Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros













Base de datos
Intervalo de año de publicación
1.
World J Stem Cells ; 16(2): 191-206, 2024 Feb 26.
Artículo en Inglés | MEDLINE | ID: mdl-38455098

RESUMEN

BACKGROUND: Knee osteoarthritis (KOA) is a common orthopedic condition with an uncertain etiology, possibly involving genetics and biomechanics. Factors like changes in chondrocyte microenvironment, oxidative stress, inflammation, and immune responses affect KOA development. Early-stage treatment options primarily target symptom relief. Mesenchymal stem cells (MSCs) show promise for treatment, despite challenges. Recent research highlights microRNAs (miRNAs) within MSC-released extracellular vesicles that can potentially promote cartilage regeneration and hinder KOA progression. This suggests exosomes (Exos) as a promising avenue for future treatment. While these findings emphasize the need for effective KOA progression management, further safety and efficacy validation for Exos is essential. AIM: To explore miR-29a's role in KOA, we'll create miR-29a-loaded vesicles, testing for early treatment in rat models. METHODS: Extraction of bone marrow MSC-derived extracellular vesicles, preparation of engineered vesicles loaded with miR-29a using ultrasonication, and identification using quantitative reverse transcription polymerase chain reaction; after establishing a rat model of KOA, rats were randomly divided into three groups: Blank control group injected with saline, normal extracellular vesicle group injected with normal extracellular vesicle suspension, and engineered extracellular vesicle group injected with engineered extracellular vesicle suspension. The three groups were subjected to general behavioral observation analysis, imaging evaluation, gross histological observation evaluation, histological detection, and immunohistochemical detection to compare and evaluate the progress of various forms of arthritis. RESULTS: General behavioral observation results showed that the extracellular vesicle group and engineered extracellular vesicle group had better performance in all four indicators of pain, gait, joint mobility, and swelling compared to the blank control group. Additionally, the engineered extracellular vesicle group had better pain relief at 4 wk and better knee joint mobility at 8 wk compared to the normal extracellular vesicle group. Imaging examination results showed that the blank control group had the fastest progression of arthritis, the normal extracellular vesicle group had a relatively slower progression, and the engineered extracellular vesicle group had the slowest progression. Gross histological observation results showed that the blank control group had the most obvious signs of arthritis, the normal extracellular vesicle group showed signs of arthritis, and the engineered extracellular vesicle group showed no significant signs of arthritis. Using the Pelletier gross score evaluation, the engineered extracellular vesicle group had the slowest progression of arthritis. Results from two types of staining showed that the articular cartilage of rats in the normal extracellular vesicle and engineered extracellular vesicle groups was significantly better than that of the blank control group, and the engineered extracellular vesicle group had the best cartilage cell and joint surface condition. Immunohistochemical detection of type II collagen and proteoglycan showed that the extracellular matrix of cartilage cells in the normal extracellular vesicle and engineered extracellular vesicle groups was better than that of the blank control group. Compared to the normal extracellular vesicle group, the engineered extracellular vesicle group had a better regulatory effect on the extracellular matrix of cartilage cells. CONCLUSION: Engineered Exos loaded with miR-29a can exert anti-inflammatory effects and maintain extracellular matrix stability, thereby protecting articular cartilage, and slowing the progression of KOA.

2.
Zhonghua Wai Ke Za Zhi ; 50(3): 215-8, 2012 Mar.
Artículo en Chino | MEDLINE | ID: mdl-22800742

RESUMEN

OBJECTIVE: To explore the feasibility of laparoscopic-assisted radical right hemicolectomy with the outcome being a complete mesocolic excision (CME). METHODS: Between February 2010 and June 2011, we performed the standardized surgery of laparoscopic-assisted radical right hemicolectomy with an aim of CME on 14 patients. There were 10 males and 4 females, with an average age of 57 years (range 36 to 74 years). All the pathologic results in 14 cases were primary colonic adenocarcinoma. The TNM stages were distributed as follows: 2 in II A, 3 in II B, 3 in III A, 5 in III B and 1 in III C. RESULTS: Surgery was successfully performed for all patients without open conversion. The average operation time was (178 ± 37) minutes (range 127 to 221 minutes), average intraoperative blood loss was (67 ± 23) ml (range 30 to 110 ml), while the average number of lymph node harvest was 21 ± 7 (range 14 to 31), and the postoperative hospital stay was (10.0 ± 2.2) days (range 7 to 15 days). Minor complications occured in 2 patients. Major complications and post-operative mortality were not observed. All the patients were followed up for 3 to 19 months, no tumor recurrence or metastasis was identified. CONCLUSION: The standardized surgery of laparoscopic-assisted radical right hemicolectomy with the final outcome of CME is safe and feasible.


Asunto(s)
Colectomía/métodos , Neoplasias del Colon/cirugía , Mesocolon/cirugía , Adulto , Anciano , Estudios de Factibilidad , Femenino , Estudios de Seguimiento , Humanos , Laparoscopía/métodos , Masculino , Persona de Mediana Edad
3.
Anal Chim Acta ; 588(2): 216-23, 2007 Apr 11.
Artículo en Inglés | MEDLINE | ID: mdl-17386813

RESUMEN

In this paper, chromatographic fingerprint was firstly used for quality control of tobacco flavors. Based on gas chromatography-mass spectrometry (GC-MS) and combined chemometrics methods, a simple, reliable and reproducible method for developing chromatographic fingerprint of coffee flavor, one of tobacco flavors, was described. Six coffee flavor samples obtained from different locations were used to establish the fingerprint. The qualitative and quantitative analysis of coffee flavor sample from Shenzhen was completed with the help of subwindow factor analysis (SFA). Fifty-two components of 68 separated constituents in coffee flavor sample from Shenzhen, accounting for 88.42% of the total content, were identified and quantified. Then, spectral correlative chromatography (SCC) was used to extract the common peaks from other five studied coffee flavor samples. Thirty-eight components were found to exist in all six samples. Finally, the method validation of fingerprint analysis was performed based on the relative retention time and the relative peak area of common peaks, sample stability and similarity analysis. The similarities of six coffee flavor samples were more than 0.9104 and showed that samples from different locations were consistent to some extent. The developed chromatographic fingerprint was successfully used to differentiate coffee flavor from cocoa flavor and some little difference sample prepared with coffee flavor and cocoa flavor by both similarity comparison and principal component projection analysis. The developed method can be used for quality control of coffee flavor.

4.
J Pharm Biomed Anal ; 43(4): 1507-13, 2007 Mar 12.
Artículo en Inglés | MEDLINE | ID: mdl-17118604

RESUMEN

A fast, accurate, sensitive, selective and reliable method using reversed-phase high-performance liquid chromatography-mass spectrometry coupling with an electrospray ionization interface was developed and validated for the determination of finasteride in human plasma. After deprotienation with acetonitrile, centrifugation, evaporation to dryness and dissolving in mobile phase, satisfactory separation was achieved on a Hypersil-Keystone C(18) reversed-phase column using a mobile phase consisting of acetonitrile-water (46:54, v/v), 0.1% acetic acid and 0.1% trifluoracetic acid. Carbamazepine (IS) was used as internal standard. This method involved the use of the [M+H](+) ions of finasteride and IS at m/z 373 and 237 with the selective ion monitoring (SIM) mode. The calibration curve was linear in the range of 0.2-120 ng ml(-1). The limit of quantification for finasteride in plasma was 0.2 ng ml(-1) with good accuracy and precision. The intra-assay precision and accuracy were in the range of 2.1-11.2% and -1.3% to 8.5%, respectively. The inter-assay precision and accuracy were in the order of 3.4-12.1% and -1.5% to 11.5%, respectively. The mean sample extract recoveries of the method were higher than 85% and 74% for finasteride and internal standard (IS), respectively. The assay has been successfully used to estimate the pharmacokinetics of finasteride after oral administration of a 5mg tablet of finasteride to 24 healthy volunteers.


Asunto(s)
Cromatografía Liquida/métodos , Inhibidores Enzimáticos/sangre , Inhibidores Enzimáticos/farmacocinética , Finasterida/sangre , Finasterida/farmacocinética , Espectrometría de Masa por Ionización de Electrospray/métodos , Administración Oral , Adolescente , Adulto , Carbamazepina/química , Cromatografía Liquida/instrumentación , Inhibidores Enzimáticos/administración & dosificación , Inhibidores Enzimáticos/química , Finasterida/administración & dosificación , Finasterida/química , Humanos , Masculino , Estructura Molecular , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Comprimidos , Factores de Tiempo
5.
Anal Chim Acta ; 575(2): 236-45, 2006 Aug 11.
Artículo en Inglés | MEDLINE | ID: mdl-17723597

RESUMEN

A combined approach of subwindow factor analysis and orthogonal projection resolution was used to analyze the volatile components of cut tobacco samples from different sources. After extracted with simultaneous distillation and extraction method, the volatile components in cut tobacco from five different locations were detected by GC-MS. Then, the qualitative and quantitative analysis of the volatile components of cut tobacco from Changde area was completed with the help of subwindow factor analysis resolving two-dimensional original data into pure mass spectra and chromatograms. One hundred and two volatile components among 138 separated peaks were identified and quantified, accounting for about 88.90% of the total content. Finally, orthogonal projection method was used to extract the common peaks from different locations. Among the identified components, there were 74 components coexisting in five studied samples although the relative content of each component showed difference to some extent. The results showed a fair consistency in their GC-MS fingerprints. It was the first time to apply orthogonal projection method to compare different cut tobacco samples, and it reduced the burden of qualitative analysis as well as the subjectivity. The obtained results proved the combined approach powerful for the analysis of complex cut tobacco samples. The developed method can be used to compare the sameness and differences of cut tobacco from different sources and for quality control of cigarette production and materials.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA