1.
J Am Chem Soc ; 2024 Aug 07.
Artículo en Inglés | MEDLINE | ID: mdl-39110484

RESUMEN

Aggregation of protein-based therapeutics can occur during development, production, or storage and can lead to loss of efficacy and potential toxicity. Native mass spectrometry of a covalently linked pentameric monoclonal antibody complex with a mass of ∼800 kDa reveals several distinct conformations, smaller complexes, and abundant higher-order aggregates of the pentameric species. Charge detection mass spectrometry (CDMS) reveals individual oligomers up to the pentamer mAb trimer (15 individual mAb molecules; ∼2.4 MDa) whereas intermediate aggregates composed of 6-9 mAb molecules and aggregates larger than the pentameric dimer (1.6 MDa) were not detected/resolved by standard mass spectrometry, size exclusion chromatography (SEC), capillary electrophoresis (CE-SDS), or by mass photometry. Conventional quadrupole time-of-flight mass spectrometry (QTOF MS), mass photometry, SEC, and CE-SDS did not resolve partially or more fully unfolded conformations of each oligomer that were readily identified using CDMS by their significantly higher extents of charging. Trends in the charge-state distributions of individual oligomers provides detailed insight into how the structures of compact and elongated mAb aggregates change as a function of aggregate size. These results demonstrate the advantages of CDMS for obtaining accurate masses and information about the conformations of large antibody aggregates despite extensive overlapping m/z values. These results open up the ability to investigate structural changes that occur in small, soluble oligomers during the earliest stages of aggregation for antibodies or other proteins.

2.
ACS Nano ; 18(27): 17806-17814, 2024 Jul 09.
Artículo en Inglés | MEDLINE | ID: mdl-38913932

RESUMEN

A variety of scattering-based, microscopy-based, and mobility-based methods are frequently used to probe the size distributions of colloidal nanoparticles with transmission electron microscopy (TEM) often considered to be the "gold standard". Charge detection mass spectrometry (CDMS) is an alternative method for nanoparticle characterization that can rapidly measure the mass and charge of individual nanoparticle ions with high accuracy. Two low polydispersity, ∼100 nm diameter nanoparticle size standards with different compositions (polymethyl methacrylate/polystyrene copolymer and 100% polystyrene) were characterized using both TEM and CDMS to explore the merits and complementary aspects of both methods. Mass and diameter distributions are rapidly obtained from CDMS measurements of thousands of individual ions of known spherical shape, requiring less time than TEM sample preparation and image analysis. TEM image-to-image variations resulted in a ∼1-2 nm range in the determined mean diameters whereas the CDMS mass precision of ∼1% in these experiments leads to a diameter uncertainty of just 0.3 nm. For the 100% polystyrene nanoparticles with known density, the CDMS and TEM particle diameter distributions were in excellent agreement. For the copolymer nanoparticles with unknown density, the diameter from TEM measurements combined with the mass from CDMS measurements enabled an accurate measurement of nanoparticle density. Differing extents of charging for the two nanoparticle standards measured by CDMS show that charging is sensitive to nanoparticle surface properties. A mixture of the two samples was separated based on their different extents of charging despite having overlapping mass distributions centered at 341.5 and 331.0 MDa.

3.
Analyst ; 149(8): 2281-2290, 2024 Apr 15.
Artículo en Inglés | MEDLINE | ID: mdl-38497240

RESUMEN

Variable temperature electrospray mass spectrometry is useful for multiplexed measurements of the thermal stabilities of biomolecules, but the ionization process can be disrupted by aggregation-prone proteins/complexes that have irreversible unfolding transitions. Resistively heating solutions containing a mixture of bovine carbonic anhydrase II (BCAII), a CO2 fixing enzyme involved in many biochemical pathways, and cytochrome c leads to complete loss of carbonic anhydrase signal and a significant reduction in cytochrome c signal above ∼72 °C due to aggregation. In contrast, when the tips of borosilicate glass nanoelectrospray emitters are heated with a laser, complete thermal denaturation curves for both proteins are obtained in <1 minute. The simultaneous measurements of the melting temperature of BCAII and BCAII bound to bicarbonate reveal that the bicarbonate stabilizes the folded form of this protein by ∼6.4 °C. Moreover, the temperature dependences of different bicarbonate loss pathways are obtained. Although protein analytes are directly heated by the laser for only 140 ms, heat conduction further up the emitter leads to a total analyte heating time of ∼41 s. Pulsed laser heating experiments could reduce this time to ∼0.5 s for protein aggregation that occurs on a faster time scale. Laser heating provides a powerful method for studying the detailed mechanisms of cofactor/ligand loss with increasing temperature and promises a new tool for studying the effect of ligands, drugs, growth conditions, buffer additives, or other treatments on the stabilities of aggregation-prone biomolecules.


