Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 208
Filtrar
1.
Spinal Cord ; 49(9): 1023-4, 2011 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-21468043

RESUMEN

STUDY DESIGN: The study design was a case report with 30-year follow-up. OBJECTIVES: In 1980, there were no pedicle screws available, so it was a great challenge to achieve correction and fusion in a patient with no laminae, and who was quadriplegic. Such a case with such a long follow-up has not been previously reported. METHODS: This is a single case report with an ultra-long follow-up. The patient underwent an anterior fusion from T3 to L4 via two incisions, and at a second stage, a posterior fusion from T3 to S1 using Luque rods and wires passed through the foramenae. After 2 years he underwent repair of two pseudarthroses with both anterior and posterior procedures. RESULTS: He achieved solid fusion following the pseudarthrosis repair. Although being a C7 quadriplegic all his life, he is totally independent in his activities of daily living, and is fully employed. CONCLUSION: Correction and fusion can be achieved even in the absence of laminae and pedicle screws.


Asunto(s)
Cifosis/etiología , Cifosis/cirugía , Laminectomía/efectos adversos , Cuadriplejía/complicaciones , Fusión Vertebral/métodos , Adulto , Estudios de Seguimiento , Humanos , Cifosis/diagnóstico por imagen , Laminectomía/métodos , Masculino , Radiografía , Reoperación/instrumentación , Reoperación/métodos , Fusión Vertebral/instrumentación
3.
J Orthop Surg (Hong Kong) ; 11(2): 202-6, 2003 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-14676348

RESUMEN

We report a case of degenerative L4-L5 spondylolisthesis in a 32-year-old female who had undergone thoracic (lower level T12) fusion as a teenager. All other levels in the lumbar spine were normal on magnetic resonance imaging. Subsequent fusion of L4-L5 led to improvement in function and alleviation of pain for more than 4 years. The possible relationship between the previous fusion and degenerative spondylolisthesis is discussed.


Asunto(s)
Vértebras Lumbares , Escoliosis/cirugía , Fusión Vertebral/efectos adversos , Espondilolistesis/etiología , Vértebras Torácicas , Adulto , Femenino , Humanos , Fusión Vertebral/métodos , Espondilolistesis/cirugía , Resultado del Tratamiento
5.
J Bone Joint Surg Am ; 83(1): 42-5, 2001 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-11205857

RESUMEN

BACKGROUND: The accuracy of measurement of curves in idiopathic scoliosis has been extensively studied; however, we know of only one article in the literature concerning the accuracy of measurement of curves in congenital scoliosis. That article stated that intraobserver variability was +/- 9.6 degrees and interobserver variability was +/- 11.8 degrees. METHODS: Sixty-nine curves in fifty patients with congenital scoliosis were measured on two separate occasions by seven different observers with varying experience in curve measurement. RESULTS: Mean intraobserver variance ranged from 1.9 degrees to 5.0 degrees, with an average of 2.8 degrees (95% confidence limit, +/- 3 degrees) for the seven observers. The interobserver variance was 3.35 degrees (95% confidence limit, 7.86 degrees). CONCLUSIONS: It is possible to measure curves in congenital scoliosis with much greater accuracy than previously reported. In the clinical situation in which a skilled observer can measure two radiographs at the same time, an accuracy of +/- 3 degrees can be expected 95% of the time.


Asunto(s)
Escoliosis/congénito , Escoliosis/diagnóstico por imagen , Columna Vertebral/diagnóstico por imagen , Historia Moderna 1601- , Humanos , Variaciones Dependientes del Observador , Radiografía , Reproducibilidad de los Resultados
6.
Spine (Phila Pa 1976) ; 26(2): 166-73, 2001 Jan 15.
Artículo en Inglés | MEDLINE | ID: mdl-11154537

RESUMEN

STUDY DESIGN: Retrospective study of patients after extension of previous scoliosis fusions to the pelvis. OBJECTIVE: To determine whether modern instrumentation and surgical techniques provide for increased fusion rates with fewer complications. SUMMARY OF BACKGROUND DATA: Traditionally, long fusions to the pelvis in adults with idiopathic scoliosis have resulted in high complication rates, including pseudarthrosis. METHODS: The hospital and clinic charts of 41 patients (40 female, 1 male) were reviewed 41 months (range: 24-116) after surgery for extension to the pelvis of previous scoliosis fusions. Thirty-nine of 41 had a combined anteroposterior fusion extension; two had posterior extension only. In 37 of 41 patients, Cotrel-Dubousset (CD) instrumentation was used; in two, Isola (Acromed Corp., Cleveland, OH), in one, TSRH; (Sofamor-Danek, Memphis, TN), and in one, Synergy (Cross Medical Products, Columbus, OH). Parameters analyzed were fusion rate, sagittal and coronal balance, lumbar lordosis, length of fusion extension, and distal fixation method. RESULTS: Complications were seen in 30 of 41 patients. The pseudarthrosis rate was 37% (15/41) and was significantly related to the method of distal posterior fixation. With sacral fixation only, the rate was 53% (8/15), with iliac fixation only 42% (3/7), and with both iliac and sacral fixation 21% (4/19; P < 0.05). This was not correlated with fusion rate, and the length of fusion extension did not affect the pseudarthrosis rate or sagittal balance. CONCLUSION: When fixed to the ilium and sacrum, modern instrumentation appears capable of maintaining sagittal balance with lower rates of pseudarthrosis when previous scoliosis fusions are extended to the pelvis. The complication rate remains significant.


Asunto(s)
Pelvis/cirugía , Complicaciones Posoperatorias/etiología , Complicaciones Posoperatorias/prevención & control , Reoperación/métodos , Escoliosis/cirugía , Fusión Vertebral/métodos , Adulto , Anciano , Femenino , Humanos , Fijadores Internos/efectos adversos , Lordosis/diagnóstico por imagen , Lordosis/etiología , Lordosis/cirugía , Dolor de la Región Lumbar/diagnóstico por imagen , Dolor de la Región Lumbar/etiología , Dolor de la Región Lumbar/cirugía , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/diagnóstico por imagen , Equilibrio Postural/fisiología , Seudoartrosis/diagnóstico por imagen , Seudoartrosis/epidemiología , Seudoartrosis/etiología , Radiografía , Reoperación/efectos adversos , Reoperación/normas , Estudios Retrospectivos , Escoliosis/diagnóstico por imagen , Escoliosis/patología , Fusión Vertebral/efectos adversos , Fusión Vertebral/clasificación , Resultado del Tratamiento
8.
J Pediatr Orthop ; 20(6): 796-8, 2000.
Artículo en Inglés | MEDLINE | ID: mdl-11097257

RESUMEN

The purpose of this prospective study was to determine the range of "normalcy" in the radiologic measurement of thoracic kyphosis in children by using a standardized position and full-length radiograph in 121 normal children. Using +/- two standard deviations from the mean as the definition of "normal," a range of 20 degrees - 50 degrees was determined. There was no difference between the various age subgroups or between genders.


Asunto(s)
Cifosis/diagnóstico por imagen , Adolescente , Adulto , Niño , Preescolar , Diagnóstico Diferencial , Femenino , Humanos , Masculino , Estudios Prospectivos , Radiografía
9.
Clin Orthop Relat Res ; (378): 9-14, 2000 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-10986968

RESUMEN

Innovations in spine surgery date back to the late nineteenth century when sterile surgery and anesthesia made progress possible. Were these advancements always done within the frame-work of ethical behavior, or were patients placed at inappropriate risks just for the sake of change? How does a surgeon choose to do a new procedure? What inner questions must be asked before proceeding? How much training is necessary, and from whom? How do we know when a new innovation is valid? In reality, these and other questions have faced us in the past. A review of historical process gives answers as to how we should behave in the future.


Asunto(s)
Artrodesis/historia , Ortopedia/historia , Escoliosis/historia , Historia del Siglo XX , Humanos , Escoliosis/cirugía
10.
J Spinal Disord ; 13(1): 42-5, 2000 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-10710149

RESUMEN

The authors reviewed 817 instrumented lumbosacral fusions in adults and found an incidence of 3.2% deep wound infections. The primary focus of this study was the management of these infections, with particular attention to whether the implants needed to be removed. A consulting infectious disease specialist indicated that an acute infection of a low back fusion wound could not be healed without removal of the metallic implants. This opinion was in contrast to the authors' daily experience and prompted this study. The authors identified and reviewed 817 cases of instrumented posterior lumbosacral arthrodeses in adults. A detailed analysis of any case with a deep wound infection was performed and yielded and infection rate of 3.2% (26 patients). Of these, 24 achieved a clean, closed wound without removal of instrumentation through a protocol of aggressive debridement and secondary closure. Instrumentation removal is not necessary to obtain a clean, closed wound using an aggressive approach with early diagnosis, vigorous debridement in the operative room under general anesthesia, delayed primary or secondary closure, and appropriate antibiotic coverage.


Asunto(s)
Infecciones Relacionadas con Prótesis/epidemiología , Infecciones Relacionadas con Prótesis/terapia , Enfermedades de la Columna Vertebral/cirugía , Fusión Vertebral/instrumentación , Enfermedad Aguda , Adulto , Anciano , Anciano de 80 o más Años , Placas Óseas , Tornillos Óseos , Infecciones por Escherichia coli/epidemiología , Infecciones por Escherichia coli/terapia , Femenino , Humanos , Incidencia , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Infecciones Estafilocócicas/epidemiología , Infecciones Estafilocócicas/terapia
11.
Spine (Phila Pa 1976) ; 24(22): 2325-31, 1999 Nov 15.
Artículo en Inglés | MEDLINE | ID: mdl-10586456

RESUMEN

STUDY DESIGN: Retrospective chart and radiographic film review. OBJECTIVES: To discern the deformity problems in diastrophic dysplasia and to report our results in surgical treatment. SUMMARY OF BACKGROUND DATA: Due to the rarity of the problem, the literature is very scanty as to the indications for surgery or the best technique. METHODS: Analysis of radiographic film for scoliosis, kyphosis, lordosis, and decompensation before surgery, after surgery, and at follow-up. Analysis of charts for complications and problems. RESULTS: The most common deformity pattern was a double thoracic kyphosis (79 degrees/97 degrees) with a true kyphosis at the junction of the two scolioses (101 degrees). Combined anterior-posterior arthrodesis gave the best results. CONCLUSIONS: Very severe deformity can occur in children with diastrophic dysplasia, even at a young age. Prompt anterior-posterior arthrodesis can prevent catastrophic deformity.


Asunto(s)
Enfermedades del Desarrollo Óseo/cirugía , Fusión Vertebral , Adolescente , Adulto , Enfermedades del Desarrollo Óseo/diagnóstico por imagen , Niño , Femenino , Estudios de Seguimiento , Humanos , Cifosis/diagnóstico por imagen , Cifosis/cirugía , Vértebras Lumbares/anomalías , Vértebras Lumbares/cirugía , Radiografía , Escoliosis/diagnóstico por imagen , Escoliosis/cirugía , Vértebras Torácicas/anomalías , Vértebras Torácicas/cirugía , Factores de Tiempo , Resultado del Tratamiento
12.
J Bone Joint Surg Am ; 81(11): 1519-28, 1999 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-10565643

RESUMEN

BACKGROUND: The safety and the effectiveness of pedicle-screw instrumentation in the spine have been questioned despite its use worldwide to enhance stabilization of the spine. This review was performed to answer questions about the technique of insertion and the nature and etiology of complications directly attributable to the screws. METHODS: We performed a retrospective review of all of the pedicle-screw procedures that were done by us from January 1, 1984, to December 31, 1993. We inserted 4790 screws during 915 operative procedures on 875 patients; 668 (76.3 percent) of the patients had a lumbosacral arthrodesis. The mean duration of follow-up was three years (range, two to five years). The accuracy of screw placement was assessed on intraoperative, immediate postoperative, and follow-up radiographs with use of a technique that was developed by one of us (F. D.); this technique has yet to be validated to determine the prevalence of various types of error. RESULTS: Of the 4790 screws, 4548 (94.9 percent) had been inserted within the pedicle and the vertebral body. One hundred and thirty-four (2.8 percent) of the screws had perforated the anterior cortex, and this was the most common type of perforation. One hundred and fifteen (2.4 percent) of the screws were associated with complications that could be ascribed to the use of pedicle screws. The most common problem was late-onset discomfort or pain related to a pseudarthrosis or perhaps to the screws; this problem was associated with 1102 (23.0 percent) of the screws, used in 222 (24.3 percent) of the procedures. The symptoms necessitated removal of the instrumentation with or without repair of the pseudarthrosis. A pseudarthrosis was found during forty-six (20.7 percent) of the 222 procedures. Irritation of a nerve root occurred after nine procedures (1.0 percent) and was caused by eleven screws (0.2 percent); it was more commonly caused by medially placed screws. Three patients had residual neurological weakness despite removal of the screws. Twenty-five screws (0.5 percent), used in twenty procedures (2.2 percent), broke. The screws that broke were of an early design. A pseudarthrosis was found in thirteen of twenty patients who had broken screws. Sixteen of the twenty patients had an exploration; three of them were found to have a solid fusion, and thirteen were found to have a pseudarthrosis. The remaining four patients had evidence of a solid fusion on radiographs and had no pain. CONCLUSIONS: There are few problems associated with the insertion of screws, provided that the surgeon is experienced and adheres to the principles and details of the operative technique. Our review revealed a low rate of postoperative complications related to pedicle screws. The problem of late-onset pain may be related to the implants or to the stiffness of the construct; however, it is difficult to accurately identify its exact etiology.


