Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 116
Filtrar
1.
Respiration ; : 1, 2024 Jun 10.
Artículo en Inglés | MEDLINE | ID: mdl-38857571

RESUMEN

INTRODUCTION: Patients with central neoplasms and haemoptysis show low survival rates. Symptom control without recurrence 48 h after bronchoscopic interventions may improve the prognosis of these patients. Bronchoscopic argon plasma coagulation (APC) is a useful technique for endobronchial management of haemoptysis in patients with central malignancies. Nevertheless, limited data are available in the literature on its efficacy and safety and the main predictors of success are still unclear. METHODS: An observational, prospective, single-centre cohort study was carried out to assess the efficacy (i.e., immediate bleeding cessation without recurrence during the following 48 h) of bronchoscopic APC in the treatment of patients with haemoptysis caused by endobronchial malignancies and the main predictors of success. RESULTS: A total of 76 patients with median age 75 years (interquartile range: 65-79) were enrolled. 67 (88.2%) patients had bleeding cessation without recurrence 48 h after bronchoscopic APC. A low rate of non-serious adverse events (5.3%) was recorded and a low (7.6%) recurrence rate of haemoptysis at 3.5 months after the procedure was also shown. No clinical, demographic and endoscopic variables related to a successful procedure at 48 h were found. CONCLUSION: This study demonstrates that bronchoscopic APC is an effective procedure in the treatment of patients with haemoptysis caused by endobronchial malignancies, regardless of the clinical characteristics of the patients, the endoscopic and histological features of the neoplasm and the severity of the symptom. Furthermore, it shows a low rate of complications and long-term efficacy in bleeding control.

2.
Lung Cancer ; 193: 107847, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38889499

RESUMEN

BACKGROUND: Direct comparison of tumor microenvironment of matched lung cancer biopsies and pleural effusions (PE) from the same patients is critical in understanding tumor biology but has not been performed. This is the first study to compare the lung cancer and PE microenvironment by single-cell RNA sequencing (scRNA-seq). METHODS: Matched lung cancer biopsies and PE were obtained prospectively from ten patients. We isolated CD45+ cells and performed scRNA-seq to compare the biopsies and PE. RESULTS: PE had a higher proportion of CD4+ T cells but lower proportion of CD8+ T cells (False detection rate, FDR = 0.0003) compared to biopsies. There was a higher proportion of naïve CD4+ T cells (FDR = 0.04) and naïve CD8+ T cells (FDR = 0.0008) in PE vs. biopsies. On the other hand, there was a higher proportion of Tregs (FDR = 0.04), effector CD8+ (FDR = 0.006), and exhausted CD8+ T cells (FDR = 0.01) in biopsies. The expression of inflammatory genes in T cells was increased in biopsies vs. PE, including TNF, IFN-É£, IL-1R1, IL-1R2, IL-2, IL-12RB2, IL-18R1, and IL-18RAP (FDR = 0.009, 0.013, 0.029, 0.043, 0.009, 0.013, 0.004, and 0.003, respectively). The gene expression of exhaustion markers in T cells was also increased in tumor biopsies including PDCD1, CTLA4, LAG 3, HAVCR2, TIGIT, and CD160 (FDR = 0.008, 0.003, 0.002, 0.011, 0.006, and 0.049, respectively). CONCLUSIONS: There is a higher proportion of naïve T cells and lower proportion of exhausted T cells and Tregs in PE compared to lung cancer biopsies, which can be leveraged for prognostic and therapeutic applications.


Asunto(s)
Neoplasias Pulmonares , Análisis de la Célula Individual , Microambiente Tumoral , Humanos , Neoplasias Pulmonares/genética , Neoplasias Pulmonares/patología , Microambiente Tumoral/inmunología , Microambiente Tumoral/genética , Análisis de la Célula Individual/métodos , Masculino , Femenino , Linfocitos T CD8-positivos/inmunología , Anciano , Persona de Mediana Edad , Linfocitos T CD4-Positivos/inmunología , Análisis de Secuencia de ARN , Biopsia , Derrame Pleural/patología , Derrame Pleural/genética , Derrame Pleural Maligno/genética , Derrame Pleural Maligno/patología , Estudios Prospectivos
3.
Artículo en Inglés | MEDLINE | ID: mdl-38878052

RESUMEN

OBJECTIVE: Lung cancers that present as radiographic subsolid nodules represent a subtype with distinct biological behavior and outcomes. The objective of this document is to review the existing literature and report consensus among a group of multidisciplinary experts, providing specific recommendations for the clinical management of subsolid nodules. METHODS: The American Association for Thoracic Surgery Clinical Practice Standards Committee assembled an international, multidisciplinary expert panel composed of radiologists, pulmonologists, and thoracic surgeons with established expertise in the management of subsolid nodules. A focused literature review was performed with the assistance of a medical librarian. Expert consensus statements were developed with class of recommendation and level of evidence for each of 4 main topics: (1) definitions of subsolid nodules (radiology and pathology), (2) surveillance and diagnosis, (3) surgical interventions, and (4) management of multiple subsolid nodules. Using a modified Delphi method, the statements were evaluated and refined by the entire panel. RESULTS: Consensus was reached on 17 recommendations. These consensus statements reflect updated insights on subsolid nodule management based on the latest literature and current clinical experience, focusing on the correlation between radiologic findings and pathological classifications, individualized subsolid nodule surveillance and surgical strategies, and multimodality therapies for multiple subsolid lung nodules. CONCLUSIONS: Despite the complex nature of the decision-making process in the management of subsolid nodules, consensus on several key recommendations was achieved by this American Association for Thoracic Surgery expert panel. These recommendations, based on evidence and a modified Delphi method, provide guidance for thoracic surgeons and other medical professionals who care for patients with subsolid nodules.

4.
Chest ; 165(4): 1009-1019, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38030063

RESUMEN

BACKGROUND: Accurate assessment of the probability of lung cancer (pCA) is critical in patients with pulmonary nodules (PNs) to help guide decision-making. We sought to validate a clinical-genomic classifier developed using whole-transcriptome sequencing of nasal epithelial cells from patients with a PN ≤ 30 mm who smoke or have previously smoked. RESEARCH QUESTION: Can the pCA in individuals with a PN and a history of smoking be predicted by a classifier that uses clinical factors and genomic data from nasal epithelial cells obtained by cytologic brushing? STUDY DESIGN AND METHODS: Machine learning was used to train a classifier using genomic and clinical features on 1,120 patients with PNs labeled as benign or malignant established by a final diagnosis or a minimum of 12 months of radiographic surveillance. The classifier was designed to yield low-, intermediate-, and high-risk categories. The classifier was validated in an independent set of 312 patients, including 63 patients with a prior history of cancer (other than lung cancer), comparing the classifier prediction with the known clinical outcome. RESULTS: In the primary validation set, sensitivity and specificity for low-risk classification were 96% and 42%, whereas sensitivity and specificity for high-risk classification was 58% and 90%, respectively. Sensitivity was similar across stages of non-small cell lung cancer, independent of subtype. Performance compared favorably with clinical-only risk models. Analysis of 63 patients with prior cancer showed similar performance as did subanalyses of patients with light vs heavy smoking burden and those eligible for lung cancer screening vs those who were not. INTERPRETATION: The nasal classifier provides an accurate assessment of pCA in individuals with a PN ≤ 30 mm who smoke or have previously smoked. Classifier-guided decision-making could lead to fewer diagnostic procedures in patients without cancer and more timely treatment in patients with lung cancer.


Asunto(s)
Carcinoma de Pulmón de Células no Pequeñas , Neoplasias Pulmonares , Nódulos Pulmonares Múltiples , Humanos , Neoplasias Pulmonares/patología , Carcinoma de Pulmón de Células no Pequeñas/diagnóstico , Detección Precoz del Cáncer , Nódulos Pulmonares Múltiples/diagnóstico , Nódulos Pulmonares Múltiples/patología , Probabilidad
5.
medRxiv ; 2023 Nov 23.
Artículo en Inglés | MEDLINE | ID: mdl-38045245

RESUMEN

Background: Lung nodule incidence is increasing. Many nodules require biopsy to discriminate between benign and malignant etiologies. The gold-standard for minimally invasive biopsy, computed tomography-guided transthoracic needle biopsy (CT-TTNB), has never been directly compared to navigational bronchoscopy, a modality which has recently seen rapid technological innovation and is associated with improving diagnostic yield and lower complication rate. Current estimates of the diagnostic utility of both modalities are based largely on non-comparative data with significant risk for selection, referral, and publication biases. Methods: The VERITAS trial (na V igation E ndoscopy to R each Indeterminate lung nodules versus T ransthoracic needle A spiration, a randomized controlled S tudy) is a multicenter, 1:1 randomized, parallel-group trial designed to ascertain whether electromagnetic navigational bronchoscopy with integrated digital tomosynthesis is noninferior to CT-TTNB for the diagnosis of peripheral lung nodules 10-30 mm in diameter with pre-test probability of malignancy of at least 10%. The primary endpoint is diagnostic accuracy through 12 months follow-up. Secondary endpoints include diagnostic yield, complication rate, procedure duration, need for additional invasive diagnostic procedures, and radiation exposure. Discussion: The results of this rigorously designed trial will provide high-quality data regarding the management of lung nodules, a common clinical entity which often represents the earliest and most treatable stage of lung cancer. Several design challenges are described. Notably, all nodules are centrally reviewed by an independent interventional pulmonology and radiology adjudication panel relying on pre-specified exclusions to ensure enrolled nodules are amenable to sampling by both modalities while simultaneously protecting against selection bias favoring either modality. Conservative diagnostic yield and accuracy definitions with pre-specified criteria for what non-malignant findings may be considered diagnostic were chosen to avoid inflation of estimates of diagnostic utility. Trial registration: ClinicalTrials.gov NCT04250194.

6.
Am J Respir Crit Care Med ; 208(8): 837-845, 2023 Oct 15.
Artículo en Inglés | MEDLINE | ID: mdl-37582154

RESUMEN

Rationale: Strict adherence to procedural protocols and diagnostic definitions is critical to understand the efficacy of new technologies. Electromagnetic navigational bronchoscopy (ENB) for lung nodule biopsy has been used for decades without a solid understanding of its efficacy, but offers the opportunity for simultaneous tissue acquisition via electromagnetic navigational transthoracic biopsy (EMN-TTNA) and staging via endobronchial ultrasound (EBUS). Objective: To evaluate the diagnostic yield of EBUS, ENB, and EMN-TTNA during a single procedure using a strict a priori definition of diagnostic yield with central pathology adjudication. Methods: A prospective, single-arm trial was conducted at eight centers enrolling participants with pulmonary nodules (<3 cm; without computed tomography [CT]- and/or positron emission tomography-positive mediastinal lymph nodes) who underwent a staged procedure with same-day CT, EBUS, ENB, and EMN-TTNA. The procedure was staged such that, when a diagnosis had been achieved via rapid on-site pathologic evaluation, the procedure was ended and subsequent biopsy modalities were not attempted. A study finding was diagnostic if an independent pathology core laboratory confirmed malignancy or a definitive benign finding. The primary endpoint was the diagnostic yield of the combination of CT, EBUS, ENB, and EMN-TTNA. Measurements and Main Results: A total of 160 participants at 8 centers with a mean nodule size of 18 ± 6 mm were enrolled. The diagnostic yield of the combined procedure was 59% (94 of 160; 95% confidence interval [CI], 51-66%). Nodule regression was found on same-day CT in 2.5% of cases (4 of 160; 95% CI, 0.69-6.3%), and EBUS confirmed malignancy in 7.1% of cases (11 of 156; 95% CI, 3.6-12%). The yield of ENB alone was 49% (74 of 150; 95% CI, 41-58%), that of EMN-TTNA alone was 27% (8 of 30; 95% CI, 12-46%), and that of ENB plus EMN-TTNA was 53% (79 of 150; 95% CI, 44-61%). Complications included a pneumothorax rate of 10% and a 2% bleeding rate. When EMN-TTNA was performed, the pneumothorax rate was 30%. Conclusions: The diagnostic yield for ENB is 49%, which increases to 59% with the addition of same-day CT, EBUS, and EMN-TTNA, lower than in prior reports in the literature. The high complication rate and low diagnostic yield of EMN-TTNA does not support its routine use. Clinical trial registered with www.clinicaltrials.gov (NCT03338049).

7.
Respiration ; 102(7): 495-502, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37290401

RESUMEN

BACKGROUND: Advances in bronchoscopy have impacted the practice patterns in the sampling of thoracic lymph nodes and lung lesions. OBJECTIVES: The aim of the study was to study the trends in utilization of mediastinoscopy, transthoracic needle aspiration (TTNA), and bronchoscopic transbronchial sampling. METHODS: We conducted an analysis of patient claims for sampling of thoracic lymph nodes and lung lesions in the Medicare population and a sample of the commercial population between 2016 and 2020. We used Current Procedural Terminology codes to identify mediastinoscopy, TTNA, and bronchoscopic transbronchial sampling. Post-procedural pneumothorax rates were assessed by procedure type including subset analyses for patients with chronic obstructive pulmonary disease (COPD). RESULTS: Between 2016 and 2020, utilization of mediastinoscopy has decreased in both the Medicare and commercial populations (-47.3% and -65.4%, respectively), while linear endobronchial ultrasound (EBUS)-guided transbronchial needle aspiration (TBNA) has increased only in the Medicare population (+28.2%). Percutaneous lung biopsy claims dropped by -17.0% in the Medicare and -41.22% in the commercial population. The use of bronchoscopic TBNA and forceps biopsy declined in both populations, but the reliance on a combination of guided technology (radial EBUS-guided and navigation) grew in the Medicare and commercial populations (+76.3% and +25%). Rates of post-procedural pneumothorax were significantly higher following percutaneous biopsy compared to bronchoscopic transbronchial biopsy. CONCLUSIONS: Linear EBUS-guided sampling has surpassed mediastinoscopy as the technique for sampling thoracic lymph nodes. Transbronchial lung sampling is increasingly being performed with guidance technology. This trend is aligned with favorable rates of post-procedure pneumothorax for transbronchial biopsy.


Asunto(s)
Neoplasias Pulmonares , Neumotórax , Estados Unidos/epidemiología , Humanos , Anciano , Neoplasias Pulmonares/patología , Neumotórax/epidemiología , Neumotórax/etiología , Neumotórax/patología , Medicare , Pulmón/diagnóstico por imagen , Ganglios Linfáticos/patología , Biopsia por Aspiración con Aguja Fina Guiada por Ultrasonido Endoscópico/métodos , Broncoscopía/métodos , Estadificación de Neoplasias , Sensibilidad y Especificidad
8.
Respiration ; 102(5): 370-376, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36996776

RESUMEN

BACKGROUND: Peripheral bronchoscopy is often performed to biopsy peripheral pulmonary lesions. Despite technological advancements to improve reach and access to the lung periphery, the diagnostic yield of peripheral bronchoscopy has been inconsistent, and challenging, particularly for lesions that are adjacent to peripheral bronchi. Current biopsy instruments are reliant on the catheter or scope to align properly with targeted lesions. OBJECTIVES: This study evaluates the feasibility of using a steerable biopsy needle to gain access to peripheral tumor targets in a cadaveric model. METHODS: Simulated tumor targets 10-30 mm in axial diameter were placed into human cadavers. Bronchoscopy was performed using a 4.2 mm OD flexible bronchoscope, CT-anatomic correlation, and multi-planar fluoroscopy for lesion localization. Once at the targeted location, a steerable needle was deployed and the needle position was determined to be in the central zone, peripheral zone, or outside of the lesion by cone beam CT imaging. If the needle position was within the lesion, a fiducial marker was deployed to mark the needle position, and the needle was articulated and/or rotated in an attempt to place another fiducial marker into a different location within the same lesion. If the needle was outside of the lesion, the bronchoscopist was provided with two additional attempts to gain access to the lesion. RESULTS: Fifteen tumor targets were placed with a mean lesion size of 20.4 mm. The majority of lesions were located in the upper lobes. One fiducial marker was placed in 93.3% of lesions and a second fiducial marker was successfully placed in 80% of lesions. A fiducial marker was placed within the central zone in 60% of lesions. CONCLUSION: The steerable needle was successfully placed within 93% of targeted lesions 10-30 mm in diameter in a cadaveric model, with the ability steer the instrument into another portion of the lesion in 80% of cases. The ability to steer and control needle positioning toward and within peripheral lesions may complement existing catheter and scope technology during peripheral diagnostic procedures.


Asunto(s)
Neoplasias Pulmonares , Humanos , Neoplasias Pulmonares/patología , Estudios de Factibilidad , Pulmón/patología , Biopsia , Broncoscopía/métodos
9.
J Bronchology Interv Pulmonol ; 30(2): 129-134, 2023 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-36825802

RESUMEN

BACKGROUND: Interventional pulmonology (IP) is a growing field that has not yet been recognized by the American Board of Medical Specialties or incorporated into national benchmark organizations. As a result, there is a lack of data on IP practice patterns, physicians' compensation and productivity targets. METHODS: We sent an anonymous survey to 647 current or past physician members of the AABIP. Domains included demographics, training background, academic rank, practice settings, work relative value unit (wRVU) targets, salary, and career satisfaction. RESULTS: The response rate to the survey was 28.3%; 17.8% were female. The median salary for IP faculty in academic institutions was $320,000 for assistant professors, $338,000 for associate professors, and $350,000 for full professors. Salaries were lower for women than for men in academic practice, even after adjusting for the number of years in practice (mean salary difference after adjustment $57,175, 95% CI: $19,585-$94,764, P =0.003). The median salary for private practice was higher at $428,000. Among respondents that used wRVU targets, the median targets for academic and private practice were 5500 and 6300, respectively. The majority of IP physicians are satisfied with their career choice. CONCLUSIONS: Productivity targets in IP are used less than half the time, and when they are used, they are set in line with the lower wRVU of IP procedures. IP compensation is higher than that of general pulmonary medicine, as reported by national benchmark associations. In academic practices, gender differences in salaries were found.


Asunto(s)
Médicos , Neumología , Masculino , Humanos , Femenino , Estados Unidos , Benchmarking , Docentes Médicos , Salarios y Beneficios
10.
Chest ; 163(5): 1193-1200, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-36627080

RESUMEN

Value-based care aims to improve the health outcomes of patients, eliminate waste and unwarranted clinical variation, and reduce the total cost of care. Professional medical societies have put forward guidelines to raise awareness on unproven practice patterns (Choosing Wisely Campaign), and payers have sought to replace the traditional fee-for-service payment models with value-based contracts that share financial gains or losses based on achieving high-quality outcomes and lowering the cost of care. Regardless of whether their practices are engaged in value-based arrangements, chest physicians should seek understanding of these principles, participate in designing and implementing practical and impactful high-value initiatives in their practices, and have a national voice on the path forward.


Asunto(s)
Planes de Aranceles por Servicios , Médicos , Humanos , Pautas de la Práctica en Medicina
11.
Chest ; 164(1): 252-261, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-36693563

RESUMEN

BACKGROUND: Pleural cytology is currently used to assess targetable mutations in patients with advanced lung adenocarcinoma. However, it is fraught with low diagnostic yield. RESEARCH QUESTION: Can pleural cell-free DNA (cfDNA) be used to assess targetable mutations in lung adenocarcinoma patients with malignant pleural effusions (MPE)? STUDY DESIGN AND METHODS: Patients with lung adenocarcinoma MPE were recruited prospectively between January 2017 and September 2021. Oncogenic mutations were assessed by treating providers using pleural fluid cytology or lung cancer biopsies. Pleural and plasma cfDNA were used to assess the mutations using next-generation sequencing (NGS). RESULTS: Fifty-four pleural fluid samples were collected from 42 patients. The diagnostic yield to detect oncogenic mutations for pleural cfDNA, pleural cytology, biopsy, and plasma cfDNA was 49/54 (90.7%), 16/33 (48.5%), 22/25 (88%), and 24/32 (75%), respectively, P < .001. The agreement of mutations in positive samples between pleural cfDNA and pleural cytology was 100%, whereas the agreement of pleural cfDNA with biopsies was 89.4%. The median concentration (interquartile range) of pleural cfDNA was higher than plasma: 28,444 (4,957-67,051) vs 2,966.5 (2,167-5,025) copies of amplifiable DNA per mL, P < .01. Median of 5 mL (interquartile range, 4.5-5) of pleural fluid supernatant was adequate for cfDNA testing. INTERPRETATION: The diagnostic yield of pleural cfDNA NGS for oncogenic mutations in lung adenocarcinoma patients is comparable to tumor biopsies and higher than pleural cytology and plasma cfDNA. The pleural cfDNA can be longitudinally collected, can be readily incorporated in clinical workflow, and may decrease the need for additional biopsies.