Asunto(s)
Bicarbonatos , Anhidrasa Carbónica II , Animales , Bovinos , Anhidrasa Carbónica II/química , Calor , Citocromos c , Proteínas/química , Espectrometría de Masas
4.
Sci Adv ; 10(4): eadj3786, 2024 Jan 26.
Artículo en Inglés | MEDLINE | ID: mdl-38266077

RESUMEN

Adeno-associated viruses (AAVs) hold tremendous promise as delivery vectors for gene therapies. AAVs have been successfully engineered-for instance, for more efficient and/or cell-specific delivery to numerous tissues-by creating large, diverse starting libraries and selecting for desired properties. However, these starting libraries often contain a high proportion of variants unable to assemble or package their genomes, a prerequisite for any gene delivery goal. Here, we present and showcase a machine learning (ML) method for designing AAV peptide insertion libraries that achieve fivefold higher packaging fitness than the standard NNK library with negligible reduction in diversity. To demonstrate our ML-designed library's utility for downstream engineering goals, we show that it yields approximately 10-fold more successful variants than the NNK library after selection for infection of human brain tissue, leading to a promising glial-specific variant. Moreover, our design approach can be applied to other types of libraries for AAV and beyond.


Asunto(s)
Dependovirus , Terapia Genética , Humanos , Dependovirus/genética , Biblioteca de Péptidos , Encéfalo , Aprendizaje Automático
5.
Analyst ; 149(3): 735-744, 2024 Jan 29.
Artículo en Inglés | MEDLINE | ID: mdl-38189568

RESUMEN

Salt cluster ions produced by electrospray ionization are used for mass calibration and fundamental investigations into cluster stability and charge separation processes. However, previous studies have been limited to relatively small clusters owing to the heterogeneity associated with large, multiply-charged clusters that leads to unresolved signals in conventional m/z spectra. Here, charge detection mass spectrometry is used to measure both the mass and charge distributions of positively charged clusters of KCl, CaCl2, and LaCl3 with masses between ∼1 and 10 MDa by dynamically measuring the energy per charge, m/z, charge, and mass of simultaneously trapped individual ions throughout a 1 s trapping time. The extent of remaining hydration on the clusters, determined from the change in the frequency of ion motion with time as a result of residual water loss, follows the order KCl < CaCl2 < LaCl3, and is significantly lower than that of a pure water nanodrop, consistent with tighter water binding to the more highly charged cations in these clusters. The number of ion emission events from these clusters also follows this same trend, indicating that water at the cluster surface facilitates charge loss. A new frequency-based method to determine the magnitude of the charge loss resulting from individual ion emission events clearly resolves losses of +1 and +2 ions. Achieving this individual charge state resolution for ion emission events is an important advance in obtaining information about the late stages of bare gaseous ions formation. Future experiments on more hydrated clusters are expected to lead to a better understanding of ion formation in electrospray ionization.

6.
Anal Chem ; 95(45): 16659-16667, 2023 Nov 14.
Artículo en Inglés | MEDLINE | ID: mdl-37917546

RESUMEN

The ability to determine ion energies in electrostatic ion-trap-based charge detection mass spectrometry (CDMS) experiments is important for the accurate measurement of individual ion m/z, charge, and mass. Dynamic energy measurements throughout the time an ion is trapped take advantage of the relationship between ion energy and the harmonic amplitude ratio (HAR) composed from the fundamental and second harmonic amplitudes in the Fourier transform of the ion signal. This method eliminates the need for energy-filtering optics in CDMS and makes it possible to measure energy lost in collisions and changes in ion masses due to dissociation. However, the accuracy of the energy measurement depends on the signal-to-noise ratio (S/N) of the amplitudes used to determine the HAR. Here, a major improvement to this HAR-based dynamic energy measurement method is achieved using HARs composed of higher-order harmonics in addition to the fundamental and second harmonic to determine ion energies. This combined harmonic amplitude ratios for precision energy refinement (CHARPER) method is applied to the analysis of a 103 nm polystyrene nanoparticle ion (359.7 MDa, m/z = 308,300) and the energy resolution (3140) and effective mass resolution (730) achieved are the best yet demonstrated in electrostatic ion-trap-based CDMS. The CHARPER method applied to an ensemble of several thousand adeno-associated virus ion signals also results in higher mass resolution compared to the basic HAR method, making it possible to resolve additional features in the composite mass histogram.

7.
Anal Chem ; 95(39): 14777-14786, 2023 Oct 03.
Artículo en Inglés | MEDLINE | ID: mdl-37729435

RESUMEN

Two solutions can be rapidly mixed using theta glass emitters, with products measured using electrospray ionization mass spectrometry. The relative flow rates of the two emitter channels can be measured using different calibration compounds in each channel, or the flow rates are often assumed to be the same. The relative flow rates of each channel can be essentially the same when the emitters are positioned directly in front of the capillary entrance of a mass spectrometer, but the relative flow rates can be varied by up to 3 orders of magnitude by moving the position of the emitter tip ±1 cm in a direction that is perpendicular to the inner divider. Results of the emitter position on the different concentrations of reagents in the initially formed electrospray droplets are demonstrated through protein denaturation using a supercharging reagent as well as two different bimolecular reactions. The average charge state of myoglobin changed from +7.8 to +13.8 when 2.5% sulfolane was mixed with a 200 mM ammonium acetate solution containing the protein when the position of the emitter was scanned in front of the mass spectrometer inlet. The conversion ratio of a bimolecular reaction was changed from 0.98 to 0.04 with varying emitter positions. These results show that the relative flow rates must be carefully monitored because the droplet composition depends strongly on the position of the theta glass emitters. This method can be used to measure the dependence of reaction kinetics on different solution concentrations by using a single emitter and only two solutions.

8.
ACS Cent Sci ; 9(8): 1611-1622, 2023 Aug 23.
Artículo en Inglés | MEDLINE | ID: mdl-37637724

RESUMEN

Fission of micron-size charged droplets has been observed using optical methods, but little is known about fission dynamics and breakup of smaller nanosize droplets that are important in a variety of natural and industrial processes. Here, spontaneous fission of individual aqueous nanodrops formed by electrospray is investigated using charge detection mass spectrometry. Fission processes ranging from formation of just two progeny droplets in 2 ms to production of dozens of progeny droplets over 100+ ms are observed for nanodrops that are charged above the Rayleigh limit. These results indicate that Rayleigh fission is a continuum of processes that produce progeny droplets that vary widely in charge, mass, and number.

9.
Anal Chem ; 95(26): 10077-10086, 2023 Jul 04.
Artículo en Inglés | MEDLINE | ID: mdl-37343124

RESUMEN

Ion-ion interactions in charge detection mass spectrometers that use electrostatic traps to measure masses of individual ions have not been reported previously, although ion trajectory simulations have shown that these types of interactions affect ion energies and thereby degrade measurement performance. Here, examples of interactions between simultaneously trapped ions that have masses ranging from ca. 2 to 350 MDa and ca. 100 to 1000 charges are studied in detail using a dynamic measurement method that makes it possible to track the evolution of the mass, charge, and energy of individual ions over their trapping lifetimes. Signals from ions that have similar oscillation frequencies can have overlapping spectral leakage artifacts that result in slightly increased uncertainties in the mass determination, but these effects can be mitigated by the careful choice of parameters used in the short-time Fourier transform analysis. Energy transfers between physically interacting ions are also observed and quantified with individual ion energy measurement resolution as high as ∼950. The mass and charge of interacting ions do not change, and their corresponding measurement uncertainties are equivalent to ions that do not undergo physical interactions. Simultaneous trapping of multiple ions in CDMS can greatly decrease the acquisition time necessary to accumulate a statistically meaningful number of individual ion measurements. These results demonstrate that while ion-ion interactions can occur when multiple ions are trapped, they have negligible effects on mass accuracy when using the dynamic measurement method.

10.
Chem Sci ; 14(18): 4704-4713, 2023 May 10.
Artículo en Inglés | MEDLINE | ID: mdl-37181782

RESUMEN

Accelerated reactions in microdroplets have been reported for a wide range of reactions with some microdroplet reactions occurring over a million times faster than the same reaction in bulk solution. Unique chemistry at the air-water interface has been implicated as a primary factor for accelerated reaction rates, but the role of analyte concentration in evaporating droplets has not been as well studied. Here, theta-glass electrospray emitters and mass spectrometry are used to rapidly mix two solutions on the low to sub-microsecond time scale and produce aqueous nanodrops with different sizes and lifetimes. We demonstrate that for a simple bimolecular reaction where surface chemistry does not appear to play a role, reaction rate acceleration factors are between 102 and 107 for different initial solution concentrations, and these values do not depend on nanodrop size. A rate acceleration factor of 107 is among the highest reported and can be attributed to concentration of analyte molecules, initially far apart in dilute solution, but brought into close proximity in the nanodrop through evaporation of solvent from the nanodrops prior to ion formation. These data indicate that analyte concentration phenomenon is a significant factor in reaction acceleration where droplet volume throughout the experiment is not carefully controlled.

11.
J Am Soc Mass Spectrom ; 34(6): 1186-1195, 2023 Jun 07.
Artículo en Inglés | MEDLINE | ID: mdl-37249338

RESUMEN

Effects of electrospray voltage on cluster size and abundance formed from aqueous CsI were investigated with emitter tip diameters between 260 ± 7 nm and 2.45 ± 0.30 µm. Cluster size increases with increasing voltage, increasing solution concentration and increasing emitter diameter consistent with formation of larger initial droplet sizes. For emitters with tip diameters above ∼1 µm, varying the voltage either up or down leads to reproducible voltage-dependent extents of cluster formation. In contrast, higher voltages with submicron diameter emitters can lead to only Cs+ and Cs(H2O)+ and no clusters. This change in ion formation reproducibly occurs at spray potentials >1.3 kV for 260 nm emitters and appears to be induced by a corona discharge and material build-up at the emitter tip. Under conditions where abundant Cs+ is observed and no clusters are formed, ions such as K+ and Cu1+ are also observed but ions with more negative solvation energies, such as Ba2+, are not. Similarly, ions from bradykinin and ubiquitin are observed predischarge but not post discharge. Ions with more positive solvation energies can desorb directly from the air-water interface that is created at the tip of these emitters, whereas ions with more negative solvation energies as well as peptide and protein ions do not. These results indicate that ion desorption directly from solution can occur, and similar experiments with even smaller emitters may lead to new insights into ion formation in electrospray ionization.

12.
ACS Nano ; 17(8): 7765-7774, 2023 Apr 25.
Artículo en Inglés | MEDLINE | ID: mdl-37027782

RESUMEN

The sizes and shapes of nanoparticles play a critical role in their chemical and material properties. Common sizing methods based on light scattering or mobility lack individual particle specificity, and microscopy-based methods often require cumbersome sample preparation and image analysis. A promising alternative method for the rapid and accurate characterization of nanoparticle size is charge detection mass spectrometry (CDMS), an emerging technique that measures the masses of individual ions. A recently constructed CDMS instrument designed specifically for high acquisition speed, efficiency, and accuracy is described. This instrument does not rely on an ion energy filter or estimates of ion energy that have been previously required for mass determination, but instead uses direct, in situ measurements. A standardized sample of ∼100 nm diameter polystyrene nanoparticles and ∼50 nm polystyrene nanoparticles with amine-functionalized surfaces are characterized using CDMS and transmission electron microscopy (TEM). Individual nanoparticle masses measured by CDMS are transformed to diameters, and these size distributions are in close agreement with distributions measured by TEM. CDMS analysis also reveals dimerization of ∼100 nm nanoparticles in solution that cannot be determined by TEM due to the tendency of nanoparticles to agglomerate when dried onto a surface. Comparing the acquisition and analysis times of CDMS and TEM shows particle sizing rates up to ∼80× faster are possible using CDMS, even when samples ∼50× more dilute were used. The combination of both high-accuracy individual nanoparticle measurements and fast acquisition rates by CDMS represents an important advance in nanoparticle analysis capabilities.

13.
J Am Chem Soc ; 144(51): 23368-23378, 2022 12 28.
Artículo en Inglés | MEDLINE | ID: mdl-36525679

RESUMEN

The tobacco mosaic viral capsid protein (TMV) is a frequent target for derivatization for myriad applications, including drug delivery, biosensing, and light harvesting. However, solutions of the stacked disk assembly state of TMV are difficult to characterize quantitatively due to their large size and multiple assembled states. Charge detection mass spectrometry (CDMS) addresses the need to characterize heterogeneous populations of large protein complexes in solution quickly and accurately. Using CDMS, previously unobserved assembly states of TMV, including 16-monomer disks and odd-numbered disk stacks, have been characterized. We additionally employed a peptide-protein conjugation reaction in conjunction with CDMS to demonstrate that modified TMV proteins do not redistribute between disks. Finally, this technique was used to discriminate between protein complexes of near-identical mass but different configurations. We have gained a greater understanding of the behavior of TMV, a protein used across a broad variety of fields and applications, in the solution state.


Asunto(s)
Virus del Mosaico del Tabaco , Virus del Mosaico del Tabaco/química , Proteínas de la Cápside/química , Fenómenos Químicos
14.
Anal Chem ; 94(48): 16894-16900, 2022 12 06.
Artículo en Inglés | MEDLINE | ID: mdl-36416756

RESUMEN

Temperature-controlled nanoelectrospray ionization has been used to measure heat-induced conformational changes of biomolecules by mass spectrometry, but long thermal equilibration times associated with heating or cooling an entire emitter limit how fast these data can be acquired. Here, the tip of a borosilicate electrospray emitter is heated using 10.6 µm light from an unfocused CO2 laser. At 1.2 W, the solution inside the emitter tip can be heated from room temperature to a steady-state temperature of 78.2 ± 2.5 °C in less than 0.5 s and cools from 82.6 ± 0.6 °C back to room temperature within 4 s. The time required to establish a steady-state temperature is more than 100-fold faster than that required for a resistively heated emitter due to the low thermal mass. Protein unfolding curves measured as a function of laser power can be acquired in ∼40 s compared to a resistively heated apparatus that required ∼21 min to acquire similar data. Laser power is calibrated to temperature by comparisons of the average charge state of the protein cytochrome c measured with laser heating and with resistive heating. This laser heating method is applied to a three-component protein mixture to demonstrate the ability to rapidly acquire melting temperatures of proteins in mixtures. The ability to rapidly assess the thermal stabilities of multiple proteins simultaneously shows significant promise for coupling temperature-controlled electrospray ionization (ESI) to separation techniques, providing a high-throughput method for determining the effects of solution composition, drug binding, or sequence mutations on protein thermal stability.


Asunto(s)
Calefacción , Proteínas , Espectrometría de Masas , Proteínas/química , Calor , Rayos Láser
15.
J Am Soc Mass Spectrom ; 33(11): 2129-2137, 2022 Nov 02.
Artículo en Inglés | MEDLINE | ID: mdl-36173188

RESUMEN

Short-time Fourier transforms with short segment lengths are typically used to analyze single ion charge detection mass spectrometry (CDMS) data either to overcome effects of frequency shifts that may occur during the trapping period or to more precisely determine the time at which an ion changes mass or charge, or enters an unstable orbit. The short segment lengths can lead to scalloping loss unless a large number of zero-fills are used, making computational time a significant factor in real-time analysis of data. Apodization specific fitting leads to a 9-fold reduction in computation time compared to zero-filling to a similar extent of accuracy. This makes possible real-time data analysis using a standard desktop computer. Rectangular apodization leads to higher resolution than the more commonly used Gaussian or Hann apodization and makes it possible to separate ions with similar frequencies, a significant advantage for experiments in which the masses of many individual ions are measured simultaneously. Equally important is a >20% increase in S/N obtained with rectangular apodization compared to Gaussian or Hann, which directly translates to a corresponding improvement in accuracy of both charge measurements and ion energy measurements that rely on the amplitudes of the fundamental and harmonic frequencies. Combined with computing the fast Fourier transform in a lower-level language, this fitting procedure eliminates computational barriers and should enable real-time processing of CDMS data on a laptop computer.


Asunto(s)
Análisis de Datos , Análisis de Fourier , Espectrometría de Masas/métodos , Iones/química
16.
Anal Chem ; 94(33): 11703-11712, 2022 08 23.
Artículo en Inglés | MEDLINE | ID: mdl-35961005

RESUMEN

Instrumental resolution of Fourier transform-charge detection mass spectrometry instruments with electrostatic ion trap detection of individual ions depends on the precision with which ion energy is determined. Energy can be selected using ion optic filters or from harmonic amplitude ratios (HARs) that provide Fellgett's advantage and eliminate the necessity of ion transmission loss to improve resolution. Unlike the ion energy-filtering method, the resolution of the HAR method increases with charge (improved S/N) and thus with mass. An analysis of the HAR method with current instrumentation indicates that higher resolution can be obtained with the HAR method than the best resolution demonstrated for instruments with energy-selective optics for ions in the low MDa range and above. However, this gain is typically unrealized because the resolution obtainable with molecular systems in this mass range is limited by sample heterogeneity. This phenomenon is illustrated with both tobacco mosaic virus (0.6-2.7 MDa) and AAV9 (3.7-4.7 MDa) samples where mass spectral resolution is limited by the sample, including salt adducts, and not by instrument resolution. Nevertheless, the ratio of full to empty AAV9 capsids and the included genome mass can be accurately obtained in a few minutes from 1× PBS buffer solution and an elution buffer containing 300+ mM nonvolatile content despite extensive adduction and lower resolution. Empty and full capsids adduct similarly indicating that salts encrust the complexes during late stages of droplet evaporation and that mass shifts can be calibrated in order to obtain accurate analyte masses even from highly salty solutions.


Asunto(s)
Espectrometría de Masas , Cápside , Análisis de Fourier , Iones/química , Espectrometría de Masas/métodos , Electricidad Estática
17.
J Am Soc Mass Spectrom ; 33(3): 607-611, 2022 Mar 02.
Artículo en Inglés | MEDLINE | ID: mdl-35157433

RESUMEN

Nanoelectrospray ionization emitters with submicron tip diameters have significant advantages for use in native mass spectrometry, including the ability to produce resolved charge-state distributions for proteins and macromolecular complexes from standard biochemical buffers that contain high concentrations of nonvolatile salts and to prevent nonspecific aggregation that can occur during droplet evaporation. We report on various factors affecting the tip morphology and provide suggestions for producing and using emitters with submicron tips. Effects of pulling parameters for a Sutter Instrument P-87 tip puller on the resulting tip diameter and morphology are shown. The "Pull" parameter has the largest effect on tip diameter, followed by "Velocity", "Pressure", and "Heat", whereas the "Time" parameter has minimal effect beyond a lower threshold. High "Pull" values generate emitters with multiple tapers, whereas high "Velocity" values generate a tip with only a single tapered region. A protocol for producing reproducible emitters in the submicron size range, as well as guidelines and tips for using these emitters with standard biochemical buffers that contain high concentrations of nonvolatile salts, is presented with the aim of expanding their use within the native mass spectrometry community.

18.
Analyst ; 146(22): 6822-6830, 2021 Nov 08.
Artículo en Inglés | MEDLINE | ID: mdl-34668895

RESUMEN

The ability of electrospray emitters with submicron tip diameters to significantly reduce and even eliminate aggregation of analyte molecules that can occur inside evaporating droplets was recently demonstrated to show that serine octamer exists in bulk solution, albeit in low abundance. Results using 222 nm emitter tips for D-serine and deuterium labeled L-serine show that the serine octamer that exists in 100 µM solution has a strong homochiral preference. Dissociation of large multiply protonated clusters results in formation of protonated octamer through a doubly protonated decamer intermediate. Remarkably, dissociation of the doubly protonated decamer from solution, which has a heterochiral preference, results in protonated octamer with strong homochiral preference. This homochiral preference is higher when protonated octamer is formed from larger clusters and approaches the chiral preference of the octamer in solution. These results show that the doubly protonated decamer has a different structure when formed from solution than when formed by dissociation of larger clusters. These results indicate that the unusually high abundance of protonated homochiral octamer formed by spray ionization methods that has been reported previously can be largely attributed to aggregation of serine that occurs in rapidly evaporating droplets and from dissociation of large clusters that form abundant protonated octamer at an optimized effective temperature.


Asunto(s)
Gases , Serina , Espectrometría de Masa por Ionización de Electrospray
19.
Chem Sci ; 12(14): 5185-5195, 2021 Feb 27.
Artículo en Inglés | MEDLINE | ID: mdl-34168773

RESUMEN

Mechanistic information about how gaseous ions are formed from charged droplets has been difficult to establish because direct observation of nanodrops in a size range relevant to gaseous macromolecular ion formation by optical or traditional mass spectrometry methods is challenging owing to their small size and heterogeneity. Here, the mass and charge of individual aqueous nanodrops between 1-10 MDa (15-32 nm diameter) with ∼50-300 charges are dynamically monitored for 1 s using charge detection mass spectrometry. Discrete losses of minimally solvated singly charged ions occur, marking the first direct observation of ion emission from aqueous nanodrops in late stages of droplet evaporation relevant to macromolecular ion formation in native mass spectrometry. Nanodrop charge depends on the identity of constituent ions, with pure water nanodrops charged slightly above the Rayleigh limit and aqueous solutions containing alkali metal ions charged progressively below the Rayleigh limit with increasing cation size. MS2 capsid ions (∼3.5 MDa; ∼27 nm diameter) are more highly charged from aqueous ammonium acetate than from its biochemically preferred, 100 mM NaCl/10 mM Na phosphate solution, consistent with ion emission reducing the nanodrop and resulting capsid charge. The extent of charging indicates that the capsid partially collapses inside the nanodrops prior to the charging and formation of the dehydrated gaseous ions. These results demonstrate that ion emission can affect macromolecular charging and that conformational changes to macromolecular structure can occur in nanodrops prior to the formation of naked gaseous ions.

20.
Analyst ; 146(8): 2617-2625, 2021 Apr 26.
Artículo en Inglés | MEDLINE | ID: mdl-33688888

RESUMEN

Protonated serine octamer is especially abundant in spray ionization mass spectra of serine solutions under a wide range of conditions. Although serine octamer exists in low abundance in solution, abundant clusters, including octamer, can be formed by aggregation inside evaporating electrospray droplets. A minimum cluster size of 8 and 21 serine molecules was observed for doubly protonated and triply protonated clusters, respectively, formed by electrospray ionization of a 10 mM serine solution. Dissociation of these clusters results in charge separation to produce predominantly protonated serine dimer and some trimer and the complimentary charged ion. Dissociation of clusters significantly larger than the minimum cluster size occurs by sequential loss of serine molecules. Dissociation of all large clusters investigated leads to protonated octamer as the second most abundant cluster (protonated dimer is most abundant) at optimized collision energies. All larger clusters dissociate through a combination of charge separation and neutral serine loss to form small doubly protonated clusters, and the vast majority of protonated octamer is produced by dissociation of the doubly protonated decamer by charge separation. Protonated octamer abundance is optimized at a uniform energy per degrees of freedom for all clusters indicating that simultaneous dissociation of all large clusters will lead to abundant protonated octamer at an optimum ion temperature. These results provide evidence for another route to formation of abundant protonated octamer in spray ionization or other methods that promote formation and subsequent dissociation of large clusters.