1.
Europace ; 26(6)2024 Jun 03.
Artículo en Inglés | MEDLINE | ID: mdl-38864730

RESUMEN

AIMS: Patients with structural heart disease (SHD) undergoing catheter ablation (CA) for ventricular tachycardia (VT) are at considerable risk of periprocedural complications, including acute haemodynamic decompensation (AHD). The PAINESD score was proposed to predict the risk of AHD. The goal of this study was to validate the PAINESD score using the retrospective analysis of data from a large-volume heart centre. METHODS AND RESULTS: Patients who had their first radiofrequency CA for SHD-related VT between August 2006 and December 2020 were included in the study. Procedures were mainly performed under conscious sedation. Substrate mapping/ablation was performed primarily during spontaneous rhythm or right ventricular pacing. A purposely established institutional registry for complications of invasive procedures was used to collect all periprocedural complications that were subsequently adjudicated using the source medical records. Acute haemodynamic decompensation triggered by CA procedure was defined as intraprocedural or early post-procedural (<12 h) development of acute pulmonary oedema or refractory hypotension requiring urgent intervention. The study cohort consisted of 1124 patients (age, 63 ± 13 years; males, 87%; ischaemic cardiomyopathy, 67%; electrical storm, 25%; New York Heart Association Class, 2.0 ± 1.0; left ventricular ejection fraction, 34 ± 12%; diabetes mellitus, 31%; chronic obstructive pulmonary disease, 12%). Their PAINESD score was 11.4 ± 6.6 (median, 12; interquartile range, 6-17). Acute haemodynamic decompensation complicated the CA procedure in 13/1124 = 1.2% patients and was not predicted by PAINESD score with AHD rates of 0.3, 1.8, and 1.1% in subgroups by previously published PAINESD terciles (<9, 9-14, and >14). However, the PAINESD score strongly predicted mortality during the follow-up. CONCLUSION: Primarily substrate-based CA of SHD-related VT performed under conscious sedation is associated with a substantially lower rate of AHD than previously reported. The PAINESD score did not predict these events. The application of the PAINESD score to the selection of patients for pre-emptive mechanical circulatory support should be reconsidered.


Asunto(s)
Ablación por Catéter , Hemodinámica , Taquicardia Ventricular , Humanos , Taquicardia Ventricular/cirugía , Taquicardia Ventricular/fisiopatología , Taquicardia Ventricular/etiología , Taquicardia Ventricular/diagnóstico , Masculino , Femenino , Persona de Mediana Edad , Ablación por Catéter/efectos adversos , Estudios Retrospectivos , Cicatriz/fisiopatología , Anciano , Hipotensión/etiología , Hipotensión/fisiopatología , Hipotensión/diagnóstico , Edema Pulmonar/etiología , Edema Pulmonar/diagnóstico , Edema Pulmonar/fisiopatología , Complicaciones Posoperatorias/etiología , Complicaciones Posoperatorias/diagnóstico , Factores de Riesgo
2.
J Cardiothorac Surg ; 19(1): 397, 2024 Jun 27.
Artículo en Inglés | MEDLINE | ID: mdl-38937763

RESUMEN

OBJECTIVES: Current recommendations support surgical treatment of atrial fibrillation (AF) in patients indicated for cardiac surgery. These procedures are referred to as concomitant and may be carried out using radiofrequency energy or cryo-ablation. This study aimed to assess the electrophysiological findings in patients undergoing concomitant cryo-ablation. METHODS: Patients with non-paroxysmal AF undergoing coronary artery bypass grafting and/or valve repair/replacement were included in the trial if concomitant cryo-ablation was part of the treatment plan according to current guidelines. The patients reported in this study were assigned to undergo staged percutaneous radiofrequency catheter ablation (PRFCA), i.e., hybrid treatment, as a part of the SURHYB trial protocol. RESULTS: We analyzed 103 patients who underwent PRFCA 105 ± 35 days after surgery. Left and right pulmonary veins (PVs) were found isolated in 65 (63.1%) and 63 (61.2%) patients, respectively. The LA posterior wall isolation and mitral isthmus conduction block were found in 38 (36.9%) and 18 (20.0%) patients, respectively. Electrical reconnections (gaps) in the left PVs were more often localized superiorly than inferiorly (57.9% vs. 26.3%, P = 0.005) and anteriorly than posteriorly (65.8% vs. 31.6%, P = 0.003). Gaps in the right PVs were more equally distributed anteroposteriorly but dominated in superior segments (72.5% vs. 40.0%, P = 0.003). There was a higher number of gaps on the roof line compared to the inferior line (131 (67.2%) vs. 67 (42.2%), P < 0.001). Compared to epicardial cryo-ablation, endocardial was more effective in creating PVs and LA posterior wall isolation (P < 0.05). Cryo-ablation using nitrous oxide (N20) or argon (Ar) gas as cooling agents was similarly effective (P = NS). CONCLUSIONS: The effectiveness of surgical cryo-ablation in achieving transmural and durable lesions in the left atrium is surprisingly low. Gaps are located predominantly in the superior and anterior portions of the PVs and on the roof line. Endocardial cryo-ablation is more effective than epicardial ablation, irrespective of the cooling agent used.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Criocirugía , Venas Pulmonares , Humanos , Fibrilación Atrial/cirugía , Criocirugía/métodos , Masculino , Femenino , Ablación por Catéter/métodos , Persona de Mediana Edad , Anciano , Venas Pulmonares/cirugía , Resultado del Tratamiento , Puente de Arteria Coronaria/métodos
4.
Europace ; 26(5)2024 May 02.
Artículo en Inglés | MEDLINE | ID: mdl-38646926

RESUMEN

AIMS: Using thermal-based energy sources [radiofrequency (RF) energy/cryo energy] for catheter ablation is considered effective and safe when performing pulmonary vein isolation (PVI) in patients with paroxysmal atrial fibrillation (AF). However, treatment success remains limited and complications can occur due to the propagation of thermal energy into non-target tissues. We aim to compare pulsed field ablation (PFA) with RF ablation in terms of efficacy and safety for patients with drug-resistant paroxysmal AF. METHODS AND RESULTS: The BEAT PAROX-AF trial is a European multicentre, superiority, open-label randomized clinical trial in two parallel groups. A total of 292 participants were recruited in 9 high-volume European clinical centres in 5 countries. Patients with paroxysmal AF were randomized to PFA (FARAPULSE Endocardial Ablation System©, Boston Scientific) or RF using the CLOSE protocol with contact force sensing catheter (SmartTouch© catheter and CARTO© Biosense Webster). The primary endpoint will be the 1-year recurrence of atrial arrhythmia, and the major secondary safety endpoint will be the occurrence of acute (<7 days) procedure-related serious adverse events, or pulmonary vein stenosis, or atrio-oesophageal fistula up to 12 months. Additionally, five sub-studies investigate the effect of PFA on oesophageal safety, cerebral lesions, cardiac autonomic nervous system, durability of PVI as assessed during redo ablation procedures, and atrial and ventricular function. The study began on 27 December 2021 and concluded recruitment on 17 January 2024. Results will be available in mid-2025. CONCLUSION: The BEAT PAROX-AF trial aims to provide critical insights into the optimal treatment approach for patients with paroxysmal AF.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Humanos , Fibrilación Atrial/cirugía , Fibrilación Atrial/fisiopatología , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/terapia , Ablación por Catéter/métodos , Resultado del Tratamiento , Venas Pulmonares/cirugía , Femenino , Masculino , Recurrencia , Europa (Continente) , Persona de Mediana Edad
6.
Europace ; 26(2)2024 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-38306687

RESUMEN

AIMS: Data on the hybrid atrial fibrillation (AF) treatment are lacking in patients with structural heart disease undergoing concomitant CryoMaze procedures. The aim was to assess whether the timely pre-emptive catheter ablation would achieve higher freedom from AF or atrial tachycardia (AT) and be associated with better clinical outcomes than surgical ablation alone. METHODS AND RESULTS: The trial investigated patients with non-paroxysmal AF undergoing coronary artery bypass grafting and/or valve repair/replacement with mandatory concomitant CryoMaze procedure who were randomly assigned to undergo either radiofrequency catheter ablation [Hybrid Group (HG)] or no further treatment (Surgery Group). The primary efficacy endpoint was the first recurrence of AF/AT without class I or III antiarrhythmic drugs as assessed by implantable cardiac monitors. The primary clinical endpoint was a composite of hospitalization for arrhythmia recurrence, worsening of heart failure, cardioembolic event, or major bleeding. We analysed 113 and 116 patients in the Hybrid and Surgery Groups, respectively, with a median follow-up of 715 (IQR: 528-1072) days. The primary efficacy endpoint was significantly reduced in the HG [41.1% vs. 67.4%, hazard ratio (HR) = 0.38, 95% confidence interval (CI): 0.26-0.57, P < 0.001] as well as the primary clinical endpoint (19.9% vs. 40.1%, HR = 0.51, 95% CI: 0.29-0.86, P = 0.012). The trial groups did not differ in all-cause mortality (10.6% vs. 8.6%, HR = 1.17, 95%CI: 0.51-2.71, P = 0.71). The major complications of catheter ablation were infrequent (1.9%). CONCLUSION: Pre-emptively performed catheter ablation after the CryoMaze procedure was safe and associated with higher freedom from AF/AT and improved clinical outcomes.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Taquicardia Supraventricular , Humanos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Fibrilación Atrial/tratamiento farmacológico , Resultado del Tratamiento , Taquicardia Supraventricular/cirugía , Antiarrítmicos/uso terapéutico , Hemorragia , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Recurrencia
7.
JACC Clin Electrophysiol ; 10(4): 654-666, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38385912

RESUMEN

BACKGROUND: Stereotactic arrhythmia radiotherapy (STAR) has been proposed recently in patients with refractory ventricular tachycardia (VT). OBJECTIVES: The purpose of this study was to describe the efficacy and safety of STAR in the Czech Republic. METHODS: VT patients were recruited in 2 expert centers after at least 1 previously failed catheter ablation (CA). A precise strategy of target volume determination and CA was used in 17 patients treated from December 2018 until June 2022 (EFFICACY cohort). This group, together with an earlier series of 19 patients with less-defined treatment strategies, composed the SAFETY cohort (n = 36). A dose of 25 Gy was delivered. RESULTS: In the EFFICACY cohort, the burden of implantable cardioverter-defibrillator therapies decreased, and this drop reached significance for direct current shocks (1.9 ± 3.2 vs 0.1 ± 0.2 per month; P = 0.03). Eight patients (47%) underwent repeated CA for recurrences of VT during 13.7 ± 11.6 months. In the SAFETY cohort (32 procedures, follow-up >6 months), 8 patients (25%) presented with a progression of mitral valve regurgitation, and 3 (9%) required intervention (median follow-up of 33.5 months). Two cases of esophagitis (6%) were seen with 1 death caused by the esophago-pericardial fistula (3%). A total of 18 patients (50%) died during the median follow-up of 26.9 months. CONCLUSIONS: Although STAR may not be very effective in preventing VT recurrences after failed CA in an expert center, it can still modify the arrhythmogenic substrate, and when used with additional CA, reduce the number of implantable cardioverter-defibrillator shocks. Potentially serious sides effects require close follow-up.


Asunto(s)
Radiocirugia , Taquicardia Ventricular , Humanos , Masculino , Taquicardia Ventricular/cirugía , Femenino , Persona de Mediana Edad , República Checa , Anciano , Radiocirugia/efectos adversos , Radiocirugia/métodos , Recurrencia , Desfibriladores Implantables , Ablación por Catéter/efectos adversos , Resultado del Tratamiento
8.
Eur Heart J ; 45(10): 837-849, 2024 Mar 07.
Artículo en Inglés | MEDLINE | ID: mdl-37956458

RESUMEN

BACKGROUND AND AIMS: Patients with long atrial high-rate episodes (AHREs) ≥24 h and stroke risk factors are often treated with anticoagulation for stroke prevention. Anticoagulation has never been compared with no anticoagulation in these patients. METHODS: This secondary pre-specified analysis of the Non-vitamin K antagonist Oral anticoagulants in patients with Atrial High-rate episodes (NOAH-AFNET 6) trial examined interactions between AHRE duration at baseline and anticoagulation with edoxaban compared with placebo in patients with AHRE and stroke risk factors. The primary efficacy outcome was a composite of stroke, systemic embolism, or cardiovascular death. The safety outcome was a composite of major bleeding and death. Key secondary outcomes were components of these outcomes and electrocardiogram (ECG)-diagnosed atrial fibrillation. RESULTS: Median follow-up of 2389 patients with core lab-verified AHRE was 1.8 years. AHRE ≥24 h were present at baseline in 259/2389 patients (11%, 78 ± 7 years old, 28% women, CHA2DS2-VASc 4). Clinical characteristics were not different from patients with shorter AHRE. The primary outcome occurred in 9/132 patients with AHRE ≥24 h (4.3%/patient-year, 2 strokes) treated with anticoagulation and in 14/127 patients treated with placebo (6.9%/patient-year, 2 strokes). Atrial high-rate episode duration did not interact with the efficacy (P-interaction = .65) or safety (P-interaction = .98) of anticoagulation. Analyses including AHRE as a continuous parameter confirmed this. Patients with AHRE ≥24 h developed more ECG-diagnosed atrial fibrillation (17.0%/patient-year) than patients with shorter AHRE (8.2%/patient-year; P < .001). CONCLUSIONS: This hypothesis-generating analysis does not find an interaction between AHRE duration and anticoagulation therapy in patients with device-detected AHRE and stroke risk factors. Further research is needed to identify patients with long AHRE at high stroke risk.


Asunto(s)
Fibrilación Atrial , Piridinas , Accidente Cerebrovascular , Tiazoles , Humanos , Femenino , Anciano , Anciano de 80 o más Años , Masculino , Fibrilación Atrial/complicaciones , Fibrilación Atrial/tratamiento farmacológico , Fibrilación Atrial/diagnóstico , Atrios Cardíacos , Factores de Riesgo , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/prevención & control , Accidente Cerebrovascular/diagnóstico , Anticoagulantes/uso terapéutico
10.
Am J Cardiol ; 208: 156-163, 2023 12 01.
Artículo en Inglés | MEDLINE | ID: mdl-37839172

RESUMEN

Plasma natriuretic peptides (NPs) are increased in patients with atrial fibrillation (AF) compared with the patients with sinus rhythm. This study investigated whether this phenomenon is intrinsic to heart rhythm irregularity and independent of the heart rate and left atrial pressure (LAP) overload. We investigated 46 patients (age: 59 ± 10 years, male gender: 77%) with non-valvular paroxysmal AF who were scheduled for catheter ablation and had documented stable sinus rhythm for at least 18 hours before the procedure. All patients underwent direct measurement of right atrial pressure and LAP, simultaneously with assessment of plasma B-type NP, N-terminal pro-brain NP, and mid-regional pro-atrial NP. The baseline measurement was followed by induction of AF by rapid atrial pacing in the first 24 patients and by regular pacing from the coronary sinus at 100/min (corresponding to the mean heart rate during induced AF) in the latter 22 patients. Hemodynamic assessment and blood sampling were repeated after 20 min of the ongoing AF or fast regular paging. The baseline characteristics and hemodynamic measurements were comparable between study groups; however, patients in the regular atrial pacing group had a higher body mass index and a larger left atrial diameter compared with the induced AF group. Plasma levels of all 3 NPs increased significantly during induced AF but not during fast regular pacing, and the increase of NPs was independent of right atrial pressure and LAP. Baseline concentrations of NPs and heart rhythm irregularity were the only independent predictors of increased NPs.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Humanos , Masculino , Persona de Mediana Edad , Anciano , Frecuencia Cardíaca , Presión Atrial/fisiología , Péptidos Natriuréticos , Atrios Cardíacos , Ablación por Catéter/métodos
11.
Europace ; 25(9)2023 08 02.
Artículo en Inglés | MEDLINE | ID: mdl-37695316

RESUMEN

AIMS: Several studies have evaluated the use of electrically- or imaging-guided left ventricular (LV) lead placement in cardiac resynchronization therapy (CRT) recipients. We aimed to assess evidence for a guided strategy that targets LV lead position to the site of latest LV activation. METHODS AND RESULTS: A systematic review and meta-analysis was performed for randomized controlled trials (RCTs) until March 2023 that evaluated electrically- or imaging-guided LV lead positioning on clinical and echocardiographic outcomes. The primary endpoint was a composite of all-cause mortality and heart failure hospitalization, and secondary endpoints were quality of life, 6-min walk test (6MWT), QRS duration, LV end-systolic volume, and LV ejection fraction. We included eight RCTs that comprised 1323 patients. Six RCTs compared guided strategy (n = 638) to routine (n = 468), and two RCTs compared different guiding strategies head-to-head: electrically- (n = 111) vs. imaging-guided (n = 106). Compared to routine, a guided strategy did not significantly reduce the risk of the primary endpoint after 12-24 (RR 0.83, 95% CI 0.52-1.33) months. A guided strategy was associated with slight improvement in 6MWT distance after 6 months of follow-up of absolute 18 (95% CI 6-30) m between groups, but not in remaining secondary endpoints. None of the secondary endpoints differed between the guided strategies. CONCLUSION: In this study, a CRT implantation strategy that targets the latest LV activation did not improve survival or reduce heart failure hospitalizations.


Asunto(s)
Terapia de Resincronización Cardíaca , Insuficiencia Cardíaca , Humanos , Terapia de Resincronización Cardíaca/efectos adversos , Ecocardiografía , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/terapia , Ventrículos Cardíacos/diagnóstico por imagen , Hospitalización
12.
N Engl J Med ; 389(13): 1167-1179, 2023 Sep 28.
Artículo en Inglés | MEDLINE | ID: mdl-37622677

RESUMEN

BACKGROUND: Device-detected atrial high-rate episodes (AHREs) are atrial arrhythmias detected by implanted cardiac devices. AHREs resemble atrial fibrillation but are rare and brief. Whether the occurrence of AHREs in patients without atrial fibrillation (as documented on a conventional electrocardiogram [ECG]) justifies the initiation of anticoagulants is not known. METHODS: We conducted an event-driven, double-blind, double-dummy, randomized trial involving patients 65 years of age or older who had AHREs lasting for at least 6 minutes and who had at least one additional risk factor for stroke. Patients were randomly assigned in a 1:1 ratio to receive edoxaban or placebo. The primary efficacy outcome was a composite of cardiovascular death, stroke, or systemic embolism, evaluated in a time-to-event analysis. The safety outcome was a composite of death from any cause or major bleeding. RESULTS: The analysis population consisted of 2536 patients (1270 in the edoxaban group and 1266 in the placebo group). The mean age was 78 years, 37.4% were women, and the median duration of AHREs was 2.8 hours. The trial was terminated early, at a median follow-up of 21 months, on the basis of safety concerns and the results of an independent, informal assessment of futility for the efficacy of edoxaban; at termination, the planned enrollment had been completed. A primary efficacy outcome event occurred in 83 patients (3.2% per patient-year) in the edoxaban group and in 101 patients (4.0% per patient-year) in the placebo group (hazard ratio, 0.81; 95% confidence interval [CI], 0.60 to 1.08; P = 0.15). The incidence of stroke was approximately 1% per patient-year in both groups. A safety outcome event occurred in 149 patients (5.9% per patient-year) in the edoxaban group and in 114 patients (4.5% per patient-year) in the placebo group (hazard ratio, 1.31; 95% CI, 1.02 to 1.67; P = 0.03). ECG-diagnosed atrial fibrillation developed in 462 of 2536 patients (18.2% total, 8.7% per patient-year). CONCLUSIONS: Among patients with AHREs detected by implantable devices, anticoagulation with edoxaban did not significantly reduce the incidence of a composite of cardiovascular death, stroke, or systemic embolism as compared with placebo, but it led to a higher incidence of a composite of death or major bleeding. The incidence of stroke was low in both groups. (Funded by the German Center for Cardiovascular Research and others; NOAH-AFNET 6 ClinicalTrials.gov number, NCT02618577; ISRCTN number, ISRCTN17309850.).


Asunto(s)
Anticoagulantes , Arritmias Cardíacas , Embolia , Inhibidores del Factor Xa , Anciano , Femenino , Humanos , Masculino , Anticoagulantes/efectos adversos , Anticoagulantes/uso terapéutico , Fibrilación Atrial/complicaciones , Fibrilación Atrial/diagnóstico , Embolia/tratamiento farmacológico , Embolia/etiología , Inhibidores del Factor Xa/efectos adversos , Inhibidores del Factor Xa/uso terapéutico , Hemorragia/inducido químicamente , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/prevención & control , Electrodos Implantados , Método Doble Ciego , Arritmias Cardíacas/complicaciones , Arritmias Cardíacas/diagnóstico , Factores de Riesgo
15.
Europace ; 25(7)2023 07 04.
Artículo en Inglés | MEDLINE | ID: mdl-37345804

RESUMEN

Atrial high-rate episodes (AHRE) are atrial tachyarrhythmias detected by continuous rhythm monitoring by pacemakers, defibrillators, or implantable cardiac monitors. Atrial high-rate episodes occur in 10-30% of elderly patients without atrial fibrillation. However, it remains unclear whether the presence of these arrhythmias has therapeutic consequences. The presence of AHRE increases the risk of stroke compared with patients without AHRE. Oral anticoagulation would have the potential to reduce the risk of stroke in patients with AHRE but is also associated with a rate of major bleeding of ∼2%/year. The stroke rate in patients with AHRE appears to be lower than the stroke rate in patients with atrial fibrillation. Wearables like smart-watches will increase the absolute number of patients in whom atrial arrhythmias are detected. It remains unclear whether anticoagulation is effective and, equally important, safe in patients with AHRE. Two randomized clinical trials, NOAH-AFNET6 and ARTESiA, are expected to report soon. They will provide much-needed information on the efficacy and safety of oral anticoagulation in patients with AHRE.


Asunto(s)
Fibrilación Atrial , Accidente Cerebrovascular , Humanos , Anciano , Fibrilación Atrial/complicaciones , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/tratamiento farmacológico , Factores de Riesgo , Anticoagulantes/uso terapéutico , Atrios Cardíacos , Accidente Cerebrovascular/diagnóstico , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/prevención & control
16.
J Appl Biomed ; 21(2): 67-72, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-37212155

RESUMEN

BACKGROUND: Atrial fibrillation is common in patients with structural heart disease who are undergoing cardiac surgery. Surgical CryoMaze has been shown to be an effective treatment in several trials, but success rates have varied considerably, between 47-95%. The sequential hybrid approach, combining surgical CryoMaze followed by radiofrequency catheter ablation, can achieve high freedom from atrial arrhythmias. However, in patients with concomitant surgical atrial fibrillation treatment, data comparing the hybrid approach to CryoMaze alone are lacking. METHODS: The SurHyb study was designed as a prospective, open-label, multicentre randomized trial. Patients with non-paroxysmal atrial fibrillation who were scheduled for coronary artery bypass grafting or valve repair/replacement were randomized to either surgical CryoMaze alone or surgical CryoMaze followed by radiofrequency catheter ablation 3 months post-surgery. The primary outcome measure was arrhythmia-free survival without class I or III antiarrhythmic drugs, which has been evaluated using implantable cardiac monitors. CONCLUSIONS: This is the first randomized study that compares concomitant surgical CryoMaze alone with the staged hybrid surgical CryoMaze followed by catheter ablation, in patients with non-paroxysmal atrial fibrillation using rigorous rhythm monitoring. The results may contribute to the optimization of the treatment in patients undergoing concomitant CryoMaze for atrial fibrillation.


Asunto(s)
Fibrilación Atrial , Procedimientos Quirúrgicos Cardíacos , Ablación por Catéter , Humanos , Antiarrítmicos/uso terapéutico , Fibrilación Atrial/cirugía , Fibrilación Atrial/tratamiento farmacológico , Procedimientos Quirúrgicos Cardíacos/métodos , Ablación por Catéter/métodos , Estudios Multicéntricos como Asunto , Estudios Prospectivos , Ensayos Clínicos Controlados Aleatorios como Asunto , Resultado del Tratamiento
17.
Europace ; 2023 May 13.
Artículo en Inglés | MEDLINE | ID: mdl-37178136

RESUMEN

AIMS: Atrial fibrillation (AF), typical atrial flutter (AFL), and other atrial tachycardias (ATs) are common in patients with pulmonary hypertension. Frequently, several supraventricular arrhythmias are successively observed in individual patients. We investigated the hypothesis of whether more extensive radiofrequency catheter ablation of the bi-atrial arrhythmogenic substrate instead of clinical arrhythmia ablation alone results in superior clinical outcomes in patients with pulmonary arterial hypertension (PH) and supraventricular arrhythmias. METHODS AND RESULTS: Patients with combined post- and pre-capillary or isolated pre-capillary PH and supraventricular arrhythmia indicated to catheter ablation were enrolled in three centres and randomized 1:1 into two parallel treatment arms. Patients underwent either clinical arrhythmia ablation only (Limited ablation group) or clinical arrhythmia plus substrate-based ablation (Extended ablation group). The primary endpoint was arrhythmia recurrence >30 s without antiarrhythmic drugs after the 3-month blanking period. A total of 77 patients (mean age 67 ± 10 years; 41 males) were enrolled. The presumable clinical arrhythmia was AF in 38 and AT in 36 patients, including typical AFL in 23 patients. During the median follow-up period of 13 (interquartile range: 12; 19) months, the primary endpoint occurred in 15 patients (42%) vs. 17 patients (45%) in the Extended vs. Limited ablation group (hazard ratio: 0.97, 95% confidence interval: 0.49-2.0). There was no excess of procedural complications and clinical follow-up events including an all-cause death in the Extended ablation group. CONCLUSION: Extensive ablation, compared with a limited approach, was not beneficial in terms of arrhythmia recurrence in patients with AF/AT and PH. CLINICAL TRIALS REGISTRATION: ClinicalTrials.gov; NCT04053361.

20.
Diagnostics (Basel) ; 12(11)2022 Nov 15.
Artículo en Inglés | MEDLINE | ID: mdl-36428866

RESUMEN

The new clinical prediction score (SCORE) has been recently proposed for primary aldosteronism (PA) subtyping prior to adrenal vein sampling (AVS). This study aimed to compare that SCORE with previously published scores and their validation using a cohort of patients at our center who had had positive SIT confirming PA and had been diagnosed with either bilateral PA according to AVS or unilateral PA if biochemically cured after an adrenalectomy. Final diagnoses were used to evaluate the diagnostic performance of the proposed clinical prediction tools. Only Kamemura's model (with a maximum score of 4 points) and Kobayashi's score (with a maximum score of 12 points) reached 100% reliability for prediction of bilateral PA; however, with sensitivity of only 3%. On the other hand, the values of SCORE = 3 (with sensitivity of 48%), the SPACE score ≥18 (with sensitivity of 35%), the Kobayashi's score ≤2 (with sensitivity of 28%), and the Kocjan's score = 3 (with sensitivity of 28%) were able to predict unilateral PA with 100% probability. Furthermore, Umakoshi's and Young's models both reached 100% reliability for a unilateral PA with score = 4 and both predictive factors together respectively; however, the sensitivity was lower compared with previous models; 4% and 14%, respectively. None of the clinical prediction tools applied to our cohort predicted unilateral and bilateral subtypes together with the expected high diagnostic performance, and therefore can only be used for precisely defined cases.

SELECCIÓN DE REFERENCIAS