Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 42
Filtrar
1.
AIDS Behav ; 27(5): 1716-1725, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-36318431

RESUMEN

Internet-recruited gay, bisexual, and other men who have sex with men (MSM) were offered HIV self-tests (HIVSTs) after completing baseline, 3-, 6-, and 9-month follow-up surveys. The surveys asked about the use and distribution of these HIVSTs. Among 995 who reported on their distribution of HIVSTs, 667 (67.0%) distributed HIVSTs to their social network associates (SNAs), which resulted in 34 newly identified HIV infections among 2301 SNAs (1.5%). The main reasons participants reported not distributing HIVSTs included: wanting to use the HIVSTs themselves (74.9%); thinking that their SNAs would get angry or upset if offered HIVSTs (12.5%); or not knowing that they could give the HIVSTs away (11.3%). Self-testing programs can provide multiple HIVSTs and encourage the distribution of HIVST by MSM to their SNAs to increase awareness of HIV status among persons disproportionately affected by HIV.


RESUMEN: Hombres gais, bisexuales y otros hombres que indicaron tener contacto sexual con hombres (MSM, por sus siglas en inglés) fueron reclutados por el Internet y se les ofreció autopruebas del VIH (HIVST, por sus siglas en inglés) después de completar una encuestas inicial y encuestas de seguimiento a los 3, 6 y 9 meses. Las encuestas recogieron datos sobre el uso y distribución de estas autopruebas del VIH. De los 995 MSM que indicaron distribuir las autopruebas, 667 (67.0%) distribuyeron las autopruebas a personas en sus redes sociales (SNA, por sus siglas en inglés), resultando en 34 nuevas infecciones por el VIH identificadas entre 2,301 SNA (1.5%). Las razones principales por las que algunos participantes no distribuyeron las autopruebas del VIH incluyen: el deseo de utilizar las autopruebas del VIH para sí mismos (74.9%); pensar que las SNA se enfadarían o molestarían si se les ofreciesen autopruebas del VIH (12.5%); o no saber que podían distribuir las autopruebas del VIH (11.3%). Los programas que proporcionen múltiples autopruebas del VIH podrían alentar la distribución de las autopruebas por parte de los MSM a las SNA para aumentar el conocimento sobre el estado del VIH entre personas afectadas de manera desproporcionada por el VIH.


Asunto(s)
Infecciones por VIH , Minorías Sexuales y de Género , Masculino , Humanos , Homosexualidad Masculina , Infecciones por VIH/diagnóstico , Infecciones por VIH/epidemiología , Infecciones por VIH/prevención & control , Conducta Sexual , Red Social
2.
J Clin Virol ; 129: 104479, 2020 08.
Artículo en Inglés | MEDLINE | ID: mdl-32531665

RESUMEN

BACKGROUND: Currently, FDA-approved HIV-1 viral load (VL) assays use venipuncture-derived plasma. The Hologic Panther system uses 0.7 mL total volume for the Aptima HIV-1 Quant Assay standard (APT-Quant-std) and dilution (APT-Quant-dil) protocols. However, smaller plasma volumes from fingerstick whole blood (FSB) collected in EDTA-microtainer tubes (MCT) could provide an easier sample collection method for HIV-1 VL testing. OBJECTIVES: To evaluate the performance of the APT-Quant-std compared to the Roche CAP/CTM and Abbott m2000RT VL assays and an alternative APTQuant 1:7 dilution protocol, the latter using 100 µL of MCT-derived plasma from FSB. STUDY DESIGN: Linearity was determined using commercial HIV-1 RNA plasma controls. Dilutions ranging 1.56-2.95 log10 copies/mL were prepared to determine the APT-Quant-dil Limit of Quantitation (LOQ) using Probit analysis. Specificity of APT-Quant-std was calculated using 326 HIVnegative samples. To evaluate agreement, 329 plasma specimens were tested with APT-Quant-std, CAP/CTM, and m2000RT. Forty-seven matched venipuncture and MCT-derived plasma specimens were tested with APT-Quant-std and APT-Quant-dil. RESULTS: Among the RNA controls, specificity was 99.69 % for APT-Quant-std. The R2 values were 0.988 (APT-Quant-std/CAP/CTM), 0.980 (APT-Quant-std/ m2000RT), and 0.997 (APT-Quant-std/APT-Quant-dil). The APT-Quant-dil LOQ was estimated at 2.7 log10 copies/mL (500 copies/mL) (95 %CI 2.62-2.87). At 2.3 log10 copies/mL (200 copies/mL), the overall agreement was 91.0 % for APT-Quant-std/CAP/CTM, 85.7 % for APT-Quant-std/m2000RT, and 82.9 % for APT-Quant-std/APT-Quant-dil. Quantified APT-Quant-std results were on average 0.2 log10 copies/mL higher than CAP/CTM and m2000RT and 0.14 log10 copies/mL higher than APT-Quant-dil. CONCLUSION: APT-Quant showed similar performance compared to the CAP/CTM and m2000RT assays and remains sensitive and accurate using the dilution protocol.


