Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 40
Filtrar
1.
Sci Rep ; 14(1): 5638, 2024 03 07.
Artículo en Inglés | MEDLINE | ID: mdl-38454051

RESUMEN

Transperineal fusion prostate biopsy has a considerable learning curve (LC). Robotic-assisted transperineal MRI/Ultrasound fusion-guided biopsy (RA-TP-FBx) may have an easier LC due to automatization. We aimed to assess the LC of RA-TP-FBx and analyze its most difficult steps. We prospectively analyzed cases randomized to a biopsy-naïve urology resident, the chief resident, and an expert urologist in RA-TP-FBx (controls). We also analyzed consecutive cases in the LC of the expert. The LC was defined by procedure time, PCa detection rate (including stratification by PI-RADS), entrustable professional activities (EPA) assessment scores, and the NASA task load index. We collectively performed 246 RA-TP-FBx with the Mona Lisa device. Procedure time for residents decreased steeply from maximum 53 min to minimum 10 min, while the mean procedure time for the expert was 9 min (range 17-5 min). PCa detection for PI-RADS-4 lesions was 57% for the naïve resident, 61% for the chief resident and 62% for the expert. There was also no difference in Pca detection for PI-RADS-4 lesions when comparing the first and second half of the experts' biopsies (p = 0.8). Maximum EPA score was registered after 22 cases. Workload steeply declined. Proficient RA-TP-FBx performance appears feasible after 22 cases regardless of previous experience.


Asunto(s)
Neoplasias de la Próstata , Procedimientos Quirúrgicos Robotizados , Masculino , Humanos , Próstata/diagnóstico por imagen , Próstata/patología , Neoplasias de la Próstata/patología , Imagen por Resonancia Magnética/métodos , Curva de Aprendizaje , Biopsia Guiada por Imagen/métodos
2.
Eur J Cardiothorac Surg ; 65(3)2024 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-38310332

RESUMEN

OBJECTIVES: The aortic root (AoR) rotation and its spatial morphology at the base of the heart were postulated but not described in every detail. AoR rotation modalities may play an important role in decision-making during AoR surgery and its outcome. The aim was to provide a detailed spatial anatomy of the AoR rotation and its relation to the vital surrounding structure. METHODS: The AoR rotation and its relation to the surrounding structure were assessed in 104 patients with tricuspid aortic valve. The interatrial septum was chosen as a reference to describe AoR rotation that marked the midline of the heart base as a landmark for the AoR rotation direction. Intermediate, clockwise and counterclockwise AoR rotations were defined based on the mentioned reference structures. RESULTS: The AoR rotation was successfully assessed in 104 patients undergoing ascending aorta and or AoR intervention by multidetector row computed tomography. AoR was positioned normally in 53.8% of cases (n = 56) and rotated counterclockwise in 5.8% (n = 6) and clockwise in 40.4% (n = 42) of cases. In clockwise AoR rotation, the right coronary sinus was positioned in proximity to the right atrium and of the tricuspid valve, whereas in a counterclockwise rotation, the noncoronary sinus was placed over the tricuspid valve just over the membranous septum. CONCLUSIONS: The AoR's rotation can be diagnosed using multidetector row computed tomography. Understanding the anatomy of the aortic valve related to rotational position helps guide surgical decision-making in performing AoR reconstruction.


Asunto(s)
Aorta Torácica , Aorta , Humanos , Aorta/cirugía , Válvula Aórtica/cirugía , Válvula Tricúspide , Tomografía Computarizada Multidetector
3.
Eur Urol Focus ; 2024 Feb 23.
Artículo en Inglés | MEDLINE | ID: mdl-38402105

