Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Mol Imaging Biol ; 26(1): 36-44, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37848641

RESUMEN

PURPOSE: Morphological imaging using MRI is essential for brain tumour diagnostics. Dynamic susceptibility contrast (DSC) perfusion-weighted MRI (PWI), as well as amino acid PET, may provide additional information in ambiguous cases. Since PWI is often unavailable in patients referred for amino acid PET, we explored whether maps of relative cerebral blood volume (rCBV) in brain tumours can be extracted from the early phase of PET using O-(2-18F-fluoroethyl)-L-tyrosine (18F-FET). PROCEDURE: Using a hybrid brain PET/MRI scanner, PWI and dynamic 18F-FET PET were performed in 33 patients with cerebral glioma and four patients with highly vascularized meningioma. The time interval from 0 to 2 min p.i. was selected to best reflect the blood pool phase in 18F-FET PET. For each patient, maps of MR-rCBV, early 18F-FET PET (0-2 min p.i.) and late 18F-FET PET (20-40 min p.i.) were generated and coregistered. Volumes of interest were placed on the tumour (VOI-TU) and normal-appearing brain (VOI-REF). The correlation between tumour-to-brain ratios (TBR) of the different parameters was analysed. In addition, three independent observers evaluated MR-rCBV and early 18F-FET maps (18F-FET-rCBV) for concordance in signal intensity, tumour extent and intratumoural distribution. RESULTS: TBRs calculated from MR-rCBV and 18F-FET-rCBV showed a significant correlation (r = 0.89, p < 0.001), while there was no correlation between late 18F-FET PET and MR-rCBV (r = 0.24, p = 0.16) and 18F-FET-rCBV (r = 0.27, p = 0.11). Visual rating yielded widely agreeing findings or only minor differences between MR-rCBV maps and 18F-FET-rCBV maps in 93 % of the tumours (range of three independent raters 91-94%, kappa among raters 0.78-1.0). CONCLUSION: Early 18F-FET maps (0-2 min p.i.) in gliomas provide similar information to MR-rCBV maps and may be helpful when PWI is not possible or available. Further studies in gliomas are needed to evaluate whether 18F-FET-rCBV provides the same clinical information as MR-rCBV.


Asunto(s)
Neoplasias Encefálicas , Glioma , Neoplasias Meníngeas , Humanos , Neoplasias Encefálicas/patología , Glioma/patología , Imagen por Resonancia Magnética/métodos , Tomografía de Emisión de Positrones/métodos , Tirosina , Perfusión
2.
World Neurosurg ; 113: e727-e737, 2018 May.
Artículo en Inglés | MEDLINE | ID: mdl-29510293

RESUMEN

OBJECTIVE: To compare the diagnostic performance of O-(2-18F-fluoroethyl)-L-tyrosine (18F-FET) positron emission tomography (PET) and perfusion-weighted magnetic resonance imaging (PWI) for the diagnosis of progressive or recurrent glioma. METHODS: Thirty-two pretreated gliomas (25 progressive or recurrent tumors, 7 treatment-related changes) were investigated with 18F-FET PET and PWI via a hybrid PET/magnetic resonance scanner. Volumes of interest with a diameter of 16 mm were centered on the maximum of abnormality in the tumor area in PET and PWI maps (relative cerebral blood volume, relative cerebral blood flow, mean transit time) and the contralateral unaffected hemisphere. Mean and maximum tumor-to-brain ratios as well as dynamic data for 18F-FET uptake were calculated. Diagnostic accuracies were evaluated by receiver operating characteristic analyses, calculating the area under the curve. RESULTS: 18F-FET PET showed a significant greater sensitivity to detect abnormalities in pretreated gliomas than PWI (76% vs. 52%, P = 0.03). The maximum tumor-to-brain ratio of 18F-FET PET was the only parameter that discriminated treatment-related changes from progressive or recurrent gliomas (area under the curve, 0.78; P = 0.03, best cut-off 2.61; sensitivity 80%, specificity 86%, accuracy 81%). Among patients with signal abnormality in both modalities, 75% revealed spatially incongruent local hot spots. CONCLUSIONS: This pilot study suggests that 18F-FET PET is superior to PWI to diagnose progressive or recurrent glioma.


Asunto(s)
Neoplasias Encefálicas/diagnóstico por imagen , Glioma/diagnóstico por imagen , Imagen por Resonancia Magnética/normas , Recurrencia Local de Neoplasia/diagnóstico por imagen , Tomografía de Emisión de Positrones/normas , Tirosina/análogos & derivados , Adulto , Anciano , Neoplasias Encefálicas/metabolismo , Estudios de Cohortes , Progresión de la Enfermedad , Femenino , Glioma/metabolismo , Humanos , Imagen por Resonancia Magnética/métodos , Masculino , Persona de Mediana Edad , Recurrencia Local de Neoplasia/metabolismo , Proyectos Piloto , Tomografía de Emisión de Positrones/métodos
3.
Eur J Nucl Med Mol Imaging ; 44(13): 2257-2265, 2017 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-28831534

RESUMEN

PURPOSE: Both perfusion-weighted MR imaging (PWI) and O-(2-18F-fluoroethyl)-L-tyrosine PET (18F-FET) provide grading information in cerebral gliomas. The aim of this study was to compare the diagnostic value of 18F-FET PET and PWI for tumor grading in a series of patients with newly diagnosed, untreated gliomas using an integrated PET/MR scanner. METHODS: Seventy-two patients with untreated gliomas [22 low-grade gliomas (LGG), and 50 high-grade gliomas (HGG)] were investigated with 18F-FET PET and PWI using a hybrid PET/MR scanner. After visual inspection of PET and PWI maps (rCBV, rCBF, MTT), volumes of interest (VOIs) with a diameter of 16 mm were centered upon the maximum of abnormality in the tumor area in each modality and the contralateral unaffected hemisphere. Mean and maximum tumor-to-brain ratios (TBRmean, TBRmax) were calculated. In addition, Time-to-Peak (TTP) and slopes of time-activity curves were calculated for 18F-FET PET. Diagnostic accuracies of 18F-FET PET and PWI for differentiating low-grade glioma (LGG) from high-grade glioma (HGG) were evaluated by receiver operating characteristic analyses (area under the curve; AUC). RESULTS: The diagnostic accuracy of 18F-FET PET and PWI to discriminate LGG from HGG was similar with highest AUC values for TBRmean and TBRmax of 18F-FET PET uptake (0.80, 0.83) and for TBRmean and TBRmax of rCBV (0.80, 0.81). In case of increased signal in the tumor area with both methods (n = 32), local hot-spots were incongruent in 25 patients (78%) with a mean distance of 10.6 ± 9.5 mm. Dynamic FET PET and combination of different parameters did not further improve diagnostic accuracy. CONCLUSIONS: Both 18F-FET PET and PWI discriminate LGG from HGG with similar diagnostic performance. Regional abnormalities in the tumor area are usually not congruent indicating that tumor grading by 18F-FET PET and PWI is based on different pathophysiological phenomena.


Asunto(s)
Glioma/diagnóstico por imagen , Glioma/patología , Imagen por Resonancia Magnética , Imagen Multimodal , Imagen de Perfusión , Tomografía de Emisión de Positrones , Tirosina/análogos & derivados , Adulto , Femenino , Humanos , Masculino , Persona de Mediana Edad , Clasificación del Tumor
4.
J Nucl Med ; 55(4): 540-5, 2014 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-24578243

RESUMEN

UNLABELLED: PET using O-(2-(18)F-fluoroethyl)-L-tyrosine ((18)F-FET) provides important diagnostic information in addition to that from conventional MR imaging on tumor extent and activity of cerebral gliomas. Recent studies suggest that perfusion-weighted MR imaging (PWI), especially maps of regional cerebral blood volume (rCBV), may provide similar diagnostic information. In this study, we directly compared (18)F-FET PET and PWI in patients with brain tumors. METHODS: Fifty-six patients with gliomas were investigated using static (18)F-FET PET and PWI. For comparison, 8 patients with meningiomas were included. We generated a set of tumor and reference volumes of interest (VOIs) based on morphologic MR imaging and transferred these VOIs to the corresponding (18)F-FET PET scans and PWI maps. From these VOIs, tumor-to-brain ratios (TBR) were calculated, and normalized histograms were generated for (18)F-FET PET and rCBV maps. Furthermore, in rCBV maps and in (18)F-FET PET scans, tumor volumes, their spatial congruence, and the distance between the local hot spots were assessed. RESULTS: For patients with glioma, TBR was significantly higher in (18)F-FET PET than in rCBV maps (TBR, 2.28 ± 0.99 vs. 1.62 ± 1.13; P < 0.001). Histogram analysis of the VOIs revealed that (18)F-FET scans could clearly separate tumor from background. In contrast, deriving this information from rCBV maps was difficult. Tumor volumes were significantly larger in (18)F-FET PET than in rCBV maps (tumor volume, 24.3 ± 26.5 cm(3) vs. 8.9 ± 13.9 cm(3); P < 0.001). Accordingly, spatial overlap of both imaging parameters was poor (congruence, 11.0%), and mean distance between the local hot spots was 25.4 ± 16.1 mm. In meningioma patients, TBR was higher in rCBV maps than in (18)F-FET PET (TBR, 5.33 ± 2.63 vs. 2.37 ± 0.32; P < 0.001) whereas tumor volumes were comparable. CONCLUSION: In patients with cerebral glioma, tumor imaging with (18)F-FET PET and rCBV yields different information. (18)F-FET PET shows considerably higher TBRs and larger tumor volumes than rCBV maps. The spatial congruence of both parameters is poor. The locations of the local hot spots differ considerably. Taken together, our data show that metabolically active tumor tissue of gliomas as depicted by amino acid PET is not reflected by rCBV as measured with PWI.