Asunto(s)
Infecciones por VIH , VIH-1 , Infecciones por VIH/diagnóstico , VIH-1/genética , Humanos , ARN , ARN Viral/genética , Sensibilidad y Especificidad , Carga Viral
3.
Sex Transm Dis ; 47(5S Suppl 1): S13-S17, 2020 05.
Artículo en Inglés | MEDLINE | ID: mdl-32343517

RESUMEN

BACKGROUND: Geenius HIV 1/2 Supplemental Assay (Geenius; Bio-Rad Laboratories) is the only Food and Drug Administration-approved HIV-1/HIV-2 antibody differentiation test for the second step in the HIV laboratory testing algorithm. We characterized the occurrence of true HIV-1 and HIV-2 infections as well as false results in 6 US clinical laboratories using Geenius. METHODS: We examined routine HIV testing outcome data from the time the laboratories began using the algorithm with Geenius until September 30, 2017. We calculated the positive predictive value for Geenius HIV-1 and HIV-2 reactivity separately. RESULTS: Of 5,046,684 specimens tested, 41,791 had reactive antigen/antibody test results. Most specimens with reactive antigen/antibody results were HIV-1 antibody-positive established infections (n = 32,421), 1,865 of which also had indeterminate HIV-2 bands present. Ninety-three specimens were HIV-2 antibody positive or untypable for HIV-1/HIV-2 antibody. Acute HIV-1 infections were found in 528 specimens; 881 specimens lacked the nucleic acid test to determine the possibility of acute HIV-1 infection. False-positive antigen/antibody test results were present in 7505 specimens. Few specimens (n = 363) had false-positive antigen/antibody results with indeterminate Geenius and negative HIV-1 nucleic acid test results. The positive predictive values of Geenius reactivity were 99.4% for HIV-1 and 4.3% for HIV-2. CONCLUSIONS: Routine testing using the laboratory testing algorithm with Geenius resulted in most specimens resolving as HIV negative or HIV-1 positive. The occurrence of indeterminate HIV-2 bands with a Geenius final assay interpretation of HIV-1 positive was more common than true HIV-2 infections. Reporting indeterminate HIV-2 results in this situation may cause confusion with interpreting HIV infection status.


Asunto(s)
Anticuerpos Anti-VIH/sangre , Infecciones por VIH/sangre , Infecciones por VIH/diagnóstico , VIH-1/inmunología , VIH-2/inmunología , Laboratorios/normas , Algoritmos , Infecciones por VIH/virología , Prueba de VIH , VIH-1/aislamiento & purificación , VIH-2/aislamiento & purificación , Humanos , Inmunoensayo/métodos , Valor Predictivo de las Pruebas , Sensibilidad y Especificidad , Pruebas Serológicas/métodos
4.
MMWR Recomm Rep ; 69(2): 1-17, 2020 04 10.
Artículo en Inglés | MEDLINE | ID: mdl-32271723

RESUMEN

Hepatitis C virus (HCV) infection is a major source of morbidity and mortality in the United States. HCV is transmitted primarily through parenteral exposures to infectious blood or body fluids that contain blood, most commonly through injection drug use. No vaccine against hepatitis C exists and no effective pre- or postexposure prophylaxis is available. More than half of persons who become infected with HCV will develop chronic infection. Direct-acting antiviral treatment can result in a virologic cure in most persons with 8-12 weeks of all-oral medication regimens. This report augments (i.e., updates and summarizes) previously published recommendations from CDC regarding testing for HCV infection in the United States (Smith BD, Morgan RL, Beckett GA, et al. Recommendations for the identification of chronic hepatitis C virus infection among persons born during 1945-1965. MMWR Recomm Rec 2012;61[No. RR-4]). CDC is augmenting previous guidance with two new recommendations: 1) hepatitis C screening at least once in a lifetime for all adults aged ≥18 years, except in settings where the prevalence of HCV infection is <0.1% and 2) hepatitis C screening for all pregnant women during each pregnancy, except in settings where the prevalence of HCV infection is <0.1%. The recommendation for HCV testing that remains unchanged is regardless of age or setting prevalence, all persons with risk factors should be tested for hepatitis C, with periodic testing while risk factors persist. Any person who requests hepatitis C testing should receive it, regardless of disclosure of risk, because many persons might be reluctant to disclose stigmatizing risks.


Asunto(s)
Hepatitis C/diagnóstico , Tamizaje Masivo , Adulto , Centers for Disease Control and Prevention, U.S. , Humanos , Guías de Práctica Clínica como Asunto , Estados Unidos
5.
JMIR Res Protoc ; 9(1): e16332, 2020 Jan 27.
Artículo en Inglés | MEDLINE | ID: mdl-32012115

RESUMEN

BACKGROUND: HIV testing guidelines provided by the Centers for Disease Control and Prevention (CDC) are continually changing to reflect advancements in new testing technology. Evaluation of existing and new point-of-care (POC) HIV tests is crucial to inform testing guidelines and provide information to clinicians and other HIV test providers. Characterizing the performance of POC HIV tests using unprocessed specimens can provide estimates for the window period of detection, or the time from HIV acquisition to test positivity, which allows clinicians and other HIV providers to select the appropriate POC HIV tests for persons who may be recently infected with HIV. OBJECTIVE: This paper describes the protocols and procedures used to evaluate the performance of the newest POC tests and determine their sensitivity during early HIV infection. METHODS: Project DETECT is a CDC-funded study that is evaluating POC HIV test performance. Part 1 is a cross-sectional, retrospective study comparing behavioral characteristics and HIV prevalence of the overall population of the Public Health-Seattle & King County (PHSKC) Sexually Transmitted Disease (STD) Clinic to Project DETECT participants enrolled in part 2. Part 2 is a cross-sectional, prospective study evaluating POC HIV tests in real time using unprocessed whole blood and oral fluid specimens. A POC nucleic acid test (NAT) was added to the panel of HIV tests in June 2018. Part 3 is a longitudinal, prospective study evaluating seroconversion sensitivity of POC HIV tests through serial follow-up testing. For comparison, HIV-1 RNA and HIV-1/HIV-2 antigen/antibody tests are also performed for participants enrolled in part 2 or 3. A behavioral survey that collects information about demographics, history of HIV testing, STD history, symptoms of acute HIV infection, substance use, sexual behaviors in the aggregate and with recent partners, and use of pre-exposure prophylaxis and antiretroviral therapy is completed at each part 2 or 3 visit. RESULTS: Between September 2015 and March 2019, there were 14,990 Project DETECT-eligible visits (part 1) to the PHSKC STD Clinic resulting in 1819 part 2 Project DETECT study visits. The longitudinal study within Project DETECT (part 3) enrolled 27 participants with discordant POC test results from their part 2 visit, and 10 (37%) were followed until they had fully seroconverted with concordant positive POC test results. Behavioral survey data and HIV test results, sensitivity, and specificity will be presented elsewhere. CONCLUSIONS: Studies such as Project DETECT are critical for evaluating POC HIV test devices as well as describing characteristics of persons at risk for HIV acquisition in the United States. HIV tests in development, including POC NATs, will provide new opportunities for HIV testing programs. INTERNATIONAL REGISTERED REPORT IDENTIFIER (IRRID): RR1-10.2196/16332.

6.
Sex Transm Dis ; 47(5S Suppl 1): S26-S31, 2020 05.
Artículo en Inglés | MEDLINE | ID: mdl-31977972

RESUMEN

BACKGROUND: There is benefit to early HIV-1 diagnosis and treatment, but there is no Food and Drug Administration-approved quantitative assay with a diagnostic claim. We compared the performance of the Hologic Aptima HIV-1 Quant (APT-Quant) and Aptima HIV-1 Qual (APT-Qual) assays for diagnostic use and the performance of a diagnostic algorithm consisting of Bio-Rad BioPlex 2200 HIV Ag-Ab assay (BPC) followed by APT-Quant (2-test) compared with BPC followed by Geenius HIV-1/2 supplemental assay (Geenius) with reflex to APT-Qual (3-test). METHODS: Five hundred twenty-four plasma, which included 419 longitudinal specimens from HIV-1 seroconverters (78 were after initiating antiretroviral therapy [ART]) and 105 from ART-naive persons with established HIV-1 infections, were used to evaluate APT-Quant performance for diagnostic use. Specimens from 200 HIV-negative persons were used to measure specificity. For the algorithm comparison, BPC-reactive specimens were evaluated with the 2-test or 3-test algorithm. McNemar's test was used to compare performance. RESULTS: The APT-Quant detected more samples early in infection compared with APT-Qual. The APT-Quant specificity was 99.8%. Before ART initiation, the algorithms performed similarly among samples from different stages of infection. After ART initiation, the 3-test algorithm performed significantly better (P = 0.0233). CONCLUSIONS: The APT-Quant has excellent performance for diagnostic use. The 2-test algorithm works well in ART-naive samples, but its performance decreases after the IgG response is elicited and with ART-induced suppressed viremia. Providing confirmation and viral load assay with 1 test result could be advantageous for patient care. However, additional factors and challenges associated with the implementation of this 2-test algorithm, such as cost, specimen type, and collection need further evaluation.


Asunto(s)
Anticuerpos Anti-VIH/sangre , Infecciones por VIH/sangre , VIH-1/aislamiento & purificación , Técnicas de Amplificación de Ácido Nucleico/normas , ARN Viral/sangre , Juego de Reactivos para Diagnóstico/normas , Carga Viral/métodos , Algoritmos , Infecciones por VIH/diagnóstico , Infecciones por VIH/tratamiento farmacológico , VIH-1/genética , Humanos , Reacción en Cadena de la Polimerasa/métodos , ARN Viral/genética , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
7.
MMWR Morb Mortal Wkly Rep ; 69(3): 63-66, 2020 Jan 24.
Artículo en Inglés | MEDLINE | ID: mdl-31971928

RESUMEN

Since 2014, the recommended laboratory testing algorithm for diagnosing human immunodeficiency virus (HIV) infection has included a supplemental HIV-1/HIV-2 differentiation test to confirm infection type on the basis of the presence of type-specific antibodies (1). Correctly identifying HIV-1 and HIV-2 infections is vital because their epidemiology and clinical management differ. To describe the percentage of diagnoses for which an HIV-1/HIV-2 differentiation test result was reported and to categorize HIV type based on laboratory test results, 2010-2017 data from CDC's National HIV Surveillance System (NHSS) were analyzed. During 2010-2017, a substantial increase in the number of HIV-1/HIV-2 differentiation test results were reported to NHSS, consistent with implementation of the HIV laboratory-based testing algorithm recommended in 2014. However, >99.9% of all HIV infections identified in the United States were categorized as HIV-1, and the number of HIV-2 diagnoses (mono-infection or dual-infection) remained extremely low (<0.03% of all HIV infections). In addition, the overall number of false positive HIV-2 test results produced by the HIV-1/HIV-2 differentiation increased. The diagnostic value of a confirmatory antibody differentiation test in a setting with sensitive and specific screening tests and few HIV-2 infections might be limited. Evaluation and consideration of other HIV tests approved by the Food and Drug Administration (FDA) that might increase efficiencies in the CDC and Association of Public Health Laboratories-recommended HIV testing algorithm are warranted.


Asunto(s)
Pruebas Diagnósticas de Rutina/métodos , Infecciones por VIH/diagnóstico , Infecciones por VIH/virología , VIH-2/aislamiento & purificación , Adolescente , Adulto , Algoritmos , Centers for Disease Control and Prevention, U.S. , Femenino , Infecciones por VIH/epidemiología , Humanos , Laboratorios , Masculino , Persona de Mediana Edad , Estados Unidos/epidemiología , Adulto Joven
8.
Sex Transm Dis ; 47(5S Suppl 1): S18-S25, 2020 05.
Artículo en Inglés | MEDLINE | ID: mdl-31895304

RESUMEN

BACKGROUND: Since 2014, the recommended algorithm for laboratory diagnosis of HIV infection in the United States has consisted of an HIV-1/2 antigen/antibody (Ag/Ab) test followed by an HIV-1/2 antibody (Ab) differentiation test and, if necessary, a diagnostic HIV-1 nucleic acid test to resolve discordant or indeterminate results. METHODS: Using stored specimens from persons seeking HIV testing who had not received a previous diagnosis or treatment, we compared the performance of a 3-step alternative algorithm consisting of an Ag/Ab test followed by a quantitative HIV-1 RNA viral load assay and, if viral load is not detected, an Ab differentiation test, to that of the recommended algorithm. We calculated the sensitivity and specificity of 5 Ag/Ab tests and the proportion of specimens correctly classified by the alternative algorithm compared with the recommended algorithm. Results were examined separately for specimens classified as early infection, established infection, and false-reactive screening. RESULTS: Sensitivity and specificity were similar among all Ag/Ab tests. Viral load quantification correctly classified all specimens from early infection, all false-reactive screening specimens, and the majority of specimens from established infection. CONCLUSIONS: Although cost, regulatory barriers, test availability, and the ability to differentiate early from established infection must be considered, this alternative algorithm can potentially decrease the total number of tests performed and reduce turnaround time, thereby streamlining HIV diagnosis and initiation of treatment.


Asunto(s)
Anticuerpos Anti-VIH/sangre , Infecciones por VIH/diagnóstico , VIH-1/genética , VIH-1/aislamiento & purificación , Laboratorios/normas , ARN Viral/genética , Algoritmos , VIH-1/inmunología , VIH-2/genética , VIH-2/inmunología , VIH-2/aislamiento & purificación , Humanos , Inmunoensayo , Valor Predictivo de las Pruebas , Sensibilidad y Especificidad , Estados Unidos , Carga Viral
9.
J Clin Virol ; 124: 104282, 2020 03.
Artículo en Inglés | MEDLINE | ID: mdl-31991321

RESUMEN

BACKGROUND: The performance of recently approved point-of-care (POC) HIV tests should be assessed using unprocessed specimens. OBJECTIVE: To evaluate the sensitivity and specificity of four POC HIV tests using whole blood (WB) and two using oral fluid (OF) among persons recruited from health clinics in Seattle, Washington, during September 2015-September 2017. STUDY DESIGN: Participants were tested with the POC tests, additional plasma and serum were collected for laboratory testing, and participant- reported use of antiretroviral therapy (ART) or pre-exposure prophylaxis (PrEP) was recorded. Participants testing negative on all tests could reenroll every 90 days. Specimens from persons previously diagnosed with HIV infection as well as from those who were newly diagnosed during the study were included in the sensitivity estimate. Sensitivity and specificity were calculated based on HIV status determined by laboratory testing. RESULTS: Of 1,256 visits, 179 were from persons with HIV infection; 120 of these were taking ART. Among 1,077 visits from participants not diagnosed with HIV, PrEP use was reported at 155 (14.4%) visits. Sensitivity was similar among POC WB tests (95.53%-97.21%; p>0.05). Among participants on ART, sensitivity was lower for the same test performed on OF compared to WB (p<0.003). Specificity was high for all tests (99.44%- 100.00%); we did not detect specificity differences with PrEP use. CONCLUSIONS: These POC tests displayed relatively high sensitivity and specificity using unprocessed specimens, suggesting their effectiveness in identifying HIV infections whenever laboratory-based testing is not feasible. Nonetheless, clients with recent risk should retest to rule out the possibility of a false-negative result.


Asunto(s)
Infecciones por VIH/diagnóstico , Prueba de VIH , Sistemas de Atención de Punto , Fármacos Anti-VIH/uso terapéutico , Reacciones Falso Negativas , Reacciones Falso Positivas , Infecciones por VIH/tratamiento farmacológico , Humanos , Profilaxis Pre-Exposición , Sensibilidad y Especificidad , Manejo de Especímenes
11.
Sex Transm Dis ; 47(5S Suppl 1): S8-S12, 2020 05.
Artículo en Inglés | MEDLINE | ID: mdl-31876868

RESUMEN

BACKGROUND: In 2016, HIV-2 nucleic acid testing (NAT) was added to a shared service program that conducts HIV-1 NAT for public health laboratories performing the recommended algorithm for diagnosing HIV. Here, we evaluate the usefulness of HIV-2 NAT in this program as compared with HIV-1 NAT. METHODS: Specimens eligible for HIV-1 NAT were reactive on an HIV-1/2 antibody or antigen/antibody initial test and nonreactive or indeterminate on a supplemental antibody test or were reactive for HIV-1 antigen-only on an HIV-1/2 antigen/antibody initial test. Specimens eligible for HIV-2 NAT were reactive on an initial test, HIV-2 indeterminate or HIV indeterminate on a supplemental antibody test and had no detectable HIV-1 RNA or were reactive for HIV-2 antibody on an HIV-1/2 antigen/antibody test, and this reactivity was not confirmed with a supplemental antibody assay. All specimens were tested in a reference laboratory using APTIMA HIV-1 qualitative RNA and/or a validated qualitative HIV-2 RNA real-time PCR assay. RESULTS: During 2016 to 2019, HIV-1 RNA was detected in 234 (14%) of 1731 specimens tested. HIV-2 RNA was not detected in 52 specimens tested. Median time from specimen collection to reporting of HIV-1 and HIV-2 NAT results by year ranged from 9 to 10 days and from 22 to 27 days, respectively. Two specimens with HIV-2 indeterminate results on a supplemental antibody test had detectable HIV-1 RNA. CONCLUSIONS: A shared service model for HIV-1 NAT is both feasible and beneficial for public health laboratories. However, because no HIV-2 infections were detected, our data suggest that this program should reconsider the usefulness of HIV-2 NAT testing.


Asunto(s)
Pruebas Diagnósticas de Rutina/métodos , Infecciones por VIH/diagnóstico , VIH-1/genética , VIH-2/genética , Técnicas de Amplificación de Ácido Nucleico/métodos , ARN Viral/sangre , Algoritmos , VIH-1/aislamiento & purificación , VIH-2/aislamiento & purificación , Humanos , Laboratorios , Tamizaje Masivo , Salud Pública , Reacción en Cadena en Tiempo Real de la Polimerasa , Sensibilidad y Especificidad , Virología/métodos
12.
J Clin Virol ; 122: 104214, 2020 01.
Artículo en Inglés | MEDLINE | ID: mdl-31835210

RESUMEN

BACKGROUND: Cepheid's Xpert HIV-1 Viral Load (Xpert VL), a simplified, automated, single-use quantitative assay used with the GeneXpert System, is not FDA approved. OBJECTIVES: Using stored plasma, we conducted a study to assess the ability of Xpert VL to quantify viral load relative to the Roche COBAS AmpliPrep/COBAS TaqMan HIV-1 (Cobas VL) and to examine the use of the Xpert VL as a qualitative diagnostic test. STUDY DESIGN: Following HIV-1 viral stock dilutions, we conducted a probit analysis to identify the concentration where 95 % of specimens had quantified VLs. We also examined Xpert and Cobas log VL correlation in linearity panels; compared the proportion of 220 seroconverter specimens with virus detected using McNemar's test; and tested specimens from persons with untreated, established HIV-1 infection (n=149) and uninfected persons (n=497). Furthermore, we examined Xpert VL as a qualitative test in seroconverter specimens with early (n=20) and later (n=68) acute infections. RESULTS: At 1.80 log10 copies/mL, 95 % of specimens had quantifiable virus using Xpert VL. Xpert and Cobas VLs were highly correlated (R2=0.994). The proportion of seroconverter specimens with virus detected using Cobas and with Xpert VL was not statistically different (p=0.0578). Xpert VL detected 97.9 % of established infections, and specificity was 99.80 % (95 % CI 98.87%-99.99%). Xpert VL detected 90 % and 98.5 % of early and later acute infections, respectively. CONCLUSIONS: If approved, Xpert VL could allow U.S. laboratories that cannot bring on large, complex testing platforms to conduct HIV monitoring. An approval for diagnostic use may provide timely identification of HIV infections.


Asunto(s)
Infecciones por VIH/diagnóstico , Técnicas de Amplificación de Ácido Nucleico/métodos , ARN Viral/sangre , Carga Viral/métodos , Automatización de Laboratorios , Infecciones por VIH/sangre , Infecciones por VIH/virología , VIH-1 , Humanos , Sensibilidad y Especificidad , Manejo de Especímenes
13.
AIDS Behav ; 23(2): 359-365, 2019 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-30173345

RESUMEN

The Centers for Disease Control and Prevention recommends annual HIV tests for men who have sex with men (MSM), yet some have never tested. We analyzed data from the MSM Testing Initiative. Of 68,185 HIV tests, 8% were with MSM who never previously tested ("first-time testers"). Among tests with first-time testers, 70.7% were with MSM from racial or ethnic minorities; 66.5% were with MSM younger than 30 years. Tests with MSM who reported female partners only during the past year (compared to male partners only) or were recruited for at-home testing (compared to venue-based recruitment) were 4 times (prevalence ratio [PR] 3.62, 95% CI 3.15-4.15) and 5 times as likely (PR 4.69, 95% CI 4.22-5.21) to be associated with first-time testing. At-home testing and focusing on MSM who have sex with women may be effective methods for reaching MSM who are first-time testers.


Asunto(s)
Infecciones por VIH/diagnóstico , Conducta Sexual , Parejas Sexuales , Minorías Sexuales y de Género/estadística & datos numéricos , Adolescente , Adulto , Bisexualidad , Etnicidad , Infecciones por VIH/prevención & control , Homosexualidad Masculina , Humanos , Masculino , Tamizaje Masivo , Persona de Mediana Edad , Grupos Minoritarios , Prevalencia , Grupos Raciales , Estados Unidos , Adulto Joven
14.
AIDS Behav ; 23(4): 893-899, 2019 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-30264206

RESUMEN

HIV-positive men who have sex with men (MSM) were recruited on www.Facebook.com and www.Poz.com to give HIV self-tests to their contacts. Study participants completed a baseline survey, were given two self-tests, and completed a survey 2 months later. Of 133 eligible men, 40 (30%) completed both surveys. Most participants were 30-54 years old and non-Hispanic white. Some had a detectable viral load (n = 4), had condomless anal sex with male partners of negative or unknown status (n = 17), and had met anal sex partners at gay dating websites (n = 23). Of 80 self-tests given to participants, 59 (74%) were distributed, primarily to non-Hispanic white MSM, 30-54 years old who were friends. Participants reported results from 31 distributed tests; 2 sex partners of participants had positive results. Participants indicated these two persons were unaware of their infections. Expanding recruitment websites might reach non-white MSM. Unrecognized infections were identified through online recruitment and self-test distribution via HIV-positive persons.


Asunto(s)
Serodiagnóstico del SIDA/estadística & datos numéricos , Infecciones por VIH/diagnóstico , Seropositividad para VIH , Homosexualidad Masculina , Tamizaje Masivo/métodos , Autocuidado/métodos , Parejas Sexuales , Población Blanca/estadística & datos numéricos , Serodiagnóstico del SIDA/métodos , Adulto , Infecciones por VIH/prevención & control , Humanos , Relaciones Interpersonales , Masculino , Tamizaje Masivo/organización & administración , Persona de Mediana Edad , Autocuidado/psicología , Enfermedades de Transmisión Sexual/prevención & control , Encuestas y Cuestionarios
15.
J Clin Virol ; 104: 89-91, 2018 07.
Artículo en Inglés | MEDLINE | ID: mdl-29803089

RESUMEN

BACKGROUND: The capacity of HIV Antigen/Antibody (Ag/Ab) immunoassays (IA) to detect HIV-1 p24 antigen has resulted in improved detection of HIV-1 infections in comparison to Ab-only screening assays. Since its introduction in the US, studies have shown that the Determine HIV-1/2 Ag/Ab Combo assay (Determine Ag/Ab) detects HIV infection earlier than laboratory-based IgM/IgG-sensitive IAs, but its sensitivity for HIV-1 p24 Ag detection is reduced compared to laboratory-based Ag/Ab assays. However, further evaluation is needed to assess its capacity to detect acute HIV-1 infection. OBJECTIVE: To assess the performance of Determine Ag/Ab in serum from acute HIV-1 infections. STUDY DESIGN: Select serum specimens that screened reactive on a laboratory-based Ag/Ab IA or IgM/IgG Ab-only IA, with a negative or indeterminate supplemental antibody test and detectable HIV-1 RNA were retrospectively tested with Determine Ag/Ab. Results were compared with those of the primary screening immunoassay to evaluate concordance within this set of algorithm-defined acute infections. RESULTS: Of 159 algorithm-defined acute HIV-1 specimens, Determine Ag/Ab was reactive for 105 resulting in 66.0% concordance. Of 125 that were initially detected by a laboratory-based Ag/Ab IA, 81 (64.8%) were reactive by Determine Ag/Ab. A total of 34 acute specimens were initially detected by a laboratory-based IgM/IgG Ab-only IA and 24 (70.6%) of those were reactive by Determine Ag/Ab. CONCLUSIONS: Due to their enhanced sensitivity, laboratory-based Ag/Ab IAs continue to be preferred over the Determine Ag/Ab as the screening method used by laboratories conducting HIV diagnostic testing on serum and plasma specimens.


Asunto(s)
Algoritmos , Anticuerpos Anti-VIH/sangre , Antígenos VIH/sangre , Infecciones por VIH/diagnóstico , Inmunoensayo/métodos , VIH-1/inmunología , VIH-2/inmunología , Humanos , Estudios Retrospectivos , Sensibilidad y Especificidad , Factores de Tiempo
16.
Prev Med ; 107: 75-80, 2018 02.
Artículo en Inglés | MEDLINE | ID: mdl-29126916

RESUMEN

Identifying patients at-risk for HIV infection, such as men who have sex with men (MSM), is an important step in providing HIV testing and prevention interventions. It is unknown how primary care providers (PCPs) assess MSM status and related HIV-risk factors. We analyzed data from a panel-derived web-based survey for healthcare providers conducted in 2014 to describe how PCPs in the U.S. determined their patients' MSM status. We calculated adjusted prevalence ratios (aPR) and 95% confidence intervals (CI) to describe PCP characteristics associated with systematically determining MSM status (i.e., PCP used "a patient-completed questionnaire" or "routine verbal review of sex history"). Among the 1008 PCPs, 56% determined MSM status by routine verbal review of sexual history; 41% by patient disclosure; 39% by questions driven by symptoms/history; 23% by using a patient-completed questionnaire, and 9% didn't determine MSM status. PCPs who systematically determined MSM status (n=665; 66%) were more likely to be female (aPR=1.16, CI=1.06-1.26), to be affiliated with a teaching hospital (aPR=1.15, CI=1.06-1.25), to routinely screen all patients aged 13-64 for HIV (aPR=1.29, CI=1.18-1.41), and to estimate that 6% or more of their male patients are MSM (aPR=1.14, CI=1.01-1.30). The majority of PCPs assessed MSM status and HIV risk factors through routine verbal reviews of sexual history. Implementing a systematic approach to identify MSM status and assess risk may allow PCPs to identify more patients needing frequent HIV testing and other preventive services, while mitigating socio-cultural barriers to obtaining such information.


Asunto(s)
Personal de Salud/estadística & datos numéricos , Homosexualidad Masculina , Atención Primaria de Salud , Parejas Sexuales , Estudios Transversales , Femenino , Infecciones por VIH/diagnóstico , Infecciones por VIH/prevención & control , Infecciones por VIH/transmisión , Humanos , Internet , Masculino , Persona de Mediana Edad , Atención Primaria de Salud/métodos , Factores de Riesgo , Conducta Sexual , Encuestas y Cuestionarios
17.
AIDS Behav ; 22(1): 117-126, 2018 01.
Artículo en Inglés | MEDLINE | ID: mdl-29058163

RESUMEN

In the United States, an estimated 67% of new HIV diagnoses are among men who have sex with men (MSM), however 25% of HIV-positive MSM in the 2014 National HIV Behavioral Surveillance Survey were unaware of their infection. HIV self-testing (HIVST) with rapid diagnostic tests (RDTs) may facilitate access to HIV testing. We evaluated the ability of 22 MSM to conduct two HIV RDTs (OraQuick ® In-Home HIV Test and a home-use prototype of Sure Check ® HIV 1/2 Assay), interpret sample images of test results, and collect a dried blood spot (DBS) specimen. While some participants did not follow every direction, most participants were able to conduct HIVST and correctly interpret their results. Interpretation of panels of RDT images was especially difficult when the "control" line was missing, and 27% of DBS cards produced were rated as of bad quality. Modifications to the DBS instructions were necessary prior to evaluating the performance of these tests in real-world settings.


Asunto(s)
Serodiagnóstico del SIDA , Infecciones por VIH/diagnóstico , Homosexualidad Masculina , Tamizaje Masivo/métodos , Autocuidado , Adulto , Pruebas con Sangre Seca , Georgia , Infecciones por VIH/prevención & control , Humanos , Masculino , Proyectos Piloto
18.
19.
J Clin Virol ; 91: 84-89, 2017 06.
Artículo en Inglés | MEDLINE | ID: mdl-28366544

RESUMEN

OBJECTIVE: FDA-approved antigen/antibody combo and HIV-1/2 differentiation supplemental tests do not have claims for dried blood spot (DBS) use. We compared two DBS-modified protocols, the Bio-Rad GS HIV Combo Ag/Ab (BRC) EIA and Geenius™ HIV-1/2 (Geenius) Supplemental Assay, to plasma protocols and evaluated them in the CDC/APHL HIV diagnostic algorithm. METHODS: BRC-DBS p24 analytical sensitivity was calculated from serial dilutions of p24. DBS specimens included 11 HIV-1 seroconverters, 151 HIV-1-positive individuals, including 20 on antiretroviral therapy, 31 HIV-2-positive and one HIV-1/HIV-2-positive individuals. BRC-reactive specimens were tested with Geenius using the same DBS eluate. Matched plasma specimens were tested with BRC, an IgG/IgM immunoassay and Geenius. DBS and plasma results were compared using the McNemar's test. A DBS-algorithm applied to 348 DBS from high-risk individuals who participated in surveillance was compared to HIV status based on local testing algorithms. RESULTS: BRC-DBS detects p24 at a concentration 18 times higher than in plasma. In seroconverters, BRC-DBS detected more infections than the IgG/IgM immunoassay in plasma (p=0.0133), but fewer infections than BRC-plasma (p=0.0133). In addition, the BRC/Geenius-plasma algorithm identified more HIV-1 infections than the BRC/Geenius-DBS algorithm (p=0.0455). The DBS protocols correctly identified HIV status for established HIV-1 infections, including those on therapy, HIV-2 infections, and surveillance specimens. CONCLUSIONS: The DBS protocols exhibited promising performance and allowed rapid supplemental testing. Although the DBS algorithm missed some early infections, it showed similar results when applied to specimens from a high-risk population. Implementation of a DBS algorithm would benefit testing programs without capacity for venipuncture.


Asunto(s)
Pruebas con Sangre Seca , Infecciones por VIH/diagnóstico , Técnicas para Inmunoenzimas , Serodiagnóstico del SIDA , Algoritmos , Pruebas con Sangre Seca/instrumentación , Pruebas con Sangre Seca/métodos , Monitoreo Epidemiológico , Anticuerpos Anti-VIH/sangre , Antígenos VIH/sangre , Antígenos VIH/inmunología , Infecciones por VIH/sangre , Infecciones por VIH/inmunología , Infecciones por VIH/virología , VIH-1/inmunología , VIH-2/inmunología , Humanos , ARN Viral/sangre , Juego de Reactivos para Diagnóstico , Factores de Riesgo , Sensibilidad y Especificidad
20.
J Clin Virol ; 91: 90-94, 2017 06.
Artículo en Inglés | MEDLINE | ID: mdl-28372890

RESUMEN

BACKGROUND: The flow-through INSTI™ HIV-1/HIV-2 Rapid Antibody (INSTI) test is a 60s FDA-approved test for HIV-1 and HIV-2 antibody testing using whole blood and plasma. OBJECTIVE: We evaluated the performance of INSTI using plasma and simulated whole blood specimens. STUDY DESIGN: INSTI's performance in plasma specimens from commercial seroconversion panels was assessed by estimating the relative sensitivity using a 50% cumulative frequency analysis and by comparing its performance with other FDA-approved rapid tests (RTs). INSTI was further evaluated using 320 HIV-1 plasma specimens collected during a cross-sectional study and with 107 HIV-1 and 24 HIV-2 simulated whole blood specimens. Sensitivity and specificity were calculated using 615 known HIV-1 group M/O and 80 HIV-2 (Western blot (WB)-positive), and 497 HIV-negative plasma specimens, respectively. RESULTS: In HIV-1 seroconversion panels, INSTI became reactive 9days before a positive WB. When compared to FDA-approved antibody-based lateral flow RTs, INSTI detected significantly more early infections. Among HIV-1-infected cross-sectional plasma samples, INSTI detected 23 (27%) of 85 Architect-positive/Multispot-negative or indeterminate specimens. For plasma specimens, the sensitivity was 99.84% for HIV-1 and 100% for HIV-2, and the specificity was 99.80%. Using simulated whole blood from seroconverters, INSTI performed similarly to plasma. CONCLUSIONS: INSTI performed significantly better than antibody-based lateral flow RTs during early stages of seroconversion. Sensitivity and specificity were within the manufacturer's reported ranges. Considering the observed test performance and the almost immediate results, INSTI is an accurate option to detect HIV-1/HIV-2 antibodies in point-of-care settings where lab testing is not feasible.


Asunto(s)
Serodiagnóstico del SIDA , Anticuerpos Anti-VIH/sangre , Infecciones por VIH/diagnóstico , Sistemas de Atención de Punto , Algoritmos , Western Blotting , Estudios Transversales , Anticuerpos Anti-VIH/aislamiento & purificación , Infecciones por VIH/tratamiento farmacológico , Infecciones por VIH/inmunología , VIH-1/inmunología , VIH-2/inmunología , Humanos , Tamizaje Masivo , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA