Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 34
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Clin Oral Investig ; 28(9): 478, 2024 Aug 10.
Artículo en Inglés | MEDLINE | ID: mdl-39122868

RESUMEN

OBJECTIVES: This study aimed to evaluate the dentin bond performance of various resin luting cement (RLC) systems combined with universal adhesives in different luting strategies. MATERIALS AND METHODS: Three self-adhesive resin luting cements (SRLCs) were used with universal adhesives as primers. Twelve specimens per group were prepared to measure shear bond strength (SBS) under distinct luting strategies in etch-&-rinse and self-etch modes. Regarding luting strategies, the bonded specimens were categorized into four groups based on tooth primer application and the curing mode of the SRLC paste: (i) with light irradiation of the tooth primer (wL) + dual-cure mode (DC) of the SRLC paste, (ii) wL + self-cure mode (SC) of the SRLC paste, (iii) without light irradiation of the tooth primer (woL) + DC mode of the SRLC paste, and (iv) woL + SC mode of the SRLC paste. Specimens were also subjected to different storage conditions: 24 h in water (baseline condition) and 10,000 cycles of thermal cycling. RESULTS: Luting strategy, storage condition, and SRLC system type significantly influenced dentin SBS values in both etching modes. Notably, certain SRLCs exhibited significantly higher dentin SBS when the primer was light-irradiated compared with no primer irradiation. CONCLUSION: Most SRLCs demonstrated higher dentin bond strength with light-irradiated primers, suggesting potential enhancement of dentin bond performance via primer light irradiation.


Asunto(s)
Recubrimiento Dental Adhesivo , Análisis del Estrés Dental , Ensayo de Materiales , Cementos de Resina , Resistencia al Corte , Cementos de Resina/química , Recubrimiento Dental Adhesivo/métodos , Recubrimientos Dentinarios/química , Propiedades de Superficie , Técnicas In Vitro , Cementos Dentales/química , Dentina , Humanos
2.
J Esthet Restor Dent ; 2024 Jul 30.
Artículo en Inglés | MEDLINE | ID: mdl-39076148

RESUMEN

OBJECTIVES: To evaluate the color-match with extracted natural teeth of three single-shade universal composites, a group-shade universal composite, and a highly translucent-shade conventional composite. METHODS: Twenty extracted human teeth were divided into light- and dark-shade groups (n = 10, LSG and DSG). A preparation was restored with the 3 single-shade universal composites, OMNICHROMA (OMC), Admira Fusion x-tra U (AFU), and Essentia U (ESU); a highly translucent-shade conventional composite, Tetric EvoCeram T (TEC-T); and two shades of a group-shade universal composite-Filtek Universal Restorative (FUR A1 and A4). Composites were photopolymerized, polished, and stored in water for 24 h. The ΔE00 value between the unprepared and restored surfaces was obtained using a spectrophotometer. Composite placement and measurements were repeated three times per tooth. Color differences were statistically analyzed with the within-between-subjects t-test and repeated-measures analysis of variance (ANOVA), followed by post hoc pairwise comparisons with a Bonferroni adjustment (α = 0.05). RESULTS: There were no statistically significant differences between OMC and FUR (A1 and A4). AFU and ESU showed significantly higher ΔE00 values than OMC and TEC-T (p < 0.05). Single-shade composites exhibited significantly higher ΔE00 values in the DSG than in the LSG except ESU (p < 0.05). None of the composites satisfied the criteria for an acceptable match (ΔE00 >1.8). CONCLUSION: OMC showed the same color matching ability as a group-shade universal composite. A highly translucent-shade conventional composite and OMC exhibited better color matching ability than other single-shade composites. Overall, single-shade universal composites performed better in lighter-shaded teeth. CLINICAL SIGNIFICANCE: Single-shade universal composites have the potential to reduce chair time by eliminating shade selection in cavities with lighter-shade teeth. Highly translucent incisal conventional composites also may be used if the appropriate shade of composite is not available.

3.
J Prosthodont ; 33(3): 281-287, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-37014263

RESUMEN

PURPOSE: This study aimed to assess the fracture resistance of monolithic zirconia-reinforced lithium silicate laminate veneers (LVs) fabricated on various incisal preparation designs. MATERIALS AND METHODS: Sixty maxillary central incisors with various preparation designs were 3D-printed, 15 each, including preparation for: (1) LV with feathered-edge design; (2) LV with butt-joint design; (3) LV with palatal chamfer; and (4) full-coverage crown. Restorations were then designed and manufactured from zirconia-reinforced lithium silicate (ZLS) following the contour of a pre-operation scan. Restorations were bonded to the assigned preparation using resin cement and following the manufacturer's instructions. Specimens were then subjected to 10,000 thermocycles at 5 to 55°C with a dwell time of 30 s. The fracture strength of specimens was then assessed using a universal testing machine at a crosshead speed of 1.0 mm/min. One-way ANOVA and Bonferroni correction multiple comparisons were used to assess the fracture strength differences between the test groups (α = 0.001). Descriptive fractographic analysis of specimens was carried out with scanning electron microscopy images. RESULTS: Complete coverage crown and LV with palatal chamfer design had the highest fracture resistance values (781.4 ± 151.4 and 618.2 ± 112.6 N, respectively). Single crown and LV with palatal chamfer had no significant difference in fracture strength (p > 05). LV with feathered-edge and butt-joint designs provided significantly (p < 05) lower fracture resistance than complete coverage crown and LV with palatal chamfer design. CONCLUSION: The fracture resistance of chairside milled ZLS veneers was significantly influenced by the incisal preparation designs tested. Within the limitation of this study, when excessive occlusal forces are expected, LV with palatal chamfer display is the most conservative method of fabricating an indirect restoration.


Asunto(s)
Cerámica , Porcelana Dental , Porcelana Dental/uso terapéutico , Resistencia Flexional , Litio , Ensayo de Materiales , Análisis del Estrés Dental , Coronas , Circonio/uso terapéutico , Silicatos , Diseño Asistido por Computadora , Diseño de Prótesis Dental
4.
J Esthet Restor Dent ; 35(8): 1286-1292, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37449726

RESUMEN

OBJECTIVE: This study aimed to isolate the relationship between filler size and the surface properties of roughness and gloss before and after toothbrush abrasion for experimental resin-based composites (RBCs) containing uniform spherical fillers. MATERIALS AND METHODS: Five experimental light-cured RBCs with different spherical filler sizes and three commercial RBCs were studied. Forty specimens were polished using silicon carbide papers. Gloss was measured after 0, 90, 180, and 360 min of simulated toothbrushing, and surface roughness was measured before and after 360 min of toothbrushing. Two-way ANOVA/Tukey's multiple comparison tests were used to compare the RBCs, and the correlation between particle size and surface roughness or gloss was also determined. RESULTS: After polishing and toothbrushing, RBCs with smaller fillers exhibited significantly higher gloss and lower surface roughness, and RBCs with larger fillers exhibited lower gloss and higher surface roughness. A significant correlation was found between filler particle size and gloss and surface roughness both before and after toothbrush abrasion. CONCLUSIONS: Gloss of RBCs containing fillers with larger particle sizes was significantly reduced. After toothbrushing abrasion, the surface roughness increased for all RBCs, except those containing the finest-sized fillers. The particle size of the filler is a critical determinant of the surface roughness and gloss of RBCs, after polishing and after toothbrushing. CLINICAL SIGNIFICANCE: Increased surface roughness caused by toothbrush abrasion reduces the gloss of resin-based composites. Resin-based composites containing finer fillers best maintain glossiness after routine tooth brushing.


