic and radiological imaging techniques are being tested on freshly excised tissue. The specific clinical setting and tumour type largely determine whether endogenous or exogenous contrast is to be detected and whether the tumour specificity of the detected biomarker, image resolution, image-acquisition times or penetration depth are to be prioritized. In this Perspective, we describe current clinical standards for intraoperative tissue analysis and discuss how intraoperative imaging is being implemented. We also discuss potential implementations of intraoperative pathology-assisted surgery for clinical decision-making.


Asunto(s)
Neoplasias , Cirugía Asistida por Computador , Fluorescencia , Humanos , Márgenes de Escisión , Neoplasias/diagnóstico por imagen , Neoplasias/cirugía , Cirugía Asistida por Computador/métodos
8.
J Nucl Med ; 62(3): 342-347, 2021 03.
Artículo en Inglés | MEDLINE | ID: mdl-32680922

RESUMEN

Resection of soft-tissue sarcoma (STS) is accompanied by a high rate of tumor-positive surgical margins (14%-34%), which potentially lead to decreased disease-free survival. Vascular endothelial growth factor A is overexpressed in malignant tumors, including STS, and can be targeted with bevacizumab-800CW during fluorescence-guided surgery for real-time tumor detection. In this phase 1 clinical trial, we determined the feasibility, safety, and optimal dose of bevacizumab-800CW for fluorescence-guided surgery in STS for in vivo and ex vivo tumor detection. Methods: Patients with a histopathologic diagnosis of STS were included. In the dose-escalation phase, patients received bevacizumab-800CW intravenously 3 d before surgery (10, 25, and 50 mg; n = 8). In the subsequent dose-expansion phase, 7 additional patients received bevacizumab-800CW at the optimal dose. Fluorescence images were obtained in vivo and ex vivo during all stages of standard care. The optimal dose was determined by calculating in vivo and ex vivo tumor-to-background ratios (TBR) and correlating these results with histopathology. Results: Fifteen patients with STS completed this study. All tumors could be visualized during in vivo and ex vivo imaging. The optimal bevacizumab-800CW dose proved to be 10 mg, with a median in vivo TBR of 2.0 (±0.58) and a median ex vivo TBR of 2.67 (±1.6). All 7 tumor-positive margins could be observed in real time after surgical resection. Conclusion: GS using 10 mg of bevacizumab-800CW is feasible and safe for intraoperative imaging of STS, potentially allowing tumor detection and margin assessment during surgery. An additional follow-up phase 2 study is needed to confirm the diagnostic accuracy.


Asunto(s)
Imagen Óptica , Sarcoma/diagnóstico por imagen , Sarcoma/metabolismo , Cirugía Asistida por Computador , Factor A de Crecimiento Endotelial Vascular/metabolismo , Anciano , Anciano de 80 o más Años , Bevacizumab , Femenino , Humanos , Masculino , Persona de Mediana Edad , Dosis de Radiación , Sarcoma/cirugía
9.
Theranostics ; 10(12): 5357-5367, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32373217

RESUMEN

Fluorescence molecular endoscopy (FME) is an emerging technique in the field of gastroenterology that holds potential to improve diagnosis and guide therapy, by serving as a 'red-flag' endoscopic imaging technique. Here, we investigated the safety, feasibility and optimal method of administration of EMI-137, targeting c-Met, during FME in Barrett's Esophagus (BE) and report several outcome parameters for early phase FME studies. Methods: FME was performed in 15 Barrett's neoplasia patients. EMI-137 was administered to three cohorts of five patients: 0.13 mg/kg intravenously (IV); 0.09 mg/kg IV or topically at a dose of 200 µg/cm BE (n=1) or 100 µg/cm BE (n=4). Fluorescence was visualized in vivo, quantified in vivo using multi-diameter single-fiber reflectance, single-fiber fluorescence (MDSFR/SFF) spectroscopy and correlated to histopathology and immunohistochemistry. EMI-137 localization was assessed using fluorescence microscopy. Results: FME using different IV and topical doses of EMI-137 appeared to be safe and correctly identified 16/18 lesions, although modest target-to-background ratios were observed (median range of 1.12-1.50). C-Met overexpression varied between lesions, while physiological expression in the stomach-type epithelium was observed. Microscopically, EMI-137 accumulated around the neoplastic cell membranes. We identified several outcome parameters important for the validation of EMI-137 for FME: 1) the optimal administration route; 2) optimal dose and safety; 3) in vivo FME contrast; 4) quantification of intrinsic fluorescence; 5) ex vivo correlation of fluorescence, histopathology and target expression; and 6) microscopic tracer distribution. Conclusions: C-Met targeted FME using EMI-137 may not be the ideal combination to improve BE surveillance endoscopies, however the identified outcome parameters may serve as a valuable guidance for designing and performing future early phase clinical FME studies, independent of which fluorescent tracer is investigated.


