Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 44
Filtrar
1.
Artículo en Inglés | MEDLINE | ID: mdl-38751078

RESUMEN

PURPOSE: The purpose of this study was to investigate whether double-level (femur + tibia) derotational osteotomy is superior to single-level femoral derotational osteotomy for recurrent patellar dislocation with severe femoral and tibial rotational deformities (femoral anteversion >30° and external tibial torsion >30°). METHODS: Between January 2015 and June 2020, a total of 115 knees with recurrent patellar dislocation treated with combined medial patellofemoral ligament reconstruction (MPFL-R) and derotational osteotomies were evaluated after a minimum follow-up of 2 years. Among these cases, 15 knees that underwent double-level derotational osteotomy were included in the double-level group, which was propensity-matched in a 1:2 ratio to a single-level group of patients who underwent single-level femoral derotational osteotomy (30 knees). The clinical and radiological outcomes were evaluated and compared between the groups. Furthermore, the foot progression angle was measured preoperatively and 2 years after surgery. RESULTS: The patient-specific variables did not differ significantly between the double- and the single-level groups after propensity score matching. The postoperative mean foot progression angle was significantly lower in the double-level group than in the single-level group (9° ± 8° vs. 15° ± 11°; p = 0.014); however, there were no statistically significant differences between the groups in terms of any other clinical and radiological assessments. CONCLUSION: For patients with severe femoral and tibial torsional deformities (femoral anteversion >30° and external tibial torsion >30°), the double-level derotational osteotomy is superior to single-level osteotomy in maintaining normal foot progression angle, but it does not show an advantage in terms of patient-reported outcomes, radiological results and redislocation rate at minimum 2 years of follow-up. Furthermore, concomitant excessive external tibial torsion (>30°) did not have an adverse effect on clinical outcomes in patients who underwent derotational distal femoral osteotomy with MPFL-R due to excessive femoral anteversion. LEVEL OF EVIDENCE: Level III.

2.
Artículo en Inglés | MEDLINE | ID: mdl-38651601

RESUMEN

PURPOSE: To explore the relationship between preoperative J-sign grading and structural bone abnormalities in patients with recurrent patellar dislocation (RPD). METHODS: A retrospective study was conducted on RPD patients over 5 years. Patients were categorised based on J-sign grade into low (J- and J1+), moderate (J2+) and high groups (J3+). Trochlear dysplasia (TD) and osseous structures (femoral anteversion angle [FAA], knee torsion, tibial tuberosity-trochlear groove [TT-TG] distance, Caton-Deschamps index) were assessed and grouped according to risk factor thresholds. The χ2 test was used to compare composition ratio differences of structural bone abnormalities among the groups. RESULTS: A total of 256 patients were included, with 206 (80.5%) females. The distribution of J-sign grade was as follows: 89 knees (34.8%) of low grade, 86 moderate (33.6%) and 81 high (31.6%). Among the five structural bone abnormalities, TD was the most common with a prevalence of 78.5%, followed by increased TT-TG at 47.4%. Excessive tibiofemoral rotation had the lowest occurrence at 28.9%. There were 173 (67.6%) patients who had two or more abnormalities, while 45 (17.6%) had four to five bony abnormalities. Among patients with any bony abnormality, the proportion of high-grade J-sign surpassed 40%. Patients with moderate and high-grade J-sign had more increased FAA and more pronounced patella alta (all p < 0.001). The proportion of excessive knee torsion and TD increased with increasing each J-sign grade, with the more notable tendency in knee torsion (high vs. moderate vs. low-grade: 61% vs. 22% vs 7%, p < 0.001). Furthermore, the higher J-sign grade was also associated with more combined bony abnormalities (p < 0.001). In the high-grade J-sign group, 90.2% of the knees had two or more bony risk factors and 40.7% had four or more, which were significantly higher than the moderate and low-grade J-sign groups (40.7% vs. 11.6% vs. 2.2%, p < 0.001). CONCLUSION: In patients with a high-grade J-sign, over 90% of the lower limbs had two or more structural bone risk factors, and more than 40% had four or more. These proportions were significantly higher compared to knees with low-grade and moderate J-sign. In clinical practice, when treating high-grade patellar mal-tracking, it is important to focus on and correct these strongly correlated abnormal bone structures. LEVEL OF EVIDENCE: Level III.