Asunto(s)
Neoplasias Encefálicas/diagnóstico por imagen , Neoplasias Encefálicas/patología , Glioma/diagnóstico por imagen , Glioma/patología , Imagen por Resonancia Magnética/métodos , Imagen de Perfusión/métodos , Tomografía de Emisión de Positrones/métodos , Adulto , Anciano , Interpretación Estadística de Datos , Femenino , Fluorodesoxiglucosa F18/líquido cefalorraquídeo , Humanos , Procesamiento de Imagen Asistido por Computador , Masculino , Meningioma/diagnóstico por imagen , Meningioma/patología , Persona de Mediana Edad , Radiofármacos/líquido cefalorraquídeo , Adulto Joven
5.
Stroke ; 35(3): 705-9, 2004 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-14752128

RESUMEN

BACKGROUND AND PURPOSE: In acute ischemic stroke, thrombolytic treatment with recombinant tissue plasminogen activator (rtPA) is limited by a concomitant activation of the coagulatory system, leading to incomplete or delayed reperfusion, microcirculatory disturbances, or even repeated vessel occlusions. Our pilot study sought to assess the therapeutic potential of a new treatment strategy combining rtPA at reduced dosages with a platelet glycoprotein IIb/IIIa (GPIIb/IIIa) inhibitory agent in acute middle cerebral artery occlusion. METHODS: Nineteen patients suffering from acute middle cerebral artery occlusion (Thrombolysis in Myocardial Infarction [TIMI] flow grade 0 to 1) underwent combined intravenous thrombolytic treatment using rtPA at reduced dosages and the GPIIb/IIIa antagonist tirofiban. Stroke MRI (diffusion- and perfusion-weighted imaging) and MR angiography were performed at baseline and between days 1 and 2 after treatment. Clinical scores (National Institutes of Health Stroke Scale and modified Rankin Scale) were assessed at baseline and after 1 week. RESULTS: Middle cerebral artery recanalization (TIMI flow grade 2 and 3) occurred in 13 of 19 patients (68%). The ischemic lesion on follow-up MRI was significantly smaller in patients with recanalization compared with those without recanalization (P=0.001). Only patients with recanalization improved neurologically (P<0.001). Because no symptomatic hemorrhage was observed, the power of our study to detect a symptomatic bleeding rate of > or =8% was at least 80%. CONCLUSIONS: Combined thrombolysis with a GPIIb/IIIa antagonist and rtPA at reduced dosages is promising but cannot be recommended for general use before prospective randomized clinical trials are completed.


Asunto(s)
Infarto de la Arteria Cerebral Media/tratamiento farmacológico , Proteínas Recombinantes/uso terapéutico , Terapia Trombolítica , Activador de Tejido Plasminógeno/uso terapéutico , Tirosina/análogos & derivados , Tirosina/uso terapéutico , Enfermedad Aguda , Adulto , Anciano , Anciano de 80 o más Años , Imagen de Difusión por Resonancia Magnética , Relación Dosis-Respuesta a Droga , Quimioterapia Combinada , Femenino , Fibrinolíticos/uso terapéutico , Humanos , Infarto de la Arteria Cerebral Media/diagnóstico , Angiografía por Resonancia Magnética , Masculino , Persona de Mediana Edad , Complejo GPIIb-IIIa de Glicoproteína Plaquetaria/antagonistas & inhibidores , Tirofibán , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...