Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 68
Filtrar
1.
Medicine (Baltimore) ; 103(28): e38984, 2024 Jul 12.
Artículo en Inglés | MEDLINE | ID: mdl-38996097

RESUMEN

RATIONALE: Aggressive fibromatosis (AF) is a fibroblastic/myofibroblastic tumor known for its locally aggressive properties. Intra-abdominal AF primarily occurs in the small intestine mesentery, ileocolic mesocolon, omentum, retroperitoneum, and pelvis, and rarely originates from the intestinal wall. Here, we report a rare case of small bowel obstruction caused by duodenum-derived AF with ß-catenin (CTNNB1) T41A mutation. PATIENT CONCERNS: A 35-year-old male had a 4-month history of abdominal pain, nausea, and vomiting, which gradually worsened over time. DIAGNOSES: Based on the results of CT examination, histopathology and Sanger sequencing, the patient was diagnosed with small bowel obstruction caused by duodenum-derived AF. INTERVENTIONS: Due to the extensive adhesion between the tumor and surrounding tissue, it is extremely challenging to completely remove the tumor through surgical resection with negative margins in this case. In order not to damage the function of surrounding vital organs, gastrojejunostomy was performed to relieve the symptoms of small bowel obstruction. OUTCOMES: The patient experienced a successful recovery. It is important to note that this patient is still at risk of local recurrence and requires regular follow-up. LESSONS: The best treatment should be taken based on the individual patient to relieve symptoms and improve quality of life. Moreover, histopathology plays a crucial role in diagnosing and differentiating duodenum-derived AF. The detection of mutations in exon 3 of the CTNNB1 has become strong evidence for diagnosing duodenum-derived AF.


Asunto(s)
Fibromatosis Agresiva , Obstrucción Intestinal , Mutación , beta Catenina , Humanos , Masculino , Adulto , Obstrucción Intestinal/etiología , Obstrucción Intestinal/cirugía , Obstrucción Intestinal/genética , Obstrucción Intestinal/diagnóstico , beta Catenina/genética , Fibromatosis Agresiva/genética , Fibromatosis Agresiva/complicaciones , Fibromatosis Agresiva/diagnóstico , Fibromatosis Agresiva/cirugía , Intestino Delgado/patología , Neoplasias Duodenales/genética , Neoplasias Duodenales/cirugía , Neoplasias Duodenales/complicaciones , Neoplasias Duodenales/diagnóstico
2.
Orthop Surg ; 16(5): 1168-1174, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38584130

RESUMEN

OBJECTIVE: The different cutting mode of robot-assisted TKAs may influence the accuracy of alignment. The purpose of this study was to compare alignment accuracy and early clinical outcomes between a CT-based, saw cutting robotic system (MAKO) and a CT-free, jig-guided robotic system (ROSA) for total knee arthroplasty (TKA). METHODS: A total of 20 MAKO TKAs and 20 ROSA TKAs from June 2021 to June 2022 were retrospectively analyzed. Differences in the postoperative hip-knee-ankle (HKA) angle, lateral distal femoral angle (LDFA), medial proximal tibial angle (MPTA), posterior tibial slope (PTS) and 3° outlier frequency of the HKA, LDFA, MPTA and PTS were studied at 3 months and 1 year of follow-up. The operative time and total blood loss (TBL) were compared between these two groups. Clinical outcomes at 1 year after surgery, including range of motion (ROM), Western Ontario McMaster University Osteoarthritis Index (WOMAC) score, and Knee Society Score-2011 (KSS-2011), were also compared between these two groups. RESULTS: The baseline characteristics of the two groups were comparable. There were no significant differences in the mean deviations of postoperative HKA, LDFA, MPTA or PTS between the two groups at 3 months or 1 year (all ps > 0.05). Moreover, there was no significant difference in the percentage of 3° outliers for HKA, LDFA, MPTA, or PTS between the two groups at 3-month or 1-year follow-up (all ps > 0.05). The mean operation time of MAKO was longer than that of ROSA (112.7 ± 12.8 min vs 94.8 ± 23.0 min, p = 0.001), but the mean TBL (1356.7 ± 648.5 mL vs 1384.5 ± 676.3 mL) and transfusion rate (15.0% vs 5.0%) were not significantly different between the two groups (all ps > 0.05). No significant differences were found in postoperative ROM, WOMAC score or KSS score at 1 year (all ps > 0.05). CONCLUSION: The MAKO and ROSA had similar accuracy and precision in TKA alignment. The clinical outcomes at 1 year after surgery were also comparable.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Procedimientos Quirúrgicos Robotizados , Tomografía Computarizada por Rayos X , Humanos , Artroplastia de Reemplazo de Rodilla/métodos , Artroplastia de Reemplazo de Rodilla/instrumentación , Procedimientos Quirúrgicos Robotizados/métodos , Femenino , Masculino , Estudios Retrospectivos , Anciano , Persona de Mediana Edad
3.
J Funct Biomater ; 15(4)2024 Apr 18.
Artículo en Inglés | MEDLINE | ID: mdl-38667566

