Sensors (Basel) ; 24(1)2023 Dec 26.
Artículo en Inglés | MEDLINE | ID: mdl-38203003

RESUMEN

Health-tracking from photoplethysmography (PPG) signals is significantly hindered by motion artifacts (MAs). Although many algorithms exist to detect MAs, the corrupted signal often remains unexploited. This work introduces a novel method able to reconstruct noisy PPGs and facilitate uninterrupted health monitoring. The algorithm starts with spectral-based MA detection, followed by signal reconstruction by using the morphological and heart-rate variability information from the clean segments adjacent to noise. The algorithm was tested on (a) 30 noisy PPGs of a maximum 20 s noise duration and (b) 28 originally clean PPGs, after noise addition (2-120 s) (1) with and (2) without cancellation of the corresponding clean segment. Sampling frequency was 250 Hz after resampling. Noise detection was evaluated by means of accuracy, sensitivity, and specificity. For the evaluation of signal reconstruction, the heart-rate (HR) was compared via Pearson correlation (PC) and absolute error (a) between ECGs and reconstructed PPGs and (b) between original and reconstructed PPGs. Bland-Altman (BA) analysis for the differences in HR estimation on original and reconstructed segments of (b) was also performed. Noise detection accuracy was 90.91% for (a) and 99.38-100% for (b). For the PPG reconstruction, HR showed 99.31% correlation in (a) and >90% for all noise lengths in (b). Mean absolute error was 1.59 bpm for (a) and 1.26-1.82 bpm for (b). BA analysis indicated that, in most cases, 90% or more of the recordings fall within the confidence interval, regardless of the noise length. Optimal performance is achieved even for signals of noise up to 2 min, allowing for the utilization and further analysis of recordings that would otherwise be discarded. Thereby, the algorithm can be implemented in monitoring devices, assisting in uninterrupted health-tracking.


Asunto(s)
Algoritmos , Fotopletismografía , Artefactos , Electrocardiografía , Frecuencia Cardíaca
2.
J Pers Med ; 12(10)2022 Oct 13.
Artículo en Inglés | MEDLINE | ID: mdl-36294851

RESUMEN

Atrial cycle length (CL) is an important feature for the analysis of electrogram (EGM) characteristics acquired during catheter ablation (CA) of atrial fibrillation (AF), the commonest cardiac arrhythmia. Nevertheless, a robust ACL estimator requires the precise detection of local activation waves (LAWs), which still remains a challenge. This work aims to compare the performance in (CL) estimation, especially under fractionated EGMs, of three different LAW detection methods relying on different operation strategies. The methods are based on the hyperbolic tangent (HT) function, an adaptive amplitude threshold (AAT) and a (CL) iteration (ACLI), respectively. For each method, LAW detection has been assessed with respect to manual annotations made by two experts and performance has been estimated by confusion matrix and mean and individual (CL) error calculation by EGM types of fractionation. The influence of EGM length on the individual (CL) error has been additionally considered. For the HT method, accuracy, sensitivity and precision were 92.77-100%, while for the AAT and ACLI methods they were 78.89-99.91% for all EGM types. The CL error on the HT method was lower than AAT and ACLI methods (up to 12 ms versus up to 20 ms), with the difference being more prominent in complex EGMs. The HT method also showed the lowest dependency on EGM length, presenting the lowest and least variable error values. Therefore, the HT method achieves higher performance in (CL) estimation in comparison with previous LAW detection techniques. The high robustness and precision demonstrated by this method suggest its implementation on CA mapping devices for a more successful location of ablation targets and improved results during CA procedures.

