Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Vet Ophthalmol ; 22(5): 683-694, 2019 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-30715790

RESUMEN

OBJECTIVE: To describe and compare normative anterior segment parameters between canine age groups using the Pentacam® HR Scheimpflug camera (Pentacam). ANIMALS STUDIED: Thirty-six sedated dogs (60 eyes) of varying ages and breeds were imaged with the Pentacam; only nondiseased anterior segments were included. PROCEDURES: Dogs were divided into three age groups: Group 1 (1-5 years), Group 2 (6-10 years), and Group 3 (11-15 years). Values assessed included central corneal thickness (CCT), anterior and posterior corneal elevation (ACE/PCE), anterior and posterior corneal curvature metrics, corneal volume (CV), anterior and posterior corneal astigmatism (AA/PA), anterior chamber depth (ACD), anterior chamber volume (ACV), and anterior chamber angle (ACA). Tukey-adjusted pairwise comparisons were performed. RESULTS: Overall CCT (mean ± SD) was 631.07 ± 59.91 µm. Central corneal thickness was 608.60 ± 48.63 µm for Group 1, 648.57 ± 51.06 µm for Group 2, and 635.37 ± 73.71 µm for Group 3. Anterior corneal elevation (ACE) measured 9.08 ± 0.58 mm, PCE measured 8.04 ± 0.50 mm, and CV was 58.13 ± 5.39 mm3 . Astigmatism values were 1.34 ± 0.94 D for AA and 0.46 ± 0.44 D for PA. Anterior chamber values were 3.76 ± 0.56 mm for ACD, 383.68 ± 66.24 mm3 for ACV, and 23.62 ± 29.33˚ for ACA. Significant differences were found between Groups 1 and 2 for CV (55.08 ± 4.08 mm3 and 60.32 ± 4.19 mm3 , respectively), (P = 0.02). CONCLUSIONS: Corneal volume significantly increased between Group 1 and Group 2. Central corneal thickness increased from Group 1 to Group 3, but was not significant with the current sample size. There were no other differences between age groups.


Asunto(s)
Cámara Anterior/diagnóstico por imagen , Perros/anatomía & histología , Animales , Cámara Anterior/anatomía & histología , Femenino , Masculino , Fotograbar/veterinaria , Lámpara de Hendidura/veterinaria
2.
Vet Ophthalmol ; 21(4): 362-370, 2018 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-29034562

RESUMEN

OBJECTIVE: To compare central corneal thickness (CCT) values in canine eyes using Pentacam-HR® Scheimpflug imaging (Pentacam), Optovue® iVue spectral-domain optical coherence tomography (SD-OCT), and high-resolution ultrasound biomicroscopy (UBM) and generate normative canine Pentacam CCT values. ANIMALS STUDIED: Twenty-four client-owned dogs (37 eyes) with nondiseased cornea(s) presenting to the Colorado State University Veterinary Teaching Hospital. PROCEDURES: Corneal images were acquired via Pentacam, SD-OCT, and UBM in the listed order. Machine-calculated values of CCT from Pentacam and SD-OCT were compared to operator-measured values from UBM. Bland-Altman analysis was performed to evaluate agreement between instruments. RESULTS: Mean CCT ± SD measured by Pentacam was 629.73 ± 64.57 µm, by SD-OCT was 610.56 ± 57.48 µm, and by UBM was 689.77 ± 55.93 µm. On average, Pentacam CCT was 19.17 ± 32.90 µm (3%) thicker than SD-OCT and 65.12 ± 44.52 µm (10.3%) thinner than UBM. SD-OCT was on average 82.47 µm (13.5% ) thinner than UBM. The 95% limits of agreement were (-45.31, 83.65), (-152.38, 22.13), and (-126.674, -38.270) for Pentacam vs. SD-OCT, Pentacam vs. UBM, and SD-OCT vs. UBM respectively. All differences were statistically significant (P < 0.01). CONCLUSIONS: Considering there is an average of 7.5% normal diurnal variation in canine CCT, a 3.0% difference between Pentacam and SD-OCT values is likely not clinically relevant. However, Pentacam measurements were both statistically and clinically significantly different from UBM and SD-OCT measurements.


Asunto(s)
Córnea/anatomía & histología , Paquimetría Corneal/veterinaria , Perros/anatomía & histología , Microscopía Acústica/veterinaria , Tomografía de Coherencia Óptica/veterinaria , Animales , Córnea/diagnóstico por imagen , Paquimetría Corneal/métodos , Femenino , Masculino , Microscopía Acústica/métodos , Valores de Referencia , Reproducibilidad de los Resultados , Tomografía de Coherencia Óptica/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...