Asunto(s)
Resinas Compuestas , Materiales Dentales , Tamaño de la Partícula , Ensayo de Materiales , Cepillado Dental , Propiedades de Superficie , Pulido Dental
5.
J Contemp Dent Pract ; 24(11): 859-863, 2023 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-38238273

RESUMEN

AIM: To compare the bond strength of two resin cements to leucite-reinforced ceramics using three different boding agents and evaluate the compatibility of bonding agents. MATERIALS AND METHODS: Twenty extracted sound human molars were sectioned horizontally 2-3 mm above the cementoenamel junction (CEJ). CAD/CAM ceramic blocks for inLab were also sectioned to create 4 mm thick and bonded to the dentin. The adhesive groups assigned were divided into four adhesive groups: Group I: Variolink II dual-cure resin cement and Scotchbond Multi-Purpose Plus adhesive, group II: Multilink Automix dual-cure resin cement and Multilink primers, group III: Multilink Automix and Clearfil SE bond 2 (CSE2) adhesive, group IV: Multilink Automix and CSE2 with light curing after adhesive application. Five specimens of each group were sectioned perpendicular to obtain six microsticks of 1 × 1 mm width from each sample. Microtensile bond strength data were expressed in MPa. Fracture modes (FrMs) analyzed for the surfaces were divided into six patterns. Microtensile bond strength data were statistically analyzed with one-way ANOVA and Tukey post hoc tests (α = 0.05). T-test was performed at the 5% significance level to analyze groups III and IV with and without light curing. RESULTS: Group I showed the highest µTBS average of 13.67 MPa, group IV showed 12.26 MPa, group III showed 12.15 MPa, and group II showed the lowest average of 10.84 MPa. No significant differences were found between the bonding agents. However, the six types of failure modes, although all observed, were characterized by the adhesive system: Type I: adhesive failure of laminated dentin and ceramic; type II: adhesive failure of laminated ceramic; type III: adhesive failure of laminated dentin; type IV: cohesive failure of luting agent; type V: cohesive failure of dentin, and type VI: mixed failure of adhesion and cohesion. As a result, the FrM most commonly observed was the adhesive failure at the luting cement-ceramic block interface. CONCLUSION: The combination of resin cements and bonding agents did not significantly affect the bond strength of CAD/CAM ceramic restorations and dentin. CLINICAL SIGNIFICANCE: Several universal bonding agents are currently available for direct and indirect bonding, and using the same bonding agent for direct and indirect restorations could simplify inventory and benefit routine clinical practice. How to cite this article: Aida N, Koi K, Amaya-Pajares SP, et al. Bond Strength of Two Resin Cements with Leucite-reinforced Ceramic Using Different Bonding Agents. J Contemp Dent Pract 2023;24(11):859-863.


Asunto(s)
Silicatos de Aluminio , Recubrimiento Dental Adhesivo , Cementos de Resina , Humanos , Cementos de Resina/química , Porcelana Dental/química , Propiedades de Superficie , Cerámica/química , Cementos Dentales/química , Ensayo de Materiales , Resistencia a la Tracción , Recubrimientos Dentinarios/química
6.
Dent Clin North Am ; 66(4): 567-590, 2022 10.
Artículo en Inglés | MEDLINE | ID: mdl-36216447

RESUMEN

Although the accuracy of direct digitization of oral structure has been improved, indirect digitization is still required in specific situations such as full-arch scanning. Once accurate images are imported, efficient designing can be achieved by CAD software. Although smile design using a 3-dimensional facial scan better predicts planned restorations, further improvement in virtual articulators is needed for complex cases. Computer-aided manufacturing can be offered in several formats such as chairside, laboratory, or centralized fabrications. The subtractive technique is mainly used for restorations, and many chairside CAM materials are available now, but the additive technique has the potential to save materials and an advantage in fabricating complex geometries. Limited evidence is available in applying CAD/CAM technologies in implant restorations. However, it is used to fabricate custom implant abutments and crowns from various materials such as titanium, zirconia, and PEEK and hybrid crowns using stock titanium base abutments.


Asunto(s)
Tecnología Digital , Titanio , Diseño Asistido por Computadora , Coronas , Diseño de Prótesis Dental , Humanos , Circonio
7.
Clin Case Rep ; 10(3): e05499, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-35280077

RESUMEN

Novel translucent monolithic zirconia has improved optical properties, and it may fulfill patient's esthetic demands and overcome the chipping risk of bilayer metal-ceramic restorations. New zirconia's microstructures allow us to mimic natural teeth.

8.
J Esthet Restor Dent ; 34(1): 15-41, 2022 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-35088935

RESUMEN

OBJECTIVE: To describe the effect of the composites' composition to produce high surface smoothness/gloss using finishers/polishers, and to assess maintained smoothness/gloss under toothbrush abrasion. MATERIALS AND METHODS: PubMed papers published from January 01, 2000 to September 01, 2021 were included, and keywords used were: filler particle size, shape, amount of dental composites; finishing/polishing, gloss/roughness, and toothbrush abrasion of composites. Seventy-five in-vitro studies were included in this literature review. Forty-six articles assessed filler particle size/composition/shape and distribution to obtain high gloss/smoothness on different formulations; and the finishers/polishers effect on these materials. Twenty-nine papers assessed toothbrush abrasion of composites. RESULTS: Suprananofill/nanofill/microfills typically showed the smoothest and glossiest surfaces compared to nanohybrid, microhybrid and hybrid composites. Microfill (0.04-0.07 µm, 71-88 GU); suprananofill (0.001-0.8 µm, 52-92 GU), microhybrids (0.05-0.35 µm, 35-95 GU) and nanohybrids (0.05-0.21 µm, 66-97 GU). Composites with small, spherical particles tend to show smoother, glossier surfaces and more wear resistant compared to resin composites with larger or irregular particles. Several studies showed higher roughness and reduced gloss after toothbrush abrasion. CONCLUSIONS: Within the limitations of this study, suprananofill/nanofill/microfill composites tended to show the smoothest/glossiest surfaces due to smaller particle size. Composites with small, spherical particles tended to show smoother/glossier surfaces. Overall, toothbrush abrasion showed higher surface roughness and reduced gloss. CLINICAL SIGNIFICANCE: Suprananofills/nanofills/microfills had good polishability and polish retention due to their smaller particle size. The effectiveness of a polishing system is material-dependent. In general, Enhance-PoGo, Sof-Lex discs, and Sof-Lex Spiral wheels showed similar level of smoothness.


Asunto(s)
Resinas Compuestas , Pulido Dental , Ensayo de Materiales , Polonia , Propiedades de Superficie
9.
J Oral Sci ; 63(4): 358-360, 2021 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-34497245

RESUMEN

Introducing new technology in the dental school curriculum may face some uphill challenges navigating through university-level bureaucracy, financial ramifications, and influencing the mindset of certain faculty. A dental school that relies heavily on teaching traditional restorative procedures may particularly face many challenges to embrace new technology. The restorative department at a US dental school created a division of computer-aided design and computer-aided manufacturing (CAD/CAM) dentistry to introduce the concept of digital dentistry to dental students and faculty. This article describes methods that were adopted to improve acceptance and increase the productivity of chairside CAD/CAM restorations for both students and faculty at the dental school in US.


Asunto(s)
Curriculum , Facultades de Odontología , Diseño Asistido por Computadora , Odontología , Humanos
10.
J Oral Sci ; 62(4): 458-460, 2020 Sep 26.
Artículo en Inglés | MEDLINE | ID: mdl-32863316

RESUMEN

The purpose of this case report is to describe a minimally invasive technique for non-vital tooth bleaching using traditional Japanese paper, known as washi. Non-vital tooth bleaching with a mixture of sodium perborate and 30% hydrogen peroxide rolled in Japanese paper for a traumatically injured tooth, and in-office vital-tooth bleaching for the upper front six teeth and first premolars, were performed. Five-year follow-up showed satisfactory stability in the bleaching effects and did not show any problems in the traumatically injured tooth. The use of Japanese paper for non-vital tooth bleaching may minimize damage to discolored non-vital teeth.


Asunto(s)
Blanqueamiento de Dientes , Decoloración de Dientes , Diente no Vital , Diente Premolar , Humanos , Peróxido de Hidrógeno , Japón
11.
Restor Dent Endod ; 45(2): e15, 2020 May.
Artículo en Inglés | MEDLINE | ID: mdl-32483533

RESUMEN

This clinical report describes designing and fabricating a single-retainer resin-bonded fixed dental prosthesis with a chair-side computer-aided design/computer-aided manufacturing system. The whole procedure, from tooth extraction to final placement of the prosthesis, was completed in one day, and a single clinic visit. No clinical complications were found at the 2-year follow-up after placement of the restoration, and satisfactory functional and esthetic results were achieved.

12.
Eur J Oral Sci ; 128(4): 354-360, 2020 08.
Artículo en Inglés | MEDLINE | ID: mdl-32395905

RESUMEN

In order to evaluate the influence of 38% silver diamine fluoride (SDF) application on enamel and dentin bond stability of universal adhesives in self-etch mode, a 38% SDF and three universal adhesives were used in this study. Initial shear bond strength (ISBS), fatigue bond strength (FBS), and shear bond strength of survivors (SBSS) to enamel and dentin of universal adhesives in self-etch mode, with and without SDF application, were determined. SDF was applied to the polished enamel or dentin surface for 1 min, water-rinsed and air-dried for comparison with controls. The universal adhesives were applied to the prepared samples and composite resin was bonded using a mold-enclosed method. Enamel bond stability of universal adhesives with SDF (ISBS: 14.7-20.4 MPa; FBS: 5.5-7.4 MPa and SBSS: 14.4-21.5 MPa) was significantly weaker than those without SDF (ISBS: 28.0-29.2 MPa; FBS: 12.1-15.6 MPa and SBSS: 28.4-34.4 MPa). Dentin bond stability with SDF (ISBS: 14.8-20.9 MPa; FBS: 7.1-8.2 MPa and SBSS: 17.3-21.8 MPa) was also significantly weaker than without SDF (ISBS: 19.3-36.1 MPa; FBS: 11.0-13.7 MPa and SBSS: 22.2-34.6 MPa). The results suggest that SDF application on enamel and dentin reduces the bond stability of universal adhesives in self-etch mode.


Asunto(s)
Recubrimiento Dental Adhesivo , Recubrimientos Dentinarios , Cementos Dentales , Esmalte Dental , Dentina , Fluoruros Tópicos , Ensayo de Materiales , Compuestos de Amonio Cuaternario , Cementos de Resina , Resistencia al Corte , Compuestos de Plata
13.
BMC Cancer ; 19(1): 1021, 2019 Oct 29.
Artículo en Inglés | MEDLINE | ID: mdl-31664946

RESUMEN

BACKGROUND: Recent preclinical data suggest that androgen receptor (AR) signaling plays a significant role in subsets of breast cancer. Clinical trials testing AR-targeting therapies in breast cancer have been conducted. Assessment of AR-signal in breast cancer tissue maybe useful for treatment selections. Prostate specific antigen (PSA) is the product of an androgen-responsive gene. Serum PSA (sPSA) can be detected in women by a highly sensitive assay although the concentration is much lower than that observed in males. We investigated if sPSA reflects tumor biology, including AR signaling in breast cancer patients. METHODS: In this study, 132 healthy controls and 144 breast cancer patients were enrolled. sPSA was evaluated by the chemiluminescent enzyme immunoassay (CLEIA) method. Correlations between sPSA and the various clinicopathological factors were analyzed. RESULTS: In post-menopausal state, sPSA detection rate was significantly higher in breast cancer patients compared with controls (27.4% vs 11.3%: p = 0.0090), but not in the whole cohort (29.2% vs 25.8%: p = 0.5265) or pre-menopausal subgroup (37.0% vs 42.6%: p = 0.6231). In post-menopausal breast cancer cases, higher sPSA value was associated with clinic-pathological factors including the expression of AR protein in primary legion. In a correlation analysis of quantitative data limited to post-menopausal metastatic breast cancer (MBC), sPSA was positively, albeit weakly correlated with clinic-pathological features including serum testosterone levels and AR positivity. CONCLUSIONS: Our data suggest that sPSA may reflect tumor biological properties including AR activity in post-menopausal breast cancer.


Asunto(s)
Neoplasias de la Mama/sangre , Neoplasias de la Mama/patología , Calicreínas/sangre , Antígeno Prostático Específico/sangre , Adulto , Anciano , Antineoplásicos Hormonales/uso terapéutico , Biomarcadores de Tumor/sangre , Neoplasias de la Mama/tratamiento farmacológico , Estudios de Cohortes , Femenino , Humanos , Técnicas para Inmunoenzimas/métodos , Persona de Mediana Edad , Posmenopausia/sangre , Receptores Androgénicos/metabolismo , Testosterona/sangre
14.
Quintessence Int ; 50(7): 534-538, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31187101

RESUMEN

The clinical report describes a three-dimensional (3D) printed coping for intraoral evaluation before milling final anterior restorations. The use of printed copings allows restorations for complex and esthetically important restorations to be thoroughly tested at relatively low cost without introducing large delays into the fabrication process.


Asunto(s)
Diseño Asistido por Computadora , Diseño de Prótesis Dental , Adaptación Psicológica , Impresión Tridimensional
15.
J Mech Behav Biomed Mater ; 87: 111-118, 2018 11.
Artículo en Inglés | MEDLINE | ID: mdl-30056308

RESUMEN

OBJECTIVES: The purpose of this study was to investigate the simulated cuspal deflection and flexural properties of high viscosity bulk-fill and conventional resin composites. METHODS: Seven high viscosity bulk-fill resin composites and eight conventional resin composites were used. Aluminum blocks (10 mm x 8 mm x 15 mm) with a mesio-occlusal-distal (MOD) cavity [4 (W) mm x 8 (L) mm x 4 (D) mm] were prepared and randomly divided into groups for different measurement techniques [micrometer vs CSLM] and further subdivided according to type of resin composite (high viscosity bulk-fill vs conventional resin composite). The simulated cuspal deflection resulting from the polymerization of resin composite bonded to a precisely machined MOD cavity within an aluminum block was measured with either a novel highly accurate submicron digimatic micrometer (MDH-25 M, Mitsutoyo, Tokyo, Japan) or a confocal laser scanning microscope (CLSM, VK-9710, Keyence, Tokyo, Japan) cuspal measurement method. In addition, flexural properties of tested resin composites were measured to investigate the relationship between simulated cuspal deflection and flexural properties. Scanning electron microscopy observation of tested resin composites was also conducted. RESULTS: The simulated cuspal deflection of high viscosity bulk-fill resin composites was similar to that of conventional resin composites, regardless of measurement method. There were no statistically significant differences (p > 0.05) between the micrometer and CLSM cuspal measurement methods. There were statistically significant differences (p < 0.05) in flexural strength and elastic modulus depending on the material, regardless of the type of resin composite. Pearson correlation analysis did not show any statistically significant (p < 0.05) relationship between flexural properties and cuspal deflection. CONCLUSIONS: The results of this study indicate that high viscosity bulk-fill resin composites show similar cuspal deflection with bulk-filling techniques, to those shown by conventional resin composites with incremental filling techniques. Simulated cuspal deflection can be measured using either a micrometer or CLSM, but this experiment failed to show any relationship between the flexural properties and simulated cuspal deflection of resin composites. SIGNIFICANCE: High viscosity bulk-fill resin composites produce the same level of cuspal deflection as a conventional incrementally filled resin composite.


Asunto(s)
Resinas Compuestas , Resistencia Flexional , Ensayo de Materiales/instrumentación , Viscosidad
16.
Restor Dent Endod ; 43(1): e9, 2018 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-29487839

RESUMEN

The objective of this case report is to introduce a simple technique for simultaneously taking a closed-mouth impression and functionally generated path (FGP) for a full coverage crown restoration. A monolithic zirconia crown was the restoration of choice. An alginate impression of the abutment tooth was taken to fabricate a custom-made closed-mouth impression tray covering the abutment tooth and the adjacent teeth. The tray had an FGP table and an abutment tray in cameo and intaglio surfaces, respectively. The impression was taken with silicone impression material after adjusting the abutment tray and inscribing the FGP using self-curing acrylic resins. Plaster casts were made from the impression, and a zirconia crown was fabricated. The crown was cemented to the abutment tooth with minimal adjustments. This simple technique resulted in a well-fitting crown that accounted for mandibular movements. Using the custom closed-mouth impression tray incorporating an FGP table simultaneously aids in fabricating an accurately fitting restoration that incorporates harmonious mandibular movements using a single impression capture.

17.
J Oral Sci ; 60(1): 29-36, 2018 Mar 24.
Artículo en Inglés | MEDLINE | ID: mdl-29375099

RESUMEN

This study evaluated the simulated localized wear of resin luting cements for universal adhesive systems using different curing modes. Five resin luting cements for universal adhesive systems were evaluated and subsequently subjected to wear challenge in a Leinfelder-Suzuki wear simulation device. Overall, 20 specimens from each resin luting cement were photo-cured for 40 s (dual-cure group), and 20 specimens of each material were not photo-cured (chemical-cure group). Simulated localized wear was generated using a stainless steel ball-bearing antagonist in water slurry of polymethylmethacrylate beads. In addition, scanning electron microscopy (SEM) observations of resin luting cements and wear facets were conducted. Significant differences in simulated wear and SEM observations of wear facets were evident among the materials in the dual- and chemical-cure groups. The simulated wear and SEM observations of wear facets of G-CEM LinkForce and Panavia V5 were not influenced by the curing mode. SEM observations of resin luting cements were material dependent. In most cases, dual curing appears to ensure greater wear resistance of resin luting cements than chemical curing alone. The wear resistance of some resin luting cements appears to be material dependent and is not influenced by the curing mode.


Asunto(s)
Adhesivos , Cementos Dentales , Curación por Luz de Adhesivos Dentales , Ensayo de Materiales , Microscopía Electrónica de Rastreo , Propiedades de Superficie
18.
Eur J Oral Sci ; 126(2): 135-145, 2018 04.
Artículo en Inglés | MEDLINE | ID: mdl-29344991

RESUMEN

The relationship between enamel bond fatigue durability and surface free-energy characteristics with universal adhesives was investigated. The initial shear bond strengths and shear fatigue strengths of five universal adhesives to enamel were determined with and without phosphoric acid pre-etching. The surface free-energy characteristics of adhesive-treated enamel with and without pre-etching were also determined. The initial shear bond strength and shear fatigue strength of universal adhesive to pre-etched enamel were higher than those to ground enamel. The initial shear bond strength and shear fatigue strength of universal adhesive to pre-etched enamel were material dependent, unlike those to ground enamel. The surface free-energy of the solid (γS ) and the hydrogen-bonding force (γSh) of universal adhesive-treated enamel were different depending on the adhesive, regardless of the presence or absence of pre-etching. The bond fatigue durability of universal adhesives was higher to pre-etched enamel than to ground enamel. In addition, the bond fatigue durability to pre-etched enamel was material dependent, unlike that to ground enamel. The surface free-energy characteristics of universal adhesive-treated enamel were influenced by the adhesive type, regardless of the presence or absence of pre-etching. The surface free-energy characteristics of universal adhesive-treated enamel were related to the results of the bond fatigue durability.


Asunto(s)
Recubrimiento Dental Adhesivo , Análisis del Estrés Dental , Recubrimientos Dentinarios , Resistencia al Corte , Grabado Ácido Dental , Ensayo de Materiales , Ácidos Fosfóricos , Propiedades de Superficie
19.
J Mech Behav Biomed Mater ; 77: 501-509, 2018 01.
Artículo en Inglés | MEDLINE | ID: mdl-29040961

RESUMEN

OBJECTIVES: The aim of this study was to determine the effect of double-layer application of universal adhesives on the bond quality and compare to other adhesive systems. METHODS: Two universal adhesives used were in this study: Scotchbond Universal (SU), [3M ESPE] and Prime & Bond elect (PE), [Dentsply Caulk]. The conventional single-step self-etch adhesives G-ӕnial Bond (GB), [GC Corporation.] and BeautiBond (BB), [Shofu Inc.], and a two-step self-etch adhesive, Optibond XTR (OX), [Kerr Corporation], were used as comparison adhesives. Shear bond strengths (SBS) and shear fatigue strengths (SFS) to human enamel and dentin were measured in single application mode and double application mode. For each test condition, 15 specimens were prepared for SBS testing and 30 specimens for SFS testing. RESULTS: Enamel and dentin SBS of the universal adhesives in the double application mode were significantly higher than those of the single application mode. In addition, the universal adhesives in the double application mode had significantly higher dentin SFS values than those of the single application mode. The two-step self-etch adhesive OX tended to have lower bond strengths in the double application mode, regardless of the test method or adherent substrate. CONCLUSION: The double application mode is effective in enhancing SBS and SFS of universal adhesives, but not conventional two-step self-etch adhesives. SIGNIFICANCE: These results suggest that, although the double application mode may enhance the bonding quality of a universal adhesive, it may be counter-productive for two-step self-etch adhesives in clinical use.


Asunto(s)
Bisfenol A Glicidil Metacrilato/química , Resinas Compuestas/química , Cementos Dentales/química , Diente Molar/química , Ácidos Polimetacrílicos/química , Cementos de Resina/química , Análisis de Varianza , Fenómenos Biomecánicos , Recubrimiento Dental Adhesivo/métodos , Esmalte Dental/química , Materiales Dentales/química , Fracaso de la Restauración Dental , Análisis del Estrés Dental , Dentina/química , Recubrimientos Dentinarios/química , Humanos , Ensayo de Materiales , Microscopía Electrónica de Rastreo , Resistencia al Corte
20.
Eur J Oral Sci ; 125(3): 215-222, 2017 06.
Artículo en Inglés | MEDLINE | ID: mdl-28452076

RESUMEN

This aim of this study was to compare universal adhesives and two-step self-etch adhesives in terms of dentin bond fatigue durability in self-etch mode. Three universal adhesives - Clearfil Universal, G-Premio Bond, and Scotchbond Universal Adhesive - and three-two-step self-etch adhesives - Clearfil SE Bond, Clearfil SE Bond 2, and OptiBond XTR - were used. The initial shear bond strength and shear fatigue strength of resin composite bonded to adhesive on dentin in self-etch mode were determined. Scanning electron microscopy observations of fracture surfaces after bond strength tests were also made. The initial shear bond strength of universal adhesives was material dependent, unlike that of two-step self-etch adhesives. The shear fatigue strength of Scotchbond Universal Adhesive was not significantly different from that of two-step self-etch adhesives, unlike the other universal adhesives. The shear fatigue strength of universal adhesives differed depending on the type of adhesive, unlike those of two-step self-etch adhesives. The results of this study encourage the continued use of two-step self-etch adhesive over some universal adhesives but suggest that changes to the composition of universal adhesives may lead to a dentin bond fatigue durability similar to that of two-step self-etch adhesives.


Asunto(s)
Recubrimiento Dental Adhesivo/métodos , Cementos Dentales/uso terapéutico , Recubrimiento Dental Adhesivo/efectos adversos , Análisis del Estrés Dental , Humanos , Cementos de Resina/uso terapéutico
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...