RESUMEN

In recent years, the use of zinc (Zn) alloys as degradable metal materials has attracted considerable attention in the field of biomedical bone implant materials. This study investigates the fabrication of porous scaffolds using a Zn-1Mg-0.1Sr alloy through a three-dimensional (3D) printing technique, selective laser melting (SLM). The results showed that the porous Zn-1Mg-0.1Sr alloy scaffold featured a microporous structure and exhibited a compressive strength (CS) of 33.71 ± 2.51 MPa, a yield strength (YS) of 27.88 ± 1.58 MPa, and an elastic modulus (E) of 2.3 ± 0.8 GPa. During the immersion experiments, the immersion solution showed a concentration of 2.14 ± 0.82 mg/L for Zn2+ and 0.34 ± 0.14 mg/L for Sr2+, with an average pH of 7.61 ± 0.09. The porous Zn-1Mg-0.1Sr alloy demonstrated a weight loss of 12.82 ± 0.55% and a corrosion degradation rate of 0.36 ± 0.01 mm/year in 14 days. The Cell Counting Kit-8 (CCK-8) assay was used to check the viability of the cells. The results showed that the 10% and 20% extracts significantly increased the activity of osteoblast precursor cells (MC3T3-E1), with a cytotoxicity grade of 0, which indicates safety and non-toxicity. In summary, the porous Zn-1Mg-0.1Sr alloy scaffold exhibits outstanding mechanical properties, an appropriate degradation rate, and favorable biosafety, making it an ideal candidate for degradable metal bone implants.

4.
Orthop Surg ; 15(11): 3006-3011, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37749766

RESUMEN

BACKGROUND: Primary hyperparathyroidism (PHPT) is an endocrine disorder with high serum calcium and parathyroid hormone (PTH) levels. Excessive secretion of PTH can cause bone loss and may have potential damage to implant fixation after total knee arthroplasty (TKA). However, there is currently no research or literature reporting prosthesis loosening after TKA associated with PHPT. CASE PRESENTATION: This case report describes a TKA failure of tibial prothesis loosening associated with PHPT. The patient faced aggravated pain and difficulty in walking 6 months after the primary TKA. Further examinations showed high serum calcium and PTH levels indicating the presence of PHPT. After the surgery of parathyroidectomy, the patient received revision TKA with 3D-printed metaphyseal cone. Knee symptoms and function were finally improved. CONCLUSION: PHPT is a risk factor for prosthesis loosening after TKA. Preoperative screening test of serum calcium and PTH levels is important to diagnose PHPT. For patients with PHPT undergoing TKA, preoperative endocrinotherapy and parathyroidectomy are recommended to improve the survival of prosthesis.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Hiperparatiroidismo Primario , Humanos , Calcio , Hiperparatiroidismo Primario/complicaciones , Hiperparatiroidismo Primario/cirugía , Falla de Prótesis , Hormona Paratiroidea
5.
Orthop Surg ; 15(11): 2937-2946, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37712186

RESUMEN

OBJECTIVES: The reconstruction of bone defects in tibial revision knee arthroplasty is challenging. In this study, we evaluated the primary stability of a novel three-dimensional (3D)-printed custom-made metaphyseal cone for Anderson Orthopedic Research Institute (AORI) IIb or III bone defect reconstruction in tibial revision knee arthroplasty using the combination of finite-element analysis and biomechanical experiments. METHODS: In the finite-element analysis, AORI II b and III medial tibial bone defects were designed at varying depths. A novel 3D-printed custom-made metaphyseal cone was designed and used to reconstruct the bone defect with or without a stem in simulated revision total knee arthroplasty (RTKA). A no-stem group and a stem group were established (based on whether a stem was used or not). Von Mises stress and micromotion were calculated with varying depths of bone defects, ranging from 5 mm to 35 mm, and then micromotions at the bone-implant interface were calculated and compared with the critical value of 150 µm. In the biomechanical experiment, the no-stem group was used, and the same bone defects were made in four synthetic tibias using patient-specific instruments. Micromotions at the bone-implant interface were investigated using a non-contact optical digital image correlation system and compared with the critical value of 150 µm. RESULTS: When the bone defect was <30 mm, micromotions at the bone-implant interface in the finite-element analysis were all below 150 µm both in the stem groups and no-stem groups, whereas those in the biomechanical experiment were also below 150 µm in the no-stem group. CONCLUSIONS: The 3D-printed custom-made metaphyseal cone in RTKA has excellent primary stability and does not require stems in reconstructing tibial AORI type IIb or III bone defects with a depth of <30 mm.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Humanos , Tibia/cirugía , Análisis de Elementos Finitos , Artroplastia de Reemplazo de Rodilla/métodos , Huesos , Reoperación , Diseño de Prótesis , Articulación de la Rodilla/cirugía
6.
Molecules ; 28(13)2023 Jun 23.
Artículo en Inglés | MEDLINE | ID: mdl-37446595

RESUMEN

The internal three-dimensional characteristics of X-ray microtomography (micro-CT) has great application potential in the field of bronze corrosion. This work presents a method of simulating bronze disease based on an in situ micro-CT image to study the characteristics of the oxidative hydrolysis reactions of copper(I) chloride and copper(II) chloride dihydrate. A series of high-resolution reconstruction images were obtained by carrying out micro-CT at three key points throughout the experiment. We found that the reactions of copper(I) chloride and copper(II) chloride dihydrate showed different characteristics at different stages of the simulation in the micro-CT view. The method proposed in this work specifically simulated one single type of bronze corrosion and characterized the evolution characteristics of simulated bronze disease. It provides a new perspective to investigate bronze disease and can help improve the subsequent use of micro-CT to distinguish real bronze corrosions.


Asunto(s)
Cobre , Halógenos , Microtomografía por Rayos X/métodos , Cloruros
7.
BMC Musculoskelet Disord ; 24(1): 378, 2023 May 12.
Artículo en Inglés | MEDLINE | ID: mdl-37173724

RESUMEN

BACKGROUND: Knee osteoarthritis (KOA) causes not only pain, stiffness, and dysfunction of the knee, but also the reduction of the joint range of motion (ROM). This study explored the demographic and radiographic factors for knee symptoms and ROM in patients with symptomatic KOA. METHODS: The demographic variables, Kellgren-Lawrence (KL) grade, and the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) of patients with symptomatic KOA recruited in Beijing were collected. The knee ROM of all patients were also measured. We analyzed the influencing factors for WOMAC and ROM using a generalize linear model, respectively. RESULTS: This study included a total of 2034 patients with symptomatic KOA, including 530 males (26.1%) and 1504 females (73.0%), with a mean age of 59.17 (± 10.22) years. Patients with advanced age, overweight or obesity, a family history of KOA, a moderate-to-heavy manual labor job and use of nonsteroidal anti-inflammatory drugs (NSAIDs) had significantly higher WOMAC and lower ROM (all P < 0.05). The more the comorbidities, the higher the WOMAC (all P < 0.05). Patients with higher education had better ROM than those with only an elementary education(ß = 4.905, P < 0.05). Compared with those KL = 0/1, the WOMAC of patients whose KL = 4 were higher (ß = 0.069, P < 0.05), but the WOMAC of those KL = 2 were lower (ß = -0.068, P < 0.05). ROM decreased with the increase of KL grade (all P < 0.05). CONCLUSIONS: KOA patients with advanced age, overweight or obesity, a family history of KOA in first-degree relatives, a moderate-to-heavy manual labor job tended to have more severe clinical symptoms and worse ROM. Patients with more severe imaging lesions tend to have poorer ROM. Symptom management measures and regular ROM screening should be taken early to these people.


Asunto(s)
Osteoartritis de la Rodilla , Masculino , Femenino , Humanos , Persona de Mediana Edad , Osteoartritis de la Rodilla/diagnóstico por imagen , Osteoartritis de la Rodilla/epidemiología , Beijing , Estudios Transversales , Sobrepeso , Articulación de la Rodilla , Rango del Movimiento Articular , Obesidad , Demografía
8.
Materials (Basel) ; 16(7)2023 Mar 29.
Artículo en Inglés | MEDLINE | ID: mdl-37049026

RESUMEN

In this work, the effect of the Ru element on the γ'-phase evolution and deformation mechanism in the fourth-generation Ni-based single-crystal superalloy was investigated. Results show that the Ru element alters the distribution coefficient of other elements in the alloy to produce reverse partitioning behavior, which leads to a difference in microstructure between 0Ru and 3Ru. The addition of Ru triggered the incubation period before the beginning of the primary creep stage, which depends on the creep temperature and stress during creep deformation. TEM results revealed that Ru addition inhibits the slip system {111}<112> at medium-temperature (760-1050 °C) and high-stress (270-810 MPa) creep, which brings a considerably low creep rate and high creep life to the Ru-containing alloy.

9.
Materials (Basel) ; 16(8)2023 Apr 11.
Artículo en Inglés | MEDLINE | ID: mdl-37109844

RESUMEN

A novel fourth-generation nickel-based single crystal superalloy was brazed with Co-based filler alloy. The effects of post-weld heat treatment (PWHT) on the microstructure and mechanical properties of brazed joints were investigated. The experimental and CALPHAD simulation results show that the non-isothermal solidification zone was composed of M3B2, MB-type boride and MC carbide, and the isothermal solidification zone was composed of γ and γ' phases. After the PWHT, the distribution of borides and the morphology of the γ' phase were changed. The change of the γ' phase was mainly attributed to the effect of borides on the diffusion behavior of Al and Ta atoms. In the process of PWHT, stress concentration leads to the nucleation and growth of grains during recrystallization, thus forming high angle grain boundaries in the joint. The microhardness was slightly increased compared to the joint before PWHT. The relationship between microstructure and microhardness during the PWHT of the joint was discussed. In addition, the tensile strength and stress fracture life of the joints were significantly increased after the PWHT. The reasons for the improved mechanical properties of the joints were analyzed and the fracture mechanism of the joints was elucidated. These research results can provide important guidance for the brazing work of fourth-generation nickel-based single crystal superalloy.

10.
Quant Imaging Med Surg ; 13(3): 1753-1767, 2023 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-36915302

RESUMEN

Background: This study aimed to clarify the spontaneous neural activity in the conventional frequency band (0.01-0.08 Hz) and 2 subfrequency bands (slow-4: 0.027-0.073 Hz; slow-5: 0.01-0.027 Hz) in patients with extracranial multi-organ tuberculosis (EMTB) through regional homogeneity (ReHo) analysis. Methods: In all, 32 patients with EMTB and 31 healthy controls (HCs) were assessed by resting-state functional magnetic resonance imaging (rs-fMRI) scans to clarify the abnormal spontaneous neural activity through ReHo analysis in the conventional frequency band and 2 subfrequency bands. Results: Compared with the HCs, the patients with EMTB exhibited decreased ReHo in the left postcentral gyrus [t=-4.79; 95% confidence interval (CI): -0.79 to -0.31] and the left superior cerebellum (t=-4.45; 95% CI: -0.54 to -0.21) in the conventional band. Conversely, increased ReHo was observed in the right middle occipital gyrus (t=3.94; 95% CI: 0.18-0.53). In the slow-4 band, patients with EMTB only exhibited decreased ReHo in the superior cerebellum (t=-4.69; 95% CI: -0.54 to -0.22); meanwhile, in the slow-5 band, these patients exhibited decreased ReHo in the right postcentral gyrus (t=-3.76; 95% CI: -0.74 to -0.21) and the left superior cerebellum (t=-5.20, 95% CI: -0.72 to -0.31). After Bonferroni correction, no significant correlation was observed between the ReHo values in clusters showing significant between-group differences and cognitive test scores. Conclusions: ReHo showed abnormal synchronous neural activity in patients with EMTB in different frequency bands, which provides a novel understanding of the pathological mechanism of EMTB.

12.
Clin Appl Thromb Hemost ; 29: 10760296221139263, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36596268

RESUMEN

Deep vein thrombosis (DVT) is a common postoperative complication of knee/hip arthroplasty. There is a continued need for artificial intelligence-based methods of predicting lower extremity DVT risk after knee/hip arthroplasty. In this study, we performed a retrospective study to analyse the data from patients who underwent primary knee/hip arthroplasty between January 2017 and December 2021 with postoperative bilateral lower extremity venous ultrasonography. Patients' features were extracted from electronic health records (EHRs) and assigned to the training (80%) and test (20%) datasets using six models: eXtreme gradient boosting, random forest, support vector machines, logistic regression, ensemble, and backpropagation neural network. The Caprini score was calculated according to the Caprini score measurement scale, and the corresponding optimal cut-off Caprini score was calculated according to the largest Youden index. In total, 6897 cases of knee/hip arthroplasty were included (average age, 65.5 ± 8.9 years; 1702 men), among which 1161 (16.8%) were positive and 5736 (83.2%) were negative for deep vein thrombosis. Among the six models, the ensemble model had the highest area under the curve [0.9206 (0.8956, 0.9364)], with a sensitivity, specificity, positive predictive value, negative predictive value, and F1 score of 0.8027, 0.9059, 0.6100, 0.9573 and 0.7003, respectively. The corresponding optimal cut-off Caprini score was 10, with an area under the curve, sensitivity, specificity, positive predictive value, and negative predictive values of 0.5703, 0.8915, 0.2491, 0.1937, 0.9191, and 0.3183, respectively. In conclusion, machine learning models based on EHRs can help predict the risk of deep vein thrombosis after knee/hip arthroplasty.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Trombosis de la Vena , Masculino , Humanos , Persona de Mediana Edad , Anciano , Estudios Retrospectivos , Artroplastia de Reemplazo de Cadera/efectos adversos , Inteligencia Artificial , Trombosis de la Vena/etiología , Extremidad Inferior , Complicaciones Posoperatorias/etiología , Factores de Riesgo
13.
J Mater Chem B ; 11(6): 1203-1212, 2023 02 08.
Artículo en Inglés | MEDLINE | ID: mdl-36515141

RESUMEN

Osseointegration is vital for the success of non-degradable implants like those made of titanium alloys. In order to promote osseointegration, implants are made porous, providing space for bone ingrowth. Despite extensive optimization of the pore geometry and porosity, bone ingrowth into implants is still marginal; further modification to promote bone ingrowth as well as osseointegration becomes paramount. In this study, a pH neutral bioactive glass with the composition of 10.8% P2O5-54.2% SiO2-35% CaO (mol%; hereinafter referred to as PSC) was successfully coated on 3D-printed porous Ti6Al4V scaffolds using an in situ sol-gel method. This PSC coating is strongly bonded to the substrate and quickly induces the formation of hydroxyapatite on the scaffold surface upon contact with body fluid. In vitro, the PSC-coated Ti6Al4V scaffolds showed superior biocompatibility, cell proliferation promotion, cell adhesion, osteogenic differentiation and mineralization compared to their bare counterparts, implying better osseointegration. In vivo experiments confirmed this expectation; after being implanted, the coated scaffolds had more bone ingrowth and osseointegration, and consequently, higher push-out strength was achieved, proving the validity of the proposed concept in this study. In conclusion, PSC coating on 3D-printed porous Ti6Al4V scaffolds can improve osteogenesis, bone ingrowth, and osseointegration. Together with the versatility of this in situ sol-gel coating method, titanium alloy implants with better biological performances may be developed for immediate clinical applications.


