Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 42
Filtrar
1.
Adv Mater ; : e2402170, 2024 Apr 08.
Artículo en Inglés | MEDLINE | ID: mdl-38587064

RESUMEN

The rapid advancement of prevailing communication/sensing technologies necessitates cost-effective millimeter-wave arrays equipped with a massive number of phase-shifting cells to perform complicated beamforming tasks. Conventional approaches employing semiconductor switch/varactor components or tunable materials encounter obstacles such as quantization loss, high cost, high complexity, and limited adaptability for realizing large-scale arrays. Here, a low-cost, ultrathin, fast-response, and large-scale solution relying on metasurface concepts combined together with liquid crystal (LC) materials requiring a layer thickness of only 5 µm is reported. Rather than immersing resonant structures in LCs, a joint material-circuit-based strategy is devised, via integrating deep-subwavelength-thick LCs into slow-wave structures, to achieve constitutive metacells with continuous phase shifting and stable reflectivity. An LC-facilitated reconfigurable metasurface sub-system containing more than 2300 metacells is realized with its unprecedented comprehensive wavefront manipulation capacity validated through various beamforming functions, including beam focusing/steering, reconfigurable vortex beams, and tunable holograms, demonstrating a milli-second-level function-switching speed. The proposed methodology offers a paradigm shift for modulating electromagnetic waves in a non-resonating broadband fashion with fast-response and low-cost properties by exploiting functionalized LC-enabled metasurfaces. Moreover, this extremely agile metasurface-enabled antenna technology will facilitate a transformative impact on communication/sensing systems and empower new possibilities for wavefront engineering and diffractive wave calculation/inference.

2.
Artículo en Inglés | MEDLINE | ID: mdl-38594218

RESUMEN

PURPOSE: The study object was to determine the relationship between leptin and diabetes. METHODS: We searched for the literature on the relationship between leptin and diabetes from PubMed, EMBASE, Cochrane Library, and CNKI databases. We carried out the meta-analysis by calculating the Std. Mean Difference (SMD) and 95% confidence intervals (CIs) to study the relationship between leptin and diabetes. We performed the Chi-square-based Q test and I2 statistics to evaluate the potential heterogeneity, and the sensitivity analysis was performed to evaluate the stability of our results. Moreover, Begg's test was performed to evaluate the publication bias. RESULTS: There are 10 studies in this study for meta-analysis, which include 1879 patients (diabetic (n = 1024); and nondiabetic patients (n = 855)). The results indicated that the levels of serum leptin were significantly increased in patients with diabetes (SMD = 1.78, 95% CI [0.81, 2.76]), especially those with gestational diabetes mellitus compared with controls (SMD = 3.03, 95% CI [1.21, 4.86]). However, the results showed that there was no difference in serum leptin levels between type 2 diabetes and controls (SMD = 0.34, 95% CI [-1.06, 1.74]). CONCLUSIONS: Our analysis indicated that the levels of serum leptin were significantly elevated in patients with diabetes especially those with gestational diabetes mellitus compared with controls.

3.
Clin Oral Implants Res ; 35(6): 598-608, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38517053

RESUMEN

OBJECTIVES: To systematically analyze the accuracy of robotic surgery for dental implant placement. MATERIALS AND METHODS: PubMed, Embase, and Cochrane CENTRAL were searched on October 25, 2023. Model studies or clinical studies reporting the accuracy of robotic surgery for dental implant placement among patients with missing or hopeless teeth were included. Risks of bias in clinical studies were assessed. Meta-analyses were undertaken. RESULTS: Data from 8 clinical studies reporting on 109 patients and 242 implants and 13 preclinical studies were included. Positional accuracy was measured by comparing the implant plan in presurgery CBCT and the actual implant position in postsurgery CBCT. For clinical studies, the pooled (95% confidence interval) platform deviation, apex deviation, and angular deviation were 0.68 (0.57, 0.79) mm, 0.67 (0.58, 0.75) mm, and 1.69 (1.25, 2.12)°, respectively. There was no statistically significant difference between the accuracy of implants placed in partially or fully edentulous patients. For model studies, the pooled platform deviation, apex deviation, and angular deviation were 0.72 (0.58, 0.86) mm, 0.90 (0.74, 1.06) mm, and 1.46 (1.22, 1.70)°, respectively. No adverse event was reported. CONCLUSION: Within the limitation of the present systematic review, robotic surgery for dental implant placement showed suitable implant positional accuracy and had no reported obvious harm. Both robotic systems and clinical studies on robotic surgery for dental implant placement should be further developed.


Asunto(s)
Implantación Dental Endoósea , Implantes Dentales , Procedimientos Quirúrgicos Robotizados , Humanos , Procedimientos Quirúrgicos Robotizados/métodos , Implantación Dental Endoósea/métodos , Tomografía Computarizada de Haz Cónico
4.
Artículo en Inglés | MEDLINE | ID: mdl-38517307

RESUMEN

OBJECTIVES: The present study aimed to systematically review the studies comparing the accuracy of intraoral scan (IOS) and conventional implant impressions (CI) in completely edentulous patients. MATERIALS AND METHODS: Electronic searches were performed in PubMed, Embase and Cochrane CENTRAL up to December 1, 2023. Clinical studies and in vitro studies reporting the accuracy of digital full arch impressions were included. The primary outcome is the 3-dimensional deviations between the study reference models. A risk of bias assessment was performed for clinical studies. A stratified meta-analysis and a single-armed meta-analysis were conducted. RESULTS: A total of 49 studies were included, with 8 clinical studies and 41 in vitro studies. For comparison between IOS and conventional impressions, studies were categorized into two groups based on the different measurement methods employed: RMS and CMM. In studies using RMS, the result favored the IOS in the unparalleled situation with the mean difference of -99.29 µm (95% CI: [-141.38, -57.19], I2 = 81%), while the result was opposite with the mean difference of 13.62 µm (95% CI: [10.97, 16.28], I2 = 26%) when implants were paralleled. For different brands of IOS, the accuracy ranged from 76.11 µm (95% CI: [42.36, 109.86]) to 158.63 µm (95% CI: [-14.68, 331.93]). CONCLUSIONS: Accuracy of intraoral scan is clinically acceptable in edentulous arches, especially for unparalleled implants. More clinical studies are needed to verify the present finding.

5.
J Clin Periodontol ; 51(1): 24-32, 2024 01.
Artículo en Inglés | MEDLINE | ID: mdl-37872750

RESUMEN

AIM: To compare the implant accuracy, safety and morbidity between robot-assisted and freehand dental implant placement. MATERIALS AND METHODS: Subjects requiring single-site dental implant placement were recruited. Patients were randomly allocated to freehand implant placement and robot-assisted implant placement. Differences in positional accuracy of the implant, surgical morbidity and complications were assessed. The significance of intergroup differences was tested with an intention-to-treat analysis and a per-protocol (PP) analysis (excluding one patient due to calibration error). RESULTS: Twenty patients (with a median age of 37, 13 female) were included. One subject assigned to the robotic arm was excluded from the PP analysis because of a large calibration error due to the dislodgement of the index. For robot-assisted and freehand implant placement, with the PP analysis, the median (25th-75th percentile) platform global deviation, apex global deviation and angular deviation were 1.23 (0.9-1.4) mm/1.9 (1.2-2.3) mm (p = .03, the Mann-Whitney U-test), 1.40 (1.1-1.6) mm/2.1 (1.7-3.9) mm (p < .01) and 3.0 (0.9-6.0)°/6.7 (2.2-13.9)° (p = .08), respectively. Both methods showed limited damage to the alveolar ridge and had similar peri- and post-operative morbidity and safety. CONCLUSIONS: Robot-assisted implant placement enabled greater positional accuracy of the implant compared to freehand placement in this pilot trial. The robotic system should be further developed to simplify surgical procedures and improve accuracy and be validated in properly sized trials assessing the full spectrum of relevant outcomes.


Asunto(s)
Implantes Dentales , Robótica , Cirugía Asistida por Computador , Humanos , Femenino , Proyectos Piloto , Tecnología Háptica , Implantación Dental Endoósea/métodos , Tomografía Computarizada de Haz Cónico , Diseño Asistido por Computadora
6.
Heliyon ; 9(11): e20853, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37928010

RESUMEN

Background: Iodiene-131 (131I) treatment is the primary therapeutic approach for imaging 131I-avid pulmonary metastases. The response to radioiodine (RAI) treatment is an important prognostic factor in patients with pulmonary metastases from differentiated thyroid cancer (DTC). Patients who achieve an excellent response (ER) to 131I treatment show significantly reduced disease-related mortality. This study aimed to retrospectively analyse the clinical data and therapeutic effects of 131I treatment in patients with DTC and pulmonary metastases and to screen out the clinical factors affecting ER. Materials and methods: The study included a total of 75 patients with exclusively Iodine-131 avid (131I-avid) pulmonary metastases who underwent 131I treatment. Relevant clinical data for these patients were collected. Following treatment, the status of DTC metastatic lesions was categorized as follows: excellent response (ER), biochemical incomplete response (BIR), structural incomplete response (SIR), or indeterminate response (IDR). Gender, age at diagnosis, pathological type, stages (TNM), stimulated thyroglobulin (sTg) value before initial 131I treatment, metastatic nodule size, and type of post-treatment whole body scan (Rx-WBS) were recorded. Mono-factor analysis and binary logistic regression analyses were used to identify the factors that might affect the ER in DTC pulmonary metastases. The receiver operating characteristic (ROC) curve of the sTg value was used to predict the ER of 131I treatment. Results: All 75 patients with exclusively 131I-avid pulmonary metastases received 131I treatment and underwent follow-up. Out of the 75 patients, 26 achieved ER, resulting in an excellent response rate of 34.7 % (26/75). Among them, 25 (25/26, 96.2 %) achieved an ER after undergoing two rounds of 131I treatment. Binary logistic regression analysis showed that the factors influencing DTC pulmonary metastases excellent response were lower sTg levels [odds ratio (OR) = 0.998, P < 0.001], micronodular metastases (OR = 0.349, P = 0.001) and focal distribution on Rx-WBS imaging (OR = 0.113, P = 0.001). The area under the ROC curve for sTg value predicting ER was 0.876, and the cut-off value was 26.84 ng/mL, with a sensitivity and specificity of 87.9 % and 80.3 %, respectively. Conclusions: 131I treatment is effective for 131I-avid pulmonary metastases of DTC. Some patients who underwent 131I treatment achieved ER. Most patients with ER were obtained after two rounds of 131I treatments. Patients with sTg values before initial 131I treatment lower than 26.84 ng/mL, micronodular metastases, and focal distribution on Rx-WBS imaging were more likely to achieve ER.

7.
Front Pharmacol ; 14: 1288883, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-38026996

RESUMEN

Background: Ovarian cancer (OC) is the second most common gynecological malignancy and has a high mortality rate. The current chemotherapeutic drugs have the disadvantages of drug resistance and side effects. Myricetin, a kind of natural compound, has the advantages of easy extraction, low price, and fewer side effects. Multiple studies have demonstrated the anti-cancer properties of myricetin. However, its impact on OC is still unknown and needs further investigation. Therefore, this study aimed to elucidate the mechanism by which myricetin suppresses transforming growth factor-ß (TGF-ß) -induced epithelial-to-mesenchymal transition (EMT) in OC through in vivo and in vitro experiments. Methods: In vitro experiments were conducted to evaluate the effects of myricetin on cell proliferation and apoptosis using CCK8 assay, plate clonal formation assay, and flow cytometry. Western blot was employed to evaluate the expression levels of caspase-3, PARP, and the MAPK/ERK and PI3K/AKT signaling pathways. Wound healing, transwell, western blot and immunofluorescence assay were used to detect TGF-ß-induced cell migration, invasion, EMT and the levels of Smad3, MAPK/ERK, PI3K/AKT signaling pathways. Additionally, a mouse xenograft model was established to verify the effects of myricetin on OC in vivo. Results: Myricetin inhibited OC proliferation through MAPK/ERK and PI3K/AKT signaling pathways. Flow cytometry and western blot analyses demonstrated that myricetin promoted apoptosis by increasing the expression of cleaved-PARP and cleaved-caspase-3 and the ratio of Bax/Bcl-2 in OC. Furthermore, myricetin suppressed the TGF-ß-induced migration and invasion by transwell and wound healing assays. Mechanistically, western blot indicated that myricetin reversed TGF-ß-induced metastasis through Smad3, MAPK/ERK and PI3K/AKT signaling pathway. In vivo, myricetin significantly repressed OC progression and liver and lung metastasis. Conclusion: Myricetin exhibited inhibitory effects on OC progression and metastasis both in vivo and in vitro. And it also reversed TGF-ß-induced EMT through the classical and non-classical Smad signaling pathways.

8.
Fish Physiol Biochem ; 49(5): 895-910, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37542703

RESUMEN

The aim of this study was to investigate the splenic tissue damage of environmental biological drug avermectin to freshwater cultured carp and to evaluate the effect of silybin on the splenic tissue damage of carp induced by avermectin. A total of 60 carp were divided into 4 groups with 15 carp in each group, including the control group fed with basic diet, experimental group fed with basal diet and exposed to avermectin (avermectin group), experimental group fed with basal diet supplement silybin (silybin group), and experimental group fed with basal diet supplement silybin and exposed to avermectin (silybin + avermectin group). The whole test period lasted for 30 days, and spleen tissue was collected for analysis. In this study, H&E staining, mitochondrial purification and membrane potential detection, ATP detection, DHE staining, biochemical tests, qPCR, immunohistochemistry, and apoptosis staining were used to evaluate the biological processes of spleen tissue injury, mitochondrial function, oxidative stress, apoptosis, and endoplasmic reticulum stress. The results show that silybin protected carp splenic tissue damage caused by chronic avermectin exposure, decreased mitochondrial membrane potential, decreased ATP content, ROS accumulation, oxidative stress, apoptosis, and endoplasmic reticulum stress. Silybin may ameliorate the splenic tissue damage of cultured freshwater carp caused by environmental biopesticide avermectin by alleviating mitochondrial dysfunction and inhibiting PERK-ATF4-CHOP-driven mitochondrial apoptosis. Adding silybin into the diet becomes a feasible strategy to resist the pollution of avermectin and provides a theoretical basis for creating a good living environment for freshwater carp.


Asunto(s)
Carpas , Bazo , Animales , Silibina/farmacología , Apoptosis , Transducción de Señal , Adenosina Trifosfato
9.
Clin Oral Implants Res ; 34(8): 839-849, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-37309242

RESUMEN

OBJECTIVES: Multiple generations of medical robots have revolutionized surgery. Their application to dental implants is still in its infancy. Co-operating robots (cobots) have great potential to improve the accuracy of implant placement, overcoming the limitations of static and dynamic navigation. This study reports the accuracy of robot-assisted dental implant placement in a preclinical model and further applies the robotic system in a clinical case series. MATERIALS AND METHODS: In model analyses, the use of a lock-on structure at robot arm-handpiece was tested in resin arch models. In a clinical case series, patients with single missing teeth or edentulous arch were included. Robot-assisted implant placement was performed. Surgery time was recorded. Implant platform deviation, apex deviation, and angular deviation were measured. Factors influencing implant accuracy were analyzed. RESULTS: The in vitro results showed that with a lock-on structure, the mean (SD) of platform deviation, apex deviation, and angular deviation were 0.37 (0.14) mm, 0.44 (0.17) mm, and 0.75 (0.29)°, respectively. Twenty-one patients (28 implants) were included in the clinical case series, 2 with arches and 19 with single missing teeth. The median surgery time for single missing teeth was 23 (IQ range 20-25) min. The surgery time for the two edentulous arches was 47 and 70 min. The mean (SD) of platform deviation, apex deviation, and angular deviation was 0.54 (0.17) mm, 0.54 (0.11) mm, and 0.79 (0.22)° for single missing teeth and for 0.53 (0.17) mm, 0.58 (0.17) mm, and 0.77 (0.26)° for an edentulous arch. Implants placed in the mandible had significantly larger apex deviation than those in the maxilla. CONCLUSION: Cobot-assisted dental implant placement showed excellent positional accuracy and safety in both the in vitro study and the clinical case series. More technological development and clinical research are needed to support the introduction of robotic surgery in oral implantology. Trial registered in ChiCTR2100050885.


Asunto(s)
Implantes Dentales , Boca Edéntula , Robótica , Cirugía Asistida por Computador , Pérdida de Diente , Humanos , Diseño Asistido por Computadora , Tomografía Computarizada de Haz Cónico , Implantación Dental Endoósea/métodos , Tecnología Háptica , Imagenología Tridimensional , Boca Edéntula/cirugía , Cirugía Asistida por Computador/métodos
10.
Int J Oral Maxillofac Implants ; 38(2): 239-250, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37083916

RESUMEN

Purpose: To systematically analyze the outcomes of immediate implant placement (IIP) with bone grafting in the esthetic area. Materials and Methods: PubMed, Embase, and Cochrane CENTRAL were searched. Prospective studies reporting midfacial soft tissue recession (primary outcome) of single-tooth IIP with bone grafting in the esthetic area were included. Risks of bias were assessed. Meta-analysis, sensitivity analysis, and meta-regression were undertaken. Results: A total of 13 studies and 421 patients were included, with a follow-up length of 1 to 10 years in function. The weighted mean (95% CI) of midfacial soft tissue recession was 0.33 (0.21, 0.46) mm and 0.54 (0.16, 0.93) mm after 1 year and 5 years in function. Meta-regression indicated that after 1 year in function, there was 0.33 mm less midfacial soft tissue recession with soft tissue grafting (P = .021), while there was 0.58 mm more soft tissue recession (P = .007) in defect extraction sockets. Implant survival was 97.8%, and all failures were early failures. Peri-implant soft and hard tissue stability, peri-implant health, esthetic outcomes, and patient satisfaction were predictable within the follow-up period. Conclusion: Midfacial soft tissue recession showed an ongoing status in IIP with bone grafting in the esthetic area within 5 years in function. For extraction sockets with a thin gingival biotype or deficient buccal bone wall, soft tissue grafting was recommended.


Asunto(s)
Implantes Dentales de Diente Único , Implantes Dentales , Recesión Gingival , Carga Inmediata del Implante Dental , Humanos , Implantación Dental Endoósea/efectos adversos , Implantes Dentales/efectos adversos , Estudios Prospectivos , Trasplante Óseo , Estética Dental , Resultado del Tratamiento , Recesión Gingival/cirugía
11.
Opt Express ; 31(5): 7120-7133, 2023 Feb 27.
Artículo en Inglés | MEDLINE | ID: mdl-36859849

RESUMEN

We theoretically propose a scheme of the nonreciprocal conversion device between photons of two arbitrary frequencies in a hybrid cavity optomechanical system, where two optical cavities and two microwave cavities are coupled to two different mechanical resonators via radiation pressure. Two mechanical resonators are coupled together via the Coulomb interaction. We study the nonreciprocal conversions between both the same and different types of frequency photons. The device is based on multichannel quantum interference to break the time-reversal symmetry. Our results show the perfect nonreciprocity conditions. By adjusting the Coulomb interaction and the phase differences, we find that the nonreciprocity can be modulated and even transformed into reciprocity. These results provide new insight into the design of nonreciprocal devices, including isolators, circulators, and routers in quantum information processing and quantum networks.

12.
Pathogens ; 12(1)2023 01 06.
Artículo en Inglés | MEDLINE | ID: mdl-36678450

RESUMEN

The mosquito Aedes albopictus can transmit various arboviral diseases, posing a severe threat to human health. As an environmentally friendly method, sterile insect technology (SIT) is considered an alternative to traditional methods such as chemical pesticides to control Ae. albopictus. In SIT, the sterility of male mosquitoes can be achieved by γ-ray or X-ray radiation. Compared with γ-rays, X-rays are easier to obtain, cheaper, and less harmful. However, there is a lack of comparative assessment of these two types of radiation for SIT under the same controlled conditions. Here, we compared the effects of X-ray and γ-ray radiation on the sterility of Ae. albopictus males under laboratory-controlled conditions. Neither type of radiation affected the number of eggs but significantly reduced the survival time and hatch rate. The same dose of γ-rays caused a higher sterility effect on males than X-rays but had a more significant impact on survival. However, X-rays could achieve the same sterility effect as γ-rays by increasing the radiation dose. For example, X-rays of 60 Gy induced 99% sterility, similar to γ-rays of 40 Gy. In the test of male mating competitiveness, the induced sterility and the male mating competitiveness index were also identical at the same release ratio (sterile males/fertile males). At a release ratio of 7:1, nearly 80% of eggs failed to hatch. Sterile males produced by X-ray and γ-ray radiation had similar male competitiveness in competition with field males. In conclusion, a higher dose of X-rays is required to achieve the same sterility effect, compared to γ-rays. When γ-rays are not readily available, high-dose X-rays can be used instead. This study provides data supporting the selection of more suitable radiation for the field release of sterile male mosquitoes.

13.
Food Chem ; 411: 135448, 2023 Jun 15.
Artículo en Inglés | MEDLINE | ID: mdl-36709641

RESUMEN

Postharvest chilling injury (CI) of fruit, including peaches, is a huge challenge to horticultural product preservation. Microwave irradiation can be used as a physiological regulator due to the thermal effects; however, its non-thermal effects on the CI of postharvest fruit remain unclear. Thus, the physiological attributes and metabolisms involving phenolics, fatty acids, and sugars were compared between 'Zhongtao No.9' peaches treated with microwave irradiation at 45.5 W for different durations and control. Microwave treatment especially at 45.5 W for 7 min without inducing thermal effects could significantly inhibit internal browning caused by CI, concomitant with reduced total phenolic content. Moreover, the maintenance of membrane stability was indicated by a boosted double bond index, which may be attributed to the inhibition of membrane lipid degradation, and sucrose accumulation. In summary, the non-thermal effects of microwave irradiation contribute to CI alleviation through restraining phenolic content and maintaining membrane stability in peach fruit.


Asunto(s)
Prunus persica , Prunus persica/metabolismo , Frutas/química , Microondas , Azúcares/análisis , Ácidos Grasos/análisis , Frío
14.
J Clin Periodontol ; 50(4): 533-546, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-36632002

RESUMEN

AIM: To evaluate the relative efficacy and confidence in the precision of the results of different surgical interventions for immediate implant placement in the anterior area. MATERIALS AND METHODS: Electronic searches were performed in PubMed, Embase, and Cochrane CENTRAL. Randomized controlled trials comparing different surgical techniques in anterior jaws for type 1 implant placement were included. Outcome measures included implant survival (primary outcome), buccal bone thickness (BBT) reduction, and mid-facial soft tissue recession (MSTR). Risks of bias assessment, network meta-analysis (NMA), sensitivity analysis, and quality-of-evidence assessment were performed. RESULTS: Twenty-two studies reporting on 948 subjects and 5 surgical interventions were included. Fourteen early failures were reported. Compared with open-flap surgery without tissue augmentation (F-N) and looking at BBT preservation, NMA showed that there was moderate confidence that flapless surgery with hard tissue augmentation (FL-HTA) was better than flapless surgery without tissue augmentation (FL-N) or open-flap surgery with hard tissue augmentation (F-HTA) (mean difference -0.8 mm, 95% confidence interval: -1.1 to -0.5 mm; -0.6 mm, -0.9 to -0.4 mm; and -0.5 mm, -0.7 to -0.3 mm, respectively). There was moderate confidence that flapless surgery with hard and soft tissue augmentation (FL-HTA&STA) could significantly prevent MSTR compared with FL-HTA (-0.5 mm, -0.7 to -0.3 mm) and FL-N (-0.6 mm, -1.2 to -0.04 mm). However, there was no significant additional benefit in BBT with the FL-HTA&STA approach compared to the FL-HTA approach (-0.30 mm, -0.81 to 0.21 mm). CONCLUSIONS: For immediate implant placement in the anterior areas, the FL-HTA approach better preserves BBT (moderate confidence); adding STA improves the stability of the mid-facial soft tissue level (moderate confidence) but at the expense of BBT (low confidence).


Asunto(s)
Implantes Dentales , Carga Inmediata del Implante Dental , Humanos , Implantación Dental Endoósea/métodos , Metaanálisis en Red , Maxilar/cirugía , Carga Inmediata del Implante Dental/métodos , Estética Dental , Ensayos Clínicos Controlados Aleatorios como Asunto
15.
J Clin Periodontol ; 50 Suppl 25: 67-82, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-35815430

RESUMEN

AIM: To evaluate outcome measures and methods of assessment in clinical studies on bone augmentation/preservation procedures for the placement of dental implants. MATERIALS AND METHODS: A systematic search was performed on three databases from January 2011 to April 2021 to identify clinical studies reporting on any type of bone augmentation/preservation procedure. The outcomes that have been used to assess efficacy or performance in each study were registered and assigned to different domains (group of outcomes). The review followed the Preferred Reporting Items for Systematic Review and Meta-Analyses statement. RESULTS: Seven-hundred and eighty-three publications were included. Only 81.8% of the papers had a clear definition of their primary outcome. The rate of complications (59.3%), implant survival (58.2%), 3D radiographic bone gain/change (30%), marginal bone level (MBL; 29%), and histological outcomes (25.5%) were the most frequently reported outcome domains. The most commonly used primary outcome was 3D radiographic bone gain/change (25.8%), followed by implant survival (13.0%). Patient-reported outcome measures (PROMs) were reported in 15.7% of studies. Differences in the reported outcomes were observed among different types of bone preservation/augmentation interventions (i.e., alveolar ridge preservation, immediate implants, horizontal and/or vertical ridge augmentation, and sinus floor augmentation). CONCLUSION: Within the past decade, great heterogeneity was observed among the outcomes considered in studies evaluating bone preservation/augmentation procedures. Three-dimensional radiographic bone gain/change was the most routinely reported main outcome variable, while PROMs were rarely reported.


Asunto(s)
Aumento de la Cresta Alveolar , Implantes Dentales , Elevación del Piso del Seno Maxilar , Humanos , Implantación Dental Endoósea/métodos , Elevación del Piso del Seno Maxilar/métodos , Trasplante Óseo/métodos , Aumento de la Cresta Alveolar/métodos , Evaluación de Resultado en la Atención de Salud
16.
Clin Oral Implants Res ; 34 Suppl 25: 68-83, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-35817421

RESUMEN

AIM: To evaluate outcome measures and methods of assessment in clinical studies on bone augmentation/preservation procedures for the placement of dental implants. MATERIALS AND METHODS: A systematic search was performed on three databases from January 2011 to April 2021 to identify clinical studies reporting on any type of bone augmentation/preservation procedure. The outcomes that have been used to assess efficacy or performance in each study were registered and assigned to different domains (group of outcomes). The review followed the Preferred Reporting Items for Systematic Review and Meta-Analyses statement. RESULTS: Seven-hundred and eighty-three publications were included. Only 81.8% of the papers had a clear definition of their primary outcome. The rate of complications (59.3%), implant survival (58.2%), 3D radiographic bone gain/change (30%), marginal bone level (MBL; 29%), and histological outcomes (25.5%) were the most frequently reported outcome domains. The most commonly used primary outcome was 3D radiographic bone gain/change (25.8%), followed by implant survival (13.0%). Patient-reported outcome measures (PROMs) were reported in 15.7% of studies. Differences in the reported outcomes were observed among different types of bone preservation/augmentation interventions (i.e., alveolar ridge preservation, immediate implants, horizontal and/or vertical ridge augmentation, and sinus floor augmentation). CONCLUSION: Within the past decade, great heterogeneity was observed among the outcomes considered in studies evaluating bone preservation/augmentation procedures. Three-dimensional radiographic bone gain/change was the most routinely reported main outcome variable, while PROMs were rarely reported.


Asunto(s)
Aumento de la Cresta Alveolar , Implantes Dentales , Elevación del Piso del Seno Maxilar , Humanos , Implantación Dental Endoósea/métodos , Elevación del Piso del Seno Maxilar/métodos , Trasplante Óseo/métodos , Aumento de la Cresta Alveolar/métodos , Evaluación de Resultado en la Atención de Salud
17.
Clin Implant Dent Relat Res ; 25(1): 3-10, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-36373737

RESUMEN

OBJECTIVES: To evaluate the clinical, radiographic, and esthetic outcomes of immediate implant placement with buccal bone dehiscence in the anterior maxilla. METHODS: In this case series, implants were inserted immediately after tooth extraction in sockets with buccal bone dehiscence. Guided bone regeneration (GBR) with a papilla preservation flap and simultaneous connective tissue grafting (CTG) was used. The following outcome variables were measured: mid-facial mucosal recession, probing depth, bleeding on probing, Pink Esthetic Score (PES), marginal bone loss, and thickness of buccal bone plate (TBP). RESULTS: 12 patients were recruited. Stable mid-facial mucosal level (-0.03 ± 0.17 mm) and excellent soft-tissue esthetic outcomes (PES, 9.17 ± 0.72) were achieved at 1 year. The TBP at platform level was 2.01 ± 0.31 mm at 1-year follow up with a resorption rate of 28.90% ± 15.14%. CONCLUSIONS: Immediate implant placement using GBR performed with a papilla preservation approach and simultaneous CTG is a feasible treatment procedure in compromised extraction sockets in the anterior region. Favorable esthetic outcomes and buccal bone thickness were obtained. Further studies were needed to evaluate the long-term tissue alteration.


Asunto(s)
Implantes Dentales de Diente Único , Implantes Dentales , Carga Inmediata del Implante Dental , Humanos , Resultado del Tratamiento , Maxilar/diagnóstico por imagen , Maxilar/cirugía , Estética Dental
18.
Clin Oral Implants Res ; 34(1): 1-12, 2023 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-36245267

RESUMEN

OBJECTIVES: Simplification and standardization of interventions are critical challenges to improving performance in implant dentistry. This study aimed to systematically identify and schematically present the evidence base of the implant dentistry surgical interventions for the anterior maxilla as a basis for further development and standardization. METHODS: Electronic searches were conducted in PubMed, Embase and Cochrane CENTRAL. Primary clinical studies reporting surgical interventions in the anterior maxilla, with a sample size of at least ten patients, were included. Bibliometric information and study details were extracted. Descriptive analysis and a mind map approach were used to describe the documentation of different surgical interventions. RESULTS: Two hundred and seventy-two studies reporting on 9001 patients were included. Within the past two decades, the number of literatures on implant placement in the anterior maxilla has increased dramatically (7 studies before 2005, 151 studies after 2016). Overall, the evidence map identified six primary operations and 33 variations. For hopeless tooth extraction, immediate implant placement was the most frequently reported (141 studies, 4670 patients); flapless implant placement with hard tissue augmentation and immediate provisionalization was the most commonly reported variation (33 studies, 987 patients). Type 3/4 implant placement (62 studies, 1902 patients) and implant site augmentation (33 studies, 788 patients) were frequently reported for missing teeth. Geographical differences were observed, with type 2 placement studies almost exclusively from Europe. CONCLUSIONS: Research on immediate implant placement was the most reported surgical intervention in the anterior maxilla. Hard tissue augmentation was frequently reported simultaneously with or before implant placement. Immediate provisionalization was mainly used for type 1 implant placement. The finding that six primary operations with 33 variations have been reported indicates the need for additional research to simplify and consolidate the surgical approach.


Asunto(s)
Implantes Dentales de Diente Único , Implantes Dentales , Carga Inmediata del Implante Dental , Humanos , Implantación Dental Endoósea , Maxilar/cirugía , Estética Dental
19.
Curr Med Sci ; 42(5): 974-980, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-36245026

RESUMEN

OBJECTIVE: The occurrence and development of inflammation are closely correlated to the polarization of macrophages. All-trans retinoic acid (ATRA) has been proven to promote the polarization of macrophages from M1 to M2, but this lacks an effective carrier to participate in the biological response. The present study aims to determine whether retinoic acid-incorporated glycol chitosan (RA-GC) nanoparticles can regulate macrophage polarization in Porphyromonas gingivalis-lipopolysaccharide (Pg-LPS)-induced inflammation. METHODS: Mouse 264.7 cell lines were treated with 1 µg/mL Pg-LPS to induce inflammation. After the effects of ATRA and RA-GC on the activity of macrophages were detected by CCK-8 assay, cells induced with Pg-LPS were assigned to the blank control group (GC) nanoparticles without ATRA, and experimental groups (GC nanoparticles loaded with different concentrations of ATRA: 1, 10 and 100 µg/mL). The effects of RA-GC on inflammatory cytokines tumor necrosis factor-α, interleukin (IL)-10 and IL-12 in macrophages were detected by enzyme-linked immunosorbent assay (ELISA). Subsequently, the effects of GC nanoparticles loaded with/without ATRA on macrophage polarization in an inflammatory environment were detected by RT-PCR and Western blotting. RESULTS: The results revealed that RA-GC had no significant effect on macrophage activity. However, RA-GC could effectively inhibit the Pg-LPS-induced inflammatory factor expression in macrophages. Meanwhile, the experimental results confirmed that RA-GC could downregulate the expression of inducible nitric oxide synthase (iNOS) (a marker of M1 macrophages) and upregulate the expression of mannose receptor and Arginase-1 (a marker of M2 macrophages) in a dose-dependent manner. CONCLUSION: The present study confirms that RA-GC can promote the M2 polarization of macrophages in an inflammatory environment, and proposes this as a promising target for the clinical treatment of Pg-LPS-related diseases.


Asunto(s)
Lipopolisacáridos , Nanopartículas , Ratones , Animales , Lipopolisacáridos/farmacología , Porphyromonas gingivalis , Óxido Nítrico Sintasa de Tipo II/genética , Óxido Nítrico Sintasa de Tipo II/metabolismo , Óxido Nítrico Sintasa de Tipo II/farmacología , Arginasa , Factor de Necrosis Tumoral alfa/metabolismo , Macrófagos/metabolismo , Inflamación/inducido químicamente , Inflamación/metabolismo , Tretinoina/farmacología , Citocinas/metabolismo , Interleucina-12
20.
Front Pharmacol ; 13: 999712, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36188568

RESUMEN

For thousands of years, the roots of Paeonia lactiflora Pall (PLP) has been considered by traditional Chinese medicine as a drug that can improve mental or emotional disorders, including depression, anxiety and affective disorders. Unfortunately, the research on the mechanism of action and active ingredients of this beneficial drug is not comprehensive. This study focused on the activity of essential oil from PLP (EOP), systematically studied the antidepressant effect of EOP for the first time, and discussed the potential mechanism of its antidepressant effect. In this study, we used a mouse model of corticosterone (CORT)-induced depression, and found that EOP had a significant antidepressant effect on the symptoms of CORT-induced depression in mice, and significantly down-regulated the levels of CRH, ACTH and cortisol in the brain tissues of mice. In addition, we found that EOP treatment alleviated CORT-induced hippocampal neuron injury in mice In vitro experiments. It was also found that EOP could inhibit CORT-induced apoptosis and improve the proliferation ability and cell viability of PC12 cells. Further, with the help of network analysis, it was revealed that PI3K-Akt might be one of the main signaling pathways of EOP against CORT-induced hippocampal neuron apoptosis. In this study, we also found that EOP up-regulated the phosphorylation of PI3K and Akt in CORT-induced mouse hippocampal neurons and PC12 cells, and promoted the nuclear transcription of Nrf2 in CORT-induced PC12 cells. In conclusion, with the integrated approach, we demonstrated that EOP exerted anti-apoptotic effects on hippocampal neurons through PI3K/Akt/Nrf2 signaling pathway.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA