Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 40
Filtrar
1.
J Arrhythm ; 40(3): 501-507, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38939768

RESUMEN

Background: Patients who have recurrent atrial fibrillation (AF) following redo catheter ablation may eventually be managed with a pace-and-ablate approach, involving pacemaker implant followed by atrioventricular nodal ablation (AVNA). We sought to determine which factors would predict subsequent AVNA in patients undergoing redo AF ablation. Methods: We analyzed patients undergoing redo AF ablations between 2013 and 2019 at our institution. Follow-up was censored on December 31, 2021. Patients with no available follow-up data were excluded. Time-to-event analysis with Cox proportional hazard regression was used to compare those who underwent AVNA to those who did not. Results: A total of 467 patients were included, of whom 39 (8.4%) underwent AVNA. After multivariable adjustment, female sex (aHR 4.68 [95% CI 2.30-9.50]; p < 0.001), ischemic heart disease (aHR 2.99 [95% CI 1.25-7.16]; p = 0.014), presence of a preexisting pacemaker (aHR 3.25 [95% CI 1.10-9.60]; p = 0.033), and persistent AF (aHR 2.22 [95% CI 1.07-4.59]; p = 0.032) were associated with increased risk of subsequent AVNA requirement. Conclusion: Female sex, ischemic heart disease, and persistent AF may be useful clinical predictors of the requirement for subsequent AVNA and may be considered as part of shared clinical decision making.

2.
Heart Rhythm ; 2024 May 17.
Artículo en Inglés | MEDLINE | ID: mdl-38763378

RESUMEN

BACKGROUND: With the exponential growth of catheter ablation for atrial fibrillation (AF), there is increasing interest in associated health care costs. Pulsed field ablation (PFA) using a single-shot pentaspline multielectrode catheter has been shown to be safe and effective for AF ablation, but its cost efficiency compared to conventional thermal ablation modalities (cryoballoon [CB] or radiofrequency [RF]) has not been evaluated. OBJECTIVE: The purpose of this study was to compare cost, efficiency, effectiveness, and safety between PFA, CB, and RF for AF ablation. METHODS: We studied 707 consecutive patients (PFA: 208 [46.0%]; CB: 325 [29.4%]; RF: 174 [24.6%]) undergoing first-time AF ablation. Individual procedural costs were calculated, including equipment, laboratory use, and hospital stay, and compared between ablation modalities, as were effectiveness and safety. RESULTS: Skin-to-skin times and catheter laboratory times were significantly shorter with PFA (68 and 102 minutes, respectively) than with CB (91 and 122 minutes) and RF (89 and 123 minutes) (P < .001). General anesthesia use differed across modalities (PFA 100%; CB 10.2%; RF 61.5%) (P < .001). Major complications occurred in 1% of cases, with no significant differences between modalities. Shorter procedural times resulted in lower staffing and laboratory costs with PFA, but these savings were offset by substantially higher equipment costs, resulting in higher overall median costs with PFA (£10,010) than with CB (£8106) and RF (£8949) (P < .001). CONCLUSION: In this contemporary real-world study of the 3 major AF ablation modalities used concurrently, PFA had shorter skin-to-skin and catheter laboratory times than did CB and RF, with similarly low rates of complications. However, PFA procedures were considerably more expensive, largely because of higher equipment cost.

3.
Heart Rhythm O2 ; 5(4): 224-233, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38690145

RESUMEN

Background: Defining postinfarct ventricular arrhythmic substrate is challenging with voltage mapping alone, though it may be improved in combination with an activation map. Omnipolar technology on the EnSite X system displays activation as vectors that can be superimposed onto a voltage map. Objective: The study sought to optimize voltage map settings during ventricular tachycardia (VT) ablation, adjusting them dynamically using omnipolar vectors. Methods: Consecutive patients undergoing substrate mapping were retrospectively studied. We categorized omnipolar vectors as uniform when pointing in one direction, or in disarray when pointing in multiple directions. We superimposed vectors onto voltage maps colored purple in tissue >1.5 mV, and the voltage settings were adjusted so that uniform vectors appeared within purple voltages, a process termed dynamic voltage mapping (DVM). Vectors in disarray appeared within red-blue lower voltages. Results: A total of 17 substrate maps were studied in 14 patients (mean age 63 ± 13 years; mean left ventricular ejection fraction 35 ± 6%, median 4 [interquartile range 2-8.5] recent VT episodes). The DVM mean voltage threshold that differentiated tissue supporting uniform vectors from disarray was 0.27 mV, ranging between patients from 0.18 to 0.50 mV, with good interobserver agreement (median difference: 0.00 mV). We found that VT isthmus components, as well as sites of latest activation, isochronal crowding, and excellent pace maps colocated with tissue along the DVM border zone surrounding areas of disarray. Conclusion: DVM, guided by areas of omnipolar vector disarray, allows for individualized postinfarct ventricular substrate characterization. Tissue bordering areas of disarray may harbor greater arrhythmogenic potential.

4.
Artículo en Inglés | MEDLINE | ID: mdl-38261098

RESUMEN

BACKGROUND: Pulmonary vein isolation (PVI) is the cornerstone of atrial fibrillation (AF) ablation. Despite promising success rates, redo ablation is sometimes required. At redo, PVs may be found to be isolated (silent) or reconnected. We studied patients with silent vs reconnected PVs at redo and analysed associations with adverse outcomes. METHODS: Patients undergoing redo AF ablations between 2013 and 2019 at our institution were included and stratified into silent PVs or reconnected PVs. The primary outcome was a composite of further redo ablation, non-AF ablation, atrioventricular nodal ablation, and death. Secondary outcomes included arrhythmia recurrence. RESULTS: A total of 467 patients were included with mean 4.6 ± 1.7 years follow-up, of whom 48 (10.3%) had silent PVs. The silent PV group had had more often undergone >1 prior ablation (45.8% vs 9.8%; p<0.001), had more persistent AF (62.5% vs 41.1%; p=0.005) and had more non-PV ablation performed both at prior ablation procedures and at the analysed redo ablation. The primary outcome occurred more frequently in those with silent PVs (25% vs 13.8%; p=0.053). Arrhythmia recurrence was also more common in the silent PV group (66.7% vs 50.6%; p=0.047). After multivariable adjustment, female sex (aHR 2.35 [95% CI 2.35-3.96]; p=0.001) and ischaemic heart disease (aHR 3.21 [95% CI 1.56-6.62]; p=0.002) were independently associated with the primary outcome, and left atrial enlargement (aHR 1.58 [95% CI 1.20-2.08]; p=0.001) and >1 prior ablation (aHR 1.88 [95% CI 1.30-2.72]; p<0.001) were independently associated with arrhythmia recurrence. Whilst a finding of silent PVs was not itself significant after multivariable adjustment, this provides an easily assessable parameter at clinically indicated redo ablation which informs the clinician of the likelihood of a worse future prognosis. CONCLUSIONS: Patients with silent PVs at redo AF ablation have worse clinical outcomes.

5.
J Cardiovasc Electrophysiol ; 34(3): 664-672, 2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-36478627

RESUMEN

BACKGROUND: Ventricular scar is traditionally highlighted on a bipolar voltage (BiVolt) map in areas of myocardium <0.50 mV. We describe an alternative approach using Ripple Mapping (RM) superimposed onto a BiVolt map to differentiate postinfarct scar from conducting borderzone (BZ) during ventricular tachycardia (VT) ablation. METHODS: Fifteen consecutive patients (left ventricular ejection fraction 30 ± 7%) underwent endocardial left ventricle pentaray mapping (median 5148 points) and ablation targeting areas of late Ripple activation. BiVolt maps were studied offline at initial voltage of 0.50-0.50 mV to binarize the color display (red and purple). RMs were superimposed, and the BiVolt limits were sequentially reduced until only areas devoid of Ripple bars appeared red, defined as RM-scar. The surrounding area supporting conducting Ripple wavefronts in tissue <0.50 mV defined the RM-BZ. RESULTS: RM-scar was significantly smaller than the traditional 0.50 mV cutoff (median 4% vs. 12% shell area, p < .001). 65 ± 16% of tissue <0.50 mV supported Ripple activation within the RM-BZ. The mean BiVolt threshold that differentiated RM-scar from BZ tissue was 0.22 ± 0.07 mV, though this ranged widely (from 0.12 to 0.35 mV). In this study, septal infarcts (7/15) were associated with more rapid VTs (282 vs. 347 ms, p = .001), and had a greater proportion of RM-BZ to RM-scar (median ratio 3.2 vs. 1.2, p = .013) with faster RM-BZ conduction speed (0.72 vs. 0.34 m/s, p = .001). Conversely, scars that supported hemodynamically stable sustained VT (6/15) were slower (367 ± 38 ms), had a smaller proportion of RM-BZ to RM-scar (median ratio 1.2 vs. 3.2, p = .059), and slower RM-BZ conduction speed (0.36 vs. 0.63 m/s, p = .036). RM guided ablation collocated within 66 ± 20% of RM-BZ, most concentrated around the RM-scar perimeter, with significant VT reduction (median 4.0 episodes preablation vs. 0 post, p < .001) at 11 ± 6 months follow-up. CONCLUSION: Postinfarct scars appear significantly smaller than traditional 0.50 mV cut-offs suggest, with voltage thresholds unique to each patient.


Asunto(s)
Ablación por Catéter , Taquicardia Ventricular , Humanos , Cicatriz , Volumen Sistólico , Técnicas Electrofisiológicas Cardíacas , Función Ventricular Izquierda
6.
J Interv Card Electrophysiol ; 66(3): 693-700, 2023 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-36214805

RESUMEN

BACKGROUND: Ultrasound (US) is being increasingly used to guide vascular access for electrophysiology (EP) procedures in many centres. Nonetheless, the incidence and predictors of vascular complications in the US era are limited. In this study, we describe our experience of vascular access-related complications associated with EP procedures which were performed with the routine use of US-guided vascular access. METHODS: A total of 10,158 consecutive EP procedures in 8361 patients performed from April 2014 (when our centre moved to a policy of routine US-guided vascular access for EP procedures) to March 2022 were included. The outcome of interest was any vascular access-related complication that occurred within 7 days of the procedure; these were classified as severe if surgical intervention and/or blood transfusion was required, major if non-surgical intervention or delayed hospital discharge was required, or minor if it did not fulfil the criteria for severe or major. RESULTS: During the study period, 2 (0.02%) severe vascular complications occurred, including 1 pseudo-aneurysm requiring surgery and 1 retroperitoneal haemorrhage requiring blood transfusion. Nine (0.09%) major complications occurred, including 6 hematomas managed by compression devices, 1 type B aortic dissection, 1 AV fistula managed conservatively and 1 haematoma managed conservatively but delayed hospital discharge. Eighteen (0.18%) minor haematomas were seen that did not require any intervention or delayed hospital discharge. On multivariable analysis, female sex [OR (95% CI): 2.5 (1.2, 5.4)] and use of an arterial access [OR (95% CI): 19.3 (7.1, 52.3)] were seen to be independent predictors of the 29 vascular complications. CONCLUSION: With the use of US-guided vascular access in EP procedures, major vascular complications are exceedingly rare, particularly those needing surgical intervention. Our results provide additional evidence for scientific guidelines to support US use.