3.
Sensors (Basel) ; 22(14)2022 Jul 18.
Artículo en Inglés | MEDLINE | ID: mdl-35891025

RESUMEN

Local activation waves (LAWs) detection in complex fractionated atrial electrograms (CFAEs) during catheter ablation (CA) of atrial fibrillation (AF), the commonest cardiac arrhythmia, is a complicated task due to their extreme variability and heterogeneity in amplitude and morphology. There are few published works on reliable LAWs detectors, which are efficient for regular or low fractionated bipolar electrograms (EGMs) but lack satisfactory results when CFAEs are analyzed. The aim of the present work is the development of a novel optimized method for LAWs detection in CFAEs in order to assist cardiac mapping and catheter ablation (CA) guidance. The database consists of 119 bipolar EGMs classified by AF types according to Wells' classification. The proposed method introduces an alternative Botteron's preprocessing technique targeting the slow and small-ampitude activations. The lower band-pass filter cut-off frequency is modified to 20 Hz, and a hyperbolic tangent function is applied over CFAEs. Detection is firstly performed through an amplitude-based threshold and an escalating cycle-length (CL) analysis. Activation time is calculated at each LAW's barycenter. Analysis is applied in five-second overlapping segments. LAWs were manually annotated by two experts and compared with algorithm-annotated LAWs. AF types I and II showed 100% accuracy and sensitivity. AF type III showed 92.77% accuracy and 95.30% sensitivity. The results of this study highlight the efficiency of the developed method in precisely detecting LAWs in CFAEs. Hence, it could be implemented on real-time mapping devices and used during CA, providing robust detection results regardless of the fractionation degree of the analyzed recordings.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Algoritmos , Fibrilación Atrial/diagnóstico , Ablación por Catéter/métodos , Técnicas Electrofisiológicas Cardíacas , Humanos
4.
J Cardiovasc Dev Dis ; 9(6)2022 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-35735805

RESUMEN

Coronary sinus (CS) catheterization is critical during catheter ablation (CA) of atrial fibrillation (AF). However, the association of CS electrical activity with atrial substrate modification has been barely investigated and mostly limited to analyses during AF. In sinus rhythm (SR), atrial substrate modification is principally assessed at a global level through P-wave analysis. Cross-correlating CS electrograms (EGMs) and P-waves' features could potentiate the understanding of AF mechanisms. Five-minute surface lead II and bipolar CS recordings before, during, and after CA were acquired from 40 paroxysmal AF patients. Features related to duration, amplitude, and heart-rate variability of atrial activations were evaluated. Heart-rate adjustment (HRA) was applied. Correlations between each P-wave and CS local activation wave (LAW) feature were computed with cross-quadratic sample entropy (CQSE), Pearson correlation (PC), and linear regression (LR) with 10-fold cross-validation. The effect of CA between different ablation steps was compared with PC. Linear correlations: poor to mediocre before HRA for analysis at each P-wave/LAW (PC: max. +18.36%, p = 0.0017, LR: max. +5.33%, p = 0.0002) and comparison between two ablation steps (max. +54.07%, p = 0.0205). HRA significantly enhanced these relationships, especially in duration (P-wave/LAW: +43.82% to +69.91%, p < 0.0001 for PC and +18.97% to +47.25%, p < 0.0001 for LR, CA effect: +53.90% to +85.72%, p < 0.0210). CQSE reported negligent correlations (0.6−1.2). Direct analysis of CS features is unreliable to evaluate atrial substrate modification due to CA. HRA substantially solves this problem, potentiating correlation with P-wave features. Hence, its application is highly recommended.

5.
J Pers Med ; 12(3)2022 Mar 14.
Artículo en Inglés | MEDLINE | ID: mdl-35330463

RESUMEN

Since the discovery of pulmonary veins (PVs) as foci of atrial fibrillation (AF), the commonest cardiac arrhythmia, investigation revolves around PVs catheter ablation (CA) results. Notwithstanding, CA process itself is rather neglected. We aim to decompose crucial CA steps: coronary sinus (CS) catheterization and the impact of left and right PVs isolation (LPVI, RPVI), separately. We recruited 40 paroxysmal AF patients undergoing first-time CA and obtained five-minute lead II and bipolar CS recordings during sinus rhythm (SR) before CA (B), after LPVI (L) and after RPVI (R). Among others, duration, amplitude and atrial-rate variability (ARV) were calculated for P-waves and CS local activation waves (LAWs). LAWs features were compared among CS channels for reliability analysis. P-waves and LAWs features were compared after each ablation step (B, L, R). CS channels: amplitude and area were different between distal/medial (p≤0.0014) and distal/mid-proximal channels (p≤0.0025). Medial and distal showed the most and least coherent values, respectively. Correlation was higher in proximal (≥93%) than distal (≤91%) areas. P-waves: duration was significantly shortened after LPVI (after L: p=0.0012, −13.30%). LAWs: insignificant variations. ARV modification was more prominent in LAWs (L: >+73.12%, p≤0.0480, R: <−33.94%, p≤0.0642). Medial/mid-proximal channels are recommended during SR. CS LAWs are not significantly affected by CA but they describe more precisely CA-induced ARV modifications. LPVI provokes the highest impact in paroxysmal AF CA, significantly modifying P-wave duration.

6.
Sensors (Basel) ; 22(1)2021 Dec 31.
Artículo en Inglés | MEDLINE | ID: mdl-35009833

RESUMEN

Atrial substrate modification after pulmonary vein isolation (PVI) of paroxysmal atrial fibrillation (pAF) can be assessed non-invasively by analyzing P-wave duration in the electrocardiogram (ECG). However, whether right (RA) and left atrium (LA) contribute equally to this phenomenon remains unknown. The present study splits fundamental P-wave features to investigate the different RA and LA contributions to P-wave duration. Recordings of 29 pAF patients undergoing first-ever PVI were acquired before and after PVI. P-wave features were calculated: P-wave duration (PWD), duration of the first (PWDon-peak) and second (PWDpeak-off) P-wave halves, estimating RA and LA conduction, respectively. P-wave onset (PWon-R) or offset (PWoff-R) to R-peak interval, measuring combined atrial/atrioventricular and single atrioventricular conduction, respectively. Heart-rate fluctuation was corrected by scaling. Pre- and post-PVI results were compared with Mann-Whitney U-test. PWD was correlated with the remaining features. Only PWD (non-scaling: Δ=-9.84%, p=0.0085, scaling: Δ=-17.96%, p=0.0442) and PWDpeak-off (non-scaling: Δ=-22.03%, p=0.0250, scaling: Δ=-27.77%, p=0.0268) were decreased. Correlation of all features with PWD was significant before/after PVI (p<0.0001), showing the highest value between PWD and PWon-R (ρmax=0.855). PWD correlated more with PWDon-peak (ρ= 0.540-0.805) than PWDpeak-off (ρ= 0.419-0.710). PWD shortening after PVI of pAF stems mainly from the second half of the P-wave. Therefore, noninvasive estimation of LA conduction time is critical for the study of atrial substrate modification after PVI and should be addressed by splitting the P-wave in order to achieve improved estimations.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Atrios Cardíacos , Humanos , Venas Pulmonares/cirugía , Recurrencia , Resultado del Tratamiento
7.
Entropy (Basel) ; 22(2)2020 Feb 19.
Artículo en Inglés | MEDLINE | ID: mdl-33286006

RESUMEN

Atrial fibrillation (AF) is currently the most common cardiac arrhythmia, with catheter ablation (CA) of the pulmonary veins (PV) being its first line therapy. Ablation of complex fractionated atrial electrograms (CFAEs) outside the PVs has demonstrated improved long-term results, but their identification requires a reliable electrogram (EGM) fractionation estimator. This study proposes a technique aimed to assist CA procedures under real-time settings. The method has been tested on three groups of recordings: Group 1 consisted of 24 highly representative EGMs, eight of each belonging to a different AF Type. Group 2 contained the entire dataset of 119 EGMs, whereas Group 3 contained 20 pseudo-real EGMs of the special Type IV AF. Coarse-grained correlation dimension (CGCD) was computed at epochs of 1 s duration, obtaining a classification accuracy of 100% in Group 1 and 84.0-85.7% in Group 2, using 10-fold cross-validation. The receiver operating characteristics (ROC) analysis for highly fractionated EGMs, showed 100% specificity and sensitivity in Group 1 and 87.5% specificity and 93.6% sensitivity in Group 2. In addition, 100% of the pseudo-real EGMs were correctly identified as Type IV AF. This method can consistently express the fractionation level of AF EGMs and provides better performance than previous works. Its ability to compute fractionation in short-time can agilely detect sudden changes of AF Types and could be used for mapping the atrial substrate, thus assisting CA procedures under real-time settings for atrial substrate modification.