Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Sci Rep ; 14(1): 13057, 2024 06 06.
Artículo en Inglés | MEDLINE | ID: mdl-38844650

RESUMEN

Combined action observation and motor imagery (AOMI) facilitates corticospinal excitability (CSE) and may potentially induce plastic-like changes in the brain in a similar manner to physical practice. This study used transcranial magnetic stimulation (TMS) to explore changes in CSE for AOMI of coordinative lower-limb actions. Twenty-four healthy adults completed two baseline (BLH, BLNH) and three AOMI conditions, where they observed a knee extension while simultaneously imagining the same action (AOMICONG), plantarflexion (AOMICOOR-FUNC), or dorsiflexion (AOMICOOR-MOVE). Motor evoked potential (MEP) amplitudes were recorded as a marker of CSE for all conditions from two knee extensor, one dorsi flexor, and two plantar flexor muscles following TMS to the right leg representation of the left primary motor cortex. A main effect for experimental condition was reported for all three muscle groups. MEP amplitudes were significantly greater in the AOMICONG condition compared to the BLNH condition (p = .04) for the knee extensors, AOMICOOR-FUNC condition compared to the BLH condition (p = .03) for the plantar flexors, and AOMICOOR-MOVE condition compared to the two baseline conditions for the dorsi flexors (ps ≤ .01). The study findings support the notion that changes in CSE are driven by the imagined actions during coordinative AOMI.


Asunto(s)
Potenciales Evocados Motores , Imaginación , Extremidad Inferior , Corteza Motora , Músculo Esquelético , Tractos Piramidales , Estimulación Magnética Transcraneal , Humanos , Masculino , Femenino , Potenciales Evocados Motores/fisiología , Adulto , Corteza Motora/fisiología , Imaginación/fisiología , Adulto Joven , Tractos Piramidales/fisiología , Extremidad Inferior/fisiología , Músculo Esquelético/fisiología , Electromiografía
2.
Europace ; 26(7)2024 Jul 02.
Artículo en Inglés | MEDLINE | ID: mdl-38890126

RESUMEN

AIMS: Cardiac implantable electronic device (CIED) infections are a burden to hospitals and costly for healthcare systems. Chronic kidney disease (CKD) increases the risk of CIED infections, but its differential impact on healthcare utilization, costs, and outcomes is not known. METHODS AND RESULTS: This retrospective analysis used de-identified Medicare Fee-for-Service claims to identify patients implanted with a CIED from July 2016 to December 2020. Outcomes were defined as hospital days and costs within 12 months post-implant, post-infection CKD progression, and mortality. Generalized linear models were used to calculate results by CKD and infection status while controlling for other comorbidities, with differences between cohorts representing the incremental effect associated with CKD. A total of 584 543 patients had a CIED implant, of which 26% had CKD and 1.4% had a device infection. The average total days in hospital for infected patients was 23.5 days with CKD vs. 14.5 days (P < 0.001) without. The average cost of infection was $121 756 with CKD vs. $55 366 without (P < 0.001), leading to an incremental cost associated with CKD of $66 390. Infected patients with CKD were more likely to have septicaemia or severe sepsis than those without CKD (11.0 vs. 4.6%, P < 0.001). After infection, CKD patients were more likely to experience CKD progression (hazard ratio 1.26, P < 0.001) and mortality (hazard ratio 1.89, P < 0.001). CONCLUSION: Cardiac implantable electronic device infection in patients with CKD was associated with more healthcare utilization, higher cost, greater disease progression, and greater mortality compared to patients without CKD.


Asunto(s)
Desfibriladores Implantables , Progresión de la Enfermedad , Marcapaso Artificial , Infecciones Relacionadas con Prótesis , Insuficiencia Renal Crónica , Humanos , Insuficiencia Renal Crónica/terapia , Insuficiencia Renal Crónica/economía , Insuficiencia Renal Crónica/mortalidad , Masculino , Femenino , Desfibriladores Implantables/economía , Desfibriladores Implantables/efectos adversos , Estudios Retrospectivos , Anciano , Estados Unidos/epidemiología , Infecciones Relacionadas con Prótesis/economía , Infecciones Relacionadas con Prótesis/mortalidad , Marcapaso Artificial/economía , Marcapaso Artificial/efectos adversos , Marcapaso Artificial/estadística & datos numéricos , Anciano de 80 o más Años , Costos de la Atención en Salud/estadística & datos numéricos , Medicare/economía , Aceptación de la Atención de Salud/estadística & datos numéricos , Tiempo de Internación/estadística & datos numéricos , Tiempo de Internación/economía
3.
N Engl J Med ; 2024 May 18.
Artículo en Inglés | MEDLINE | ID: mdl-38767244

RESUMEN

BACKGROUND: The subcutaneous implantable cardioverter-defibrillator (ICD) is associated with fewer lead-related complications than a transvenous ICD; however, the subcutaneous ICD cannot provide bradycardia and antitachycardia pacing. Whether a modular pacing-defibrillator system comprising a leadless pacemaker in wireless communication with a subcutaneous ICD to provide antitachycardia and bradycardia pacing is safe remains unknown. METHODS: We conducted a multinational, single-group study that enrolled patients at risk for sudden death from ventricular arrhythmias and followed them for 6 months after implantation of a modular pacemaker-defibrillator system. The safety end point was freedom from leadless pacemaker-related major complications, evaluated against a performance goal of 86%. The two primary performance end points were successful communication between the pacemaker and the ICD (performance goal, 88%) and a pacing threshold of up to 2.0 V at a 0.4-msec pulse width (performance goal, 80%). RESULTS: We enrolled 293 patients, 162 of whom were in the 6-month end-point cohort and 151 of whom completed the 6-month follow-up period. The mean age of the patients was 60 years, 16.7% were women, and the mean (±SD) left ventricular ejection fraction was 33.1±12.6%. The percentage of patients who were free from leadless pacemaker-related major complications was 97.5%, which exceeded the prespecified performance goal. Wireless-device communication was successful in 98.8% of communication tests, which exceeded the prespecified goal. Of 151 patients, 147 (97.4%) had pacing thresholds of 2.0 V or less, which exceeded the prespecified goal. The percentage of episodes of arrhythmia that were successfully terminated by antitachycardia pacing was 61.3%, and there were no episodes for which antitachycardia pacing was not delivered owing to communication failure. Of 162 patients, 8 died (4.9%); none of the deaths were deemed to be related to arrhythmias or the implantation procedure. CONCLUSIONS: The leadless pacemaker in wireless communication with a subcutaneous ICD exceeded performance goals for freedom from major complications related to the leadless pacemaker, for communication between the leadless pacemaker and subcutaneous ICD, and for the percentage of patients with a pacing threshold up to 2.0 V at a 0.4-msec pulse width at 6 months. (Funded by Boston Scientific; MODULAR ATP ClinicalTrials.gov NCT04798768.).

4.
PLoS One ; 19(5): e0301115, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38728334

RESUMEN

BACKGROUND: Developmental coordination disorder (DCD) affects movement coordination, but little is known about how the condition impacts the behaviours of car drivers and pedestrians. AIMS: This study examined the self-reported driving and pedestrian behaviours of adults with Developmental Coordination Disorder (DCD). METHODS AND PROCEDURES: One hundred and twenty-eight participants (62 adults with DCD vs. 66 TD adults) responded to an online survey asking them about their perceptions of confidence and self-reported driving and pedestrian behaviours in the real-world. OUTCOMES AND RESULTS: Results suggested that adults with DCD felt less confident and reported more lapses in attention (e.g., forgetting where their car was parked) and errors (e.g., failing to check their mirrors prior to a manoeuvre) when driving compared to typically developed (TD) adults. Adults with DCD also reported feeling less confident and reported less adherence to road traffic laws (e.g., not waiting for a green crossing signal before crossing the road) when walking as pedestrians. CONCLUSIONS AND IMPLICATIONS: These results offer some much-needed insight into the behaviours of those with DCD outside of the laboratory environment and underline the need for research investigating the driving and pedestrian behaviours of individuals with DCD in 'real-world' contexts.


Asunto(s)
Conducción de Automóvil , Trastornos de la Destreza Motora , Peatones , Autoinforme , Humanos , Adulto , Femenino , Masculino , Conducción de Automóvil/psicología , Peatones/psicología , Trastornos de la Destreza Motora/psicología , Trastornos de la Destreza Motora/fisiopatología , Adulto Joven , Persona de Mediana Edad , Caminata , Atención/fisiología , Adolescente , Encuestas y Cuestionarios
5.
J Sport Exerc Psychol ; 46(4): 191-204, 2024 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-38714304

RESUMEN

Combined use of action observation and motor imagery (AOMI) is an increasingly popular motor-simulation intervention, which involves observing movements on video while simultaneously imagining the feeling of movement execution. Measuring and reporting participant imagery-ability characteristics are essential in motor-simulation research, but no measure of AOMI ability currently exists. Accordingly, the AOMI Ability Questionnaire (AOMI-AQ) was developed to address this gap in the literature. In Study 1, two hundred eleven participants completed the AOMI-AQ and the kinesthetic imagery subscales of the Movement Imagery Questionnaire-3 and Vividness of Motor Imagery Questionnaire-2. Following exploratory factor analysis, an 8-item AOMI-AQ was found to correlate positively with existing motor-imagery measures. In Study 2, one hundred seventy-four participants completed the AOMI-AQ for a second time after a period of 7-10 days. Results indicate a good test-retest reliability for the AOMI-AQ. The new AOMI-AQ measure provides a valid and reliable tool for researchers and practitioners wishing to assess AOMI ability.


Asunto(s)
Imaginación , Movimiento , Humanos , Masculino , Femenino , Encuestas y Cuestionarios , Adulto , Reproducibilidad de los Resultados , Adulto Joven , Adolescente , Cinestesia , Psicometría , Persona de Mediana Edad
6.
Brain Commun ; 6(2): fcae084, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38515442

RESUMEN

This scientific commentary refers to 'Explicit and implicit motor simulations are impaired in individuals with aphantasia', by Dupont  et al. (https://doi.org/10.1093/braincomms/fcae072) in Brain Communications.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...