Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 32
Filtrar
2.
J Comput Assist Tomogr ; 48(1): 12-18, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-37551163

RESUMEN

PURPOSE: The aim of this study was to formally investigate the apparent variation in lesion size of hepatic metastatic lesions from colorectal cancer on hepatobiliary phase (HBP) and dual contrast images of magnetic resonance imaging performed with both hepatobiliary and extracellular contrast agents. METHODS: Patients with known colorectal carcinoma who had undergone dual contrast liver magnetic resonance imaging were identified in our institutional database. Metastatic lesions were measured semiautomatically on both HBP and dual contrast images with a custom software tool that automatically identifies the lesion edge and thereby the lesion diameter. Lesion measurements from both sets of images were compared with a Student t test and Bland-Altman analysis. Lesions were also measured on both HBP and dual contrast images by 2 fellowship-trained abdominal radiologists. Measurements from the software and radiologists were compared with a Student t test and Bland-Altman analysis; interreader agreement was evaluated with the intraclass correlation coefficient. RESULTS: A total of 70 liver lesions in 39 patients was identified. Software-based measurements were significantly larger on HBP than dual contrast images ( P < 0.001), with a mean lesion size of 10.9 ± 4.2 mm for HBP and 10.5 ± 4.2 mm for dual contrast measurements. Radiologist-based measurements showed a similar trend, with HBP measurements being significantly larger than dual contrast measurements ( P < 0.001). Bland-Altman analysis indicated a mean bias ± 2 SD of +0.4 ± 1.6 mm for software-based measurements and +0.9 ± 2.9 mm and +0.7 ± 2.1 mm for readers 1 and 2, respectively. The intraclass correlation coefficient for interreader agreement was 0.9. CONCLUSIONS: Both software-based and radiologist-based measurements of colorectal cancer liver metastases are significantly larger on HBP than dual contrast images. Based on these findings, we recommend that longitudinal assessment be performed consistently on either HBP or dual contrast phases to avoid introduction of avoidable variability.


Asunto(s)
Neoplasias Colorrectales , Neoplasias Hepáticas , Humanos , Medios de Contraste , Sensibilidad y Especificidad , Estudios Retrospectivos , Hígado/diagnóstico por imagen , Hígado/patología , Neoplasias Hepáticas/patología , Imagen por Resonancia Magnética/métodos , Neoplasias Colorrectales/diagnóstico por imagen , Neoplasias Colorrectales/patología , Gadolinio DTPA
3.
Sci Rep ; 13(1): 21034, 2023 11 29.
Artículo en Inglés | MEDLINE | ID: mdl-38030716

RESUMEN

Current risk scores using clinical risk factors for predicting ischemic heart disease (IHD) events-the leading cause of global mortality-have known limitations and may be improved by imaging biomarkers. While body composition (BC) imaging biomarkers derived from abdominopelvic computed tomography (CT) correlate with IHD risk, they are impractical to measure manually. Here, in a retrospective cohort of 8139 contrast-enhanced abdominopelvic CT examinations undergoing up to 5 years of follow-up, we developed multimodal opportunistic risk assessment models for IHD by automatically extracting BC features from abdominal CT images and integrating these with features from each patient's electronic medical record (EMR). Our predictive methods match and, in some cases, outperform clinical risk scores currently used in IHD risk assessment. We provide clinical interpretability of our model using a new method of determining tissue-level contributions from CT along with weightings of EMR features contributing to IHD risk. We conclude that such a multimodal approach, which automatically integrates BC biomarkers and EMR data, can enhance IHD risk assessment and aid primary prevention efforts for IHD. To further promote research, we release the Opportunistic L3 Ischemic heart disease (OL3I) dataset, the first public multimodal dataset for opportunistic CT prediction of IHD.