Asunto(s)
Hematoma , Hemorragia , Humanos , Femenino , Incidencia , Factores de Riesgo , Hematoma/diagnóstico por imagen , Hematoma/epidemiología , Hematoma/etiología , Electrofisiología , Resultado del Tratamiento , Estudios Retrospectivos
7.
Open Heart ; 9(1)2022 06.
Artículo en Inglés | MEDLINE | ID: mdl-35697474

RESUMEN

OBJECTIVE: Atrial fibrillation (AF) ablation services were significantly affected by the COVID-19 pandemic. We aimed to evaluate a symptom-based clinician prioritisation scheme for waiting list management compared with patient-completed quality of life (QoL) scores. We also sought to understand factors influencing QoL, particularly the impact of COVID-19, on patients awaiting AF ablation, via a bespoke questionnaire. METHODS: Patients awaiting AF ablation were sent two QoL questionnaires (Atrial Fibrillation Effect on QualiTy of Life (AFEQT) and EuroQol 5D (EQ5D-5L)) and the bespoke questionnaire. At a separate time point, patients were categorised as C1-urgent, C2-priority or C3-routine by their cardiologist based on review of clinic letters. RESULTS: There were 118 patients included with priority categorisation available for 86 patients. Median AFEQT scores were lower in C2 (30.4; 17.2-51.9) vs C3 patients (56.5; 32.1-74.1; p<0.01). Unplanned admission occurred in 3 patients in C3 with AFEQT scores of <40. Although 65 patients had AF symptoms during the pandemic, 43.1% did not seek help where they ordinarily would have. An exercise frequency of ≥3-4 times a week was associated with higher AFEQT (56.5; 41.2-74.1; p<0.001) and EQ5D (0.84; 0.74-0.88; p<0.0001) scores. CONCLUSION: The QoL of patients awaiting AF ablation is impaired and AFEQT helps to identify patients at risk of admission, over and above physician assessment. COVID-19 influenced patients seeking medical attention with symptomatic AF when they normally would. Regular exercise is associated with better QoL in patients awaiting AF ablation.


Asunto(s)
Fibrilación Atrial , COVID-19 , Ablación por Catéter , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/epidemiología , Fibrilación Atrial/cirugía , Ablación por Catéter/efectos adversos , Humanos , Pandemias , Calidad de Vida
8.
ESC Heart Fail ; 9(3): 1864-1874, 2022 06.
Artículo en Inglés | MEDLINE | ID: mdl-35322594

RESUMEN

AIMS: Patients awaiting orthotopic heart transplantation (OHT) can be bridged utilizing a left ventricular assist device (LVAD) that reduces left ventricular filling pressures, decreases pulmonary artery wedge pressure, and maintains adequate cardiac output. This study set out to examine the poorly investigated area of if and how pre-treatment with LVAD impacts right ventricular (RV) function following OHT. METHODS AND RESULTS: We prospectively evaluated 59 (LVAD n = 20) consecutive OHT patients. Transthoracic echocardiography (TTE) was performed in conjunction with right heart catheterization (RHC) at 1, 6, and 12 months after OHT. RV function TTE-parameters included tricuspid annular plane systolic excursion (TAPSE), systolic tissue velocity (S'), fractional area change, two-dimensional RV global longitudinal strain and longitudinal strain from the RV lateral wall (RVfree). At 1 month after OHT, the LVAD group had significantly better longitudinal RV function than the non-LVAD group: TAPSE (15 ± 3 mm vs. 12 ± 2 mm, P < 0.001), RV global longitudinal strain (-19.8 ± 2.1% vs. -14.3 ± 2.8%, P < 0.001), and RVfree (-19.8 ± 2.3% vs. -14.1 ± 2.9%, P < 0.001). At this time point, pulmonary vascular resistance (PVR) was also lower [1.2 ± 0.4 Wood Units (WU) vs. 1.6 ± 0.6 WU, P < 0.05] in the LVAD group compared with the non-LVAD group. At 6 and 12 months, no difference was detected in any of the TTE and RHC measured parameters between the two groups. Between 1 and 12 months, all parameters of RV function improved significantly in the non-LVAD group but remained unaltered in the LVAD group. CONCLUSIONS: Our results indicate that pre-treatment with LVAD decreases PVR and is associated with significantly better RV function early following OHT. During the first year following transplantation, RV function progressively improved in the non-LVAD group such that at 6 and 12 months, no difference in RV function was detected between the groups.


Asunto(s)
Trasplante de Corazón , Corazón Auxiliar , Ecocardiografía/métodos , Ventrículos Cardíacos/diagnóstico por imagen , Humanos , Función Ventricular Derecha
9.
BMC Cardiovasc Disord ; 21(1): 219, 2021 04 30.
Artículo en Inglés | MEDLINE | ID: mdl-33931021

