Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Microbiol Spectr ; 10(6): e0280822, 2022 12 21.
Artículo en Inglés | MEDLINE | ID: mdl-36374034

RESUMEN

The incidence of tickborne infections in the United States has risen significantly. Automation is needed for the increasing demand for testing. The Panther Fusion (Fusion) has an Open Access functionality to perform lab developed tests (LDTs) on a fully automated system. Our laboratory adapted two LDTs on Fusion; a multiplex real-time PCR for Anaplasma phagocytophilum and Ehrlichia chaffeensis (AP/EC) and a Babesia microti (BM) PCR. Limits of detection (LODs) were performed with target region plasmid panels spiked into whole blood. The LODs for AP, BM, and EC on the Fusion were 11, 17, and 10 copies/reaction, respectively. The performance of AP/EC was evaluated with 80 whole blood specimens, including 50 specimens previously positive for AP by our test of record (TOR) and 30 specimens (including 20 AP positive) spiked with EC plasmid. AP was detected in 49 out of 50 positive specimens and EC was detected in all 30 spiked specimens. BM PCR on Fusion was evaluated with 75 whole blood samples, including 16 specimens previously shown to be positive for BM and 59 negative specimens, of which 29 were spiked with BM plasmid DNA. BM was detected in 45 samples as expected. AP/EC and BM PCRs were successfully developed and optimized on the Panther Fusion with performance characteristics comparable to our TOR. These assays complement each other and allow for a modular testing approach for tickborne diseases which have differing clinical presentation. Furthermore, automation of these assays will help the lab meet the increasing demand for testing. IMPORTANCE Since the incidence of tickborne diseases has been accelerating in the United States, automation for testing has become essential in affected regions. Unfortunately, because the need is regional, commercial test manufacturers have not yet provided answers for clinical laboratories. Here, we describe the development of PCR tests on the highly automated Panther Fusion for three tickborne diseases. The Panther Fusion assays were evaluated using 155 archived whole blood (WB) specimens previously tested for Anaplasma phagocytophilum, Ehrlichia chaffeensis, and Babesia microti, while WB spiked with DNA from plasmid clones of the target regions were used for analytical sensitivity. We demonstrated that the Panther Fusion assays performed similar to the manual PCR tests used clinically in our laboratory and that automation of these tests had no adverse effect on the performance.


Asunto(s)
Anaplasma phagocytophilum , Enfermedades por Picaduras de Garrapatas , Humanos , Reacción en Cadena en Tiempo Real de la Polimerasa , Acceso a la Información , Anaplasma phagocytophilum/genética , Técnicas de Amplificación de Ácido Nucleico , Límite de Detección , Enfermedades por Picaduras de Garrapatas/diagnóstico
2.
J Clin Virol ; 121: 104204, 2019 12.
Artículo en Inglés | MEDLINE | ID: mdl-31743836

RESUMEN

BACKGROUND: Nucleic acid amplification tests (NAATs), such as PCR, are preferred for respiratory virus testing, due to superior diagnostic accuracy and faster turnaround time. Panther Fusion® Respiratory Assays (Fusion), which includes FluA/B/RSV (FFABR), Paraflu and AdV/hMPV/RV, offers a modular approach to syndromic testing on a fully automated platform while improving gene targets and expanding the test menu. OBJECTIVES AND STUDY DESIGN: We evaluated Fusion using 275 consecutive nasopharyngeal specimens previously used in an analysis of five PCRs, as well as 225 archived specimens. RESULTS: Of the combined 500 specimens, 134 were positive for influenza A (FluA), 54 for FluB, 65 for RSV, 64 for parainfluenza (PIV), 24 for adenovirus (AdV), 21 for humanmetapneumovirus (hMPV), and 40 for rhinovirus (RV) with Fusion. Of the positive samples Fusion correlated with historical results for all but one, despite multiple freeze-thaws cycles of this collection. Fusion was positive for an additional 33 samples, including 11 FluAs, 7 RSVs, 3 PIV3s, 3 AdV, 6 hMPV and 3 RVs. These samples were retested with corresponding Prodesse (Pro) assays using quadruple sample volume. This resolver test confirmed Fusion results for an additional 4 FluAs, 4 RSVs, 1 PIV3 and 3 AdVs. The sensitivity and specificity ranges of Fusion were 99-100% and 98-100%. Limit of detection (LOD) analyses were performed on a variety of Flu isolates. The LODs ranged from 2.69 to 2.99 log copies/ml and demonstrated superior LOD as compared to previously published data for some assays or to concurrent analyses with two new commercial tests.


Asunto(s)
Técnicas de Amplificación de Ácido Nucleico/métodos , Infecciones del Sistema Respiratorio/diagnóstico , Virosis/diagnóstico , Virus/aislamiento & purificación , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Automatización de Laboratorios , Niño , Preescolar , Femenino , Humanos , Lactante , Recién Nacido , Límite de Detección , Masculino , Persona de Mediana Edad , Nasofaringe/virología , Técnicas de Amplificación de Ácido Nucleico/instrumentación , Infecciones del Sistema Respiratorio/virología , Sensibilidad y Especificidad , Virosis/virología , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...