Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 35
Filtrar
1.
J Invasive Cardiol ; 33(10): E761-E768, 2021 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-34521771

RESUMEN

OBJECTIVES: To assess the impact of balloon use for predilation, valve implantation, or postdilation on in-hospital mortality among patients undergoing transcatheter aortic valve replacement (TAVR). BACKGROUND: TAVR utilizes self-expanding, mechanically expanding, or balloon-expandable valves. Balloon inflation is inherent to deployment of balloon-expandable valves. Balloons may additionally be used with all valve types for pre- and postdilation. The relationships between valve mechanism, balloon use, and in-hospital mortality are not fully characterized. METHODS: Prospective data were collected on 4063 patients undergoing TAVR for aortic stenosis at 4 high-volume centers in the United Kingdom. In-hospital mortality was analyzed according to valve expansion mechanism, use of balloons for pre- and postdilation, and specific cause of death. RESULTS: Mean patient age was 83 ± 8 years. Implanted valves were self expanding (n = 2241; 55%), mechanically expanding (n = 1092; 27%), or balloon expandable (n = 727; 18%). In-hospital death occurred in 66 cases (1.6%). Thirty-six deaths (54.5%) were classified as implantation-related mortalities, with rates of 0.8%, 0.5%, and 1.7% (P=.04) among self-expanding, mechanically expanding, and balloon-expandable technologies, respectively. Patients who underwent balloon inflation at any stage of their procedure (n = 2556; 63%) had significantly higher implantation-related mortality than those who did not (1.3% vs 0.3%, respectively; P<.01). Balloon-expandable valve procedures were associated with significantly higher all-cause mortality (2.6% vs 1.4%; P=.02) and implantation-related mortality (1.7% vs 0.7%; P=.02) than non-balloon-expandable valve procedures. Balloon-related complications accounted for 18 cases (26%) of total in-hospital mortality, including all 12 cases (17.4%) of annular rupture and 5 cases (7.2%) of coronary occlusion. CONCLUSIONS: Balloon use for predilation, valve implantation, or postdilation was associated with an increased mortality risk. Balloon-related complications were the largest contributor to in-hospital mortality, comprising all cases of annular rupture and the majority of coronary occlusion cases.


Asunto(s)
Estenosis de la Válvula Aórtica , Valvuloplastia con Balón , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/cirugía , Valvuloplastia con Balón/efectos adversos , Prótesis Valvulares Cardíacas/efectos adversos , Mortalidad Hospitalaria , Humanos , Estudios Prospectivos , Diseño de Prótesis , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
2.
Acta Cardiol ; 75(3): 218-225, 2020 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-30931804

RESUMEN

Background: Transcatheter aortic valve implantation (TAVI) is an established therapy for patients with severe aortic stenosis (AS). There is limited data exploring differences in outcomes post-TAVI SEV vs. BEV. This study compared procedural success and 30-d clinical outcomes self-expandable valves (SEV), vs. balloon-expandable valves (BEV) for patients with severe AS.Methods: Retrospective analysis was undertaken of patients receiving TAVI at St Vincent's Hospital, Melbourne between August 2009 and May 2018. The primary endpoints included procedural success, clinical outcomes and complication rates at 30-d.Results: Out of 151 patients undergoing TAVI, 70 received (46.3%) SEV (Medtronic CoreValve & Evolut-R) and 81 (53.6%) BEV (Edwards SAPIEN-XT & S3). The mean Society of Thoracic Surgery (STS) risk score did not differ between the groups, SEV (83.6 ± 4.9 years, STS 4.4 ± 3.8) compared to BEV (82.3 ± 5.8 years, STS 4.9 ± 4.9). Procedural success was similar SEV 67 (95.7%) vs. BEV 78 (96.3%). Rates of ≥ moderate paravalvular aortic regurgitation (PAR) at 30-d were significantly higher in SEV compared to BEV (6.7 vs. 0.0%; p = .02). SEV patients had higher rates of pacemaker insertion (36.4 vs. 9.5%; p = .001) and stroke rates (12.4 vs. 1.4%; p = .04) compared to BEV patients. The difference in 30-d mortality between the two groups was similar (SEV 4.6% vs. BEV 1.3%; p = .23).Conclusions: This real-world retrospective analysis demonstrates higher rates of ≥ moderate PAR, stroke and pacemaker insertion with SEV compared to BEV at 30 d post-TAVI for severe symptomatic AS.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Estenosis de la Válvula Aórtica , Válvula Aórtica , Prótesis Valvulares Cardíacas , Marcapaso Artificial/estadística & datos numéricos , Complicaciones Posoperatorias , Accidente Cerebrovascular , Reemplazo de la Válvula Aórtica Transcatéter , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Insuficiencia de la Válvula Aórtica/diagnóstico , Insuficiencia de la Válvula Aórtica/epidemiología , Insuficiencia de la Válvula Aórtica/etiología , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/epidemiología , Estenosis de la Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/cirugía , Australia/epidemiología , Femenino , Prótesis Valvulares Cardíacas/efectos adversos , Prótesis Valvulares Cardíacas/estadística & datos numéricos , Humanos , Masculino , Evaluación de Procesos y Resultados en Atención de Salud , Complicaciones Posoperatorias/diagnóstico , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/etiología , Diseño de Prótesis/métodos , Estudios Retrospectivos , Índice de Severidad de la Enfermedad , Accidente Cerebrovascular/diagnóstico , Accidente Cerebrovascular/epidemiología , Accidente Cerebrovascular/etiología , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Reemplazo de la Válvula Aórtica Transcatéter/métodos
3.
Aust J Rural Health ; 27(3): 229-236, 2019 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-31074928

RESUMEN

OBJECTIVE: To compare clinical and functional outcomes of regional and urban patients after transcatheter aortic valve implantation for severe aortic stenosis. METHODS: Data were collected at patient follow-up post-transcatheter aortic valve implantation at 30 days and 12 months. Patients were stratified by residential postcodes into remoteness areas using the Australian Statistical Geography Standard. DESIGN: Retrospective cohort study. SETTING: Single-centre tertiary referral hospital. PARTICIPANTS: Patients undergoing transcatheter aortic valve implantation (n = 142) from 2009 to 2018 were analysed, with 77 patients (54.2%) residing in regional Victoria and New South Wales. MAIN OUTCOME MEASURES: Procedural success, adverse event rates, readmission rates, mortality rates, loss to follow-up and functional improvement. RESULTS: Patients residing in regional areas had a lower mean age (81.8 vs 83.7 years) and proportion of Stage 4 or 5 chronic kidney disease (1.3% vs 9.2%), compared with urban patients. Procedural characteristics and immediate post-procedural outcomes were similar between both groups. There was no statistically significant difference in mortality, readmission rates or loss to follow-up between the two cohorts. Regional patients demonstrated poorer rates of functional improvement at 30 days (50.7% vs 67.7%); however, this difference was not sustained at 12 months (79.2% vs 71.0%). Frailty was demonstrated to be an independent predictor of poor 30-day functional improvement. CONCLUSION: Regional patients treated with transcatheter aortic valve implantation for severe aortic stenosis have non-inferior 30-day and 12-month outcomes, when compared with urban patients. Frailty is a predictor of poor functional improvement post-transcatheter aortic valve implantation.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/fisiopatología , Femenino , Humanos , Masculino , Nueva Gales del Sur , Evaluación de Resultado en la Atención de Salud/métodos , Indicadores de Calidad de la Atención de Salud , Estudios Retrospectivos , Población Rural , Índice de Severidad de la Enfermedad , Victoria
4.
J Med Imaging Radiat Oncol ; 63(4): 446-453, 2019 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-30874377

RESUMEN

INTRODUCTION: Patients with severe aortic stenosis (AS) require multi-detector computed tomography (MDCT) when considered for transcatheter aortic valve implantation (TAVI). Incidental findings on MDCT are common given the age group and region imaged. Our aim was to evaluate the frequency and outcome of incidental findings (IF) identified on MDCT and the impact on survival. METHODS: This single-centre analysis retrospectively reviewed severe AS patients who underwent MDCT during TAVI workup. MDCT reports were reviewed for any IF and defined into three categories: IF of no relevant clinical significance (IF-NoCS), IF of non-immediate clinical significance (IF-NICS) and IF of immediate clinical significance (IF-ICS). Demographics, follow-up of IF and survival were calculated from MDCT date. RESULTS: Two hundred and sixty-five patients underwent MDCT for TAVI suitability (mean age 83 ± 6 years, 52% male). The majority proceeded to TAVI (65%). Renal lesions (25%) and lung nodules (18%) were the most common IF. Fifty-nine patients (22%) had IF-NICS; 39% (23/59) were benign, 59% were not further investigated and one patient had suspected lung cancer. Six patients (2.3%) had IF-ICS and all were diagnosed with lung cancer. During a median follow-up of 272 days, there was no survival difference between patients with IF-ICS or IF-NICS versus patients without IF or IF-NoCS in the overall cohort (P = 0.44) or in TAVI patients (P = 0.88). CONCLUSION: Incidental findings on MDCT are common with one-quarter having IF-ICS or IF-NCIS. Most patients with IF-NICS did not undergo further investigation. Standardized reporting of MDCT may assist in clarifying the need for further investigation which will in turn influence decision and timing to proceed with TAVI.


Asunto(s)
Estenosis de la Válvula Aórtica/diagnóstico por imagen , Hallazgos Incidentales , Tomografía Computarizada Multidetector/métodos , Cuidados Preoperatorios/métodos , Reemplazo de la Válvula Aórtica Transcatéter , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Estudios de Cohortes , Femenino , Humanos , Masculino , Estudios Retrospectivos , Análisis de Supervivencia
5.
Intern Med J ; 49(3): 297-305, 2019 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-30091235

RESUMEN

Severe aortic stenosis (AS) is the most common form of valvular heart disease in the developed world, with a rising prevalence due to an ageing Australian population. Transcatheter aortic valve implantation (TAVI) offers a less invasive option for the treatment of severe AS, with evidence supporting TAVI compared with medical therapy in inoperable patients and superior with surgical aortic valve replacement (SAVR) in high-risk patients. Equal outcomes have been observed in all-comer intermediate-risk populations. The Heart Team utilises a shared decision-making approach between physicians and surgeons in risk-stratifying patients and reduces the intrinsic bias that may occur if decisions are made in isolation. Geriatric assessment is useful for identifying preoperative frailty, a major risk factor for death post-aortic valve intervention. In severe AS, a decision can be made collaboratively to pursue TAVI, SAVR, a Ross Procedure or conservative management. The learning curve associated with TAVI has improved markedly, with overall complication rates decreasing around the world. Contemporary changes in practice, such as conscious sedation without general anaesthesia, expedited recovery and early discharge, will likely improve cost-effectiveness. In 2018, TAVI is a well-established procedure in Australia that has revolutionised the management of severe AS. In the future, with an expanding elderly population, the number of patients to benefit from transcatheter therapies for severe AS is hypothesised to increase 4-10-fold. Heart Team assessment is crucial in patients with severe AS to direct appropriate management.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Prótesis Valvulares Cardíacas , Grupo de Atención al Paciente , Complicaciones Posoperatorias/epidemiología , Reemplazo de la Válvula Aórtica Transcatéter/tendencias , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/mortalidad , Australia , Análisis Costo-Beneficio , Toma de Decisiones , Salud Global , Humanos , Medición de Riesgo , Factores de Riesgo
7.
Cardiovasc Revasc Med ; 19(8): 917-922, 2018 12.
Artículo en Inglés | MEDLINE | ID: mdl-29709534

RESUMEN

BACKGROUND: In this prospective study, we compared the invasive measures of microvascular function in two subsets: patients with pharmacoinvasive thrombolysis for STEMI, and patients undergoing percutaneous coronary intervention (PCI) for NSTEMI. METHODS: The study consisted of 17 patients with STEMI referred for cardiac catheterisation post thrombolysis, and 20 patients with NSTEMI. Coronary physiological indexes were measured in each patient before and after PCI. RESULTS: The median pre-PCI index of microcirculatory function (IMR) at baseline was significantly higher in the STEMI group than the NSTEMI group (26 units vs. 15 units, p = 0.02). Following PCI, IMR decreased in both groups (STEMI 20 units vs. NSTEMI 14 units, p = 0.10). There was an inverse correlation between post PCI IMR and left ventricular ejection fraction (LVEF) (r = -0.52, p = 0.001). Furthermore, post PCI IMR was an independent predictor of index admission LVEF in the total population (ß = -0.388, p = 0.02). CONCLUSION: Invasive measures of microvascular function are inferior in a pharmacoinvasive STEMI group compared to a clinically stable NSTEMI group. In the STEMI population, the IMR following coronary intervention appears to predict LVEF.


Asunto(s)
Circulación Coronaria/fisiología , Vasos Coronarios/fisiopatología , Infarto del Miocardio sin Elevación del ST/fisiopatología , Intervención Coronaria Percutánea/métodos , Infarto del Miocardio con Elevación del ST/fisiopatología , Terapia Trombolítica/métodos , Resistencia Vascular/fisiología , Aspirina/uso terapéutico , Cateterismo Cardíaco , Clopidogrel/uso terapéutico , Ecocardiografía , Femenino , Ventrículos Cardíacos/diagnóstico por imagen , Ventrículos Cardíacos/fisiopatología , Humanos , Masculino , Microcirculación/fisiología , Persona de Mediana Edad , Infarto del Miocardio sin Elevación del ST/diagnóstico , Infarto del Miocardio sin Elevación del ST/cirugía , Inhibidores de Agregación Plaquetaria/uso terapéutico , Estudios Prospectivos , Infarto del Miocardio con Elevación del ST/diagnóstico , Infarto del Miocardio con Elevación del ST/tratamiento farmacológico , Resultado del Tratamiento , Función Ventricular Izquierda/fisiología
8.
Catheter Cardiovasc Interv ; 91(3): 387-395, 2018 02 15.
Artículo en Inglés | MEDLINE | ID: mdl-28471086

RESUMEN

OBJECTIVES: to compare the occurrence of clinical events in diabetics treated with the Absorb bioresorbable vascular scaffold (Absorb BVS; Abbott Vascular, Santa Clara, CA) versus everolimus-eluting metal stents (EES; XIENCE V; Abbott Vascular, Santa Clara, CA) BACKGROUND: There are limited data dedicated to clinical outcomes of diabetic patients treated with bioresorbable scaffolds (BRS) at 2-year horizon. METHODS: The present study included 812 patients in the ABSORB EXTEND study in which a total of 215 diabetic patients were treated with Absorb BVS. In addition, 882 diabetic patients treated with EES in pooled data from the SPIRIT clinical program (SPIRIT II, SPIRIT III and SPIRIT IV trials) were used for comparison by applying propensity score matching using 29 different variables. The primary endpoint was ischemia driven major adverse cardiac events (ID-MACE), including cardiac death, myocardial infarction (MI), and ischemia driven target lesion revascularization (ID-TLR). RESULTS: After 2 years, the ID-MACE rate was 6.5% in the Absorb BVS vs. 8.9% in the Xience group (P = 0.40). There was no difference for MACE components or definite/probable device thrombosis (HR: 1.43 [0.24,8.58]; P = 0.69). The occurrence of MACE was not different for both diabetic status (insulin- and non-insulin-requiring diabetes) in all time points up to the 2-year follow-up for the Absorb and Xience groups. CONCLUSION: In this largest ever patient-level pooled comparison on the treatment of diabetic patients with BRS out to two years, individuals with diabetes treated with the Absorb BVS had a similar rate of MACE as compared with diabetics treated with the Xience EES. © 2017 Wiley Periodicals, Inc.


Asunto(s)
Implantes Absorbibles , Angioplastia Coronaria con Balón/instrumentación , Fármacos Cardiovasculares/administración & dosificación , Enfermedad de la Arteria Coronaria/cirugía , Diabetes Mellitus , Stents Liberadores de Fármacos , Everolimus/administración & dosificación , Anciano , Angioplastia Coronaria con Balón/efectos adversos , Angioplastia Coronaria con Balón/mortalidad , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/mortalidad , Diabetes Mellitus/diagnóstico , Diabetes Mellitus/tratamiento farmacológico , Diabetes Mellitus/mortalidad , Femenino , Humanos , Hipoglucemiantes/uso terapéutico , Insulina/uso terapéutico , Masculino , Persona de Mediana Edad , Puntaje de Propensión , Diseño de Prótesis , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
9.
Atherosclerosis ; 262: 94-100, 2017 07.
Artículo en Inglés | MEDLINE | ID: mdl-28531827

RESUMEN

BACKGROUND AND AIMS: Catheter-based renal denervation for the treatment of drug-resistant hypertension has been intensively investigated in recent years. To date, only limited data have been published using multi-electrode radiofrequency ablation systems that can deliver lesions with a pre-determined pattern. This study was designed to evaluate the safety and performance of the second generation EnligHTN™ Renal Denervation System. METHODS: This first-in-human, prospective, multi-center, non-randomized study included 39 patients (62% male, mean age 63 years, and mean baseline office blood pressure 174/93 mmHg) with drug-resistant hypertension. The primary safety and performance objectives were to characterize, from baseline to 6 months post procedure, the rate of serious procedural and device related adverse events, as adjudicated by an independent Clinical Events Committee, and the reduction of office systolic blood pressure. RESULTS: Renal artery denervation, using the second generation EnligHTN multi-electrode system significantly reduced office blood pressure from baseline to 1, 3, 6, 12, 18 and 24 months by 19/7, 26/9, 25/7, 23/7, 25/8 and 27/9 mmHg, respectively (p ≤ 0.0005). No serious device or procedure related adverse events affecting the renal arteries or renal function occurred through 24 months of follow-up. CONCLUSIONS: Renal sympathetic denervation using the second generation EnligHTN Renal Denervation System resulted in safe, rapid, and significant mean office blood pressure reduction that was sustained through 24 months. Future studies will need to address the utility of this system against an appropriate sham based comparator.


Asunto(s)
Presión Sanguínea , Ablación por Catéter/instrumentación , Hipertensión/cirugía , Riñón/irrigación sanguínea , Arteria Renal/inervación , Simpatectomía/instrumentación , Sistema Nervioso Simpático/cirugía , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Antihipertensivos/uso terapéutico , Australia , Presión Sanguínea/efectos de los fármacos , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Resistencia a Medicamentos , Femenino , Humanos , Hipertensión/diagnóstico , Hipertensión/fisiopatología , Masculino , Persona de Mediana Edad , Nueva Zelanda , Estudios Prospectivos , Simpatectomía/efectos adversos , Simpatectomía/métodos , Sistema Nervioso Simpático/fisiopatología , Factores de Tiempo , Resultado del Tratamiento , Adulto Joven
10.
JACC Cardiovasc Interv ; 9(4): 376-384, 2016 Feb 22.
Artículo en Inglés | MEDLINE | ID: mdl-26892084

RESUMEN

OBJECTIVES: This analysis presents the first report of 1-year outcomes of the 120 patients enrolled in the REPRISE II (Repositionable Percutaneous Placement of Stenotic Aortic Valve Through Implantation of Lotus Valve System-Evaluation of Safety and Performance) study. BACKGROUND: The fully repositionable and retrievable Lotus Valve (Boston Scientific, Marlborough, Massachusetts) was designed to facilitate accurate positioning, early valve function, and hemodynamic stability during deployment and to minimize paravalvular regurgitation in patients undergoing transcatheter aortic valve replacement. METHODS: The study enrolled 120 symptomatic patients 70 years of age or older at 14 centers in Australia and Europe. Patients had severe calcific aortic stenosis and were deemed to be at high or extreme risk of surgery based on assessment by the heart team. RESULTS: The mean age was 84.4 ± 5.3 years, 57% (68 of 120) of patients were women, and the mean Society of Thoracic Surgeons score was 7.1 ± 4.6. The mean baseline aortic valve area was 0.7 ± 0.2 cm(2), and the mean transvalvular pressure gradient was 46.4 ± 15.0 mm Hg. All patients were successfully implanted with a Lotus Valve, and 1-year clinical follow-up was available for 99.2% (119 of 120 of patients). The mean 1-year transvalvular aortic pressure gradient was 12.6 ± 5.7 mm Hg, and the mean valve area was 1.7 ± 0.5 cm(2). A total of 88.6% patients had no or trivial paravalvular aortic regurgitation at 1 year by independent core lab adjudication, and 97.1% of patients were New York Heart Association functional class I or II. At 1 year, the all-cause mortality rate was 10.9% (13 of 119 patients), disabling stroke rate was 3.4% (4 of 119 patients), disabling bleeding rate was 5.9% (7 of 119 patients), with no repeat procedures for valve-related dysfunction. A total of 31.9% (38 of 119 patients) underwent new permanent pacemaker implantation at 1 year. CONCLUSIONS: At 1 year of follow-up, the Lotus Valve demonstrated excellent valve hemodynamics, no moderate or severe paravalvular regurgitation, and significant and sustained improvement in New York Heart Association functional class status, with good clinical outcomes. (Repositionable Percutaneous Placement of Stenotic Aortic Valve Through Implantation of Lotus Valve System-Evaluation of Safety and Performance [REPRISE II]; NCT01627691).


Asunto(s)
Estenosis de la Válvula Aórtica/terapia , Válvula Aórtica/patología , Calcinosis/terapia , Cateterismo Cardíaco/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Prótesis Valvulares Cardíacas , Anciano , Anciano de 80 o más Años , Válvula Aórtica/fisiopatología , Insuficiencia de la Válvula Aórtica/etiología , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/fisiopatología , Arritmias Cardíacas/etiología , Arritmias Cardíacas/terapia , Australia , Calcinosis/diagnóstico , Calcinosis/mortalidad , Calcinosis/fisiopatología , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/mortalidad , Estimulación Cardíaca Artificial , Europa (Continente) , Femenino , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Hemodinámica , Humanos , Masculino , Estudios Prospectivos , Diseño de Prótesis , Factores de Riesgo , Índice de Severidad de la Enfermedad , Factores de Tiempo , Resultado del Tratamiento
11.
J Interv Cardiol ; 29(2): 146-54, 2016 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-26822384

RESUMEN

BACKGROUND: The index of microcirculatory resistance (IMR), an invasive measure of microvascular function, has been shown to correlate with clinical outcomes in patients with ST-segment elevation myocardial infarction (STEMI). The aim of this study is to evaluate the predictive value of IMR on left ventricular recovery in patients undergoing a pharmacoinvasive strategy for STEMI. METHODS: The index of microcirculatory resistance was assessed following percutaneous coronary intervention (PCI) in 31 patients with STEMI who were initially managed with thrombolysis. Other markers of microvascular function such as coronary flow reserve (CFR), TIMI flow grade, corrected TIMI frame count (cTFC), and ST-segment resolution were also recorded. All indices were evaluated against measures of left ventricular function and recovery 3 months postindex event. RESULTS: The IMR correlated with left ventricular function, as assessed by wall motion score and ejection fraction at 3-month follow-up (r = 0.652, P = 0.005; r = -0.452, P = 0.011, respectively). The traditional methods of assessing microvascular function, such as CFR, TIMI flow grade, cTFC, and ST-segment resolution did not correlate with wall motion score and ejection fraction at 3 months. Post-PCI IMR was significantly lower in those patients with left ventricular recovery at 3 months (18 U vs 39 U, P < 0.001). The optimal cut-off value for post-PCI IMR and left ventricular recovery was 32 U. In patients in whom the IMR was greater than 32 U, the percent change in ejection fraction was significantly lower than in those patients in whom the IMR was less than 32 U (2 ± 11 vs 12 ± 8, P = 0.012). CONCLUSIONS: In patients presenting with STEMI initially managed with thrombolysis and subsequently undergoing PCI, IMR correlates with measures of left ventricular function and has the potential to predict left ventricular recovery at 3 months.


Asunto(s)
Ventrículos Cardíacos/fisiopatología , Microcirculación/fisiología , Infarto del Miocardio/fisiopatología , Intervención Coronaria Percutánea/métodos , Función Ventricular Izquierda/fisiología , Anciano , Biomarcadores , Femenino , Humanos , Masculino , Persona de Mediana Edad , Infarto del Miocardio/cirugía , Intervención Coronaria Percutánea/efectos adversos , Proyectos Piloto , Terapia Trombolítica/métodos
12.
J Invasive Cardiol ; 27(3): 129-36, 2015 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-25740963

RESUMEN

OBJECTIVES: The RESPECT trial was aimed at evaluating safety/efficacy of a new extravascular closure system in diagnostic (Dx) and interventional (Ix) procedures performed through 6 or 7 Fr introducer sheaths. BACKGROUND: Although vascular closure devices (VCDs) have been available for two decades, manual compression (MC) remains the standard of care in many institutions. VCDs have not been shown to have greater safety than MC. METHODS: The RESPECT trial was a multicenter, randomized comparison of the Vascade VCD (Cardiva Medical, Inc) versus MC in Dx and Ix patients undergoing femoral access. Endpoints included time to hemostasis (TTH), time to ambulation (TTA), time to discharge eligibility (TTDe), device and procedure success, major and minor complications. Subjects were randomized 2:1 (Vascade vs MC). RESULTS: A total of 420 patients were enrolled (211 Dx, 209 Ix). Mean age was 62 ± 11 years and 29% were female. For Ix Vascade/MC patients, 77%/69% received bivalirudin, 27%/26% received heparin, and 8%/3% received glycoprotein IIb/IIIa inhibitors, respectively. Patients were followed for 30 ± 7 days. A total of 415 subjects (98.8%) completed follow-up. TTH was 3.0 minutes (range, 0.6-31.6 minutes) for Vascade vs 20.0 minutes (range, 0.0-97.0 minutes) for MC; TTA was 3.2 hours (range, 1.0-78.0 hours) for Vascade vs. 5.2 hours (range, 1.7-22.8 hours) for MC; and TTDe was 3.6 hours (range, 1.4-78.4 hours) for Vascade vs. 5.7 hours (range, 2.2-23.2 hours) for MC. Device and procedure success rates were 98% for Vascade and 100% for MC. Minor events were 1.1% for Vascade and 7% for MC. No major access-site related complications were reported in either arm. CONCLUSION: Despite high percentage of bivalirudin use, there were no major access-site related complications in either arm. Vascade use reduced rates of minor access-site related complications, and significantly shortened TTH, TTA, and TTDe compared to MC.


Asunto(s)
Cateterismo Cardíaco/efectos adversos , Colágeno/farmacología , Procedimientos Endovasculares/instrumentación , Arteria Femoral/lesiones , Hemorragia/cirugía , Técnicas Hemostáticas/instrumentación , Adulto , Anciano , Anciano de 80 o más Años , Diseño de Equipo , Femenino , Estudios de Seguimiento , Hemorragia/etiología , Humanos , Masculino , Persona de Mediana Edad , Presión , Estudios Prospectivos
13.
J Am Coll Cardiol ; 64(13): 1339-48, 2014 Sep 30.
Artículo en Inglés | MEDLINE | ID: mdl-25257635

RESUMEN

BACKGROUND: Transcatheter aortic valve replacement provides results comparable to those of surgery in patients at high surgical risk, but complications can impact long-term outcomes. The Lotus valve, designed to improve upon earlier devices, is fully repositionable and retrievable, with a unique seal to minimize paravalvular regurgitation (PVR). OBJECTIVES: The prospective, single-arm, multicenter REPRISE II study (REpositionable Percutaneous Replacement of Stenotic Aortic Valve Through Implantation of Lotus Valve System: Evaluation of Safety and Performance) evaluated the transcatheter valve system for treatment of severe symptomatic calcific aortic valve stenosis. METHODS: Patients (n = 120; aortic annulus 19 to 27 mm) considered by a multidisciplinary heart team to be at high surgical risk received the valve transfemorally. The primary device performance endpoint, 30-day mean pressure gradient, was assessed by an independent echocardiographic core laboratory and compared with a pre-specified performance goal. The primary safety endpoint was 30-day mortality. Secondary endpoints included safety/effectiveness metrics per Valve Academic Research Consortium criteria. RESULTS: Mean age was 84.4 years, 57% of the patients were female, and 76% were New York Heart Association functional class III/IV. Mean aortic valve area was 0.7 ± 0.2 cm(2). The valve was successfully implanted in all patients, with no cases of valve embolization, ectopic valve deployment, or additional valve implantation. All repositioning (n = 26) and retrieval (n = 6) attempts were successful; 34 patients (28.6%) received a permanent pacemaker. The primary device performance endpoint was met, because the mean gradient improved from 46.4 ± 15.0 mm Hg to 11.5 ± 5.2 mm Hg. At 30 days, the mortality rate was 4.2%, and the rate of disabling stroke was 1.7%; 1 (1.0%) patient had moderate PVR, whereas none had severe PVR. CONCLUSIONS: REPRISE II demonstrates the safety and effectiveness of the Lotus valve in patients with severe aortic stenosis who are at high surgical risk. The valve could be positioned successfully with minimal PVR. (REPRISE II: REpositionable Percutaneous Replacement of Stenotic Aortic Valve Through Implantation of Lotus™ Valve System - Evaluation of Safety and Performance; NCT01627691).


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/terapia , Implantación de Prótesis de Válvulas Cardíacas/métodos , Prótesis Valvulares Cardíacas , Anciano , Anciano de 80 o más Años , Válvula Aórtica/patología , Válvula Aórtica/cirugía , Calcinosis/cirugía , Calcinosis/terapia , Diseño de Equipo , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Riesgo , Resultado del Tratamiento
15.
EuroIntervention ; 9(11): 1264-70, 2014 Mar 20.
Artículo en Inglés | MEDLINE | ID: mdl-24169077

RESUMEN

AIMS: To assess outcomes with a new fully repositionable and retrievable valve for transcatheter aortic valve replacement (TAVR). METHODS AND RESULTS: The Lotus Aortic Valve System is designed to facilitate precise positioning and minimise paravalvular regurgitation. REPRISE I enrolled symptomatic, high-surgical-risk patients with severe aortic stenosis. The primary endpoint (clinical procedural success) included successful implantation without major adverse cardiovascular or cerebrovascular events (MACCE). In all patients (N=11) the first Lotus Valve was successfully deployed. Partial resheathing to facilitate accurate placement was attempted and successfully performed in four patients; none required full retrieval. The primary endpoint was achieved in 9/11 with no in-hospital MACCE in 10/11. There was one major stroke; in another patient, discharge mean aortic gradient was 22 mmHg (above the primary endpoint threshold of 20 mmHg), but improved to 15 mmHg at 30 days. The cohort's mean aortic gradient decreased from 53.9±20.9 mmHg at baseline to 15.4±4.6 mmHg (p<0.001) at one year; valve area increased from 0.7±0.2 cm2 to 1.5±0.2 cm2 (p<0.001). Discharge paravalvular aortic regurgitation, adjudicated by an independent core laboratory, was mild (n=2), trivial (n=1), or absent (n=8). Four patients required a permanent pacemaker post-procedure. There were no deaths, myocardial infarctions or new strokes through one year. CONCLUSIONS: Initial results support proof-of-concept with the Lotus Valve for TAVR.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Bioprótesis , Implantación de Prótesis de Válvulas Cardíacas/métodos , Prótesis Valvulares Cardíacas , Anciano , Anciano de 80 o más Años , Ecocardiografía , Femenino , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Humanos , Masculino , Marcapaso Artificial , Estudios Prospectivos , Riesgo
16.
Eur J Cardiovasc Nurs ; 13(5): 408-17, 2014 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-23969781

RESUMEN

BACKGROUND: Screening for self-care capacity is advocated before applying educational strategies. No screening tool has been specifically developed to assess barriers that impede engagement in self-care in people with heart failure. Earlier conceptual work (InCOGNITO) identified NYHA class, mild cognitive impairment and depressive symptoms as barriers that impede engagement in HF self-care. AIMS: Study aims were: 1) to develop the Heart Failure Screening Tool (Heart-FaST) as a means of assessing three critical barriers to self-care; 2) to assess the content validity of the Heart-FaST; and 3) to test the feasibility of implementing the Heart-FaST in clinical practice. METHODS: The Heart-FaST was developed from barriers identified in previous research (InCOGNITO) and from expert panel consensus. Content validity was assessed by examining the proportion of experts who scored each item as relevant. RESULTS: The InCOGNITO study indicated that four cognitive tasks, seven emotional questions and NYHA functional class were significantly correlated with the self-care scales: maintenance, management and confidence. These factors were used to create the Heart-FaST items. Consensus on wording and items to be included in the Heart-FaST was reached after two rounds of panel discussion. All items had an item-level content validity index ≥ 0.78. High scores on each barrier (physical, cognitive and emotional functioning) suggest poor self-care and the need for more intensive disease management efforts. CONCLUSION: The Heart-FaST measures three critical barriers that impede engagement in self-care. In clinical practice this tool may assist in individually tailoring educational and support strategies to promote effective heart failure self-care.


Asunto(s)
Disfunción Cognitiva/diagnóstico , Insuficiencia Cardíaca/enfermería , Tamizaje Masivo/instrumentación , Tamizaje Masivo/psicología , Autocuidado/instrumentación , Adulto , Anciano , Anciano de 80 o más Años , Disfunción Cognitiva/complicaciones , Barreras de Comunicación , Estudios de Factibilidad , Femenino , Insuficiencia Cardíaca/complicaciones , Humanos , Masculino , Persona de Mediana Edad , Modelos Teóricos , Proyectos Piloto , Evaluación de Programas y Proyectos de Salud , Psicometría , Autocuidado/normas
17.
Med J Aust ; 199(3): 160-2, 2013 Aug 05.
Artículo en Inglés | MEDLINE | ID: mdl-23909527

RESUMEN

Improvements in BP control with pharmacotherapy undoubtedly translate into significant individual and population health benefits. RDN results in impressive reductions in BP, which are likely to be associated with further improvements in clinical outcomes. With more clinical trials and concurrent development of new devices, we hope that RDN holds up to its current accolades.


Asunto(s)
Ablación por Catéter/métodos , Hipertensión/cirugía , Riñón/inervación , Simpatectomía/métodos , Antihipertensivos/uso terapéutico , Australia , Determinación de la Presión Sanguínea/métodos , Progresión de la Enfermedad , Femenino , Humanos , Hipertensión/tratamiento farmacológico , Hipertensión/mortalidad , Hipertensión/fisiopatología , Masculino , Seguridad del Paciente , Pronóstico , Ensayos Clínicos Controlados Aleatorios como Asunto , Medición de Riesgo , Índice de Severidad de la Enfermedad , Tasa de Supervivencia , Sistema Nervioso Simpático/cirugía , Insuficiencia del Tratamiento , Resultado del Tratamiento
18.
Int J Cardiol ; 167(3): 951-3, 2013 Aug 10.
Artículo en Inglés | MEDLINE | ID: mdl-22475843

RESUMEN

BACKGROUND: We undertook a prospective study to assess the impact of routine incorporation of right atrial pressure into the calculation of FFR in a real world elective PCI cohort. METHODS: 42 patients with stenoses in 2 separate epicardial vessels at coronary angiography were studied. Using a temperature and pressure sensing guidewire (TPSG) FFR and FFRRAP were performed in the target vessel pre and post PCI and in a non-target vessel. FFR was defined as Pd/Pa, FFRRAP as Pd-Pv/Pa-Pv where Pv was right atrial pressure and Pd/Pa were the hyperemic distal and proximal arterial pressures respectively. RESULTS: Mean RAP was 9.1 ± 0.7 mmHg. Mean FFR was significantly lower when RAP was included in the calculation (FFRRAP 0.77 ± 0.19 vs. FFR 0.80 ± 0.16, p<0.001). In the target vessel pre PCI, incorporating RAP into the calculation of FFR resulted in a significant difference in the FFR value (FFR Pre-PCI 0.69 ± 0.02 vs. FFRRAP Pre-PCI 0.63 ± 0.03, p<0.0001). 21 patients had an FFR ≤ 0.8 in the group. If right atrial pressure were utilized to calculate FFR prior to PCI, an additional 9 patients would have been re-categorised to an FFR ≤ 0.8. Following PCI, mean FFR was lower when RAP was incorporated (Post PCI FFRRAP 0.93±0.05 vs. Post PCI FFR 0.95 ± 0.06, p<0.001). CONCLUSION: Incorporation of right atrial pressure into the calculation of FFR significantly alters FFR values and may potentially reclassify lesions below ischaemic thresholds.


Asunto(s)
Función del Atrio Derecho/fisiología , Presión Atrial/fisiología , Procedimientos Quirúrgicos Electivos/métodos , Reserva del Flujo Fraccional Miocárdico/fisiología , Intervención Coronaria Percutánea/métodos , Anciano , Estudios de Cohortes , Enfermedad de la Arteria Coronaria/diagnóstico , Enfermedad de la Arteria Coronaria/fisiopatología , Enfermedad de la Arteria Coronaria/cirugía , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos
19.
Heart ; 99(2): 98-105, 2013 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-23118346

RESUMEN

BACKGROUND: The long-term results after second generation everolimus eluting bioresorbable vascular scaffold (Absorb BVS) placement in small vessels are unknown. Therefore, we investigated the impact of vessel size on long-term outcomes, after Absorb BVS implantation. METHODS: In ABSORB Cohort B Trial, out of the total study population (101 patients), 45 patients were assigned to undergo 6-month and 2-year angiographic follow-up (Cohort B1) and 56 patients to have angiographic follow-up at 1-year (Cohort B2). The pre-reference vessel diameter (RVD) was <2.5 mm (small-vessel group) in 41 patients (41 lesions) and ≥2.5 mm (large-vessel group) in 60 patients (61 lesions). Outcomes were compared according to pre-RVD. RESULTS: At 2-year angiographic follow-up no differences in late lumen loss (0.29±0.16 mm vs 0.25±0.22 mm, p=0.4391), and in-segment binary restenosis (5.3% vs 5.3% p=1.0000) were demonstrated between groups. In the small-vessel group, intravascular ultrasound analysis showed a significant increase in vessel area (12.25±3.47 mm(2) vs 13.09±3.38 mm(2) p=0.0015), scaffold area (5.76±0.96 mm(2) vs 6.41±1.30 mm(2) p=0.0008) and lumen area (5.71±0.98 mm(2) vs 6.20±1.27 mm(2) p=0.0155) between 6-months and 2-year follow-up. No differences in plaque composition were reported between groups at either time point. At 2-year clinical follow-up, no differences in ischaemia-driven major adverse cardiac events (7.3% vs 10.2%, p=0.7335), myocardial infarction (4.9% vs 1.7%, p=0.5662) or ischaemia-driven target lesion revascularisation (2.4% vs 8.5%, p=0.3962) were reported between small and large vessels. No deaths or scaffold thrombosis were observed. CONCLUSIONS: Similar clinical and angiographic outcomes at 2-year follow-up were reported in small and large vessel groups. A significant late lumen enlargement and positive vessel remodelling were observed in small vessels.


Asunto(s)
Implantes Absorbibles , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Vasos Coronarios/diagnóstico por imagen , Stents Liberadores de Fármacos , Sirolimus/análogos & derivados , Andamios del Tejido , Ultrasonografía Intervencional/métodos , Adolescente , Adulto , Anciano , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/cirugía , Vasos Coronarios/cirugía , Everolimus , Femenino , Estudios de Seguimiento , Humanos , Inmunosupresores/farmacología , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Diseño de Prótesis , Sirolimus/farmacología , Factores de Tiempo , Resultado del Tratamiento , Adulto Joven
20.
Heart ; 98(20): 1492-7, 2012 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-22895644

RESUMEN

BACKGROUND: This study was designed to assess whether measurement of the index of microvascular resistance (IMR) could help prospectively identify patients who develop periprocedural myocardial infarction (PPMI). METHODS AND RESULTS: IMR was measured in 54 patients before and following percutaneous coronary intervention (PCI) in a culprit vessel with a PressureWire using the equation IMR = Pa(Hyp) × Tmn(Hyp) (Pd(Hyp)-Pw/Pa(Hyp)-Pw). IMR was also measured in an angiographically normal reference vessel. The relative pre-IMR ratio (rPIMR) defined as IMR Culprit divided by IMR Non-Culprit was also calculated. Troponin was sequentially sampled up to 24 h following PCI. Mean troponin post-PCI was 0.37±0.8 ng/ml. 33 (61%) patients fulfilled the criteria for PPMI. IMR pre-PCI was the most significant correlate of post-PCI troponin (r=0.43 p=0.001), however, the number of balloon inflations (r=0.3, p=0.02) and rPIMR (r=0.33 p=0.017) were also correlated. IMR pre-PCI was higher in patients with periprocedural myocardial infarction compared with patients without PPMI (IMR pre-PCI 21.2±2.1 PPMI vs 15.6±1.8 No PPMI, p=0.02). The strongest predictor of troponin post-PCI was IMR pre-PCI (ß 0.7, p=0.02). Both IMR pre- and rPIMR were predictive of PPMI (OR 11 (1.3 to 90.5) p=0.026, OR 1.09 (1 to 1.19) p=0.03, respectively). CONCLUSION: Microvascular function prior to PCI is an important determinant of PPMI. Measuring IMR pre-PCI and rPIMR may allow prospective identification of patients at risk of periprocedural myocardial infarction. Future studies in a larger cohort are required to establish the predictive ability of IMR in PPMI.


Asunto(s)
Angina Estable/fisiopatología , Angina Estable/cirugía , Microcirculación , Infarto del Miocardio/diagnóstico , Intervención Coronaria Percutánea , Complicaciones Posoperatorias/diagnóstico , Resistencia Vascular , Procedimientos Quirúrgicos Electivos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...