3.
Heliyon ; 10(6): e27627, 2024 Mar 30.
Artículo en Inglés | MEDLINE | ID: mdl-38515710

RESUMEN

The emergence and rapid development of human organoids have provided the possibility to replace animal models in treating human diseases. Intelligence studies help focus on research hotspots and address key mechanistic issues. Currently, few comprehensive studies describe the characteristics of human organoid research. In this study, we extracted 8,591 original articles on organoids from the Web of Science core collection database over the past two decades and conducted intelligence analysis using CiteSpace. The number of publications in this field has experienced rapid growth in the last ten years (almost 70-fold increase since 2009). The United States, China, Germany, Netherlands, and UK have strong collaborations in publishing articles. Clevers Hans, Van Der Laan, Jason R Spence, and Sato Toshiro have made significant contributions to advancing progress in this field. Clustering and burst analysis categorized research hotspots into tissue model and functional construction, intercellular signaling, immune mechanisms, and tumor metastasis. Organoid research in highly cited articles covers four major areas: basic research (38%), involving stem cell developmental processes and cell-cell interactions; biobanking (10%), with a focus on organoid cultivation; precision medicine (16%), emphasizing cell therapy and drug development; and disease modeling (36%), including pathogen analysis and screening for disease-related genetic variations. The main obstacles currently faced in organoid research include cost and technology, vascularization of cells, immune system establishment, international standard protocols, and limited availability of high-quality clinical trial data. Future research will focus on cost-saving measures, technology sharing, development of international standards, and conducting high-level clinical trials.

4.
Orthop Surg ; 16(4): 953-964, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38389204

RESUMEN

OBJECTIVE: Surgical treatment with internal fixation, specifically percutaneous fixation with three cannulated compression screws (CCSs), is the preferred choice for young and middle-aged patients. The mechanical advantage of the optimal spatial configuration with three screws provides maximum dispersion and cortical support. We suspect that the spatial proportion of the oblique triangle configuration (OTC) in the cross-section of the femoral neck isthmus (FNI) may significantly improve shear and fatigue resistance of the fixed structure, thereby stabilizing the internal fixation system in femoral neck fracture (FNF). This study aims to explore the mechanical features of OTC and provide a mechanical basis for its clinical application. METHODS: Twenty Sawbone femurs were prepared as Pauwels type III FNF models and divided equally into two fixation groups: OTC and inverted equilateral triangle configuration (IETC). Three 7.3 mm diameter cannulated compression screws (CCSs) were used for fixation. The specimens of FNF after screw internal fixation were subjected to static loading and cyclic loading tests, respectively, with five specimens for each test. Axial stiffness, 5 mm failure load, ultimate load, shear displacement, and frontal rotational angle of two fragments were evaluated. In the cyclic loading test, the load sizes were 700 N, 1400 N, and 2100 N, respectively, and the fracture end displacement was recorded. Results were presented as means ± SD. Data with normal distributions were compared by the Student's t test. RESULTS: In the static loading test, the axial stiffness, ultimate load, shear displacement, and frontal rotational angle of two fragments were (738.64 vs. 620.74) N/mm, (2957.61 vs. 2643.06) N, (4.67 vs. 5.39) mm, and (4.01 vs. 5.52)° (p < 0.05), respectively. Comparison between the femoral head displacement after 10,000 cycles of 700N cyclic loading and total displacement after 20,000 cycles of 700-1400N cyclic loading showed the OTC group was less than the IETC group (p < 0.05). A comparison of femoral head displacement after 10,000 cycles of 1400N and 2100N cycles and total displacement after 30,000 cycles of 700-2100N cycles showed the OTC group was less than another group, but the difference was not significant (p > 0.05). CONCLUSION: When three CCSs are inserted in parallel to fix FNF, the OTC of three screws has obvious biomechanical advantages, especially in shear resistance and early postoperative weight-bearing, which provides a mechanical basis for clinical selection of ideal spatial configuration for unstable FNF.


Asunto(s)
Fracturas del Cuello Femoral , Cuello Femoral , Persona de Mediana Edad , Humanos , Cuello Femoral/cirugía , Fenómenos Biomecánicos , Fracturas del Cuello Femoral/cirugía , Tornillos Óseos , Fémur , Fijación Interna de Fracturas/métodos
5.
Knee Surg Sports Traumatol Arthrosc ; 32(1): 151-166, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38226710

RESUMEN

PURPOSE: The purpose of this study is to systematically review and quantitatively analyse the clinical outcomes of combined derotational distal femoral osteotomy (D-DFO) and medial patellofemoral ligament reconstruction (MPFL-R) in the treatment of recurrent patellar dislocation (RPD) with increased femoral anteversion angle (FAA). METHODS: This study was performed in line with PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) and AMSTAR (Assessing the Methodological Quality Of Systematic Reviews) Guidelines. PubMed, Embase, Web of Science and Cochrane Library databases were searched to identify studies reporting clinical outcomes of combined D-DFO and MPFL-R in RPD patients with increased FAA. Data on patient-reported outcome measures, radiological parameters, patellar tracking as revealed by J-sign and complications were extracted based on the inclusion criteria. The Methodological Index for Non-Randomized Study score was used for quality assessment. Review Manager and R statistical software were used to perform the statistical analysis. RESULTS: Eleven studies with a total of 569 knees in 553 patients were included. Patients were predominantly female (79%). The weighted mean of FAA decreased from 33.6° to 13.0° (weighted mean difference = 20.59; p < 0.00001) after the combined procedure. Significant improvements (p < 0.00001) were identified in the Lysholm score (weighted mean: 55.5 vs. 80.4), International Knee Documentation Committee (IKDC) score (weighted mean: 52.8 vs. 78.6) and Kujala score (weighted mean: 54.5 vs. 80.6). The incidence of residual J-sign ranged from 14.3% to 38.3% with an overall pooled rate of 28.2% (95% confidence interval = 22.8%-33.6%). The overall redislocation rate was 1.1%. No patients experienced surgical site infection or bone nonunion. Two studies compared the clinical outcomes of MPFL-R with and without D-DFO. Compared with isolated MPFL-R, the combined procedure yielded a better Lysholm score (weighted mean: 84.9 vs. 79.3, p < 0.0001), IKDC score (weighted mean: 84.1 vs. 79.9, p = 0.001), Kujala score (weighted mean: 84.3 vs. 79.4, p < 0.0001) and a lower residual J-sign rate (26/97 [26.8%] vs. 44/105 [41.9%], p = 0.02), respectively. CONCLUSION: The combination of D-DFO and MPFL-R led to improved clinical outcomes and a low redislocation rate in patients with RPD and increased FAA. Additional D-DFO can achieve more favourable results in subjective function and patellar tracking than isolated MPFL-R in the setting of excessive FAA. LEVEL OF EVIDENCE: Level IV.


Asunto(s)
Luxaciones Articulares , Inestabilidad de la Articulación , Luxación de la Rótula , Ligamento Rotuliano , Articulación Patelofemoral , Humanos , Femenino , Masculino , Luxación de la Rótula/cirugía , Articulación Patelofemoral/cirugía , Fémur/cirugía , Osteotomía/métodos , Ligamentos Articulares/cirugía , Inestabilidad de la Articulación/cirugía , Ligamento Rotuliano/cirugía
6.
Eur J Radiol ; 171: 111302, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38219352

RESUMEN

PURPOSE: The aim of our meta-analysis and systematic review was to contrast the positivity rates of [68Ga]Ga-FAPI PET and [18F]FDG PET in detecting bone and lymph node metastases across diverse cancer types. METHODS: We conducted a comprehensive search for eligible articles up until August 2023, utilizing databases including PubMed, Embase, and Web of Science. Studies focusing on the positivity rate of [68Ga]Ga-FAPI PET vs. [18F]FDG PET for bone and lymph metastasis were included. Using random-effect model, the positivity rate for [68Ga]Ga-FAPI PET and [18F]FDG PET were generated. In order to gauge the heterogeneity among aggregated studies, we utilized the I2 statistic. Additionally, we applied the Quality Assessment of Diagnostic Performance Studies (QUADAS-2) methodology to evaluate the caliber of the studies encompassed in our analysis. RESULTS: A total of 430 publications were initially identified in the search. Eventually, 25 studies, involving 779 patients, met the inclusion criteria. In terms of bone metastasis, the findings indicate no statistically significant difference between the use of [68Ga]Ga-FAPI PET and [18F]FDG PET (P = 0.34). However, concerning lymph node metastasis, the results demonstrate significant difference between the two imaging agents (P = 0.04). CONCLUSIONS: This systematic review suggests that [68Ga]Ga-FAPI PET appears to outperform [18F]FDG PET in detecting lymph node metastases. However, when it comes to bone metastasis, no statistically significant difference was observed. It is crucial to acknowledge that the insights concerning bone metastasis stem from studies with comparatively modest sample sizes. Consequently, there is a pressing demand for further, expansive prospective studies in this field.


Asunto(s)
Fluorodesoxiglucosa F18 , Tomografía de Emisión de Positrones , Humanos , Metástasis Linfática/diagnóstico por imagen , Estudios Prospectivos , Bases de Datos Factuales , Tomografía Computarizada por Tomografía de Emisión de Positrones , Radioisótopos de Galio
7.
J Shoulder Elbow Surg ; 33(5): e248-e260, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38182026

RESUMEN

BACKGROUND: Traumatic coronoid deficiency with persistent elbow instability is a challenging condition. Autologous bone graft reconstruction is often associated with a range of additional clinical problems and the outcome is often unpredictable. The purpose of this study was to design a prosthetic device that can reconstruct coronoid deficiency of any height and to evaluate its mechanical properties using finite element analysis. MATERIALS AND METHODS: A customized coronoid prosthesis was designed based on image registration, automatic measurement, and computer-aided design. After pilot study and sample size calculation, image data collected from 6 patients who underwent bilateral complete upper extremity CT scans were reconstructed. The test was divided into 3 groups: coronoid intact, prosthesis and autograft. Regan-Morrey type II and autologous olecranon osteotomy models were established. The prosthesis and autogenous olecranon were assembled to the coronoid base. Stress was applied axially along the proximal humeral diaphysis and implant micromotion and contact mechanics of the humeroulnar joint were measured at 30°, 45°, 60° and 90° of joint flexion respectively. RESULTS: At all flexion angles, the maximum stress on the coronoid articular surface was significantly reduced in the prosthesis and autograft groups, with the reduction being more significant in the latter (P < .001). With increasing flexion, the maximum stress at the coronoid articular surface increased significantly after autograft reconstruction (7.2 to 68 MPa, P < .001), whereas the humeroulnar joint obtained a similar contact mechanics pattern to that of the control group after prosthetic reconstruction. As the flexion angle increased, the relative micromotion of both the prosthesis and autograft increased significantly (0.5-1.6 vs. 0.2-1.2, Pmeasure time < 0.001, Pgroups < 0.001). Contact pressure and center-of-force paths of the humeroulnar joint experience abrupt stress changes at approximately 60° of flexion. CONCLUSION: The contact stress pattern in the humeroulnar joint is similar in prosthesis and intact coronoid groups. Autograft reconstruction increases contact stresses at the articular surface and alters the joint center-of-force path. The "stress surge phenomenon" in the humeroulnar joint surface before and after 60° of flexion may be one of the mechanisms of traumatic elbow degeneration.


Asunto(s)
Articulación del Codo , Inestabilidad de la Articulación , Humanos , Articulación del Codo/diagnóstico por imagen , Articulación del Codo/cirugía , Inestabilidad de la Articulación/diagnóstico por imagen , Inestabilidad de la Articulación/etiología , Inestabilidad de la Articulación/cirugía , Análisis de Elementos Finitos , Proyectos Piloto , Prótesis e Implantes , Rango del Movimiento Articular
8.
J Orthop Traumatol ; 24(1): 50, 2023 Sep 16.
Artículo en Inglés | MEDLINE | ID: mdl-37715867

RESUMEN

BACKGROUND: Both modular and monoblock tapered fluted titanium (TFT) stems are increasingly being used for revision total hip arthroplasty (rTHA). However, the differences between the two designs in clinical outcomes and complications are not yet clear. Here, we intend to compare the efficacy and safety of modular versus monoblock TFT stems in rTHA. METHODS: PubMed, Embase, Web of Science, and Cochrane Library databases were searched to include studies comparing modular and monoblock implants in rTHA. Data on the survivorship of stems, postoperative hip function, and complications were extracted following inclusion criteria. Inverse variance and Mantel-Haenszel methods in Review Manager (version 5.3 from Cochrane Collaboration) were used to evaluate differences between the two groups. RESULTS: Ten studies with a total of 2188 hips (1430 modular and 758 monoblock stems) were finally included. The main reason for the revision was aseptic loosening. Paprosky type III was the most common type in both groups. Both stems showed similar re-revision rates (modular vs monoblock: 10.3% vs 9.5%, P = 0.80) and Harris Hip Scores (WMD = 0.43, P = 0.46) for hip function. The intraoperative fracture rate was 11.6% and 5.0% (P = 0.0004) for modular and monoblock stems, respectively. The rate of subsidence > 10 mm was significantly higher in the monoblock group (4.5% vs 1.0%, P = 0.003). The application of extended trochanteric osteotomy was more popular in monoblock stems (22.7% vs 17.5%, P = 0.003). The incidence of postoperative complications such as periprosthetic femoral fracture and dislocation was similar between both stems. CONCLUSIONS: No significant difference was found between modular and monoblock tapered stems as regards postoperative hip function, re-revision rates, and complications. Severe subsidence was more frequent in monoblock stems while modular ones were at higher risk of intraoperative fracture. LEVEL OF EVIDENCE: Level III, systematic review of randomized control and non-randomized studies. TRIAL REGISTRATION: We registered our study in the international prospective register of systematic reviews (PROSPERO) (CRD42020213642).


Asunto(s)
Artroplastia de Reemplazo de Cadera , Fracturas del Fémur , Fracturas Periprotésicas , Humanos , Reoperación , Bases de Datos Factuales , Fémur
9.
Front Bioeng Biotechnol ; 11: 1155357, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37397969

RESUMEN

Background: The meta-analysis aimed to estimate the efficacy of mesenchymal stem cells on lumbar discogenic pain in patients with intervertebral disc degeneration. Methods: A comprehensive literature search was conducted in the PubMed, Web of Science, Embase and Cochrane Library databases with predetermined search strategy up to 18 September 2022. The clinical studies focusing on evaluating the efficacy and safety of mesenchymal stem cells in patients with intervertebral disc degeneration were identified. The primary outcomes were changes of pain score and Oswestry Disability Index. The Newcastle-Ottawa Scale for cohort studies was used for quality assessment. Review Manager was used to conduct the statistical analysis. Pooled risk ratios were calculated based on the random effect model. Heterogeneity, subgroup, and publication bias analyses were also performed. Results: There were 2,392 studies were identified in the initial search, and 9 eligible studies with 245 patients were eventually included in this review. The Visual Analogue Scale score was significantly lower in patients after receiving mesenchymal stem cells therapy (mean difference = 41.62; 95% confidence interval 24.32 to 58.93; Heterogeneity: I2 = 98%; p < 0.01). And the pooled mean difference of Oswestry Disability Index was 22.04 from baseline to final follow-up points (95% confidence interval 8.75 to 35.33; p = 0.001; Heterogeneity: I2 = 98%; p < 0.001). The pooled reoperation proportion was 0.074 (95% confidence interval 0.009 to 0.175; Heterogeneity: I2 = 72%; p < 0.01). There were no serious related adverse events associated with the therapy. Conclusion: The findings of this meta-analysis indicated that mesenchymal stem cells therapy may be effective in relieving pain and improving Oswestry Disability Index significantly in patients with lumbar discogenic pain. Mesenchymal stem cells therapy may also be associated with a lower risk of adverse events and reoperation rates.

10.
Adv Sci (Weinh) ; 10(21): e2207050, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-37199688

RESUMEN

Degenerative musculoskeletal diseases (DMDs), including osteoporosis, osteoarthritis, degenerative disc disease, and sarcopenia, present major challenges in the aging population. Patients with DMDs present with pain, functional decline, and reduced exercise tolerance, which result in long-term or permanent deficits in their ability to perform daily activities. Current strategies for dealing with this cluster of diseases focus on relieving pain, but they have a limited capacity to repair function or regenerate tissue. Cell-based therapies have attracted considerable attention in recent years owing to their unique mechanisms of action and remarkable effects on regeneration. In this review, current experimental attempts to use cell-based therapies for DMDs are highlighted, and the modes of action of different cell types and their derivatives, such as exosomes, are generalized. In addition, the latest findings from state-of-the-art clinical trials are reviewed, approaches to improve the efficiency of cell-based therapies are summarized, and unresolved questions and potential future research directions for the translation of cell-based therapies are identified.


Asunto(s)
Osteoartritis , Osteoporosis , Humanos , Anciano , Tratamiento Basado en Trasplante de Células y Tejidos , Osteoartritis/terapia , Regeneración , Dolor
11.
J Robot Surg ; 17(4): 1743-1756, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-37017859

RESUMEN

This study aimed to investigate and summarise the current state of research and trends in orthopaedic surgical robots. Data on publicly available publications related to orthopaedic surgical robots were extracted by abstract searches of the Web of Science Core Collection database. A bibliometric analysis and detailed reading of the publications were then carried out and the information was visualised using co-authorship analysis, coupling analysis, co-citation analysis and co-occurrence analysis in VOSviewer. With 436 publications included in the study from 1993 to 2022, the overall contribution of publications to the world showed an increasing trend year by year, with a particularly pronounced after 2017, and a geographical trend of predominantly East Asia, North America, and Western Europe. Of these, China was the largest contributor (n = 128). Overall, the UK affiliates and their scholars were leaders in the field, with a high number of publications, total citations, average citations per article and H-index. The most published institutions and authors were Imperial College London (n = 21) and Professor Fares Sahi Haddad of University College London (n = 12), respectively. Journals with a high overall impact on robotic orthopaedic surgery were the Journal of Arthroplasty, Bone Joint Journal, International Journal of Medical Robotics and Computer Assisted Surgery. Keyword co-occurrence network analysis revealed four main clusters: robot-assisted knee, hip arthroplasty, spine surgery, and robotic technology research and development. The top three most common sites for robot-assisted surgery use were the knee, hip and spine. The most used robot types were the knee and spine, with Mako and Arobot being the most used robots for the knee and TiRobot for the spine. This study comprehensively reveals the current status and trends of global research on orthopaedic surgical robots, covering countries, institutions, authors, journals, research hotspots, robot types and surgical sites, providing directional guidance and research ideas for further research on the technological development and clinical evaluation of orthopaedic surgical robots.


