Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Anaesthesist ; 57(1): 37-42, 2008 Jan.
Artículo en Alemán | MEDLINE | ID: mdl-18026708

RESUMEN

BACKGROUND: This study addresses the issue of analyzing the relationship between pre-mortem diagnoses and post-mortem findings in an intensive care unit (ICU). MATERIALS AND METHODS: Investigating a total of 1,205 autopsy cases, pre-mortem and post-mortem diagnoses were retrospectively evaluated and compared statistically by means of established categories (i.e."complete, partial, or lacking concordance" and"clinically suspected diagnosis"). RESULTS: When comparing clinical diagnoses and autopsy findings in terms of bronchopneumonia, concordance was recorded in only 21.15% of the cases investigated. CONCLUSION: In multimorbid ICU patients, bronchopneumonia frequently fails to be clinically recognized since clinical parameters commonly used for monitoring appear to be modified due to therapeutical interventions, and thus are inappropriate to reflect the complete histomorphological equivalent of the disease. This study also emphasizes the importance of autopsy which represents a sensitive means for professional medical quality assurance, and again establishes the necessity for strengthening the request for autopsy, which is currently characterized by an unfavourable decline.


Asunto(s)
Autopsia/estadística & datos numéricos , Bronconeumonía/diagnóstico , Bronconeumonía/mortalidad , Causas de Muerte , Cuidados Críticos , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Bronconeumonía/patología , Documentación , Femenino , Humanos , Pulmón/patología , Masculino , Persona de Mediana Edad , Garantía de la Calidad de Atención de Salud
2.
Br J Anaesth ; 95(5): 603-10, 2005 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-16155037

RESUMEN

BACKGROUND: Impedance cardiography (ICG) has been used extensively to estimate stroke volume (SV) and cardiac output (CO) from changes of thoracic electrical bioimpedance (TEB). However, studies comparing ICG with reference methods have questioned the reliability of this approach. Electrical velocimetry (EV) provides a new algorithm to calculate CO from variations in TEB. As the transoesophageal Doppler echocardiographic quantification of CO (TOE-CO) has emerged as a reliable method, the purpose of this study was to determine the limits of agreement between CO estimations using EV (EV-CO) and TOE-CO. METHODS: Standard ECG electrodes were used for non-invasive EV-CO measurements. These were placed on 37 patients scheduled for coronary artery surgery necessitating transoesophageal echocardiography monitoring. Simultaneous EV-CO and TOE-CO measurements were recorded after induction of anaesthesia. EV-CO was calculated using the Bernstein-Osypka equation. TOE-CO was measured across the aortic valve using continuous-wave Doppler echocardiography and a triangular orifice model. RESULTS: A significant high correlation was found between the TOE-CO and the EV-CO measurements (r2=0.86). Data were related linearly. The slope of the line (1.10 (se 0.07)) was not significantly different from unity, and the point at which it intersected the ordinate (-0.46 (0.32) litre min(-1)) was not significantly different from zero. Bland-Altman analysis revealed a bias of 0.18 litre min(-1) with narrow limits of agreement (-0.99 to 1.36 litre min(-1)). CONCLUSIONS: The agreement between EV-CO and TOE-CO is clinically acceptable, and these two techniques can be used interchangeably.


Asunto(s)
Gasto Cardíaco , Puente de Arteria Coronaria , Monitoreo Intraoperatorio/métodos , Volumen Sistólico , Adulto , Anciano , Anciano de 80 o más Años , Algoritmos , Válvula Aórtica/diagnóstico por imagen , Ecocardiografía Transesofágica , Femenino , Hemodinámica , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Reología
3.
Acta Anaesthesiol Scand ; 49(8): 1135-41, 2005 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-16095455

RESUMEN

BACKGROUND: Substantial research using echocardiography has established that stroke volume (SV) or cardiac output (CO) can be measured non-invasively at the level of the aortic valve (AV) with high accuracy. Stroke volume is the product of the velocity time integral occurring at the sampling site and the effective systolic AV orifice area (AVOAeff). Nevertheless, a generally accepted method for the determination of AVOAeff is still lacking. METHODS: Aortic valve OAeff was measured in 228 consecutive patients scheduled for coronary artery surgery. Two widely adopted methods were applied to approximate the constantly changing orifice area of the AV: (1) the circular orifice model (AVOA-CM), and (2) the triangular orifice model (AVOA-TM). Aortic valve OA-CM assumes the shape of a circle as an appropriately time averaged geometrical model, and AVOA-TM takes the shape of an equilateral triangle for granted. RESULTS: The AV was easily imaged by echocardiography in both short- and long-axis views in all patients. Relying on AVOA-CM, AVOAeff was 3.49+/-0.77 cm2. AVOA-TM estimates were 2.80+/-0.55 cm2 (mean+/-SD). The results did not agree (bias analysis). CONCLUSIONS: The echocardiographic measurement of SV or CO at the level of the AV has to be reconsidered.


Asunto(s)
Válvula Aórtica/diagnóstico por imagen , Gasto Cardíaco/fisiología , Ecocardiografía Doppler/métodos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Volumen Sistólico/fisiología , Sístole/fisiología
4.
Z Kardiol ; 91(12): 1013-23, 2002 Dec.
Artículo en Alemán | MEDLINE | ID: mdl-12490991

RESUMEN

Up to 30% of patients with an organ transplantation develop precancerous lesions and malignant tumors, especially of the skin. All 241 patients who underwent heart transplantation from 1990 to 2000 were evaluated with regard to the development of neoplasias. Those alive in September 1999 were referred for a standardized dermatological exam (n=156) which detected malignancy in 28 patients being transplanted for 4.98 years on average. The skin was the organ most frequently involved (64%, n=18). 18% (n=5) of tumors were found in the urinary and genital tract, 7% (n=2) each in the respiratory and gastrointestinal tract, and 4% (n=1 ) in the breasts. The average age of patients who developed tumors was significantly higher as compared to the overall mean age (59.5+/-5 vs 49.8+/-14.7 years, p=0.00027). There was no correlation between development of malignancy and HLA matching, immunosuppressive drugs used, dosage and serum levels of immunosuppressive medication, and episodes of transplant rejection. Our study shows that the risk to develop tumors is at least doubled after heart transplantation. Due to the high incidence of skin tumors, transplant patients should undergo dermatological examinations on a regular basis.


Asunto(s)
Trasplante de Corazón , Neoplasias/epidemiología , Complicaciones Posoperatorias/epidemiología , Factores de Edad , Anciano , Interpretación Estadística de Datos , Femenino , Neoplasias de los Genitales Femeninos/epidemiología , Humanos , Terapia de Inmunosupresión , Incidencia , Neoplasias Pulmonares/epidemiología , Masculino , Persona de Mediana Edad , Neoplasias/terapia , Factores de Riesgo , Neoplasias Cutáneas/diagnóstico , Neoplasias Cutáneas/epidemiología , Resultado del Tratamiento , Neoplasias Urogenitales/epidemiología
SELECCIÓN DE REFERENCIAS