RESUMEN

BACKGROUND: This study investigates the use of biparametric magnetic resonance imaging (bpMRI) as primary opportunistic screening for prostate cancer (PCa) without using a prostate-specific antigen (PSA) cut-off. OBJECTIVE: The primary endpoint was to assess the efforts and effectiveness of identifying 20 participants with clinically significant prostate cancer (csPCa) using bpMRI. DESIGN, SETTING, AND PARTICIPANTS: Biopsy-naïve men aged over 45 yr were included. All participants underwent 3 Tesla bpMRI, PSA, and digital rectal examination (DRE). Targeted-only biopsy was performed in participants with Prostate Imaging Reporting and Data System (PI-RADS) ≥3. Men with negative bpMRI but suspicious DRE or elevated PSA/PSA density had template biopsies. Preintended protocol adjustments were made after an interim analysis for PI-RADS 3 lesions: no biopsy and follow-up MRI after 6 mo and biopsy only if lesions persisted or upgraded. OUTCOME MEASUREMENTS AND STATISTICAL ANALYSIS: Biopsy results underwent a comparison using Fisher's exact test and univariable logistic regression to identify prognostic factors for positive biopsy. RESULTS AND LIMITATIONS: A total of 229 men were enrolled in this study, of whom 79 underwent biopsy. Among these men, 77 displayed suspicious PI-RADS lesions. PCa was detected in 29 participants (12.7%), of whom 21 had csPCa (9.2%). Biparametric MRI detected 21 csPCa cases, while PSA and DRE would have missed 38.1%. Protocol adjustment led to a 54.6% biopsy reduction in PI-RADS 3 lesions. Overall, in this cohort of men with a median PSA value of 1.26 ng/ml, 10.9 bpMRI scans were needed to identify one participant with csPCa. A major limitation of the study is the lack of a control cohort undergoing systematic biopsies. CONCLUSIONS: Opportunistic screening utilising bpMRI as a primary tool has higher sensitivity in detecting csPCa than classical screening methods. PATIENT SUMMARY: Screening with biparametric magnetic resonance imaging (bpMRI) and targeted biopsy identified clinically significant prostate cancer in every 11th man, regardless of the prostate-specific antigen (PSA) levels. Preselecting patients based on PSA >1 ng/ml and a positive family history of prostate cancer, as well as other potential blood tests may further improve the effectiveness of bpMRI in this setting.

4.
Struct Heart ; 8(1): 100229, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38283571

RESUMEN

The increasing use of transcatheter aortic valves in patients with aortic stenosis has led to a higher number of valve-in-valve procedures due to gradual valve degeneration. We present a case of a 72-year-old woman who received transcatheter aortic valve implantation (TAVI) using a Lotus valve due to severe aortic stenosis, which showed valve degeneration several years after the initial procedure. After heart-team discussion, TAVI-in-TAVI was planned using an Evolut pro+ valve, which allowed for full coverage of the Lotus valve and maintenance of coronary flow, resulting in a well-functioning valve with no regurgitation and normal performance. Despite high-risk anatomic features, valve-in-valve using an Evolut pro+ in a degenerated Lotus valve is feasible and overcomes pitfalls such as entanglement or coronary obstruction.

5.
Quant Imaging Med Surg ; 13(7): 4284-4294, 2023 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-37456296

RESUMEN

Background: Diffuse parenchymal liver diseases are contributing substantially to global morbidity and represent major causes of deaths worldwide. The aim of our study is to assess whether established hepatic fat and iron quantitation and relaxometry-based quantification of hepatocyte-specific contrast material as surrogate for liver function estimation allows to evaluate liver fibrosis. Methods: Retrospective consecutive study. Seventy-two healthy patients (mean age: 53 years) without known liver disease, 21 patients with temporary elevated liver enzymes (mean: 65 years) and 109 patients with biopsy proven liver fibrosis or cirrhosis (mean: 61 years), who underwent liver magnetic resonance imaging (MRI) with a hepatocyte-specific contrast agent [gadoxetate disodium, gadolinium ethoxybenzyl-diethylenetriaminepentaacetic acid (Gd-EOB-DTPA), 0.25 mmol/mL Primovist, Bayer AG, Leverkusen, Germany] at 1.5 T (n=133) and at 3 T (n=69), were included. Fibrosis was classified using the histopathological meta-analysis of histological data in viral hepatitis (METAVIR) and the clinical Child-Pugh scores. Gd-concentration were quantified using T1 map-based calculations. Gd-concentration mapping was performed by using a Look-Locker approach prior to and 912±159 s after intravenous administration of hepatocyte specific contrast agent. Additionally, parenchymal fat fraction, R2*, bilirubin, gender and age were defined as predicting factors. Diagnostic accuracy was calculated in a monoparametric (linear regression, predictor: Gd-concentration) and multiparametric model (predictors: age, bilirubin level, iron overload, liver fat fraction, Gd concentration in the left and right liver lobe). Results: Mean Gd-concentration in the liver parenchyma was significantly higher for healthy patients ([Gd] =0.51 µmol/L) than for those with liver fibrosis or cirrhosis ([Gd] =0.31 µmol/L; P<0.0001) and with acute liver disease ([Gd] =0.28 µmol/L), though there were no significant differences for the latter two groups. There was a significant moderate negative correlation for the mean Gd-concentration and the METAVIR score (ρ=-0.44, P<0.0001) as well as for the Child-Pugh stage (ρ=-0.35, P<0.0001). There was a significant strong correlation between the bilirubin concentration and the Gd-concentration (ρ=-0.61, P<0.0001). The diagnostic accuracy for the discrimination of healthy patients and patients with known fibrosis or cirrhosis was 0.74 (0.71/0.60 sensitivity/specificity) in a monoparametric and 0.76 (0.85/0.61 sensitivity/specificity) in a machine learning based multiparametric model. Conclusions: T1 mapping-based quantification of hepatic Gd-EOB-DTPA concentrations performed in a multiparametric model shows promising diagnostic accuracy for the detection of fibrotic changes. Liver biopsy might be replaced by imaging examinations.

6.
Int J Clin Pract ; 2023: 7450009, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37383705

RESUMEN

Background: Dizziness is a frequent presentation in patients presenting to emergency departments (EDs), often triggering extensive work-up, including neuroimaging. Therefore, gathering knowledge on final diagnoses and outcomes is important. We aimed to describe the incidence of dizziness as primary or secondary complaint, to list final diagnoses, and to determine the use and yield of neuroimaging and outcomes in these patients. Methods: Secondary analysis of two observational cohort studies, including all patients presenting to the ED of the University Hospital of Basel from 30th January 2017-19th February 2017 and from 18th March 2019-20th May 2019. Baseline demographics, Emergency Severity Index (ESI), hospitalization, admission to Intensive Care Units (ICUs), and mortality were extracted from the electronic health record database. At presentation, patients underwent a structured interview about their symptoms, defining their primary and secondary complaints. Neuroimaging results were obtained from the picture archiving and communication system (PACS). Patients were categorized into three non-overlapping groups: dizziness as primary complaint, dizziness as secondary complaint, and absence of dizziness. Results: Of 10076 presentations, 232 (2.3%) indicated dizziness as their primary and 984 (9.8%) as their secondary complaint. In dizziness as primary complaint, the three (out of 73 main conditions defined) main diagnoses were nonspecific dizziness (47, 20.3%), dysfunction of the peripheral vestibular system (37, 15.9%), as well as somatization, depression, and anxiety (20, 8.6%). 104 of 232 patients (44.8%) underwent neuroimaging, with relevant findings in 5 (4.8%). In dizziness as primary complaint 30-day mortality was 0%. Conclusion: Work-up for dizziness in emergency presentations has to consider a broad differential diagnosis, but due to the low yield, it should include neuroimaging only in few and selected cases, particularly with additional neurological abnormalities. Presentation with primary dizziness carries a generally favorable prognosis lacking short-term mortality. .


Asunto(s)
Ansiedad , Mareo , Humanos , Trastornos de Ansiedad , Bases de Datos Factuales , Diagnóstico Diferencial
7.
J Clin Med ; 12(9)2023 Apr 25.
Artículo en Inglés | MEDLINE | ID: mdl-37176563

RESUMEN

Hypertensive heart disease (HHD) develops in response to the chronic exposure of the left ventricle and left atrium to elevated systemic blood pressure. Left ventricular structural changes include hypertrophy and interstitial fibrosis that in turn lead to functional changes including diastolic dysfunction and impaired left atrial and LV mechanical function. Ultimately, these changes can lead to heart failure with a preserved (HFpEF) or reduced (HFrEF) ejection fraction. This review will outline the clinical evaluation of a patient with hypertension and/or suspected HHD, with a particular emphasis on the role and recent advances of multimodality imaging in both diagnosis and differential diagnosis.

8.
Am J Cardiovasc Dis ; 13(2): 73-86, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37213319

RESUMEN

AIMS: No data is available about the significance of cardiovascular magnetic resonance (CMR) derived vascular distensibility (VD) and vessel wall ratio (VWR) for risk stratification in patients with type 2 diabetes mellitus (T2DM). Therefore, this study aimed to investigate the effects of T2DM on VD and VWR using CMR in both central and peripheral territories. METHODS: Thirty-one T2DM-patients and nine controls underwent CMR. Angulation of the aorta, the common carotid, and the coronary arteries was performed to obtain cross-sectional vessel areas. RESULTS: In T2DM the Carotid-VWR and the Aortic-VWR correlated significantly. Mean values of Carotid-VWR and Aortic-VWR were significantly higher in T2DM than in controls. Coronary-VD was significantly lower in T2DM than in controls. No significant difference in Carotid-VD or Aortic-VD in T2DM vs. controls, respectively, could be observed. In a subgroup of thirteen T2DM patients with coronary artery disease (CAD), Coronary-VD was significantly lower and Aortic-VWR was significantly higher compared to T2DM patients without CAD. CONCLUSION: CMR allows a simultaneous evaluation of the structure and function of three important vascular territories to detect vascular remodeling in T2DM.

9.
Abdom Radiol (NY) ; 48(4): 1329-1339, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-36732406

RESUMEN

PURPOSE: To assess whether high temporal/spatial resolution GRASP MRI acquired during routine clinical imaging can identify several degrees of renal function impairment referenced against renal dynamic scintigraphy. METHODS: This retrospective study consists of method development and method verification parts. During method development, patients subject to renal imaging using gadoterate meglumine and GRASP post-contrast MRI technique (TR/TE 3.3/1.6 ms; FoV320 × 320 mm; FA12°; Voxel1.1 × 1.1x2.5 mm) were matched into four equally-sized renal function groups (no-mild-moderate-severe impairment) according to their laboratory-determined estimated glomerular filtration rates (eGFR); 60|120 patients|kidneys were included. Regions-of-interest (ROIs) were placed on cortices, medullary pyramids and collecting systems of bilateral kidneys. Cortical perfusion, tubular concentration and collecting system excretion were determined as TimeCortex=Pyramid(sec), SlopeTubuli (sec-1), and TimeCollecting System (sec), respectively, and were measured by a combination of extraction of time intensity curves and respective quantitative parameters. For method verification, patients subject to GRASP MRI and renal dynamic scintigraphy (99mTc-MAG3, 100 MBq/patient) were matched into three renal function groups (no-mild/moderate-severe impairment). Split renal function parameters post 1.5-2.5 min as well as MAG3 TER were correlated with time intensity parameters retrieved using GRASP technique; 15|30 patients|kidneys were included. RESULTS: Method development showed differing values for TimeCortex=Pyramid(71|75|93|122 s), SlopeTubuli(2.6|2.1|1.3|0.5 s-1) and TimeCollecting System(90|111|129|139 s) for the four renal function groups with partial significant tendencies (several p-values < 0.001). In method verification, 29/30 kidneys (96.7%) were assigned to the correct renal function group. CONCLUSION: High temporal and spatial resolution GRASP MR imaging allows to identify several degrees of renal function impairment using routine clinical imaging with a high degree of accuracy.


Asunto(s)
Medios de Contraste , Interpretación de Imagen Asistida por Computador , Humanos , Estudios de Factibilidad , Estudios Retrospectivos , Interpretación de Imagen Asistida por Computador/métodos , Riñón/diagnóstico por imagen , Riñón/fisiología , Imagen por Resonancia Magnética/métodos , Cintigrafía
10.
Cancer Imaging ; 23(1): 6, 2023 Jan 17.
Artículo en Inglés | MEDLINE | ID: mdl-36647150

RESUMEN

BACKGROUND: Deep-learning-based computer-aided diagnosis (DL-CAD) systems using MRI for prostate cancer (PCa) detection have demonstrated good performance. Nevertheless, DL-CAD systems are vulnerable to high heterogeneities in DWI, which can interfere with DL-CAD assessments and impair performance. This study aims to compare PCa detection of DL-CAD between zoomed-field-of-view echo-planar DWI (z-DWI) and full-field-of-view DWI (f-DWI) and find the risk factors affecting DL-CAD diagnostic efficiency. METHODS: This retrospective study enrolled 354 consecutive participants who underwent MRI including T2WI, f-DWI, and z-DWI because of clinically suspected PCa. A DL-CAD was used to compare the performance of f-DWI and z-DWI both on a patient level and lesion level. We used the area under the curve (AUC) of receiver operating characteristics analysis and alternative free-response receiver operating characteristics analysis to compare the performances of DL-CAD using f- DWI and z-DWI. The risk factors affecting the DL-CAD were analyzed using logistic regression analyses. P values less than 0.05 were considered statistically significant. RESULTS: DL-CAD with z-DWI had a significantly better overall accuracy than that with f-DWI both on patient level and lesion level (AUCpatient: 0.89 vs. 0.86; AUClesion: 0.86 vs. 0.76; P < .001). The contrast-to-noise ratio (CNR) of lesions in DWI was an independent risk factor of false positives (odds ratio [OR] = 1.12; P < .001). Rectal susceptibility artifacts, lesion diameter, and apparent diffusion coefficients (ADC) were independent risk factors of both false positives (ORrectal susceptibility artifact = 5.46; ORdiameter, = 1.12; ORADC = 0.998; all P < .001) and false negatives (ORrectal susceptibility artifact = 3.31; ORdiameter = 0.82; ORADC = 1.007; all P ≤ .03) of DL-CAD. CONCLUSIONS: Z-DWI has potential to improve the detection performance of a prostate MRI based DL-CAD. TRIAL REGISTRATION: ChiCTR, NO. ChiCTR2100041834 . Registered 7 January 2021.


Asunto(s)
Aprendizaje Profundo , Neoplasias de la Próstata , Masculino , Humanos , Estudios Retrospectivos , Reproducibilidad de los Resultados , Neoplasias de la Próstata/diagnóstico por imagen , Neoplasias de la Próstata/patología , Imagen por Resonancia Magnética/métodos , Imagen de Difusión por Resonancia Magnética/métodos
11.
Eur Heart J Cardiovasc Imaging ; 24(8): 1062-1071, 2023 07 24.
Artículo en Inglés | MEDLINE | ID: mdl-36662127

RESUMEN

AIMS: Pulmonary transit time (PTT) is the time blood takes to pass from the right ventricle to the left ventricle via pulmonary circulation. We aimed to quantify PTT in routine cardiovascular magnetic resonance imaging perfusion sequences. PTT may help in the diagnostic assessment and characterization of patients with unclear dyspnoea or heart failure (HF). METHODS AND RESULTS: We evaluated routine stress perfusion cardiovascular magnetic resonance scans in 352 patients, including an assessment of PTT. Eighty-six of these patients also had simultaneous quantification of N-terminal pro-brain natriuretic peptide (NTproBNP). NT-proBNP is an established blood biomarker for quantifying ventricular filling pressure in patients with presumed HF. Manually assessed PTT demonstrated low inter-rater variability with a correlation between raters >0.98. PTT was obtained automatically and correctly in 266 patients using artificial intelligence. The median PTT of 182 patients with both left and right ventricular ejection fraction >50% amounted to 6.8 s (Pulmonary transit time: 5.9-7.9 s). PTT was significantly higher in patients with reduced left ventricular ejection fraction (<40%; P < 0.001) and right ventricular ejection fraction (<40%; P < 0.0001). The area under the receiver operating characteristics curve (AUC) of PTT for exclusion of HF (NT-proBNP <125 ng/L) was 0.73 (P < 0.001) with a specificity of 77% and sensitivity of 70%. The AUC of PTT for the inclusion of HF (NT-proBNP >600 ng/L) was 0.70 (P < 0.001) with a specificity of 78% and sensitivity of 61%. CONCLUSION: PTT as an easily, even automatically obtainable and robust non-invasive biomarker of haemodynamics might help in the evaluation of patients with dyspnoea and HF.


Asunto(s)
Inteligencia Artificial , Insuficiencia Cardíaca , Humanos , Volumen Sistólico , Función Ventricular Izquierda , Función Ventricular Derecha , Péptido Natriurético Encefálico , Biomarcadores , Hemodinámica , Disnea , Fragmentos de Péptidos , Espectroscopía de Resonancia Magnética
12.
Radiol Case Rep ; 18(2): 657-660, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-36504879

RESUMEN

A rare case of a previously treated thoraco-abdominal aortic aneurysm eroding into the thoracic spine is described. Initially, several follow-up CT angiography scans showed an increasing aneurysm sack, but no endoleak could be depicted. Then, a new rapidly developing erosion into the thoracic spine was noted. MRI imaging excluded any other underlying infectious or malignant process. Additional contrast-enhanced ultrasound excluded an endoleak. A 3D-printed model of the aneurysm and spine and cinematic renderings were created to improve visualization. She underwent relining of the thoracic stent graft. Follow-up imaging showed a stable aneurysm size and no progression of the vertebral erosions.

13.
Andrology ; 11(6): 1009-1015, 2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-36427333

RESUMEN

BACKGROUND: Prostate biopsy represents one of the most frequently performed urologic procedures worldwide and therefore presupposes knowledge on potential effects like on the erectile function, especially in extensive or repeated biopsies. The robotic-assisted biopsy system (Mona Lisa) offers a minimal invasive approach via only two incision points ensuring maximal accuracy combined with protection of the neurovascular bundle of the prostate. OBJECTIVE: Our purpose was to analyse the impact of robotic-assisted transperineal biopsy of the prostate on the erectile function. METHODS: Our prospective study analyses the outcomes of 210 patients, who had undergone minimal-invasive, transperineal robotic-assisted biopsy of the prostate at the University Hospital Basel from January 2020 to March 2022 and provided sufficient data. Of these, 157 (74.8%) were included in final analysis. RESULTS: Mean (range) age, prostate volume, PSA and IIEF-5 score at baseline were 63.8 years (46.1-83.6), 46.4 ml (9-310), 13.2 ng/ml (0.2-561), and 18.8 points (6-25), respectively. EF before and 1 month after intervention was assessed with the IIEF-5 questionnaire for the whole cohort. No significant change of IIEF-5 was observed for the whole cohort with a mean (± SD) decrease of 0.4 (± 3.1) points. Except for patients > 69 years, subgroup analysis revealed no change of IIEF-5 in statistically significant manner for all subgroups. Number of biopsy cores (< 20 and ≥ 20), previous biopsies and active surveillance showed no significant influence. CONCLUSION: Our results suggest that the minimally invasive and highly precise robotic technique can spare the erectile function without limiting the extent of biopsy and without compromising diagnostic accuracy.


Asunto(s)
Disfunción Eréctil , Neoplasias de la Próstata , Procedimientos Quirúrgicos Robotizados , Masculino , Humanos , Persona de Mediana Edad , Próstata/patología , Neoplasias de la Próstata/cirugía , Neoplasias de la Próstata/patología , Estudios Prospectivos , Biopsia/métodos
14.
Eur Radiol ; 33(1): 64-76, 2023 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-35900376

RESUMEN

OBJECTIVES: To evaluate the effect of a deep learning-based computer-aided diagnosis (DL-CAD) system on experienced and less-experienced radiologists in reading prostate mpMRI. METHODS: In this retrospective, multi-reader multi-case study, a consecutive set of 184 patients examined between 01/2018 and 08/2019 were enrolled. Ground truth was combined targeted and 12-core systematic transrectal ultrasound-guided biopsy. Four radiologists, two experienced and two less-experienced, evaluated each case twice, once without (DL-CAD-) and once assisted by DL-CAD (DL-CAD+). ROC analysis, sensitivities, specificities, PPV and NPV were calculated to compare the diagnostic accuracy for the diagnosis of prostate cancer (PCa) between the two groups (DL-CAD- vs. DL-CAD+). Spearman's correlation coefficients were evaluated to assess the relationship between PI-RADS category and Gleason score (GS). Also, the median reading times were compared for the two reading groups. RESULTS: In total, 172 patients were included in the final analysis. With DL-CAD assistance, the overall AUC of the less-experienced radiologists increased significantly from 0.66 to 0.80 (p = 0.001; cutoff ISUP GG ≥ 1) and from 0.68 to 0.80 (p = 0.002; cutoff ISUP GG ≥ 2). Experienced radiologists showed an AUC increase from 0.81 to 0.86 (p = 0.146; cutoff ISUP GG ≥ 1) and from 0.81 to 0.84 (p = 0.433; cutoff ISUP GG ≥ 2). Furthermore, the correlation between PI-RADS category and GS improved significantly in the DL-CAD + group (0.45 vs. 0.57; p = 0.03), while the median reading time was reduced from 157 to 150 s (p = 0.023). CONCLUSIONS: DL-CAD assistance increased the mean detection performance, with the most significant benefit for the less-experienced radiologist; with the help of DL-CAD less-experienced radiologists reached performances comparable to that of experienced radiologists. KEY POINTS: • DL-CAD used as a concurrent reading aid helps radiologists to distinguish between benign and cancerous lesions in prostate MRI. • With the help of DL-CAD, less-experienced radiologists may achieve detection performances comparable to that of experienced radiologists. • DL-CAD assistance increases the correlation between PI-RADS category and cancer grade.


Asunto(s)
Aprendizaje Profundo , Imágenes de Resonancia Magnética Multiparamétrica , Neoplasias de la Próstata , Masculino , Humanos , Próstata/diagnóstico por imagen , Próstata/patología , Imagen por Resonancia Magnética , Estudios Retrospectivos , Neoplasias de la Próstata/patología , Clasificación del Tumor , Biopsia Guiada por Imagen , Radiólogos , Computadores
15.
Front Oncol ; 12: 1025355, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36531069

