Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Artículo en Inglés | MEDLINE | ID: mdl-34462638

RESUMEN

Red yeast rice is a traditional Chinese medicine and food that has been purported to color food, ferment, and lower cholesterol. In order to study the antioxidative capacity of red yeast rice and the effects on electrical potential difference (EPD) of 12 acupuncture meridians, the pH value, oxidation reduction potential (ORP), ABTS, FRAP, T-SOD, and particle size distribution of red yeast rice were analyzed. 20 volunteers were recruited and randomly divided into two groups, the red yeast rice group (10 g red yeast rice and 40 g water) and control CK group (50 g water). The left 12 acupuncture meridians' EPD was real-time monitored. Samples were taken at the 10th minutes. The whole procedure continued for 70 minutes. It is shown that the pH value of the red yeast rice was 4.22, the ORP was 359.63 mV, the ABTS was 0.48 mmol Trolox, the FRAP was 0.08 mmol FeSO4, the T-SOD was 4.71 U, and the average particle size was 108 nm (7.1%) and 398.1 nm (92.9%). The results of 12 acupuncture meridians' EPD showed that the red yeast rice can significantly affect the EPD of stomach, heart, small intestine, and liver meridians.

2.
Sichuan Da Xue Xue Bao Yi Xue Ban ; 46(5): 777-82, 2015 Sep.
Artículo en Chino | MEDLINE | ID: mdl-26619556

RESUMEN

UNLABELLED: [ABSTRACT] OBJECTIVE: To determine the value of low dose spiral CT scanning in diagnosing impacted teeth of children and adolescents. METHODS: A total of 153 children and adolescents with confirmed impacted teeth in West China Second University Hospital, Sichuan University were enrolled in this study. They were divided into 5 groups according to the different spiral CT scan parameters (tube current time product, scanning thickness and collimation value): Group A (n=30, 330 mAs, 6 X 0. 75 mm and 3. 0 mm), Group B (n=30, 140 mAs, 6 X 0. 75 mm and 3. 0 mm), Group C (n=30, 80 mAs, 6 X 0. 75 mm and 3. 0 mm), Group D (n=31, 80 mAs, 6 X 1. 50 mm and 5. 0 mm), and Group E (n=32, 50 mAs, 6 X 1. 50 mm and 5. 0 mm). There were no significant differences in general clinical features (P>0. 05) among the participants of the five groups. The phantoms were used to measure spatial resolution and contrast resolution of the scan images. Dose length product (DLP) was recorded during CT scanning for calculating effective dose (ED) of exposure. The quality of images was evaluated using a list of quality scoring criteria. RESULTS: (1) Under 330, 140, 80, 80 and 50 mAs, the images had a spatial resolution of 1.0 mm, with contrast resolution of 2. 0, 3. 0, 4. 5, 4. 5 and 6. 0 mm, respectively. (2) Significant differences in ED values were found among the five groups (F=1 064. 119, P=0. 000) and between every two of those groups (P<0. 05). Group E had the lowest ED (0. 19 mSv), 86. 52%, 67. 24%, 45. 71%, and 38. 71% lower than that in Group A, B, C and D, respectively (P<0. 05). (3) All of the five groups obtained an image quality score above 3, and no statistical differences appeared among the 5 groupl (F=1. 978, P>0. 05). The diagnostic results of the spiral CT were consistent with those of orthodontic surgery. CONCLUSION: Low dose spiral CT scanning can meet the image quality requirements for diagnosing impacted teeth, minimizing radiation exposure effectively.


Asunto(s)
Dosis de Radiación , Tomografía Computarizada Espiral , Diente Impactado/diagnóstico , Adolescente , Niño , China , Humanos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...