Asunto(s)
Adenocarcinoma del Pulmón , Ácidos Nucleicos Libres de Células , Neoplasias Pulmonares , Derrame Pleural Maligno , Humanos , Ácidos Nucleicos Libres de Células/genética , Adenocarcinoma del Pulmón/diagnóstico , Adenocarcinoma del Pulmón/genética , Neoplasias Pulmonares/diagnóstico , Neoplasias Pulmonares/genética , Neoplasias Pulmonares/tratamiento farmacológico , Derrame Pleural Maligno/diagnóstico , Derrame Pleural Maligno/genética , Mutación
12.
J Bronchology Interv Pulmonol ; 30(2): 144-154, 2023 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-35993570

RESUMEN

BACKGROUND: E-cigarette or vaping-use related acute lung injury (EVALI) is a spectrum of radiographic and histologic patterns consistent with acute to subacute lung injury. However, limited data exist characterizing bronchoalveolar lavage (BAL) findings. The goal of this study is to further define the pathologic findings from BAL and biopsy samples of subjects with EVALI across 7 institutions. METHODS: A multicentered registry of patients admitted with EVALI who underwent flexible bronchoscopy with BAL+/-transbronchial biopsy from July 2019 to April 2021 was compiled for retrospective evaluation from 7 academic institutions throughout the United States. Radiographic and cytopathologic findings and frequencies were correlated with the substance vaped. RESULTS: Data from 21 subjects (42.9% women) who were predominantly White (76.2%) with a median age of 25 years (range, 16 to 68) with EVALI were included in this study. Sixteen patients (76.2%) reported use of tetrahydrocannabinol; the remainder used nicotine. BAL was performed in 19 of the 21 subjects, and transbronchial lung biopsy was performed in 7 subjects. BAL findings revealed neutrophilic predominance (median, 59.5%, range, 3.1 to 98) in most cases. Ten BAL samples demonstrated pulmonary eosinophilia ranging from 0.2% to 49.1% with one subject suggesting a diagnosis of acute eosinophilic pneumonia associated with the use of e-cigarettes. Lipid-laden macrophages were noted in 10 of 15 reports (66.7%). Transbronchial biopsy most frequently demonstrated patterns of organizing pneumonia (57.1%). CONCLUSION: EVALI-associated BAL findings typically demonstrate a spectrum of nonspecific inflammatory changes, including neutrophilia, lipid-laden macrophages, and in some cases eosinophilia.


Asunto(s)
Sistemas Electrónicos de Liberación de Nicotina , Lesión Pulmonar , Humanos , Estados Unidos/epidemiología , Femenino , Adolescente , Adulto Joven , Adulto , Persona de Mediana Edad , Anciano , Masculino , Lesión Pulmonar/diagnóstico por imagen , Lesión Pulmonar/etiología , Lesión Pulmonar/patología , Estudios Retrospectivos , Lavado Broncoalveolar , Dimercaprol , Lípidos
13.
PLoS One ; 17(7): e0268567, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35830375

RESUMEN

The Percepta Genomic Sequencing Classifier (GSC) was developed to up-classify as well as down-classify the risk of malignancy for lung lesions when bronchoscopy is non-diagnostic. We evaluated the performance of Percepta GSC in risk re-classification of indeterminate lung lesions. This multicenter study included individuals who currently or formerly smoked undergoing bronchoscopy for suspected lung cancer from the AEGIS I/ II cohorts and the Percepta Registry. The classifier was measured in normal-appearing bronchial epithelium from bronchial brushings. The sensitivity, specificity, and predictive values were calculated using predefined thresholds. The ability of the classifier to decrease unnecessary invasive procedures was estimated. A set of 412 patients were included in the validation (prevalence of malignancy was 39.6%). Overall, 29% of intermediate-risk lung lesions were down-classified to low-risk with a 91.0% negative predictive value (NPV) and 12.2% of intermediate-risk lesions were up-classified to high-risk with a 65.4% positive predictive value (PPV). In addition, 54.5% of low-risk lesions were down-classified to very low risk with >99% NPV and 27.3% of high-risk lesions were up-classified to very high risk with a 91.5% PPV. If the classifier results were used in nodule management, 50% of patients with benign lesions and 29% of patients with malignant lesions undergoing additional invasive procedures could have avoided these procedures. The Percepta GSC is highly accurate as both a rule-out and rule-in test. This high accuracy of risk re-classification may lead to improved management of lung lesions.


Asunto(s)
Broncoscopía , Neoplasias Pulmonares , Biopsia , Broncoscopía/métodos , Mapeo Cromosómico , Humanos , Neoplasias Pulmonares/diagnóstico , Neoplasias Pulmonares/genética , Mucosa Respiratoria
14.
J Bronchology Interv Pulmonol ; 29(3): 224-237, 2022 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-35698281

RESUMEN

BACKGROUND: Pharmacologic therapeutics for advanced emphysema have limited benefit. Bronchoscopic lung volume reduction with endobronchial valves (EBVs) have reported improvements in lung function, breathlessness, and quality of life through randomized clinical trials, with less morbidity as comparted to Surgical Lung volume Reduction. We here present a Meta-analysis and systematic review of bronchoscopic lung volume reduction in advanced chronic obstructive lung disease patients. METHODS: PubMed (NLM), Embase (Elsevier), and Web of Science (Clarivate Analytics) search was conducted using a combination of keywords and subject headings. The search was confined to the last 15 years and was completed on October 23, 2020. Only placebo-controlled randomized control trials of emphysema patients with EBV were included. Quality assessment was done by 2 independent reviewers. RESULTS: Nine studies were included for the meta-analysis with a total number of 1383 patients of whom 888 received EBV and 495 standard of care (SOC) medications. Our Metanalysis show statistically significant improvement in forced expiratory volume in first second, percentage forced expiratory volume in first second, St. George's respiratory questionnaire, and 6-minute walk distance in EBV group compared with SOC. Residual volume had statistically significant reduction after EBV placement compared with SOC. These differences continued to be present during short-term (<=6 mo) and long-term follow-up (>=6 mo). These improvements were even higher when the EBV patients'. Collateral ventilation was negative/fissure was intact (CV-/FI >90%). The rate of hemoptysis and pneumothorax was higher in the EBV group compared with SOC, however, did not lead to increased fatal outcomes. CONCLUSION: In conclusion, EBV has favorable effects on patients' outcomes in patients who have heterogeneous emphysema particularly with no collateral ventilation.


Asunto(s)
Enfisema , Enfisema Pulmonar , Broncoscopía/efectos adversos , Enfisema/etiología , Volumen Espiratorio Forzado , Humanos , Neumonectomía/efectos adversos , Calidad de Vida , Resultado del Tratamiento
15.
J Bronchology Interv Pulmonol ; 29(3): 171-178, 2022 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-35730777

RESUMEN

BACKGROUND: The use of mapping to guide peripheral lung navigation (PLN) represents an advance in the management of peripheral pulmonary lesions (PPL). Software has been developed to virtually reconstruct computed tomography images into 3-dimensional airway maps and generate navigation pathways to target PPL. Despite this there remain significant gaps in understanding the factors associated with navigation success and failure including the cartographic performance characteristics of these software algorithms. This study was designed to determine whether differences exist when comparing PLN mapping platforms. METHODS: An observational direct comparison was performed to evaluate navigation planning software packages for the lung. The primary endpoint was distance from the terminal end of the virtual navigation pathway to the target PPL. Secondary endpoints included distal virtual and segmental airway generations built to the target and/or in each lung. RESULTS: Twenty-five patient chest computed tomography scans with 41 PPL were evaluated. Virtual airway and navigation pathway maps were generated for each scan/nodule across all platforms. Virtual navigation pathway comparison revealed differences in the distance from the terminal end of the navigation pathway to the target PPL (robotic bronchoscopy 9.4 mm vs. tip-tracked electromagnetic navigation 14.2 mm vs. catheter based electromagnetic navigation 17.2 mm, P=0.0005) and in the generation of complete distal airway maps. CONCLUSION: Comparing PLN planning software revealed significant differences in the generation of virtual airway and navigation maps. These differences may play an unrecognized role in the accurate PLN and biopsy of PPL. Further prospective trials are needed to quantify the effect of the differences reported.


Asunto(s)
Neoplasias Pulmonares , Broncoscopía/métodos , Fenómenos Electromagnéticos , Humanos , Pulmón/diagnóstico por imagen , Pulmón/patología , Neoplasias Pulmonares/diagnóstico por imagen , Neoplasias Pulmonares/patología , Neoplasias Pulmonares/cirugía , Tomografía Computarizada por Rayos X
16.
Ann Am Thorac Soc ; 19(10): 1722-1729, 2022 10.
Artículo en Inglés | MEDLINE | ID: mdl-35363591