Asunto(s)
Procedimientos Ortopédicos , Ortopedia , Procedimientos Quirúrgicos Robotizados , Robótica , Humanos , Procedimientos Quirúrgicos Robotizados/métodos , Bibliometría
12.
Front Bioeng Biotechnol ; 11: 1141790, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36923459

RESUMEN

Purpose: This study aimed to investigate the biomechanical performance of three Ti6Al4V volar plates with the latest designs using a finite element model. Methods: An AO type 23-A3 distal radius fracture and the models of T plate (2.4 mm LCP Volar Distal Radius Plate), V plate (2.4 mm LCP Two-Column Volar Distal Radius Plate) and π Plate (2.4 mm Volar Rim Distal Radius Plate) (all from Depuy Synthes, West Chester, PA, USA, Ti6Al4V) were built in 3D-matic software. After assembling the internal fixation and fractures, we imported these models into the finite element analysis software (ABAQUS). An axial loading of 100 N was added to the distal end of each model. The displacements of total models and implants, the principal strains and the von Mises stresses in the plates were calculated and compared to capture the biomechanical features of the three plates. Results: The T plate, V plate and π plate represented a model displacement of 0.8414 mm, 1.134 mm and 1.936 mm, respectively. The T plate was with the implant displacement of 0.7576 mm, followed by the V plate (0.8802 mm) and the π plate (1.545 mm). The T plate had the smallest principal strain of 0.23%, the V plate showed an intermediate level of 0.28%, and the π plate had a value of 0.72%. The least peak von Mises stress was observed in the V plate with 263.6MPa, and this value was 435.6 MPa and 1050 MPa in the T plate and π plate, respectively. Conclusion: The biomechanical features of three Ti6Al4V volar locking plates in an AO type 23-A3 fracture were described in our analysis. The T plate and the V plate showed similar biomechanical performance while the π plate represented worse performance than the other two plates.

13.
Artículo en Inglés | MEDLINE | ID: mdl-36833576

RESUMEN

OBJECTIVE: The aim of the present study is to focus on the most popular winter sports programs, and to investigate the global research status and trends in sports-related injuries. METHODS: The Web of Science (WoS) Core Collection database was chosen as original data and used for extracting publications on ice and snow sports injuries on 18 February 2022. Articles published in English between 1995 to 2022 were selected for this study. RESULTS: Finally, for the topic search, a sum of 1605 articles were extracted and used for further analysis. The country and journal ranked first-in terms of total number, total citations and the highest H-index of publications-were the USA and American Journal of Sports Medicine, respectively. The affiliation with the most cited publications was the Norwegian School of Sport Sciences. The most influential first author with the most citations (2537 times), the greatest average citations per article (65.05 times) and the highest H-index (26) was Bahr R. Articles were divided into five main clusters based on keyword analysis: injuries study, head and neck damage study, risk study, therapy study and epidemiology study. Studies related to epidemiology and brain damage in ice and snow sports will continue to be research hot topics. CONCLUSIONS: In conclusion, our study indicates that the ice and snow sports injuries research domain is more prevalent in North America and Europe. This study contributes to a comprehensive understanding of ice and snow sports injuries and provides hotspot directions.


Asunto(s)
Traumatismos en Atletas , Deportes de Nieve , Humanos , Hielo , Bibliometría , Publicaciones
14.
Front Bioeng Biotechnol ; 11: 1111386, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36845182

RESUMEN

Objective: The systematic review aimed to determine the potential side effects of antibacterial coatings in orthopaedic implants. Methods: Publications were searched in the databases of Embase, PubMed, Web of Science and Cochrane Library using predetermined keywords up to 31 October 2022. Clinical studies reporting side effects of the surface or coating materials were included. Results: A total of 23 studies (20 cohort studies and three case reports) reporting the concerns about the side effects of antibacterial coatings were identified. Three types of coating materials, silver, iodine and gentamicin were included. All of studies raised the concerns regarding safety of antibacterial coatings, and the occurrence of adverse events was observed in seven studies. The main side effect of silver coatings was the development of argyria. For iodine coatings, only one anaphylactic case was reported as an adverse event. No systemic or other general side effects were reported for gentamicin. Conclusion: Clinical studies on the side effects of antibacterial coatings were limited. Based on the available outcomes, the most reported side effects of antibacterial coatings in clinical use were argyria with silver coatings. However, researchers should always pay attention to the potential side effects of antibacterial materials, such as systematic or local toxicity and allergy.

15.
Injury ; 54(4): 1047-1054, 2023 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-36759309

RESUMEN

INTRODUCTION: Intramedullary nailing (IMN) is a general treatment for intertrochanteric hip fractures. The computer-assisted orthopaedics system (CAOS), ADAPT system (Stryker, NJ), has been developed to facilitate lag screw insertion. When compared to the conventional freehand method, the efficacy of CAOS has not been clearly clarified. Therefore, we conducted this systematic review and meta-analysis to answer: does the CAOS performed better than freehand method in IMN. MATERIALS AND METHODS: Studies published up to January 2023 were searched in the PubMed, Embase, Web of Science and Cochrane Library databases with predetermined key words. Comparative clinical studies between CAOS (ADAPT system) and freehand method were included. The primary outcomes of interest were the tip-apex-distance (TAD) and positions of lag screw. Fluoroscopy use, operation duration and intraoperative/postoperative complications were also extracted. A meta-analysis was performed for pooled analysis. RESULTS: There were seven studies with 326 fractures in CAOS group and 325 fractures in Freehand group. All studies included presented high qualities. The CAOS group showed a statistically smaller TAD than Freehand group (weighted mean difference = -3.24 mm; 95% confidence interval [CI] -5.10 to -1.37 mm; p = 0.0007) and a better lag screw position (83/92 [90.2%] VS 64/92 [69.6%]; RR = 1.3; 95% CI 1.12 to 1.51; p = 0.0007). The operative time and radiation use revealed no difference between two groups. CONCLUSIONS: The current evidence indicated that ADAPT system could help to perform a more accurate lag screw than freehand manipulation while the operative time and radiation time was not reduced as expectations on such new technique. Long-term follow-up studies are appealed.


Asunto(s)
Fijación Intramedular de Fracturas , Fracturas de Cadera , Ortopedia , Humanos , Fracturas de Cadera/cirugía , Tornillos Óseos , Fijación Intramedular de Fracturas/métodos , Computadores , Resultado del Tratamiento , Clavos Ortopédicos
16.
Injury ; 54 Suppl 2: S86-S94, 2023 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-35219538

RESUMEN

OBJECTIVES: In this study, we evaluated the biomechanical characteristics of different locations of medial fixation strategies in double-plate osteosynthesis for fixing AO/ASIF type 33-C2 femoral fractures by means of finite element analysis. METHODS: We used 3-matic software and UG-NX software to construct AO/ASIF type 33-C2 Femoral fractures and lateral less invasive stabilization system (LISS) plates, medial plates (MPs), and medial support pads (MSPs), respectively. Then, the LISS, MP and MSP were assembled into the fracture model separately to form three fixation models: MSP+LISS, anteromedial plate (AMP+LISS), and MP+LISS. In the next procedure, we performed finite element analysis using ANSYS software after meshing the elements of the models in HyperMesh 11.0 software. Loading conditions including lateral-medial four-point bending, anterior-posterior four-point bending, axial loading, and torsional loading were applied to evaluate the biomechanical advantages among the three fixation types. We observed the peak Von Mises Stress (VMS) value, maximum displacement, bending angle in the coronal plane of the fracture, and torsional angle of the fracture to assess the degree of plate deformation and fixation stability. RESULTS: Our results showed that in both lateral-medial four-point bending and anterior-posterior four-point bending, the calculations of MP+LISS were marginally better than those of AMP+LISS. However, with the action of axial loading and torsional loading, the deformation of MP+LISS was distinctly smaller than that of AMP+LISS, and the fixation stability of MP+LISS was also prominently better. Under lateral-medial four-point bending, the VMS on the lateral plate of MSP+LISS (59.977 MPa) was approximately half of the two double-plate models. Under anterior and posterior four-point bending, the 38.209 MPa peak VMS of MSP+LISS was still superior to the other two double-plate models. Under torsional loading, the peak VMS (347.75 MPa), the maximum torsional angle of the femoral head (7.852 °), and the torsional angle of fracture (0.036 °) of MSP+LISS preceded those of the other two models. However, under axial loading, the peak VMS (76.376 MPa) and the maximum displacement (3.1798 mm) of MSP+LISS were slightly higher than those of MP+LISS. CONCLUSION: The MSP+LISS model showed better biomechanical performance than the double-plate models, which might be an effective solution for the treatment of comminuted distal femur fractures.


Asunto(s)
Fracturas Femorales Distales , Fracturas del Fémur , Humanos , Análisis de Elementos Finitos , Fracturas del Fémur/cirugía , Fijación Interna de Fracturas , Placas Óseas
18.
Surg Radiol Anat ; 45(2): 215-224, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-36509883

RESUMEN

PURPOSE: To perform quantitative measurements of the anatomic morphology of the proximal ulna and establish the morphologic references based on Chinese for the surgical protocol and implant design. METHODS: The computed tomography data of 156 upper extremities were involved in this study. The ulna model was reconstructed in Mimics. Ten distance and 6 angle parameters were measured by 4 independent investigators with a new quantitative measurement method. The intraclass correlation coefficient was used to evaluate the measuring reliability. Gender and side differences of measured parameters were evaluated. RESULTS: Measurements showed a mean coronoid height of 15 mm, which was 42% of ulnar height with gender-specific differences (mean 16 mm in men and 14 mm in women, P < 0.001). A mean unsupported anteromedial facet width of 8 mm was 61% of the coronoid anteromedial facet. A larger opening angle correlates to a larger olecranon-diaphysis angle (P < 0.001) and larger coronoid height (P = 0.001). A mean proximal ulna dorsal angulation of 4.7° is present in 80% of models at an average of 52 mm distal to olecranon tip. The average proximal ulna varus angulation was 16° at a mean of 74 mm distal to the olecranon tip. Morphological features between the left and right sides were highly consistent. The ICC was between 0.789 and 0.978 for inter-observer and between 0.696 and 0.997 for intra-observer reliability. CONCLUSIONS: The proximal ulna features variable morphology but minor side differences among individuals. Over half of the anteromedial facet was not supported by the proximal ulnar diaphysis, making the coronoid vulnerable to elbow trauma. Preconditioning or customized design of the ulnar plate in the clinical setting with the help of contralateral morphology may be a good choice.


Asunto(s)
Articulación del Codo , Olécranon , Masculino , Humanos , Femenino , Codo , Reproducibilidad de los Resultados , Cúbito/diagnóstico por imagen , Cúbito/anatomía & histología , Olécranon/anatomía & histología , Articulación del Codo/anatomía & histología
19.
Int J Bioprint ; 8(4): 607, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36404790

RESUMEN

Precise and shape-matching osteotomy models are determinants of the experimental homogeneity in the assessment of orthopedic biomechanical properties. At present, however, publications on detailed description of osteotomy in bone biomechanical study are scanty. The purposes of this study were to design a new method of osteotomy-aided module production for bone biomechanical study with the help of three-dimensional (3D) printing and computer-aided design (CAD) and to test the accuracy of osteotomy. Fourteen fourth-generation composite femurs were analyzed. The composite bone was scanned using computed tomography (CT) scanner and loaded in Mimics for reconstruction and, then, imported into 3-Matic software to design intertrochanteric region, distal femur, and rotation control lever models. 3D printer was used to print each component. After assembling Sawbones and osteotomy modules, a horizontal band-saw was used to create fracture models. The volume and mass of intermediate fragments were calculated and analyzed. Satisfactory osteotomies of all composite Sawbones were achieved. The mean volume and mass of intermediate fragments were 21.0 ± 1.5 mm3 and 19.0 ± 1.2 g, respectively. Range of deviation from average of volumes was -1.9 - 2.8 mm3 and most of these deviations fall within the range of -1.4 - 2.1 mm3. Range of deviation from average of mass was -2.0 - 1.6 g and most of these deviations fall within the range of -1.4 - 1.6 g. One-dimensional histogram of deviation from average shows the precise and stable osteotomy performed based on the modules accordingly. A new method of osteotomy-aided module production for bone biomechanical study with the help of 3D printing and CAD was designed and the accuracy of osteotomy was verified. This method is expected to achieve homogeneity and standardization of osteotomy in bone biomechanical study.

20.
Front Surg ; 9: 930707, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36439520

RESUMEN

Objective: The meta-analysis aimed to estimate the efficacy of prophylactic tamsulosin on postoperative urinary retention (POUR) in male patients. Methods: Papers were searched in the PubMed, Embase, Web of Science, and Cochrane Library databases with predetermined keywords up to March 1, 2022. The studies reporting the preventive efficacy of prophylactic tamsulosin on POUR among men were identified. Pooled risk ratios (RRs) were calculated based on the random-effects model. Meta-regression was performed to explore potential sources of heterogeneity. Results: There were 11 studies with 1,046 patients in the tamsulosin group and 1,113 patients in the control group. The risk of POUR was significantly lower in the tamsulosin group (123/1,046 [11.8%] vs. 238/1,119 [19.0%]; RR = 0.61; 95% confidence interval [CI] 0.43 to 0.87; P = 0.006; heterogeneity: I 2 = 57%; P = 0.009). Administration of tamsulosin was related to higher risk of adverse events (57/688 [8.3%] vs. 33/624 [5.3%]; RR = 1.68; 95% CI: 1.13 to 2.48; P = 0.010; heterogeneity: I 2 = 33%; P = 0.20). The level of evidence and mean age of the included patients were identified as the potential sources of heterogeneity. Conclusion: The present meta-analysis indicated that prophylactic tamsulosin helps in preventing POUR and younger patients might benefit more from this preventive regimen. Administrating tamsulosin was also associated with a possibly higher risk of adverse events.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...