Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros












Intervalo de año de publicación
1.
Braz J Cardiovasc Surg ; 37(Spec 1): 42-48, 2022 09 02.
Artículo en Inglés | MEDLINE | ID: mdl-36054001

RESUMEN

INTRODUCTION: There have been several attempts to overcome the poor graft patency of saphenous vein grafts. "No-touch" saphenous vein graft (NT-SVG) could be a solution to improve graft patency. We aimed to investigate the early and midterm outcomes of coronary artery bypass grafting (CABG) using NT-SVGs in our hospitals. METHODS: This is a retrospective study of 105 patients who underwent CABG using 130 NT-SVGs between August 2013 and December 2021. NT-SVGs were harvested with about a 5-mm margin of surrounding tissue on both sides of the vein with minimal manipulation. Then, the NT-SVG was dilated by natural arterial pressure without manual distension. After surgery, most of NT-SVGs were assessed by cardiac catheterization or multidetector computed tomography (MDCT) to determine early graft patency. Late graft assessments by MDCT were performed about every five years after surgery. RESULTS: The early graft patency of NT-SVGs was 100% (125/125); however, two cases of graft twisting were found. Both cases spontaneously resolved. Leg wound infections of NT-SVG harvesting site were seen in 6.2% of patients. Peripheral neuropathy of the legs such as skin numbness and tingling were frequently observed, which lasted up to one year, but no more than two years after surgery. The midterm graft patency of NT-SVGs was excellent (five-year patency of NT-SVGs was 95.8%). CONCLUSION: The early and midterm graft patency of NT-SVGs was satisfactory. Although leg wound complications can be seen on the harvesting NT-SVG site, the "no-touch" harvesting technique of SVG could improve graft patency and clinical outcomes of CABG.


Asunto(s)
Puente de Arteria Coronaria , Vena Safena , Puente de Arteria Coronaria/métodos , Humanos , Japón , Estudios Retrospectivos , Vena Safena/trasplante , Grado de Desobstrucción Vascular
2.
Rev. bras. cir. cardiovasc ; 37(spe1): 42-48, 2022. tab, graf
Artículo en Inglés | LILACS-Express | LILACS | ID: biblio-1407345

RESUMEN

ABSTRACT Introduction: There have been several attempts to overcome the poor graft patency of saphenous vein grafts. "No-touch" saphenous vein graft (NT-SVG) could be a solution to improve graft patency. We aimed to investigate the early and midterm outcomes of coronary artery bypass grafting (CABG) using NT-SVGs in our hospitals. Methods: This is a retrospective study of 105 patients who underwent CABG using 130 NT-SVGs between August 2013 and December 2021. NT-SVGs were harvested with about a 5-mm margin of surrounding tissue on both sides of the vein with minimal manipulation. Then, the NT-SVG was dilated by natural arterial pressure without manual distension. After surgery, most of NT-SVGs were assessed by cardiac catheterization or multidetector computed tomography (MDCT) to determine early graft patency. Late graft assessments by MDCT were performed about every five years after surgery. Results: The early graft patency of NT-SVGs was 100% (125/125); however, two cases of graft twisting were found. Both cases spontaneously resolved. Leg wound infections of NT-SVG harvesting site were seen in 6.2% of patients. Peripheral neuropathy of the legs such as skin numbness and tingling were frequently observed, which lasted up to one year, but no more than two years after surgery. The midterm graft patency of NT-SVGs was excellent (five-year patency of NT-SVGs was 95.8%). Conclusion: The early and midterm graft patency of NT-SVGs was satisfactory. Although leg wound complications can be seen on the harvesting NT-SVG site, the "no-touch" harvesting technique of SVG could improve graft patency and clinical outcomes of CABG.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...