Asunto(s)
Inteligencia Artificial , Isquemia Miocárdica , Humanos , Estudios Retrospectivos , Isquemia Miocárdica/diagnóstico por imagen , Isquemia Miocárdica/etiología , Tomografía Computarizada por Rayos X/efectos adversos , Factores de Riesgo , Medición de Riesgo , Biomarcadores , Registros Médicos
5.
Cancers (Basel) ; 15(9)2023 Apr 27.
Artículo en Inglés | MEDLINE | ID: mdl-37173966

RESUMEN

Scientific understanding of how the immune microenvironment interacts with renal cell carcinoma (RCC) has substantially increased over the last decade as a result of research investigations and applying immunotherapies, which modulate how the immune system targets and eliminates RCC tumor cells. Clinically, immune checkpoint inhibitor therapy (ICI) has revolutionized the treatment of advanced clear cell RCC because of improved outcomes compared to targeted molecular therapies. From an immunologic perspective, RCC is particularly interesting because tumors are known to be highly inflamed, but the mechanisms underlying the inflammation of the tumor immune microenvironment are atypical and not well described. While technological advances in gene sequencing and cellular imaging have enabled precise characterization of RCC immune cell phenotypes, multiple theories have been suggested regarding the functional significance of immune infiltration in RCC progression. The purpose of this review is to describe the general concepts of the anti-tumor immune response and to provide a detailed summary of the current understanding of the immune response to RCC tumor development and progression. This article describes immune cell phenotypes that have been reported in the RCC microenvironment and discusses the application of RCC immunophenotyping to predict response to ICI therapy and patient survival.

6.
Abdom Radiol (NY) ; 48(6): 2091-2101, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-36947205

RESUMEN

OBJECTIVE: To evaluate the prevalence of angular interface and the "drooping" sign in exophytic renal angiomyolipomas (AMLs) and the diagnostic performance in differentiating exophytic lipid-poor AMLs from other solid renal masses. METHODS: This IRB-approved, two-center study included 185 patients with 188 exophytic solid renal masses < 4 cm with histopathology and pre-operative CT within 30 days of surgical resection or biopsy. Images were reviewed for the presence of angular interface and the "drooping" sign qualitatively by three readers blinded to the final diagnosis, with majority rules applied. Both features were assessed quantitatively by cohort creators (who are not readers) independently. Free-marginal kappa was used to assess inter-reader agreement and agreement between two methods assessing each feature. Fisher's exact test, Mann-Whitney test, and multivariable logistic regression with two-tailed p < 0.05 were used to determine statistical significance. Diagnostic performance was assessed. RESULTS: Ninety-four patients had 96 AMLs, and 91 patients had 92 non-AMLs. Seventy-four (77%) of AMLs were lipid-poor based on quantitative assessment on CT. The presence of angular interface and the "drooping" sign by both qualitative and quantitative assessment were statistically significantly associated with AMLs (39% (qualitative) and 45% (quantitative) vs 15% (qualitative) and 13% (quantitative), and 48% (qualitative) and 43% (quantitative) vs 4% (qualitative) and 1% (quantitative), respectively, all p < 0.001) in univariable analysis. In multivariable analysis, only the "drooping" sign in either qualitative or quantitative assessment was a statistically significant predictor of AMLs (both p < 0.001). Inter-reader agreement for the "drooping" sign was moderate (k = 0.55) and for angular interface was fair (k = 0.33). Agreement between the two methods of assessing the "drooping" sign was substantial (k = 0.84) and of assessing the angular interface was moderate (k = 0.59). The "drooping" sign both qualitatively and quantitatively, alone or in combination of angular interface, had very high specificity (96-100%) and positive predictive value (PPV) (89-100%), moderate negative predictive value (62-68%), but limited sensitivity (23-49%) for lipid-poor AMLs. CONCLUSION: The "drooping" sign by both qualitative and quantitative assessment is highly specific for lipid-rich and lipid-poor AMLs. This feature alone or in combination with angular interface can aid in CT diagnosis of lipid-poor AMLs with very high specificity and PPV.


Asunto(s)
Angiomiolipoma , Carcinoma de Células Renales , Neoplasias Renales , Humanos , Neoplasias Renales/diagnóstico por imagen , Neoplasias Renales/patología , Angiomiolipoma/diagnóstico por imagen , Angiomiolipoma/patología , Carcinoma de Células Renales/patología , Sensibilidad y Especificidad , Diagnóstico Diferencial , Tomografía Computarizada por Rayos X/métodos , Lípidos , Estudios Retrospectivos
7.
Abdom Radiol (NY) ; 48(2): 642-648, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-36370180

RESUMEN

PURPOSE: To assess the performance of a machine learning model trained with contrast-enhanced CT-based radiomics features in distinguishing benign from malignant solid renal masses and to compare model performance with three abdominal radiologists. METHODS: Patients who underwent intra-operative ultrasound during a partial nephrectomy were identified within our institutional database, and those who had pre-operative contrast-enhanced CT examinations were selected. The renal masses were segmented from the CT images and radiomics features were derived from the segmentations. The pathology of each mass was identified; masses were labeled as either benign [oncocytoma or angiomyolipoma (AML)] or malignant [clear cell, papillary, or chromophobe renal cell carcinoma (RCC)] depending on the pathology. The data were parsed into a 70/30 train/test split and a random forest machine learning model was developed to distinguish benign from malignant lesions. Three radiologists assessed the cohort of masses and labeled cases as benign or malignant. RESULTS: 148 masses were identified from the cohort, including 50 benign lesions (23 AMLs, 27 oncocytomas) and 98 malignant lesions (23 clear cell RCC, 44 papillary RCC, and 31 chromophobe RCCs). The machine learning algorithm yielded an overall accuracy of 0.82 for distinguishing benign from malignant lesions, with an area under the receiver operating curve of 0.80. In comparison, the three radiologists had significantly lower accuracies (p = 0.02) ranging from 0.67 to 0.75. CONCLUSION: A machine learning model trained with CT-based radiomics features can provide superior accuracy for distinguishing benign from malignant solid renal masses compared to abdominal radiologists.


Asunto(s)
Adenoma Oxifílico , Carcinoma de Células Renales , Neoplasias Renales , Humanos , Carcinoma de Células Renales/diagnóstico por imagen , Carcinoma de Células Renales/patología , Diagnóstico Diferencial , Estudios Retrospectivos , Neoplasias Renales/diagnóstico por imagen , Neoplasias Renales/patología , Aprendizaje Automático , Radiólogos , Adenoma Oxifílico/patología , Tomografía Computarizada por Rayos X , Diferenciación Celular
8.
Abdom Radiol (NY) ; 47(8): 2896-2904, 2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-35723716

RESUMEN

BACKGROUND: Solid renal masses are often indeterminate for benignity versus malignancy on magnetic resonance imaging. Such masses are typically evaluated with either percutaneous biopsy or surgical resection. Percutaneous biopsy can be non-diagnostic and some surgically resected lesions are inadvertently benign. PURPOSE: To assess the performance of ten machine learning (ML) algorithms trained with MRI-based radiomics features in distinguishing benign from malignant solid renal masses. METHODS: Patients with solid renal masses identified on pre-intervention MRI were curated from our institutional database. Masses with a definitive diagnosis via imaging (for angiomyolipomas) or via biopsy or surgical resection (for oncocytomas or renal cell carcinomas) were selected. Each mass was segmented for both T2- and post-contrast T1-weighted images. Radiomics features were derived from the segmented masses for each imaging sequence. Ten ML algorithms were trained with the radiomics features gleaned from each MR sequence, as well as the combination of MR sequences. RESULTS: In total, 182 renal masses in 160 patients were included in the study. The support vector machine algorithm trained on radiomics features from T2-weighted images performed superiorly, with an accuracy of 0.80 and an area under the curve (AUC) of 0.79. Linear discriminant analysis (accuracy = 0.84 and AUC = 0.77) and logistic regression (accuracy = 0.78 and AUC = 0.78) algorithms trained on T2-based radiomics features performed similarly. ML algorithms trained on radiomics features from post-contrast T1-weighted images or the combination of radiomics features from T2- and post-contrast T1-weighted images yielded lower performance. CONCLUSION: Machine learning models trained with radiomics features derived from T2-weighted images can provide high accuracy for distinguishing benign from malignant solid renal masses. CLINICAL IMPACT: Machine learning models derived from MRI-based radiomics features may improve the clinical management of solid renal masses and have the potential to reduce the frequency with which benign solid renal masses are biopsied or surgically resected.


Asunto(s)
Carcinoma de Células Renales , Neoplasias Renales , Carcinoma de Células Renales/diagnóstico por imagen , Humanos , Neoplasias Renales/diagnóstico por imagen , Aprendizaje Automático , Imagen por Resonancia Magnética/métodos , Estudios Retrospectivos
9.
Eur Radiol ; 32(8): 5669-5678, 2022 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-35175379

RESUMEN

OBJECTIVES: 4D flow MRI allows for a comprehensive assessment of intracardiac blood flow, useful for assessing cardiovascular diseases, but post-processing requires time-consuming ventricular segmentation throughout the cardiac cycle and is prone to subjective errors. Here, we evaluate the use of automatic left and right ventricular (LV and RV) segmentation based on deep learning (DL) network that operates on short-axis cine bSSFP images. METHODS: A previously published DL network was fine-tuned via retraining on a local database of 106 subjects scanned at our institution. In 26 test subjects, the ventricles were segmented automatically by the network and manually by 3 human observers on bSSFP MRI. The bSSFP images were then registered to the corresponding 4D flow images to apply the segmentation to 4D flow velocity data. Dice coefficients and the relative deviation between measurements (automatic vs. manual and interobserver manual) of various hemodynamic parameters were assessed. RESULTS: The automated segmentation resulted in similar Dice scores (LV: 0.92, RV: 0.86) and lower relative deviations from manual segmentation in left ventricular (LV) average kinetic energy (KE) (8%) and RV KE (15%) than the Dice scores (LV: 0.91, RV: 0.87) and relative deviations between manual segmentation observers (LV KE: 11%, p = 0.01; RV KE: 19%, p = 0.03). CONCLUSIONS: The automated post-processing method using deep learning resulted in hemodynamic measurements that differ from a manual observer's measurements equally or less than the variation between manual observers. This approach can be used to decrease post-processing time on intraventricular 4D flow data and mitigate interobserver variability. KEY POINTS: • Our proposed method allows for fully automated post-processing of intraventricular 4D flow MRI data. • Our method resulted in hemodynamic measurements that matched those derived from manual segmentation equally as well as interobserver variability. • Our method can be used to greatly accelerate intraventricular 4D flow post-processing and improve interobserver repeatability.


Asunto(s)
Aprendizaje Profundo , Corazón , Ventrículos Cardíacos/diagnóstico por imagen , Humanos , Imagen por Resonancia Magnética , Imagen por Resonancia Cinemagnética/métodos , Variaciones Dependientes del Observador
10.
Abdom Radiol (NY) ; 47(3): 1124-1132, 2022 03.
Artículo en Inglés | MEDLINE | ID: mdl-35080631

RESUMEN

PURPOSE: Simple renal cysts are common benign lesions that arise from the renal parenchyma. Cyst growth can lead to confusion as well as concern from patients and referring providers about the need for imaging follow-up or additional evaluation. The purpose of this study was to evaluate the natural history of simple renal cysts and determine the best metric to characterize cyst evolution. METHODS: 222 simple renal cysts in 182 adults (age = 58.4 ± 6.0 years) were longitudinally evaluated on non-contrast CT examinations over a mean interval of 7.5 ± 2.8 years. Axial long axis, surface area, and volume were evaluated at baseline and follow-up CT examinations. Absolute and percent annualized growth rates were computed between CT studies for each parameter. RESULTS: At baseline CT examinations, mean (± SD) axial long axis, surface area, and volume measurements were 2.5 ± 1.7 cm, 2.5 ± 4.5 cm2, and 17.6 ± 52.5 ml, respectively. On follow-up examinations, measurements were 3.4 ± 2.0 cm, 4.2 ± 5.9 cm2, and 34.4 ± 92.3 ml, respectively. Significant differences (p < 0.01) were found between baseline and follow-up values for each parameter. The absolute growth rate of each parameter was + 0.1 ± 0.1 cm/year, + 2.1 ± 3.4 cm2/year, and + 2.0 ± 5.6 ml/year, respectively. The percent annualized growth rate for each parameter was +6.5 ± 7.3%/year, +18 ± 24%/year, and +46 ± 100%/year, respectively. Overall, 86% (190/222) of cysts increased in size over time; most notably 78% (174/222) increased by ≥ 6% in volume per year. None of the simple cysts developed septations or solid components on follow-up examinations. CONCLUSION: The majority of simple renal cysts increase in size over time, which was not associated with the development of complex features. Surface area and volume are the parameters most indicative of cyst growth or regression over time. In patients with enlarging asymptomatic simple renal cysts, no follow-up imaging is indicated.


Asunto(s)
Quistes , Enfermedades Renales Quísticas , Neoplasias Renales , Adulto , Quistes/diagnóstico por imagen , Humanos , Riñón/patología , Enfermedades Renales Quísticas/diagnóstico por imagen , Enfermedades Renales Quísticas/patología , Persona de Mediana Edad , Estudios Retrospectivos , Tomografía Computarizada por Rayos X/métodos
11.
J Magn Reson Imaging ; 55(2): 323-335, 2022 02.
Artículo en Inglés | MEDLINE | ID: mdl-33140551

RESUMEN

BACKGROUND: Phase-contrast (PC) MRI is a feasible and valid noninvasive technique to measure renal artery blood flow, showing potential to support diagnosis and monitoring of renal diseases. However, the variability in measured renal blood flow values across studies is large, most likely due to differences in PC-MRI acquisition and processing. Standardized acquisition and processing protocols are therefore needed to minimize this variability and maximize the potential of renal PC-MRI as a clinically useful tool. PURPOSE: To build technical recommendations for the acquisition, processing, and analysis of renal 2D PC-MRI data in human subjects to promote standardization of renal blood flow measurements and facilitate the comparability of results across scanners and in multicenter clinical studies. STUDY TYPE: Systematic consensus process using a modified Delphi method. POPULATION: Not applicable. SEQUENCE FIELD/STRENGTH: Renal fast gradient echo-based 2D PC-MRI. ASSESSMENT: An international panel of 27 experts from Europe, the USA, Australia, and Japan with 6 (interquartile range 4-10) years of experience in 2D PC-MRI formulated consensus statements on renal 2D PC-MRI in two rounds of surveys. Starting from a recently published systematic review article, literature-based and data-driven statements regarding patient preparation, hardware, acquisition protocol, analysis steps, and data reporting were formulated. STATISTICAL TESTS: Consensus was defined as ≥75% unanimity in response, and a clear preference was defined as 60-74% agreement among the experts. RESULTS: Among 60 statements, 57 (95%) achieved consensus after the second-round survey, while the remaining three showed a clear preference. Consensus statements resulted in specific recommendations for subject preparation, 2D renal PC-MRI data acquisition, processing, and reporting. DATA CONCLUSION: These recommendations might promote a widespread adoption of renal PC-MRI, and may help foster the set-up of multicenter studies aimed at defining reference values and building larger and more definitive evidence, and will facilitate clinical translation of PC-MRI. LEVEL OF EVIDENCE: 1 TECHNICAL EFFICACY STAGE: 1.


Asunto(s)
Riñón , Imagen por Resonancia Magnética , Consenso , Técnica Delphi , Humanos , Estudios Multicéntricos como Asunto , Circulación Renal
14.
Abdom Radiol (NY) ; 44(12): 3827-3842, 2019 12.
Artículo en Inglés | MEDLINE | ID: mdl-31676920

RESUMEN

Bladder cancer is the most common cancer of the urinary system and often presents with hematuria. Despite its relatively high incidence, bladder cancer is often under-recognized sonographically. Moreover, even when bladder abnormalities are identified, numerous other entities may mimic the appearance of bladder cancer. Given the incidence and prevalence of bladder cancer, it is important to recognize its variable appearance sonographically and distinguish it from its common mimics. We review the sonographic appearance of bladder cancer and its mimics, providing correlative CT/MR imaging as well as pathology. We stress the importance and advantage of ultrasound as a dynamic imaging modality, with the ability to optimize distinguishing bladder cancer from similar-appearing entities.


Asunto(s)
Hematuria/diagnóstico por imagen , Ultrasonografía/métodos , Neoplasias de la Vejiga Urinaria/diagnóstico por imagen , Diagnóstico Diferencial , Hematuria/patología , Humanos , Imagen por Resonancia Magnética/métodos , Tomografía Computarizada por Rayos X/métodos , Neoplasias de la Vejiga Urinaria/patología
15.
Ultrasound Q ; 34(3): 133-140, 2018 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-29346264

RESUMEN

Sonography of the cecum has come of age largely as a consequence of the successful evolution of appendiceal sonography as a useful tool in the evaluation of patients with right lower-quadrant pain. At some medical centers, graded-compression sonography (GCS) has become the initial imaging study of choice in the assessment of these individuals. The cecum serves as a helpful anatomic landmark for localization of the appendix in these examinations-providing a sonographic starting point in the search for the appendix. During GCS, primary pathology within the cecum itself can become evident, including a variety of processes, such as infectious, inflammatory, or neoplastic disorders, whose presentations commonly mimic that of appendicitis. The accurate diagnosis of cecal abnormalities and their differentiation from acute appendicitis play valuable roles in the management of affected patients because the options for further workup and subsequent treatment vary greatly according to the diagnosis at hand. Additionally, the compressed cecum often becomes an acoustic window into the right lower quadrant, revealing pathology apart from the appendix within the right iliac fossa. The purpose of this pictorial essay is to highlight the importance and value of performing a careful evaluation of the cecum during GCS of patients with suspected appendicitis and to review the differential diagnosis and imaging findings of primary cecal abnormalities whose clinical presentations can mimic that of acute appendicitis.


Asunto(s)
Dolor Abdominal/diagnóstico por imagen , Apendicitis/diagnóstico por imagen , Ciego/diagnóstico por imagen , Ultrasonografía Doppler en Color/métodos , Dolor Abdominal/etiología , Enfermedad Aguda , Adulto , Apéndice/diagnóstico por imagen , Femenino , Humanos , Masculino , Sensibilidad y Especificidad
16.
Invest Radiol ; 51(11): 701-705, 2016 11.
Artículo en Inglés | MEDLINE | ID: mdl-26885631

RESUMEN

OBJECTIVE: The purpose of this study was to assess the incidence of nephrogenic systemic fibrosis (NSF) before and after educational interventions, implementation of a clinical screening process, and change to gadobenate dimeglumine in patients who had an estimated glomerular filtration rate (eGFR) of 30 mL/min per 1.72 m or less. METHODS: This is a Health Insurance Portability and Accountability Act compliant, institutional review board exempt study. Two periods were studied-July 2005 to June 2006, during which gadodiamide was utilized as our magnetic resonance (MR) contrast agent, and November 2006 to August 2014, during which gadobenate dimeglumine was used as our MR contrast agent in patients who had an eGFR 30 mL/min per 1.72 m or less. In addition to a change in the MR contrast agent, education of our staff physician to the risks of NSF with MR contrast agents and the implementation of a clinical screening process occurred. The rate of NSF before and after the interventions was compared using the χ test. RESULTS: There was a statistically significant difference in the incidence of NSF in patients with an eGFR 30 mL/min per 1.72 m or less between the 2 periods: July 2005 to June 2006, 6 of 246 patients were diagnosed with NSF (P < 0.001), versus November 2006 to August 2014, 0 of 1423 patients were diagnosed with NSF. CONCLUSIONS: Our data demonstrates a marked decrease in the incidence of NSF after education of our referring physicians, implementation of clinical screening process, and change to gadobenate dimeglumine from gadodiamide in patients with renal insufficiency. This approach potentially provides an acceptable risk-benefit profile for patients with renal insufficiency that required MR imaging for clinical care.


Asunto(s)
Medios de Contraste/efectos adversos , Gadolinio DTPA/efectos adversos , Meglumina/análogos & derivados , Dermopatía Fibrosante Nefrogénica/epidemiología , Compuestos Organometálicos/efectos adversos , Insuficiencia Renal/diagnóstico , Insuficiencia Renal/epidemiología , Comorbilidad , Tasa de Filtración Glomerular/fisiología , Humanos , Aumento de la Imagen/métodos , Incidencia , Imagen por Resonancia Magnética , Meglumina/efectos adversos , Dermopatía Fibrosante Nefrogénica/fisiopatología , Insuficiencia Renal/fisiopatología , Estudios Retrospectivos , Medición de Riesgo/métodos , Factores de Riesgo
17.
J Magn Reson Imaging ; 42(2): 526-32, 2015 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-25425185

RESUMEN

PURPOSE: To evaluate velocity waveforms in muscle and to create a tool and algorithm for computing and analyzing muscle inertial forces derived from 2D phase contrast (PC) magnetic resonance imaging (MRI). MATERIALS AND METHODS: PC MRI was performed in the forearm of four healthy volunteers during 1 Hz cycles of wrist flexion-extension as well as in the lower leg of six healthy volunteers during 1 Hz cycles of plantarflexion-dorsiflexion. Inertial forces (F) were derived via the equation F = ma. The mass, m, was derived by multiplying voxel volume by voxel-by-voxel estimates of density via fat-water separation techniques. Acceleration, a, was obtained via the derivative of the PC MRI velocity waveform. RESULTS: Mean velocities in the flexors of the forearm and lower leg were 1.94 ± 0.97 cm/s and 5.57 ± 2.72 cm/s, respectively, as averaged across all subjects; the inertial forces in the flexors of the forearm and lower leg were 1.9 × 10(-3) ± 1.3 × 10(-3) N and 1.1 × 10(-2) ± 6.1 × 10(-3) N, respectively, as averaged across all subjects. CONCLUSION: PC MRI provided a promising means of computing muscle velocities and inertial forces-providing the first method for quantifying inertial forces.


Asunto(s)
Imagen por Resonancia Magnética/métodos , Movimiento/fisiología , Contracción Muscular/fisiología , Músculo Esquelético/anatomía & histología , Músculo Esquelético/fisiología , Reconocimiento de Normas Patrones Automatizadas/métodos , Aceleración , Adulto , Femenino , Humanos , Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador/métodos , Imagenología Tridimensional/métodos , Masculino , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Estrés Mecánico , Articulación de la Muñeca/fisiología
18.
J Magn Reson Imaging ; 41(5): 1475-85, 2015 May.
Artículo en Inglés | MEDLINE | ID: mdl-24964097

RESUMEN

PURPOSE: To assess measurements of pulse wave velocity (PWV) and wall shear stress (WSS) in a swine model of atherosclerosis. MATERIALS AND METHODS: Nine familial hypercholesterolemic (FH) swine with angioplasty balloon catheter-induced atherosclerotic lesions to the abdominal aorta (injured group) and 10 uninjured FH swine were evaluated with a 4D phase contrast (PC) magnetic resonance imaging (MRI) acquisition, as well as with radial and Cartesian 2D PC acquisitions, on a 3T MR scanner. PWV values were computed from the 2D and 4D PC techniques, compared between the injured and uninjured swine, and validated against reference standard pressure probe-based PWV measurements. WSS values were also computed from the 4D PC MRI technique and compared between injured and uninjured groups. RESULTS: PWV values were significantly greater in the injured than in the uninjured groups with the 4D PC MRI technique (P = 0.03) and pressure probes (P = 0.02). No significant differences were found in PWV between groups using the 2D PC techniques (P = 0.75-0.83). No significant differences were found for WSS values between the injured and uninjured groups. CONCLUSION: The 4D PC MRI technique provides a promising means of evaluating PWV and WSS in a swine model of atherosclerosis, providing a potential platform for developing the technique for the early detection of atherosclerosis.


Asunto(s)
Aorta/fisiopatología , Aterosclerosis/fisiopatología , Hiperlipoproteinemia Tipo II/fisiopatología , Angiografía por Resonancia Magnética/métodos , Análisis de la Onda del Pulso , Resistencia al Corte , Animales , Presión Arterial , Aterosclerosis/patología , Velocidad del Flujo Sanguíneo , Femenino , Hiperlipoproteinemia Tipo II/patología , Imagenología Tridimensional/métodos , Masculino , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Porcinos
19.
Cardiovasc Diagn Ther ; 4(2): 193-206, 2014 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-24834415

RESUMEN

Atherosclerosis is the leading cause of cardiovascular disease (CVD) in the Western world. In the early development of atherosclerosis, vessel walls remodel outwardly such that the vessel luminal diameter is minimally affected by early plaque development. Only in the late stages of the disease does the vessel lumen begin to narrow-leading to stenoses. As a result, angiographic techniques are not useful for diagnosing early atherosclerosis. Given the absence of stenoses in the early stages of atherosclerosis, CVD remains subclinical for decades. Thus, methods of diagnosing atherosclerosis early in the disease process are needed so that affected patients can receive the necessary interventions to prevent further disease progression. Pulse wave velocity (PWV) is a biomarker directly related to vessel stiffness that has the potential to provide information on early atherosclerotic disease burden. A number of clinical methods are available for evaluating global PWV, including applanation tonometry and ultrasound. However, these methods only provide a gross global measurement of PWV-from the carotid to femoral arteries-and may mitigate regional stiffness within the vasculature. Additionally, the distance measurements used in the PWV calculation with these methods can be highly inaccurate. Faster and more robust magnetic resonance imaging (MRI) sequences have facilitated increased interest in MRI-based PWV measurements. This review provides an overview of the state-of-the-art in MRI-based PWV measurements. In addition, both gold standard and clinical standard methods of computing PWV are discussed.

20.
Acad Radiol ; 20(6): 699-704, 2013 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-23510798

RESUMEN

RATIONALE AND OBJECTIVES: The aim of this study was to assess the repeatability and internal consistency of flow measurements in the renal arteries and pararenal aorta with the use of standard two-dimensional (2D) and novel four-dimensional (4D) phase contrast (PC) magnetic resonance imaging (MRI). MATERIALS AND METHODS: Ten healthy volunteers were imaged with a radially undersampled 4D PC technique centered over the renal arteries and with four 2D PC slices placed in the supra/infrarenal aorta and the left/right renal arteries; this MRI exam was performed twice on each subject. Flow measurements in all four vessels were computed from 2D and 4D PC data sets. Student's t-tests (P < .05) were used to assess differences between in-flow (suprarenal aorta) and out-flow (infrarenal aorta + left renal artery + right renal artery) for the 2D and 4D techniques, to compare in- and out-flow, and to compare repeated measurements of 2D and 4D flow measurements. RESULTS: No significant differences were found in repeated measurements of 2D (P = .15) or 4D (P = .39) data. No significant difference was found between 2D (3.4 ± 2.8 mL/cardiac cycle) and 4D (3.5 ± 2.7 mL/cardiac cycle) in- and out-flow differences (P = .88). Out-flow was greater than in-flow for 2D measurements (P = .003); no difference was found for 4D measurements. CONCLUSION: The 2D and 4D techniques demonstrated strong repeatability and internal consistency of flow measurements in the renal arteries and pararenal aorta.


Asunto(s)
Algoritmos , Aorta/fisiología , Técnicas de Imagen Sincronizada Cardíacas/métodos , Interpretación de Imagen Asistida por Computador/métodos , Imagenología Tridimensional/métodos , Angiografía por Resonancia Magnética/métodos , Arteria Renal/fisiología , Adulto , Aorta/anatomía & histología , Velocidad del Flujo Sanguíneo/fisiología , Femenino , Humanos , Aumento de la Imagen/métodos , Masculino , Arteria Renal/anatomía & histología , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...