RESUMEN

Rationale: Tunneled, indwelling pleural catheters (IPCs) have been demonstrated to be an effective method of managing malignant pleural effusions. However, they allow pleurodesis and can therefore be removed in only a subset of patients. A novel, silver nitrate-coated IPC was developed with the intention of creating a rapid, effective chemical pleurodesis to allow more frequent and earlier catheter removal. This study represents the pivotal clinical trial evaluating that catheter versus the standard IPC. Objectives: To compare the efficacy of a novel silver nitrate-eluting indwelling pleural catheter (SNCIPC) with that of a standard, uncoated catheter. Methods: The SWIFT [A Pivotal Multi-Center, Randomized, Controlled, Single-Blinded Study Comparing the Silver Nitrate-Coated Indwelling Pleural Catheter (SNCIPC) to the Uncoated PleurX® Pleural Catheter for the Management of Symptomatic, Recurrent, Malignant Pleural Effusions] trial was a multicenter, parallel-group, randomized, controlled, patient-blind trial. Central randomization occurred according to a computer-generated schedule, stratified by site. Recruitment was from 17 secondary or tertiary care hospitals in the United States and 3 in the United Kingdom and included adult patients with malignant pleural effusion needing drainage, without evidence of lung entrapment or significant loculation. The intervention group underwent insertion of an SNCIPC with maximal fluid drainage, followed by a tapering drainage schedule. The control group received a standard, uncoated catheter. Follow-up was conducted until 90 days. The primary outcome measure was pleurodesis efficacy, measured by fluid drainage, at 30 days. Results: A total of 119 patients were randomized. Five withdrew before receiving treatment, leaving 114 (77 SNCIPC, 37 standard IPC) for analysis. The mean age was 66 years (standard deviation, 11). More patients in the SNCIPC group were inpatients (39% vs. 14%; P = 0.009). For the primary outcome, pleurodesis rates were 12 (32%) of 37 in the control group and 17 (22%) of 77 in the SNCIPC group (rate difference, -0.10; 95% confidence interval, -0.30 to 0.09). Median time to pleurodesis was 11 days (interquartile range, 9 to 23) in the control group and 4 days (interquartile range, 2 to 15) in the SNCIPC group. No significant difference in treatment-related adverse event rates was noted between groups. Conclusions: The SNCIPC did not improve pleurodesis efficacy compared with a standard IPC. This study does not support the wider use of the SNCIPC device. Clinical trial registered with www.clinicaltrials.gov (NCT02649894).


Asunto(s)
Derrame Pleural Maligno , Adulto , Anciano , Catéteres de Permanencia/efectos adversos , Drenaje/métodos , Humanos , Derrame Pleural Maligno/etiología , Pleurodesia/métodos , Nitrato de Plata , Talco/uso terapéutico
17.
Respiration ; 101(5): 485-493, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35344969

RESUMEN

BACKGROUND: Despite recent advances in guided bronchoscopy, the yield of bronchoscopic biopsy of a peripheral pulmonary nodule (PPN) remains highly variable. OBJECTIVE: The aim of the study was to evaluate which features of robotic assisted bronchoscopy (RAB) contribute to a successful biopsy in a cadaver model. METHODS: A preclinical, prospective, single-blinded trial using a ventilated human cadaveric model assessed the successful puncture of implanted pulmonary nodules using various localization techniques with RAB. The different approaches included positioning the robotic catheter at predefined distances from the target nodule (<10 mm, 10-20 mm, 20-30 mm), bronchoscopist correction of divergence between the software virtual map and bronchoscopic view if observed, and impact of fluoroscopy and radial endobronchial ultrasound (rEBUS). The primary endpoint was a central target hit (defined as an inner 2/3 target puncture) verified by cone-beam computed tomography. RESULTS: Thirty-eight RAB procedures were performed to target 16 PPNs. Median nodule size was 16.2 mm. All targets were located in the outer 1/3 of the lung with a bronchus sign in 31.3%. Central target hit rates were improved when the robotic catheter tip was closer to the nodule (<10 mm 68%, 10-20 mm 66%, 20-30 mm 11%, p < 0.001). Multivariable analysis confirmed the strongest predictor of a central target hit was robotic catheter distance to nodule (OR 0.89 per increase in 1 mm, p < 0.001), independent of the presence of a bronchus sign, divergence or concentric rEBUS view. CONCLUSIONS: Utilizing a RAB platform, closer proximity of the robotic catheter to the target nodule results in an increase in peripheral nodule biopsy success.


Asunto(s)
Neoplasias Pulmonares , Procedimientos Quirúrgicos Robotizados , Broncoscopía/métodos , Endosonografía/métodos , Fluoroscopía , Humanos , Neoplasias Pulmonares/diagnóstico por imagen , Neoplasias Pulmonares/cirugía , Estudios Prospectivos , Procedimientos Quirúrgicos Robotizados/métodos
18.
Respirology ; 27(5): 357-365, 2022 05.
Artículo en Inglés | MEDLINE | ID: mdl-35212090

RESUMEN

BACKGROUND AND OBJECTIVE: Virtual bronchoscopic navigation (VBN) with fused fluoroscopy and vessel mapping provides a point of entry (POE) for puncturing airway wall to biopsy lesions. The study was designed to evaluate the safety and efficacy of this technology to diagnose peripheral pulmonary lesions. METHODS: It was a prospective, single-arm, multicentre study. Patients underwent lesions biopsy with the Archimedes® VBN System via a POE using one of the two techniques: (1) bronchoscopic transparenchymal nodule access (BTPNA) and (2) guided transbronchial needle aspiration (TBNA). Biopsy yield, sampling yield and diagnostic yield were mainly determined in lesions biopsy attempted. RESULTS: One hundred and thirty patients underwent anaesthesia and constituted the intention-to-treat population. One hundred and four patients with 114 lesions had biopsy attempted. Mean lesion size was 2.4 ± 1.13 cm. Sufficient tissue samples were obtained from 86 lesions with a biopsy yield of 75.4%. Nevertheless, sufficient samples for diagnosis based on histology ± cytology were obtained from 107 lesions with a sampling yield of 93.9%. Follow-up was conducted for more than 1 year, with a diagnostic yield of 75.4% and 72.8%, respectively, on high and low estimate with consideration of three lesions without follow-up. Two (1.9%) pneumothoraxes and one (1.0%) mild bleeding occurred. CONCLUSION: BTPNA and guided TBNA contribute to safe and effective sampling of peripheral pulmonary lesions. A relatively high biopsy yield was obtained independent of the presence or absence of a bronchus sign (BS), and high sampling yield and diagnostic yield were obtained independent of location, lesion size and presence or absence of a BS.


Asunto(s)
Broncoscopía , Neoplasias Pulmonares , Bronquios/diagnóstico por imagen , Bronquios/patología , Broncoscopía/efectos adversos , Fluoroscopía , Humanos , Pulmón/patología , Neoplasias Pulmonares/diagnóstico por imagen , Neoplasias Pulmonares/patología , Estudios Prospectivos
19.
Chest ; 161(3): 614-628, 2022 03.
Artículo en Inglés | MEDLINE | ID: mdl-34774528

RESUMEN

BACKGROUND: Bronchial thermoplasty is a device-based treatment for subjects ≥ 18 years of age with severe asthma poorly controlled with inhaled corticosteroids and long-acting beta-agonists. The Post-FDA Approval Clinical Trial Evaluating Bronchial Thermoplasty in Severe Persistent Asthma (PAS2) study collected data on patients with severe asthma undergoing this procedure. RESEARCH QUESTION: What are the 5-year efficacy and safety results in patients with severe asthma who have undergone bronchial thermoplasty? STUDY DESIGN AND METHODS: This was a prospective, open-label, observational, multicenter study conducted in the United States and Canada. Subjects 18 to 65 years of age who were taking inhaled corticosteroids ≥ 1,000 µg/d (beclomethasone or equivalent) and long-acting beta-agonists ≥ 80 µg/d (salmeterol or equivalent) were included. Severe exacerbations, hospitalization, ED visits, and medication usage were evaluated for the 12 months prior to and at years 1 through 5 posttreatment. Spirometry was evaluated at baseline and at years 1 through 5 posttreatment. RESULTS: A total of 284 subjects were enrolled at 27 centers; 227 subjects (80%) completed 5 years of follow-up. By year 5 posttreatment, the proportion of subjects with severe exacerbations, ED visits, and hospitalizations was 42.7%, 7.9%, and 4.8%, respectively, compared with 77.8%, 29.4%, and 16.1% in the 12 months prior to treatment. The proportion of subjects on maintenance oral corticosteroids decreased from 19.4% at baseline to 9.7% at 5 years. Analyses of subgroups based on baseline clinical and biomarker characteristics revealed a statistically significant clinical improvement among all subgroups. INTERPRETATION: Five years after treatment, subjects experienced decreases in severe exacerbations, hospitalizations, ED visits, and corticosteroid exposure. All subgroups demonstrated clinically significant improvement, suggesting that bronchial thermoplasty improves asthma control in different asthma phenotypes. CLINICAL TRIAL REGISTRATION: ClinicalTrials.gov; No.: NCT01350336; URL: www. CLINICALTRIALS: gov.


Asunto(s)
Asma , Termoplastia Bronquial , Corticoesteroides/uso terapéutico , Asma/tratamiento farmacológico , Asma/cirugía , Termoplastia Bronquial/métodos , Humanos , Estudios Prospectivos , Calidad de Vida
20.
Respiration ; 101(4): 394-400, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-34784603

RESUMEN

RATIONALE: Transbronchial lung cryobiopsy (TBLC) has emerged as a less invasive method to obtain a tissue diagnosis in patients with interstitial lung disease (ILD). The diagnostic yield of TBLC compared to surgical lung biopsy (SLB) remains uncertain. OBJECTIVES: The aim of this study was to determine the diagnostic accuracy of forceps transbronchial lung biopsy (TBLB) and TBLC compared to SLB when making the final diagnosis based on multidisciplinary discussion (MDD). METHODS: Patients enrolled in the study underwent sequential TBLB and TBLC followed immediately by SLB. De-identified cases, with blinding of the biopsy method, were reviewed by a blinded pathologist and then discussed at a multidisciplinary conference. MAIN RESULTS: Between August 2013 and October 2017, we enrolled 16 patients. The raw agreement between TBLC and SLB for the MDD final diagnosis was 68.75% with a Cohen's kappa of 0.6 (95% CI 0.39, 0.81). Raw agreement and Cohen's kappa of TBLB versus TBLC and TBLB versus SLB for the MDD final diagnosis were much lower (50%, 0.21 [95% CI 0, 0.42] and 18.75%, 0.08 [95% CI -0.03, 0.19], respectively). TBLC was associated with mild bleeding (grade 1 bleeding requiring suction to clear) in 56.2% of patients. CONCLUSIONS: In patients with ILD who have an uncertain type based on clinical and radiographic data and require tissue sampling to obtain a specific diagnosis, TBLC showed moderate correlation with SLB when making the diagnosis with MDD guidance. TBLB showed poor concordance with both TBLC and SLB MDD diagnoses.


Asunto(s)
Broncoscopía , Enfermedades Pulmonares Intersticiales , Biopsia/métodos , Broncoscopía/métodos , Humanos , Pulmón/patología , Enfermedades Pulmonares Intersticiales/diagnóstico , Enfermedades Pulmonares Intersticiales/patología , Instrumentos Quirúrgicos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...