Asunto(s)
Esófago de Barrett/metabolismo , Neoplasias Esofágicas/metabolismo , Proteínas Proto-Oncogénicas c-met/metabolismo , Anciano , Biopsia/métodos , Neoplasias Esofágicas/genética , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Proteínas Proto-Oncogénicas c-met/genética
10.
J Nucl Med ; 61(10): 1435-1441, 2020 10.
Artículo en Inglés | MEDLINE | ID: mdl-32198312

RESUMEN

Fluorescence molecular endoscopy (FME) is an emerging technique that has the potential to improve the 22% colorectal polyp detection miss-rate. We determined the optimal dose-to-imaging interval and safety of FME using EMI-137, a c-Met-targeted fluorescent peptide, in a population at high risk for colorectal cancer. Methods: We performed in vivo FME and quantification of fluorescence by multidiameter single-fiber reflectance/single-fiber fluorescence spectroscopy in 15 patients with a dysplastic colorectal adenoma. EMI-137 was intravenously administered (0.13 mg/kg) at a 1-, 2- or 3-h dose-to-imaging interval (n = 3 patients per cohort). Two cohorts were expanded to 6 patients on the basis of target-to-background ratios. Fluorescence was correlated to histopathology and c-Met expression. EMI-137 binding specificity was assessed by fluorescence microscopy and in vitro experiments. Results: FME using EMI-137 appeared to be safe and well tolerated. All dose-to-imaging intervals showed significantly higher fluorescence in the colorectal lesions than in surrounding tissue, with a target-to-background ratio of 1.53, 1.66, and 1.74 for the 1-, 2-, and 3-h cohorts, respectively, and a mean intrinsic fluorescence of 0.035 vs. 0.023 mm-1 (P < 0.0003), 0.034 vs. 0.021 mm-1 (P < 0.0001), and 0.033 vs. 0.019 mm-1 (P < 0.0001), respectively. Fluorescence correlated with histopathology on a macroscopic and microscopic level, with significant c-Met overexpression in dysplastic mucosa. In vitro, a dose-dependent specific binding was confirmed. Conclusion: FME using EMI-137 appeared to be safe and feasible within a 1- to 3-h dose-to-imaging interval. No clinically significant differences were observed among the cohorts, although a 1-h dose-to-imaging interval was preferred from a clinical perspective. Future studies will investigate EMI-137 for improved colorectal polyp detection during screening colonoscopies.


Asunto(s)
Adenoma/diagnóstico por imagen , Pólipos del Colon/diagnóstico por imagen , Colonoscopía/métodos , Neoplasias Colorrectales/diagnóstico por imagen , Proteínas Proto-Oncogénicas c-met/metabolismo , Espectrometría de Fluorescencia/métodos , Anciano , Pólipos del Colon/patología , Neoplasias Colorrectales/patología , Femenino , Células HT29 , Humanos , Masculino , Persona de Mediana Edad
11.
Curr Transplant Rep ; 1(3): 147-154, 2014 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-25419507

RESUMEN

Ischemia/reperfusion injury (IRI), an inherent component of transplantation, affects organ quality and transplant outcomes. Although the complexity of the pathophysiology is recognized, detailed mechanisms remain unclear, and strategies preventing the consequences of IRI have been challenging. Of critical significance appears the link between IRI, the initiation of innate immune responses, and the (potential) augmentation of adaptive immunity. An improved understanding of those complex mechanisms and interactions may pave the way for more effective treatment strategies.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...