RESUMEN

BACKGROUND: In adult patients with pulmonary arterial hypertension (PAH), right ventricular (RV) failure may worsen rapidly, resulting in a poor prognosis. In this population, non-invasive assessment of RV function is challenging. RV stroke work index (RVSWI) measured by right heart catheterization (RHC) represents a promising index for RV function. The aim of the present study was to comprehensively evaluate non-invasive measures to calculate RVSWI derived by echocardiography (RVSWIECHO) using RHC (RVSWIRHC) as a reference in adult PAH patients. METHODS: Retrospectively, 54 consecutive treatment naïve patients with PAH (65 ± 13 years, 36 women) were analyzed. Echocardiography and RHC were performed within a median of 1 day [IQR 0-1 days]. RVSWIRHC was calculated as: (mean pulmonary arterial pressure (mPAP)-mean right atrial pressure (mRAP)) x stroke volume index (SVI)RHC. Four methods for RVSWIECHO were evaluated: RVSWIECHO-1 = Tricuspid regurgitant maximum pressure gradient (TRmaxPG) x SVIECHO, RVSWIECHO-2 = (TRmaxPG-mRAPECHO) x SVIECHO, RVSWIECHO-3 = TR mean gradient (TRmeanPG) x SVIECHO and RVSWIECHO-4 = (TRmeanPG-mRAPECHO) x SVIECHO. Estimation of mRAPECHO was derived from inferior vena cava diameter. RESULTS: RVSWIRHC was 1132 ± 352 mmHg*mL*m-2. In comparison with RVSWIRHC in absolute values, RVSWIECHO-1 and RVSWIECHO-2 was significantly higher (p < 0.001), whereas RVSWIECHO-4 was lower (p < 0.001). No difference was shown for RVSWIECHO-3 (p = 0.304). The strongest correlation, with RVSWIRHC, was demonstrated for RVSWIECHO-2 (r = 0.78, p < 0.001) and RVSWIECHO-1 ( r = 0.75, p < 0.001). RVSWIECHO-3 and RVSWIECHO-4 had moderate correlation (r = 0.66 and r = 0.69, p < 0.001 for all). A good agreement (ICC) was demonstrated for RVSWIECHO-3 (ICC = 0.80, 95% CI 0.64-0.88, p < 0.001), a moderate for RVSWIECHO-4 (ICC = 0.73, 95% CI 0.27-0.87, p < 0.001) and RVSWIECHO-2 (ICC = 0.55, 95% CI - 0.21-0.83, p < 0.001). A poor ICC was demonstrated for RVSWIECHO-1 (ICC = 0.45, 95% CI - 0.18-0.77, p < 0.001). Agreement of absolute values for RVSWIECHO-1 was - 772 ± 385 (- 50 ± 20%) mmHg*mL*m-2, RVSWIECHO-2 - 600 ± 339 (-41 ± 20%) mmHg*mL*m-2, RVSWIECHO-3 42 ± 286 (5 ± 25%) mmHg*mL*m-2 and for RVSWIECHO-4 214 ± 273 (23 ± 27%) mmHg*mL*m-2. CONCLUSION: The correlation with RVSWIRHC was moderate to strong for all echocardiographic measures, whereas only RVSWIECHO-3 displayed high concordance of absolute values. The results, however, suggest that RVSWIECHO-1 or RVSWIECHO-3 could be the preferable echocardiographic methods. Prospective studies are warranted to evaluate the clinical utility of such measures in relation to treatment response, risk stratification and prognosis in patients with PAH.


Asunto(s)
Ecocardiografía , Hemodinámica , Hipertensión Arterial Pulmonar/complicaciones , Disfunción Ventricular Derecha/diagnóstico por imagen , Función Ventricular Derecha , Anciano , Cateterismo Cardíaco , Femenino , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Hipertensión Arterial Pulmonar/diagnóstico , Hipertensión Arterial Pulmonar/fisiopatología , Reproducibilidad de los Resultados , Estudios Retrospectivos , Disfunción Ventricular Derecha/etiología , Disfunción Ventricular Derecha/fisiopatología
10.
Clin Physiol Funct Imaging ; 41(4): 355-365, 2021 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-33830620

RESUMEN

AIMS: Detecting changes in ventricular function after orthotopic heart transplantation (OHT) using transthoracic echocardiography (TTE) is important but interpretation of findings is complicated by lack of data on early graft adaptation. We sought to evaluate echocardiographic measures of ventricular size and function the first year following OHT including speckle tracking derived strain. We also aimed to compare echocardiographic findings to haemodynamic parameters obtained by right heart catheterization (RHC). METHODS AND RESULTS: Fifty OHT patients were examined prospectively with TTE and RHC at 1, 6, and 12 months after OHT. Left ventricle (LV) was assessed with fractional shortening, ejection fraction and systolic tissue velocities. Right ventricular (RV) evaluation included tricuspid annular plane systolic excursion (TAPSE), systolic tissue velocity (S´) and fractional area change (FAC). LV global longitudinal and circumferential strain and RV global longitudinal strain (GLS) and RV lateral wall strain (RVfree) were analysed. No relevant changes occurred in LV echocardiographic parameters, whereas all measures of RV function improved significantly during follow-up. There was an increase in TAPSE (12.4 ± 3.3 mm to 14.4 ± 4.3 mm, p < .01), FAC (36% ± 8% to 41% ± 8%, p < .01), RV GLS (-15.8% ± 4% to -17.8% ± 3.6%, p < .01), and RVfree (-15.5% ± 3.7% to -18.6% ± 3.6%, p < .001). Between 1 and 12 months, pulmonary pressures decreased, whereas pulmonary vascular resistance did not. CONCLUSION: Stable OHT recipients reached steady state regarding LV function 1 month after transplantation. In contrast, RV function displayed gradual improvement the first year following OHT, indicating delayed RV adaptation as compared to the LV. Improved RV function parameters were independent of invasively measured pulmonary pressures.


Asunto(s)
Trasplante de Corazón , Disfunción Ventricular Derecha , Ecocardiografía , Trasplante de Corazón/efectos adversos , Ventrículos Cardíacos/diagnóstico por imagen , Humanos , Sístole , Función Ventricular Derecha
11.
J Arrhythm ; 36(4): 685-691, 2020 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-32782640

RESUMEN

BACKGROUND: Catheter ablation for atrial fibrillation (AF) traditionally requires the use of circular mapping catheter (CMC) for pulmonary vein isolation (PVI). This study aimed to assess the feasibility and effectiveness of a CMC-free approach for AF ablation performed by a contiguous optimized (CLOSE) ablation protocol. METHODS: A CLOSE-guided and CMC-free PVI protocol with a single transseptal puncture was attempted in 67 patients with AF. Left atrial (LA) CARTO voltage mapping was performed with the ablation catheter pre- and postablation to demonstrate entry block into the pulmonary veins, and pacing maneuvers were used to confirm exit block. RESULTS: The CMC-free approach was successful in achieving PVI in 66 (98.5%) cases, with procedure time of 148 ± 32 minutes, ablation time of 27.5 ± 5.7 minutes, and fluoroscopy time of 7.8 ± 1.0 minutes. First-pass PVI was seen in 58(86.5%) patients, and pacing maneuvers successfully identified the residual gap in eight of the other nine cases. No complication was observed. At 12 months follow-up, 60 (89.6%) patients remained free from AF. The CMC-free approach resulted in a cost saving of £47,190. CONCLUSION: A CMC-free CLOSE-guided PVI approach is feasible, safe, and cost-saving, and is associated with excellent clinical outcomes at 1 year.

12.
BMC Cardiovasc Disord ; 20(1): 259, 2020 06 01.
Artículo en Inglés | MEDLINE | ID: mdl-32487063

RESUMEN

BACKGROUND: Right ventricular (RV) function is a major determinant of outcome in patients with pulmonary hypertension. Cardiac magnetic resonance (CMR) is gold standard to assess RV ejection fraction (RVEFCMR), however this is a crude measure. New CMR measures of RV function beyond RVEFCMR have emerged, such as RV lateral atrio-ventricular plane displacement (AVPDlat), maximum emptying velocity (S'CMR), RV fractional area change (FACCMR) and feature tracking of the RV free wall (FWSCMR). However, it is not fully elucidated if these CMR measures are in parity with the equivalent echocardiography-derived measurements: tricuspid annular plane systolic excursion (TAPSE), S'-wave velocity (S'echo), RV fractional area change (FACecho) and RV free wall strain (FWSecho). The aim of this study was to compare regional RV function parameters derived from CMR to their echocardiographic equivalents in patients with pulmonary hypertension and to RVEFCMR. METHODS: Fifty-five patients (37 women, 62 ± 15 years) evaluated for pulmonary hypertension underwent CMR and echocardiography. AVPDlat, S'CMR, FACCMR and FWSCMR from cine 4-chamber views were compared to corresponding echocardiographic measures and to RVEFCMR delineated in cine short-axis stack. RESULTS: A strong correlation was demonstrated for FAC whereas the remaining measurements showed moderate correlation. The absolute bias for S' was 2.4 ± 3.0 cm/s (relative bias 24.1 ± 28.3%), TAPSE/AVPDlat 5.5 ± 4.6 mm (33.2 ± 25.2%), FWS 4.4 ± 5.8% (20.2 ± 37.5%) and for FAC 5.1 ± 8.4% (18.5 ± 32.5%). In correlation to RVEFCMR, FACCMR and FWSecho correlated strongly, FACecho, AVPDlat, FWSCMR and TAPSE moderately, whereas S' had only a weak correlation. CONCLUSION: This study has demonstrated a moderate to strong correlation of regional CMR measurements to corresponding echocardiographic measures. However, biases and to some extent wide limits of agreement, exist between the modalities. Consequently, the equivalent measures are not interchangeable at least in patients with pulmonary hypertension. The echocardiographic parameter that showed best correlation with RVEFCMR was FWSecho. At present, FACecho and FWSecho as well as RVEFCMR are the preferred methods to assess and follow up RV function in patients with pulmonary hypertension. Future investigations of the CMR right ventricular measures, beyond RVEF, are warranted.


Asunto(s)
Ecocardiografía , Hipertensión Pulmonar/diagnóstico por imagen , Imagen por Resonancia Cinemagnética , Volumen Sistólico , Disfunción Ventricular Derecha/diagnóstico por imagen , Función Ventricular Derecha , Anciano , Femenino , Humanos , Hipertensión Pulmonar/complicaciones , Hipertensión Pulmonar/fisiopatología , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Estudios Prospectivos , Disfunción Ventricular Derecha/etiología , Disfunción Ventricular Derecha/fisiopatología
13.
Pacing Clin Electrophysiol ; 42(11): 1448-1455, 2019 11.
Artículo en Inglés | MEDLINE | ID: mdl-31538362

RESUMEN

BACKGROUND: Atrial fibrillation (AF) ablation is a complex procedure, generally requiring at least one overnight hospital stay. We investigated the safety and feasibility of early mobilization and same-day discharge following streamlined peri-ablation management for AF. METHODS: From 2014, we offered same-day discharge to selected patients who underwent uncomplicated AF ablation on the morning lists, with ultrasound-guided femoral access, uninterrupted warfarin or minimal interruption in novel oral anticoagulants, and reversal of intraprocedural heparin with protamine. Patients were discharged 6-8 h postprocedure and offered access to a dedicated nurse helpline. RESULTS: Of 1599 AF ablation cases performed from April 2014 to March 2017, 811 (50.7%) were performed on the morning lists and 169/811 (20.8%) were discharged on the same day. Excluding 26 research cases, 1/143 (0.7%) had transient right phrenic nerve palsy and five (3.5%) cases experienced minor problems that did not preclude same-day discharge; three (2.1%) needed rehospitalization postdischarge: one for pericarditic chest pain and two for nausea/vomiting. Compared to 642 overnight cases, day-case procedures were shorter, more likely to be redos, to be performed under sedation rather than general anesthesia, and less likely to involve linear lesions and electrical cardioversion. There were no significant differences in patient age, gender, body mass index, CHA2 DS2 -VASc, in preprocedural anticoagulation regimen (warfarin vs novel anticoagulants vs no anticoagulation) and in choice of ablation method (cryoballoon vs radiofrequency). CONCLUSIONS: Selective same-day discharge after AF ablation is safe and feasible using a streamlined peri-procedural care protocol. Wider adoption can potentially reduce health-care costs while improving patient experience.


Asunto(s)
Procedimientos Quirúrgicos Ambulatorios , Fibrilación Atrial/cirugía , Ablación por Catéter , Alta del Paciente , Selección de Paciente , Anciano , Ablación por Catéter/efectos adversos , Ambulación Precoz , Estudios de Factibilidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/etiología , Estudios Retrospectivos , Factores de Tiempo
14.
Europace ; 21(5): 738-745, 2019 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-30753411

RESUMEN

AIMS: Video-assisted thoracoscopic surgery (VATS) ablation has been advocated as a treatment option for non-paroxysmal atrial fibrillation (AF) in recent guidelines. Real-life data on its safety and efficacy during a centre's early experience are sparse. METHODS AND RESULTS: Thirty patients (28 persistent/longstanding persistent AF) underwent standalone VATS ablation for AF by an experienced thoracoscopic surgeon, with the first 20 cases proctored by external surgeons. Procedural and follow-up outcomes were collected prospectively, and compared with 90 propensity-matched patients undergoing contemporaneous catheter ablation (CA). Six (20.0%) patients undergoing VATS ablation experienced ≥1 major complication (death n = 1, stroke n = 2, conversion to sternotomy n = 3, and phrenic nerve injury n = 2). This was significantly higher than the 1.1% major complication rate (tamponade requiring drainage n = 1) seen with CA (P < 0.001). Twelve-month single procedure arrhythmia-free survival rates without antiarrhythmic drugs were 56% in the VATS and 57% in the CA cohorts (P = 0.22), and 78% and 80%, respectively given an additional CA and antiarrhythmic drugs (P = 0.32). CONCLUSION: During a centre's early experience, VATS ablation may have similar success rates to those from an established CA service, but carry a greater risk of major complications. Those embarking on a programme of VATS AF ablation should be aware that complication and success rates may differ from those reported by selected high-volume centres.


Asunto(s)
Fibrilación Atrial/cirugía , Taponamiento Cardíaco , Ablación por Catéter , Conversión a Cirugía Abierta/estadística & datos numéricos , Complicaciones Intraoperatorias , Cirugía Torácica Asistida por Video , Fibrilación Atrial/diagnóstico , Taponamiento Cardíaco/epidemiología , Taponamiento Cardíaco/etiología , Taponamiento Cardíaco/cirugía , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Estudios de Cohortes , Investigación sobre la Eficacia Comparativa , Femenino , Humanos , Complicaciones Intraoperatorias/epidemiología , Complicaciones Intraoperatorias/etiología , Masculino , Persona de Mediana Edad , Evaluación de Procesos y Resultados en Atención de Salud , Nervio Frénico/lesiones , Cirugía Torácica Asistida por Video/efectos adversos , Cirugía Torácica Asistida por Video/métodos , Reino Unido
15.
Clin Physiol Funct Imaging ; 39(4): 246-254, 2019 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-30770630

RESUMEN

AIMS: Assessment following heart transplantation (HTx) is routinely performed using transthoracic echocardiography. Differences in long-term mortality following HTx related to donor-recipient matching have been reported, but effects of gender on cardiac size and function are not well studied. The aims of this study were to evaluate differences in echocardiographic characteristics of HTx recipients defined by gender. METHODS AND RESULTS: The study prospectively enrolled 123 (n = 34 female) HTx recipients of which 23 recipients was donor-recipient gender mismatched. Patients were examined with 2-dimensional echocardiography using Philips iE33 ultrasound system. Data were analysed across strata based on recipient gender and gender mismatch. Male recipients had larger left ventricular (LV) mass, thicker septal wall (P<0·001) and larger absolute LV volumes (P<0·001). Mean LV ejection fraction (EF) was higher in females (P<0·05), but no differences in conventional parameters of right ventricular (RV) function were found. Ventricular strain was higher in females than in males: LV global longitudinal strain (P<0·01), RV global longitudinal strain (P<0·05) and RV lateral free wall (P<0·05). The male group receiving a female donor heart had comparable EF and strain parameters to the female group receiving a gender-matched heart. CONCLUSION: We found that female recipient gender was associated with smaller chamber size, higher LV EF and better LV and RV longitudinal strain. Gender-mismatched male recipients appeared to exhibit function parameters similar to gender-matched female recipients. Our results indicate that the gender aspect, analogous to current reference guidelines in general population, should be taken into consideration when examining patients post-HTx.


Asunto(s)
Ecocardiografía , Trasplante de Corazón , Corazón/diagnóstico por imagen , Complicaciones Posoperatorias/diagnóstico por imagen , Adulto , Anciano , Femenino , Supervivencia de Injerto , Corazón/fisiopatología , Trasplante de Corazón/efectos adversos , Trasplante de Corazón/mortalidad , Humanos , Masculino , Persona de Mediana Edad , Contracción Miocárdica , Complicaciones Posoperatorias/mortalidad , Complicaciones Posoperatorias/fisiopatología , Valor Predictivo de las Pruebas , Estudios Prospectivos , Factores Sexuales , Volumen Sistólico , Factores de Tiempo , Resultado del Tratamiento , Función Ventricular Izquierda , Función Ventricular Derecha , Remodelación Ventricular
16.
J Cardiovasc Electrophysiol ; 30(1): 118-127, 2019 01.
Artículo en Inglés | MEDLINE | ID: mdl-30203441

RESUMEN

BACKGROUND: A large number of SCN5A variants have been reported to underlie Brugada syndrome (BrS). However, the evidence supporting individual variants is highly heterogeneous. OBJECTIVE: We systematically re-evaluated all SCN5A variants reported in BrS using the 2015 American college of medical genetics and genomics and the association for molecular pathology (ACMG-AMP) guidelines. METHODS: A PubMed/Embase search was performed to identify all reported SCN5A variants in BrS. Standardized bioinformatic re-analysis (SIFT, PolyPhen, Mutation Taster, Mutation assessor, FATHMM, GERP, PhyloP, and SiPhy) and re-evaluation of frequency in the gnomAD database were performed. Fourteen ACMG-AMP rules were deemed applicable for SCN5A variant analysis. RESULTS: Four hundred and eighty unique SCN5A variants were identified, the majority of which 425 (88%) were coding variants. One hundred and fifty-six of 425 (37%) variants were classified as pathogenic/likely pathogenic. Two hundred and fifty-eight (60%) were classified as variants of uncertain significance, while a further 11 (3%) were classified as benign/likely benign. When considering the subset of variants that were considered "null" variants separately, 95% fulfilled criteria for pathogenicity/likely pathogenicity. In contrast, only 17% of missense variants fulfilled criteria for pathogenicity/likely pathogenicity. Importantly, however, only 25% of missense variants had available functional data, which was a major score driver for pathogenic classification. CONCLUSION: Based on contemporary ACMG-AMP guidelines, only a minority of SCN5A variants implicated in BrS fulfill the criteria for pathogenicity or likely pathogenicity.


Asunto(s)
Síndrome de Brugada/genética , Variación Genética , Canal de Sodio Activado por Voltaje NAV1.5/genética , Potenciales de Acción , Síndrome de Brugada/diagnóstico , Síndrome de Brugada/metabolismo , Síndrome de Brugada/fisiopatología , Predisposición Genética a la Enfermedad , Frecuencia Cardíaca , Humanos , Canal de Sodio Activado por Voltaje NAV1.5/metabolismo , Fenotipo , Factores de Riesgo
17.
J Cardiovasc Electrophysiol ; 29(11): 1493-1499, 2018 11.
Artículo en Inglés | MEDLINE | ID: mdl-30230085

RESUMEN

INTRODUCTION: Demonstration of exit block after pulmonary vein isolation (PVI) is the cornerstone of ablation for atrial fibrillation (AF). It requires the demonstration of local pulmonary vein (PV) capture and absence of conduction to the atrium but is often challenging due to the inability to see local paced PV-evoked potentials. We retrospectively examined the ability of adenosine to augment this technique during CARTO-based radiofrequency ablation procedures. METHODS: Retrospective analysis of evoked PV potentials during adenosine administration while testing for PV exit block at a single UK center. RESULTS: One hundred and twenty-nine PVs in 33 patients were isolated using radiofrequency energy to demonstrate entry block. Of those, the pacing of 24 veins under baseline conditions did not clearly demonstrate local PV-evoked potentials sufficient to be sure that the local vein was truly captured and dissociated from the atrium. Adenosine was administered in 19 of these, with 10 of 19 (52.6%) veins then demonstrating clear local PV-evoked potentials transiently during adenosine administration, sufficient to allow assessment of definite exit block. CONCLUSION: Adenosine administered during PV pacing allows transient visualization of local PV-evoked potentials after PVI facilitating the clearer demonstration of PV exit block in over 50% veins.


Asunto(s)
Adenosina/administración & dosificación , Antiarrítmicos/administración & dosificación , Fibrilación Atrial/tratamiento farmacológico , Fibrilación Atrial/cirugía , Ablación por Catéter/métodos , Venas Pulmonares/efectos de los fármacos , Venas Pulmonares/cirugía , Fibrilación Atrial/diagnóstico , Humanos , Estudios Retrospectivos
18.
J Interv Card Electrophysiol ; 53(1): 47-51, 2018 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-29948586

RESUMEN

PURPOSE: The aim of our study is to determine if there is a natural progression of QRSd in ICD-only patients. METHODS AND RESULTS: Retrospective study over a 7-year period of 86 consecutive patients who underwent ICD-only implantation in 2008 at the Liverpool Heart and Chest Hospital, UK. The mean age at ICD implantation was 62.3 (± 11.5) years, range 24-82 years. Mean length of follow-up ECGs available was 5.0 (± 1.6) years, total of 431 patient-years. We observed a progressive prolongation of QRSd over the 7-year study period. The linear mixed model found a statistically significant (p < 0.001) increase in QRSd over time, as measured in years. Clinically important progression of QRSd to ≥ 120 ms was observed in 30% of patients after 2.7 (± 1.5) years and progression of QRSd to ≥ 150 ms was observed in 10% of patients after 2.9 (± 1.2) years. CONCLUSIONS: The natural progression of QRS duration in ICD patients may have serious implications for device implantation. Our study found that the QRS duration increased at a rate of 3.1 ms per year in ICD patients.


Asunto(s)
Terapia de Resincronización Cardíaca/métodos , Causas de Muerte , Electrocardiografía , Taquicardia Ventricular/diagnóstico por imagen , Taquicardia Ventricular/terapia , Adulto , Anciano , Terapia de Resincronización Cardíaca/mortalidad , Estudios de Cohortes , Desfibriladores Implantables , Progresión de la Enfermedad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Pronóstico , Estudios Retrospectivos , Volumen Sistólico/fisiología , Análisis de Supervivencia , Taquicardia Ventricular/mortalidad , Reino Unido
19.
J Am Soc Echocardiogr ; 31(3): 349-360, 2018 03.
Artículo en Inglés | MEDLINE | ID: mdl-29275986

RESUMEN

BACKGROUND: Heart function following heart transplantation (HTx) is influenced by numerous factors. It is typically evaluated using transthoracic echocardiography, but reference values are currently unavailable for this context. The primary aim of the present study was to derive echocardiographic reference values for chamber size and function, including cardiac mechanics, in clinically stable HTx patients. METHODS: The study enrolled 124 healthy HTx patients examined prospectively. Patients underwent comprehensive two-dimensional echocardiographic examinations according to contemporary guidelines. Results were compared with recognized reference values for healthy subjects. RESULTS: Compared with guidelines, larger atrial dimensions were seen in HTx patients. Left ventricular (LV) diastolic volume was smaller, and LV wall thickness was increased. With respect to LV function, both ejection fraction (62 ± 7%, P < .01) and global longitudinal strain (-16.5 ± 3.3%, P < .0001) were lower. All measures of right ventricular (RV) size were greater than reference values (P < .0001), and all measures of RV function were reduced (tricuspid annular plane systolic excursion 15 ± 4 mm [P < .0001], RV systolic tissue Doppler velocity 10 ± 6 cm/sec [P < .0001], fractional area change 40 ± 8% [P < .0001], and RV free wall strain -16.9 ± 4.2% [P < .0001]). Ejection fraction and LV global longitudinal strain were significantly lower in patients with previous rejection. CONCLUSION: The findings of this study indicate that the distribution of routinely used echocardiographic measures differs between stable HTx patients and healthy subjects. In particular, markedly larger RV and atrial volumes and mild reductions in both LV and RV longitudinal strain were evident. The observed differences could be clinically relevant in the assessment of HTx patients, and specific reference values should be applied in this context.


Asunto(s)
Volumen Cardíaco/fisiología , Ecocardiografía Doppler/métodos , Trasplante de Corazón , Ventrículos Cardíacos/diagnóstico por imagen , Volumen Sistólico/fisiología , Receptores de Trasplantes , Función Ventricular Izquierda/fisiología , Adolescente , Adulto , Anciano , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Valores de Referencia , Adulto Joven
20.
Clin Physiol Funct Imaging ; 38(5): 763-771, 2018 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-29076284

RESUMEN

BACKGROUND: Right ventricular (RV) dysfunction may be caused by either pressure or volume overload. RV function is conventionally assessed with echocardiography using tricuspid annular plane systolic excursion (TAPSE), RV fractional area change (RVFAC), tricuspid lateral annular systolic velocity (S') and RV index of myocardial performance (RIMP). The purpose of this study was to evaluate whether RV global longitudinal strain (RVGLS) and RV-free wall strain (RV-free) could add additional information to differentiate these two causes of RV overload. METHODS AND RESULTS: The study enrolled 89 patients with an echocardiographic trans-tricuspid gradient >30 mmHg. Forty-five patients with pulmonary arterial hypertension or chronic thromboembolic pulmonary hypertension (pressure overload) were compared with 44 patients with an atrial septum defect (volume overload). RV size was larger in the volume group (P<0·05). TAPSE and S' were lower in the pressure group (P<0·05, P<0·01). RVFAC was lower in the pressure group (P<0·001) as well as RVGLS (-12·1 ± 3·3% versus -20·2 ± 3·4%, P<0·001) and RV-free (-12·9 ± 3·3% versus -19·4 ± 3·4%, P<0·001). CONCLUSION: In this study, RVGLS and RV-free could more accurately discriminate RV pressure from volume overload than conventional measures. The reason could be that TAPSE and S' are unable to differentiate active deformation from passive entrainment caused by the left ventricle. The pressure group had evidence of marked RV hypertrophy despite standard functional parameters (TAPSE and S) within normal range. This would enhance the value of strain to more sensitively detect abnormal function. A cut-off value of below -16% for RVGLS and RV-free predicts RV pressure overload with high accuracy.


Asunto(s)
Ecocardiografía Doppler/métodos , Ventrículos Cardíacos/diagnóstico por imagen , Contracción Miocárdica , Volumen Sistólico , Disfunción Ventricular Derecha/diagnóstico por imagen , Función Ventricular Derecha , Presión Ventricular , Anciano , Área Bajo la Curva , Fenómenos Biomecánicos , Diagnóstico Diferencial , Femenino , Defectos del Tabique Interatrial/complicaciones , Defectos del Tabique Interatrial/fisiopatología , Ventrículos Cardíacos/fisiopatología , Humanos , Hipertensión Pulmonar/complicaciones , Hipertensión Pulmonar/fisiopatología , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Valor Predictivo de las Pruebas , Estudios Prospectivos , Embolia Pulmonar/complicaciones , Embolia Pulmonar/fisiopatología , Curva ROC , Reproducibilidad de los Resultados , Estudios Retrospectivos , Estrés Mecánico , Válvula Tricúspide/diagnóstico por imagen , Válvula Tricúspide/fisiopatología , Disfunción Ventricular Derecha/etiología , Disfunción Ventricular Derecha/fisiopatología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...