Asunto(s)
Tornillos Óseos/efectos adversos , Fusión Vertebral/instrumentación , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Niño , Preescolar , Remoción de Dispositivos , Diseño de Equipo , Falla de Equipo , Femenino , Estudios de Seguimiento , Humanos , Cuidados Intraoperatorios , Complicaciones Intraoperatorias , Vértebras Lumbares/diagnóstico por imagen , Vértebras Lumbares/cirugía , Masculino , Persona de Mediana Edad , Dolor Postoperatorio/etiología , Enfermedades del Sistema Nervioso Periférico/etiología , Cuidados Posoperatorios , Seudoartrosis/etiología , Radiografía Intervencional , Estudios Retrospectivos , Sacro/diagnóstico por imagen , Sacro/cirugía , Seguridad , Fusión Vertebral/efectos adversos , Raíces Nerviosas Espinales/lesiones
15.
J Bone Joint Surg Am ; 81(5): 741-2, 1999 May.
Artículo en Inglés | MEDLINE | ID: mdl-10360704
16.
J Spinal Disord ; 12(3): 262-5, 1999 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-10382782

RESUMEN

The optimal surgical treatment of the King-Moe type II thoracic curve pattern is controversial. The issue of postoperative "decompensation" has arisen in conjunction with the use of third-generation instrumentation systems. This report presents the 44-year clinical and radiographic follow-up of a patient with a type II scoliosis treated with uninstrumented selective thoracic fusion using the criteria of King and Moe. The caudal extent of the fusion was defined by proper identification of the neutral and stable vertebra. At final follow-up, the patient remained well balanced and essentially pain free. Her level of function was "above average" for her age, as per SF-36 evaluation.


Asunto(s)
Escoliosis/cirugía , Fusión Vertebral/métodos , Vértebras Torácicas/cirugía , Femenino , Estudios de Seguimiento , Humanos , Persona de Mediana Edad , Radiografía , Escoliosis/diagnóstico por imagen , Escoliosis/terapia , Vértebras Torácicas/diagnóstico por imagen , Factores de Tiempo
17.
Spine (Phila Pa 1976) ; 24(9): 908-11, 1999 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-10327514

RESUMEN

STUDY DESIGN: A case report of scoliosis secondary to cerebrocosto-mandibular syndrome. OBJECTIVES: To bring about awareness of the scoliosis and respiratory problems associated with this rare syndrome. SUMMARY OF BACKGROUND DATA: Of the approximately 50 cases of this syndrome previously reported, only 3 involved scoliosis, and only 1 of these required surgery (but the patient expired). METHODS: A retrospective chart was made, and a radiologic review were done. RESULTS: A successful surgical outcome was achieved, despite severe preoperative curvature (112 degrees scoliosis) and diminished pulmonary function (21% vital capacity). CONCLUSION: This syndrome can be associated with progressive scoliosis but can be managed successfully with surgery.


Asunto(s)
Anomalías Craneofaciales/complicaciones , Mandíbula/anomalías , Costillas/anomalías , Escoliosis/etiología , Fusión Vertebral/métodos , Niño , Femenino , Estudios de Seguimiento , Humanos , Discapacidad Intelectual/complicaciones , Vértebras Lumbares/diagnóstico por imagen , Vértebras Lumbares/cirugía , Radiografía , Escoliosis/diagnóstico por imagen , Escoliosis/cirugía , Síndrome , Vértebras Torácicas/diagnóstico por imagen , Vértebras Torácicas/cirugía
18.
Spine (Phila Pa 1976) ; 24(2): 194-7, 1999 Jan 15.
Artículo en Inglés | MEDLINE | ID: mdl-9926393

RESUMEN

STUDY DESIGN: A case report. OBJECTIVES: To document the long-term effects of early fusion for progressive congenital scoliosis. SUMMARY OF BACKGROUND DATA: There is concern about fusion at an early age causing torso shortening and possible crankshaft phenomenon. METHODS: A review of medical and radiologic records. RESULTS: A 3-year old girl with progressive congenital scoliosis had posterior spinal arthrodesis in 1955. A pseudarthrosis was repaired at age 4, and at age 8 she had an osteotomy of the fusion mass because of bending of the fusion mass. In a follow-up 41 years after fusion, she has no back pain and no history of pulmonary problems. Despite the long fusion at a young age, her torso-to-leg ratio was remarkably good. The thoracic lordosis had improved to a normal thoracic kyphosis. CONCLUSION: Early arthrodesis was life saving and caused no long-term problems. Because significant spinal growth has occurred by age 3, no adverse effects on torso-leg ratio with an early long arthrodesis, and in addition the crankshaft phenomenon is rare in congenital scoliosis.


Asunto(s)
Vértebras Lumbares/cirugía , Escoliosis/congénito , Escoliosis/cirugía , Fusión Vertebral , Vértebras Torácicas/cirugía , Preescolar , Femenino , Estudios de Seguimiento , Humanos , Vértebras Lumbares/diagnóstico por imagen , Pulmón/anomalías , Persona de Mediana Edad , Osteotomía , Seudoartrosis/diagnóstico por imagen , Seudoartrosis/cirugía , Radiografía , Escoliosis/diagnóstico por imagen , Vértebras Torácicas/diagnóstico por imagen
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...