Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
J Thorac Oncol ; 19(9): 1272-1283, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38762120

RESUMEN

INTRODUCTION: Electronic nose (E-nose) technology has reported excellent sensitivity and specificity in the setting of lung cancer screening. However, the performance of E-nose specifically for early-stage tumors remains unclear. Therefore, the aim of our study was to assess the diagnostic performance of E-nose technology in clinical stage I lung cancer. METHODS: This phase IIc trial (NCT04734145) included patients diagnosed with a single greater than or equal to 50% solid stage I nodule. Exhalates were prospectively collected from January 2020 to August 2023. Blinded bioengineers analyzed the exhalates, using E-nose technology to determine the probability of malignancy. Patients were stratified into three risk groups (low-risk, [<0.2]; moderate-risk, [≥0.2-0.7]; high-risk, [≥0.7]). The primary outcome was the diagnostic performance of E-nose versus histopathology (accuracy and F1 score). The secondary outcome was the clinical performance of the E-nose versus clinicoradiological prediction models. RESULTS: Based on the predefined cutoff (<0.20), E-nose agreed with histopathologic results in 86% of cases, achieving an F1 score of 92.5%, based on 86 true positives, two false negatives, and 12 false positives (n = 100). E-nose would refer fewer patients with malignant nodules to observation (low-risk: 2 versus 9 and 11, respectively; p = 0.028 and p = 0.011) than would the Swensen and Brock models and more patients with malignant nodules to treatment without biopsy (high-risk: 27 versus 19 and 6, respectively; p = 0.057 and p < 0.001). CONCLUSIONS: In the setting of clinical stage I lung cancer, E-nose agrees well with histopathology. Accordingly, E-nose technology can be used in addition to imaging or as part of a "multiomics" platform.


Asunto(s)
Nariz Electrónica , Neoplasias Pulmonares , Estadificación de Neoplasias , Humanos , Neoplasias Pulmonares/patología , Masculino , Femenino , Persona de Mediana Edad , Anciano , Estudios Prospectivos
2.
JCO Oncol Pract ; 18(1): e219-e224, 2022 01.
Artículo en Inglés | MEDLINE | ID: mdl-34242066

RESUMEN

PURPOSE: The aim of this quality improvement intervention was to evaluate the safety and cost savings of presurgical testing (PST) guidelines for patients undergoing hysterectomy for endometrial pathology in the ambulatory setting. METHODS: Evidence-based presurgical testing (PST) guidelines were developed by a multidisciplinary team. These guidelines were implemented on the gynecologic surgery service of a comprehensive cancer center in January 2016. All patients with a diagnosis of endometrial pathology who underwent ambulatory surgery during the specified time periods were included in this analysis. A pre-post analysis was performed (preperiod, July 2014-December 2015; postperiod, July 2016-December 2017). Rates of completed presurgical tests and perioperative adverse events were compared between time periods. Cost savings related to the reduction in PST were calculated using the direct cost of testing and reported in percentage cost reduction. RESULTS: A total of 749 hysterectomies were completed in the preperiod and 775 in the postperiod. After implementation of PST guidelines, complete blood counts, coagulation testing, comprehensive metabolic panels, chest x-rays, and electrocardiograms were reduced by 13.4%, 78.1%, 36.8%, 39.0%, and 15.5%, respectively (all P < .001). Rates of perioperative cardiopulmonary adverse events (0% v 0%) and hematologic adverse events (3.3% v 2.0%; P = .10) were stable between time periods. There were no deaths within 90 days of surgery. There was a 41.4% reduction in direct costs related to PST in the postperiod. CONCLUSION: The use of evidence-based PST guidelines for patients with endometrial pathology undergoing hysterectomy in the ambulatory setting is safe and cost-effective. A multidisciplinary approach is essential for successful development and implementation.


Asunto(s)
Procedimientos Quirúrgicos Ambulatorios , Neoplasias Endometriales , Ahorro de Costo , Análisis Costo-Beneficio , Neoplasias Endometriales/diagnóstico , Neoplasias Endometriales/cirugía , Femenino , Humanos , Mejoramiento de la Calidad
3.
Trends Anaesth Crit Care ; 46: 33-41, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-38741664

RESUMEN

Cancer in patients with obesity has become increasingly common throughout much of the world. Based on our experiences in a specialized cancer center, we have developed a set of standards and expectations that should streamline the surgical journey for this patient population. These recommendations should inform the perioperative management of oncology patients with obesity and help raise awareness of this critical and under-discussed topic.

4.
J Air Waste Manag Assoc ; 66(10): 959-70, 2016 10.
Artículo en Inglés | MEDLINE | ID: mdl-27192142

RESUMEN

UNLABELLED: From June 2013 to March 2015, in total 41 passive sampler deployments of 2 wk duration each were conducted at 17 sites in South Philadelphia, PA, with results for benzene discussed here. Complementary time-resolved measurements with lower cost prototype fenceline sensors and an open-path ultraviolet differential optical absorption spectrometer were also conducted. Minimum passive sampler benzene concentrations for each sampling period ranged from 0.08 ppbv to 0.65 ppbv, with a mean of 0.25 ppbv, and were negatively correlated with ambient temperature (-0.01 ppbv/°C, R(2) = 0.68). Co-deployed duplicate passive sampler pairs (N = 609) demonstrated good precision with an average and maximum percent difference of 1.5% and 34%, respectively. A group of passive samplers located within 50 m of a refinery fenceline had a study mean benzene concentration of 1.22 ppbv, whereas a group of samplers located in communities >1 km distant from facilities had a mean of 0.29 ppbv. The difference in the means of these groups was statistically significant at the 95% confidence level (p < 0.001). A decreasing gradient in benzene concentrations moving away from the facilities was observed, as was a significant period-to-period variation. The highest recorded 2-wk average benzene concentration for the fenceline group was 3.11 ppbv. During this period, time-resolved data from the prototype sensors and the open-path spectrometer detected a benzene signal from the west on one day in particular, with the highest 5-min path-averaged benzene concentration measured at 24 ppbv. IMPLICATIONS: Using a variation of EPA's passive sampler refinery fenceline monitoring method, coupled with time-resolved measurements, a multiyear study in South Philadelphia informed benzene concentrations near facilities and in communities. The combination of measurement strategies can assist facilities in identification and mitigation of emissions from fugitive sources and improve information on air quality complex air sheds.


Asunto(s)
Contaminantes Atmosféricos/análisis , Benceno/análisis , Monitoreo del Ambiente , Philadelphia , Estaciones del Año , Tiempo (Meteorología)
5.
Artículo en Inglés | MEDLINE | ID: mdl-32636605

RESUMEN

From June 2013 to March 2015, in total 41 passive sampler deployments of 2 wk duration each were conducted at 17 sites in South Philadelphia, PA, with results for benzene discussed here. Complementary time-resolved measurements with lower cost prototype fenceline sensors and an open-path ultraviolet differential optical absorption spectrometer were also conducted. Minimum passive sampler benzene concentrations for each sampling period ranged from 0.08 ppbv to 0.65 ppbv, with a mean of 0.25 ppbv, and were negatively correlated with ambient temperature (-0.01 ppbv/°C, R2 = 0.68). Co-deployed duplicate passive sampler pairs (N = 609) demonstrated good precision with an average and maximum percent difference of 1.5% and 34%, respectively. A group of passive samplers located within 50 m of a refinery fenceline had a study mean benzene concentration of 1.22 ppbv, whereas a group of samplers located in communities >1 km distant from facilities had a mean of 0.29 ppbv. The difference in the means of these groups was statistically significant at the 95% confidence level (p < 0.001). A decreasing gradient in benzene concentrations moving away from the facilities was observed, as was a significant period-to-period variation. The highest recorded 2-wk average benzene concentration for the fenceline group was 3.11 ppbv. During this period, time-resolved data from the prototype sensors and the open-path spectrometer detected a benzene signal from the west on one day in particular, with the highest 5-min path-averaged benzene concentration measured at 24 ppbv. IMPLICATIONS: Using a variation of EPA's passive sampler refinery fenceline monitoring method, coupled with time-resolved measurements, a multiyear study in South Philadelphia informed benzene concentrations near facilities and in communities. The combination of measurement strategies can assist facilities in identification and mitigation of emissions from fugitive sources and improve information on air quality complex air sheds.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...