Asunto(s)
Oseointegración , Osteogénesis , Porosidad , Titanio/química , Dióxido de Silicio , Aleaciones , Impresión Tridimensional , Concentración de Iones de Hidrógeno
15.
Quant Imaging Med Surg ; 12(8): 4120-4134, 2022 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-35919063

RESUMEN

Background: Resting-state functional magnetic resonance imaging (rs-fMRI) is widely used to study brain functional alteration, but there have been no reports of research regarding the application of rs-fMRI in intracranial tuberculosis. The purpose of this prospective, cross-sectional study was to investigate spontaneous neural activity at different frequency bands in patients with intracranial tuberculosis using rs-fMRI with amplitude of low-frequency fluctuation (ALFF) and fractional ALFF (fALFF) methods. Methods: The rs-fMRI data of 31 patients with intracranial tuberculosis and 30 gender-, age-, and education-matched healthy controls (HCs) were included. The ALFF and fALFF values in the conventional frequency band (0.01-0.08 Hz) and 2 sub-frequency bands (slow-4: 0.027-0.073 Hz; slow-5: 0.01-0.027 Hz) were calculated and compared between the groups. The resultant T-maps were corrected using the Gaussian random field (GRF) theory (voxel P<0.01, cluster P<0.05). Correlations between the ALFF and fALFF values and neurocognitive scores were assessed. Results: Compared with the HCs, patients with intracranial tuberculosis showed decreased ALFF in the right paracentral lobule (T=-4.69) in the conventional frequency band, in the right supplementary motor area (T=-4.85) in the slow-4 band, and in the left supplementary motor area (T=-3.76) in the slow-5 band. Compared to the slow-5 band, the voxels with decreased ALFF were spatially more extensive in the slow-4 band. Compared with HCs, patients with intracranial tuberculosis showed decreased fALFF in the opercular parts of the right inferior frontal gyrus (T=-4.50) and the left inferior parietal lobe (T=-4.86) and increased fALFF in the left inferior cerebellum (T=5.84) in the conventional frequency band. In the slow-4 band, fALFF decreased in the opercular parts of the right inferior frontal gyrus (T=-5.29) and right precuneus (T=-4.34). In the slow-5 band, fALFF decreased in the left middle occipital gyrus (T=-4.65) and right middle frontal gyrus (T=-5.05). Conclusions: Patients with intracranial tuberculosis showed abnormal intrinsic brain activity at different frequency bands, and ALFF abnormalities in different brain regions could be better detected in the slow-4 band. This preliminary study might provide new insights into understanding the pathophysiological mechanism in intracranial tuberculosis.

16.
Breast Cancer Res Treat ; 195(3): 301-310, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-35917052

RESUMEN

PURPOSE: For estrogen receptor (ER)-positive breast cancer, neoadjuvant endocrine therapy (NET) has been shown to be as effective as neoadjuvant chemotherapy (NACT). We evaluated the prognostic significance of Preoperative Endocrine Prognostic Index (PEPI). METHODS: We conducted a prospective, multi-center, non-randomized, controlled trial that enrolled postmenopausal early-stage strongly ER-positive (≥ 50%) and HER2-negative breast cancer patients. All patients were given 4-month NET before surgery. The primary objective was to investigate the 5-year recurrence-free survival (RFS) in patients who had PEPI 0-1 or pathological complete response (pCR) without chemotherapy. Patients who had PEPI 0-1 or pCR were recommended to receive adjuvant endocrine therapy only and patients had PEPI ≥ 2 may receive adjuvant chemotherapy at the discretion of the treating physician. RESULTS: A total of 410 patients were included and 352 patients constituted the per-protocol population. Overall, 9 patients (2.5%) had pCR (ypT0/is ypN0), 128 patients (36.4%) had PEPI = 0, and 56 patients (15.9%) had PEPI = 1. After a median follow-up of 60 months (4-104 months), patients who had PEPI 0-1 or pCR showed an improved 5-year RFS [99.5% (95% CI 98.5-99.9%) for PEPI 0-1 or pCR group vs. 93.7% (95% CI 89.6-97.8%) for PEPI ≥ 2 group, P = 0.028]. No survival difference was detected between patients received adjuvant chemotherapy vs. no chemotherapy among PEPI ≥ 2 cases. CONCLUSION: PEPI 0-1 or pCR may be used to define a group of ER-positive and HER2-negative postmenopausal early breast cancer patients with low relapse risk for whom adjuvant chemotherapy can be safely withheld. Studies on the identification and alternative treatment options for endocrine-resistant tumors are warranted. CLINICAL TRIAL REGISTRATION: NCT01613560.


Asunto(s)
Neoplasias de la Mama , Terapia Neoadyuvante , Protocolos de Quimioterapia Combinada Antineoplásica/efectos adversos , Neoplasias de la Mama/tratamiento farmacológico , Neoplasias de la Mama/genética , Neoplasias de la Mama/patología , Quimioterapia Adyuvante , Femenino , Humanos , Terapia Neoadyuvante/métodos , Recurrencia Local de Neoplasia/tratamiento farmacológico , Pronóstico , Estudios Prospectivos , Receptor ErbB-2/genética
17.
BMC Med Genomics ; 15(1): 176, 2022 08 07.
Artículo en Inglés | MEDLINE | ID: mdl-35934709

RESUMEN

BACKGROUND: Recurrent patellar dislocation is the result of anatomical alignment and imbalance of restraint of bone and soft tissue. We investigate the anatomical characteristics of the knee joint in a family of patients with recurrent patella dislocation, and to screen the possible pathogenic genes in this family by whole exome sequencing in 4 patients and 4 healthy subjects, so as to provide theoretical basis for the pathogenesis of this disease. METHODS: The data related to patella dislocation were measured by imaging data. The peripheral blood DNA of related family members was extracted for the whole exome sequencing, and then the sequencing results were compared with the human database. By filtering out synonymous variants and high-frequency variants in population databases, and then integrating single nucleotide non-synonymous variants of family members, disease-causing genes were found. RESULTS: All patients in this family have different degrees of abnormal knee anatomy, which is closely related to patella dislocation. The sequencing results of patients and normal persons in this patella dislocation family were compared and analyzed, and the data were filtered through multiple biological databases. Find HOXB9 (NM_024017.4:c.404A>G:p.Glu135Gly),COL1A1(NM_000088.3:c.3766G>A:p.Ala1256Thr),GNPAT(NM_014236.3:c1556A>G:p.Asp519Gly),NANS(NM_018946.3:c.204G>C:p.Glu68Asp),SLC26A2(NM_000112.3:c.2065A>T:p.Thr689Ser) are nonsynonymous variants (MISSENSE). Through Sanger sequencing, the identified mutations in HOXB9 and SLC26A2 genes were only present in samples from patients with recurrent patellar dislocation. CONCLUSIONS: The patients with recurrent patellar dislocation had markedly abnormal knee anatomy in this family. HOXB9 gene and SLC26A2 gene were found to be the possible pathogenic genes or related genes for patella dislocation.


Asunto(s)
Luxación de la Rótula , Diagnóstico por Imagen , Proteínas de Homeodominio/genética , Humanos , Articulación de la Rodilla , Mutación , Rótula/patología , Luxación de la Rótula/epidemiología , Luxación de la Rótula/genética , Luxación de la Rótula/patología , Recurrencia
18.
Bioresour Technol ; 359: 127458, 2022 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-35700902

RESUMEN

This study aimed to reveal the potential mechanism of influence exogenous cellulose-degrading bacteria (ECDB) exerted on humus synthesis during the co-composting of corn straw and cattle manure. By measuring the changes in physicochemical factors and bacterial communities, it was revealed that inoculation with ECDB enhanced the driving force of cellulose degradation and humus synthesis. ECDB not only directly participated in cellulose degradation as degrading bacteria, but also changed the bacterial community succession, and increased the abundance of bacterial communities associated with cellulose degradation. The results showed that ECDB stimulated the potential functions and interactions of bacterial communities. Structural equation modeling confirmed that ECDB acted mainly as a bioactivator to promote humus formation in co-composting of corn straw and cattle manure. Taken together, these findings offered new strategies which can be effectively utilized to increase the efficiency and quality of corn straw composting.


Asunto(s)
Compostaje , Animales , Bacterias , Bovinos , Celulosa , Estiércol/microbiología , Suelo , Zea mays
19.
Medicine (Baltimore) ; 101(23): e29075, 2022 Jun 10.
Artículo en Inglés | MEDLINE | ID: mdl-35687768

RESUMEN

BACKGROUND: The purpose of this study was to evaluate the clinical outcomes and complications of displaced proximal humeral fractures treated with proximal humeral internal locking system (PHILOS) plate fixation via a deltoid interfascicular (DI) vs a deltopectoral (DP) approach. METHODS: This prospective case-control study was conducted with patients admitted to our hospital from May 2015 to June 2018 who suffered from unilateral displaced proximal humerus fractures. Patients were treated with PHILOS plate fixation via a DI (DI group) or DP approach (DP group). The clinical outcomes and complication data were collected for comparison between the 2 groups. The patients were followed up at 3, 6, and 12 months; and every 6 months thereafter. The patients' functional recoveries were evaluated according to the normalized Constant-Murley score, range of motion of the shoulder (flexion, abduction, external/internal rotation) and disabilities of the arm, shoulder and hand score. RESULTS: A total of 77 patients, followed for an average of 15 ±â€Š2.2months (range, 12-21), were enrolled (36 in DI group and 41 in DP group) for final analysis. No significant differences in age, sex, affected side, fracture type, injury mechanism or time from injury to operation were found between the 2 groups (all P > .05). The incision length, intra-operative blood loss, and duration of operation in the DI group were significantly less than those in the DP group, respectively (all P < .05). The functional outcomes assessed by the normalized Constant-Murley score and range of motion of flexion and internal rotation in the DI group were superior to those in the DP group at 3 and 6months after the operation (P < .05); however, no significant differences were observed at the 12-month and subsequent follow-ups (all P > .05). There was no significant difference in the range of shoulder external rotation and abduction during the postoperative follow-ups (P > .05). At the last follow-up, the mean disabilities of the arm, shoulder, and hand score was 14.0 (6.6) points in the DI group and 14.4 (6.9) points in the DP group (P = .793). Complications occurred in 1 patient in the DI group and 8 patients in the DP group (P = .049). CONCLUSION: The current study demonstrates that DI approach is a safe and effective alternative for the treatment displaced proximal humerus fractures. The DI approach rather than DP approach was recommended when lateral and posterior exposure of the proximal humerus is required, especially when fixed with PHILOS plate.


Asunto(s)
Fracturas del Hombro , Placas Óseas , Estudios de Casos y Controles , Fijación Interna de Fracturas/efectos adversos , Humanos , Húmero , Fracturas del Hombro/etiología , Fracturas del Hombro/cirugía , Resultado del Tratamiento
20.
Orthop Surg ; 14(6): 1071-1077, 2022 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-35466578

RESUMEN

OBJECTIVE: To review the clinical outcomes of revision total knee arthroplasty (RTKA) with massive proximal tibial bone defects using patient-customized three-dimensional (3D) printed highly porous metaphyseal cones. METHODS: A retrospective study of all patients at our institution who underwent RTKA with the Anderson Orthopaedic Research Institute type III tibial defects using patient-customized 3D-printed highly porous metaphyseal cones was performed from 2016 to 2018. Seven patients were enrolled in this study. General results (age, sex, and body mass index); intraoperative results (interface compatibility and stability, and operating time); and perioperative complications (total blood loss, blood transfusion rate, and deep venous thrombosis) were recorded and analyzed. Clinical improvement and functional evaluation (survivorship of implant, improvement of Hospital for Special Surgery Score and McMaster Universities Osteoarthritis Index, and improvement of range of motion [ROM]), and radiographic improvement and implant evaluation (progressive radiolucent lines or radiographic loosening, and mechanical alignment) were evaluated at 2 weeks, 6 weeks, 3 months, 6 months, 1 year, 2 years, and then annually, postoperatively. RESULTS: The mean age at diagnosis was 68 (61-77) years. The mean follow-up was 25.3 (19-36) months. At the latest follow-up, no aseptic loosening, prosthetic joint infection, or other complications were noted. The mean Hospital for Special Surgery Score increased from 49 (39-63) to 78 (70-83) (P < 0.01), whereas the mean Western Ontario and McMaster Universities Osteoarthritis Index increased from 59 (46-73) to 26 (12-38) (P < 0.01). All patients achieved improved postoperative ROM with the mean flexion angle increasing from 66° (30°-80°) to 93° (80°-100°), and improved mechanical alignment with all hip-knee-ankle (HKA) angles within ±3°. CONCLUSIONS: The patient-customized 3D-printed metaphyseal cone is useful technique for reconstructing massive proximal tibial bone defects, with encouraging clinical and radiological outcomes in RTKA.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Osteoartritis , Humanos , Articulación de la Rodilla/cirugía , Osteoartritis/cirugía , Diseño de Prótesis , Reoperación , Estudios Retrospectivos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...