RESUMEN

Introduction: Robotic-assisted transperineal MRI-US-fusion guided biopsy of the prostate is a novel and highly accurate procedure. The aim of this study was to evaluate the MonaLisa prostate biopsy system in terms of safety, tolerability, and patient-related outcomes. Methods: This prospective study included 228 patients, who had undergone Robotic-assisted transperineal MRI-US-fusion guided biopsy of the prostate at the University Hospital Basel between January 2020 and June 2022. Peri-operative side effects, functional outcomes and patient satisfaction were assessed. Results: Mean pain score on the day of biopsy was 1.3 points on VAS, which remained constant on the day after biopsy. Overall, 32 of 228 patients (14%) developed grade I complications according to Clavien-Dindo classification. No higher-grade complications occurred. Gross haematuria, hematospermia and acute urinary retention occurred in 145/228 (63.6%), 98/228 (43%) and 32/228 (14%) patients, respectively. One patient (0.4%) developed urinary tract infection. Conclusions: Robotic-assisted transperineal MRI-US-fusion guided biopsy of the prostate performed under general anesthesia is a safe and well tolerated procedure. This technique allows to omit perioperative prophylaxis and at the same time minimizes the risk of infectious complications. We attribute the favorable risk profile and tolerability to the minimal invasive approach via two entry points.

16.
J Clin Med ; 11(22)2022 Nov 12.
Artículo en Inglés | MEDLINE | ID: mdl-36431182

RESUMEN

OBJECTIVES: The objectives of this study were to assess patient comfort when imaged on a newly introduced 0.55T low-field magnetic resonance (MR) scanner system with a wider bore opening compared to a conventional 1.5T MR scanner system. MATERIALS AND METHODS: In this prospective study, fifty patients (mean age: 66.2 ± 17.0 years, 22 females, 28 males) underwent subsequent magnetic resonance imaging (MRI) examinations with matched imaging protocols at 0.55T (MAGNETOM FreeMax, Siemens Healthineers; Erlangen, Germany) and 1.5T (MAGNETOM Avanto Fit, Siemens Healthineers; Erlangen, Germany) on the same day. MRI performed between 05/2021 and 07/2021 was included for analysis. The 0.55T MRI system had a bore opening of 80 cm, while the bore diameter of the 1.5T scanner system was 60 cm. Four patient groups were defined by imaged body regions: (1) cranial or cervical spine MRI using a head/neck coil (n = 27), (2) lumbar or thoracic spine MRI using only the in-table spine coils (n = 10), (3) hip MRI using a large flex coil (n = 8) and (4) upper- or lower-extremity MRI using small flex coils (n = 5). Following the MRI examinations, patients evaluated (1) sense of space, (2) noise level, (3) comfort, (4) coil comfort and (5) overall examination impression on a 5-point Likert-scale (range: 1= "much worse" to 5 = "much better") using a questionnaire. Maximum noise levels of all performed imaging studies were measured in decibels (dB) by a sound level meter placed in the bore center. RESULTS: Sense of space was perceived to be "better" or "much better" by 84% of patients for imaging examinations performed on the 0.55T MRI scanner system (mean score: 4.34 ± 0.75). Additionally, 84% of patients rated noise levels as "better" or "much better" when imaged on the low-field scanner system (mean score: 3.90 ± 0.61). Overall sensation during the imaging examination at 0.55T was rated as "better" or "much better" by 78% of patients (mean score: 3.96 ± 0.70). Quantitative assessment showed significantly reduced maximum noise levels for all 0.55T MRI studies, regardless of body region compared to 1.5T, i.e., brain MRI (83.8 ± 3.6 dB vs. 89.3 ± 5.4 dB; p = 0.04), spine MRI (83.7 ± 3.7 dB vs. 89.4 ± 2.6 dB; p = 0.004) and hip MRI (86.3 ± 5.0 dB vs. 89.1 ± 1.4 dB; p = 0.04). CONCLUSIONS: Patients perceived 0.55T new-generation low-field MRI to be more comfortable than conventional 1.5T MRI, given its larger bore opening and reduced noise levels during image acquisition. Therefore, new concepts regarding bore design and noise level reduction of MR scanner systems may help to reduce patient anxiety and improve well-being when undergoing MR imaging.

18.
Radiol Case Rep ; 17(3): 521-524, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-34976257

RESUMEN

In nature, basically 2 types of myocardial vascular patterns exist: the sinusoidal and the coronary type. In the sinusoidal type, the sinusoid is completely fed by blood coming directly from the ventricle through a spongy sinusoidal network. This pattern is found in cold-blooded animals and in the early embryologic development of human (warm-blooded) hearts. A 61-year-old man with atrial fibrillation developed severe tachymyopathy with a severely reduced left-ventricular ejection fraction (LVEF) of 20%. The patient had no history of prior heart surgery or other cardiac interventions. He was referred for a computed tomography (CT) scan for assessment of pulmonary vein anatomy prior to their isolation. Incidentally, a focal myocardial defect of the midventricular infero-septal wall with tail-like extension into the right ventricular cavity was detected. In a cardiac magnetic resonance (CMR) scan there was no evidence of a myocardial infarction or fibrosis. In the absence of a ventricular septal defect by CT, CMR and echocardiography the diagnosis of a persistent myocardial sinusoid was evident. In this case, we used state-of-the art methods for pathology visualization, illustrating the effectiveness of CT and CMR in the precise detection and differential diagnosis of myocardial anomalies including a multi-coloured 3D-printed model that may further enhance visuospatial appreciation of those anomalies.

19.
Eur Heart J Cardiovasc Imaging ; 23(6): 846-854, 2022 06 01.
Artículo en Inglés | MEDLINE | ID: mdl-34322693

RESUMEN

AIMS: To present and validate a fully automated, deep learning (DL)-based branch-wise coronary artery calcium (CAC) scoring algorithm on a multi-centre dataset. METHODS AND RESULTS: We retrospectively included 1171 patients referred for a CAC computed tomography examination. Total CAC scores for each case were manually evaluated by a human reader. Next, each dataset was fully automatically evaluated by the DL-based software solution with output of the total CAC score and sub-scores per coronary artery (CA) branch [right coronary artery (RCA), left main (LM), left anterior descending (LAD), and circumflex (CX)]. Three readers independently manually scored the CAC for all CA branches for 300 cases from a single centre and formed the consensus using a majority vote rule, serving as the reference standard. Established CAC cut-offs for the total Agatston score were used for risk group assignments. The performance of the algorithm was evaluated using metrics for risk class assignment based on total Agatston score, and unweighted Cohen's Kappa for branch label assignment. The DL-based software solution yielded a class accuracy of 93% (1085/1171) with a sensitivity, specificity, and accuracy of detecting non-zero coronary calcium being 97%, 93%, and 95%. The overall accuracy of the algorithm for branch label classification was 94% (LM: 89%, LAD: 91%, CX: 93%, RCA: 100%) with a Cohen's kappa of k = 0.91. CONCLUSION: Our results demonstrate that fully automated total and vessel-specific CAC scoring is feasible using a DL-based algorithm. There was a high agreement with the manually assessed total CAC from a multi-centre dataset and the vessel-specific scoring demonstrated consistent and reproducible results.


Asunto(s)
Enfermedad de la Arteria Coronaria , Aprendizaje Profundo , Calcio , Angiografía Coronaria/métodos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Vasos Coronarios/diagnóstico por imagen , Humanos , Estudios Retrospectivos
20.
Sci Rep ; 11(1): 20250, 2021 10 12.
Artículo en Inglés | MEDLINE | ID: mdl-34642448

RESUMEN

MRI-targeted prostate biopsy improves detection of clinically significant prostate cancer (PCa). However, up to 70% of PCa lesions display intralesional tumor heterogeneity. Current target sampling strategies do not yet adequately account for this finding. This prospective study included 118 patients who underwent transperineal robotic assisted biopsy of the prostate. We identified a total of 58 PCa-positive PI-RADS lesions. We compared diagnostic accuracy of a target-saturation biopsy strategy to accuracy of single, two, or three randomly selected targeted biopsy cores and analysed potential clinical implications. Intralesional detection of clinically significant cancer (ISUP ≥ 2) was 78.3% for target-saturation biopsy and 39.1%, 52.2%, and 67.4% for one, two, and three targeted cores, respectively. Target-saturation biopsies led to a more accurate characterization of PCa in terms of Gleason score and reduced rates of significant cancer missed. Compared to one, two, and three targeted biopsy cores, target-saturation biopsies led to intensified staging procedures in 21.7%, 10.9, and 8.7% of patients, and ultimately to a potential change in therapy in 39.1%, 26.1%, and 10.9% of patients. This work presents the concept of robotic-assisted target saturation biopsy. This technique has the potential to improve diagnostic accuracy and thus individual staging procedures and treatment decisions.


Asunto(s)
Biopsia con Aguja Gruesa/métodos , Biopsia Guiada por Imagen/métodos , Imagen por Resonancia Magnética Intervencional/métodos , Neoplasias de la Próstata/diagnóstico por imagen , Ultrasonografía Intervencional/métodos , Anciano , Anciano de 80 o más Años , Humanos , Masculino , Persona de Mediana Edad , Clasificación del Tumor , Estudios Prospectivos , Neoplasias de la Próstata/patología , Procedimientos Quirúrgicos Robotizados , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...