Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros













Base de datos
Intervalo de año de publicación
1.
Se Pu ; 41(7): 602-609, 2023 Jul.
Artículo en Chino | MEDLINE | ID: mdl-37387281

RESUMEN

Synthetic cannabinoids (SCs), which are considered some of the most widely abused new psychoactive substances available today, are much more potent than natural cannabis and display greater efficacy. New SCs can be developed by adding substituents such as halogen, alkyl, or alkoxy groups to one of the aromatic ring systems, or by changing the length of the alkyl chain. Following the emergence of the so-called first-generation SCs, further developments have led to eighth-generation indole/indazole amide-based SCs. Given that all SCs were listed as controlled substances on July 1, 2021, the technologies used to detect these substances must be quickly improved. Due to the sheer number of SCs, the chemical diversity and the fast update speed, it is challenging to determine and identify the new SCs. In recent years, several types of indole/indazole amide-based SCs have been seized, but systematic research on these compounds remains limited. Therefore, developing rapid, sensitive, and accurate quantitative methods to determine new SCs are of great importance. Compared with high performance liquid chromatography (HPLC), ultra performance liquid chromatography (UPLC) shows higher resolution, better separation efficiency, and faster analysis speeds; thus, it can meet the demand for the quantitative analysis of indole/indazole amide-based SCs in seized materials. In this study, a UPLC method was developed for the simultaneous determination of five indole/indazole amide-based SCs, including N-(1-amino-3,3-dimethyl-1-oxobutan-2-yl)-1-butyl-1H-indazole-3-carboxamide (ADB-BUTINACA), methyl 2-(1-(4-fluorobutyl)-1H-indole-3-carboxamido)-3,3-dimethylbutanoate (4F-MDMB-BUTICA), N-(1-methoxy-3,3-dimethyl-1-oxobutan-2-yl)-1-(5-fluoropentyl)-1H-indole-3-carboxamide (5F-MDMB-PICA), methyl 3,3-dimethyl-2-(1-(pent-4-en-1-yl)-1H-indazole-3-carboxamido)butanoate (MDMB-4en-PINACA), and N-(adamantan-1-yl)-1-(4-fluorobutyl)-1H-indazole-3-carboxamide (4F-ABUTINACA) in electronic cigarette oil; these SCs have been detected with increasing frequency in seized materials in recent years. The main factors influencing the separation and detection performance of the proposed method, including the mobile phase, elution gradient, column temperature, and detection wavelength, were optimized. The proposed method successfully quantified the five SCs in electronic cigarette oil via the external standard method. The samples were extracted using methanol, and the target analytes were separated on a Waters ACQUITY UPLC CSH C18 column (100 mm×2.1 mm, 1.7 µm) at column temperature of 35 ℃ and flow rate of 0.3 mL/min. The injection volume was 1 µL. The mobile phase consisted of acetonitrile and ultrapure water, and gradient elution was employed. The detection wavelengths were 290 and 302 nm. The five SCs were completely separated within 10 min under optimized conditions and showed good linear relationships between 1-100 mg/L, with correlation coefficients (r2) of up to 0.9999. The limits of detection (LOD) and quantification (LOQ) were 0.2 and 0.6 mg/L, respectively. Precision was determined using standard solutions of the five SCs at mass concentrations of 1, 10, and 100 mg/L. The intra-day precision (n=6) was <1.5%, and the inter-day precision (n=6) was <2.2%. Accuracy was determined by spiking electronic cigarette oil with low (2 mg/L), moderate (10 mg/L), and high (50 mg/L) levels of the five SCs, with six replicates per determination. The recoveries of the five SCs were 95.5%-101.9%, and their relative standard deviations (RSDs, n=6) were 0.2%-1.5%, with accuracies ranging from -4.5% to 1.9%. The proposed method showed good performance when applied to the analysis of real samples. It is accurate, rapid, sensitive, and effective for the determination of five indole/indazole amide-based SCs in electronic cigarette oil. Thus, it satisfies the requirements for practical determination and provides a reference for the determination of SCs with similar structures by UPLC.


Asunto(s)
Cannabinoides , Sistemas Electrónicos de Liberación de Nicotina , Cromatografía Liquida , Amidas , Indazoles
2.
Anal Chem ; 91(10): 6487-6497, 2019 05 21.
Artículo en Inglés | MEDLINE | ID: mdl-31037939

RESUMEN

This study reports a novel and convenient bimodal method for label-free and signal-off detection of arsenate in environmental samples. Cobalt oxyhydroxide (CoOOH) nanoflakes with facile preparation and intrinsic peroxidase-like activity as nanozyme can efficiently catalyze the conversion of chromogenic substrate such as 2,2'-azinobis(3-ethylbenzothiazoline-6-sulfonic acid) (ABTS) with the presence of H2O2 into green-colored oxidation products. CoOOH nanoflakes can specifically bind with arsenate via electrostatic attraction and As-O bond interaction, which gives rise to inhibition of the peroxidase-like activity of CoOOH. Thus, through arsenate specific inhibition of CoOOH nanozyme toward ABTS catalysis, a simple colorimetric method was developed for arsenate detection with a detection limit of 3.72 ppb. Based on the system of CoOOH nanozyme and ABTS substrate, this colorimetric method can be converted into an electrochemical sensor for arsenate assay by the utilization of CoOOH nanoflake-modified electrode. The electrochemical measurement can be realized by chronoamperometry, which showed more sensitive and a lower limit of detection as low as 56.1 ppt. The applicability of this bimodal method was demonstrated by measuring arsenate and total arsenic in different real samples such as natural waters and soil extracted solutions, and the results are of satisfactory accuracy as confirmed by inductively coupled plasma mass spectrometry analysis. The bimodal strategy offers obvious advantages including a label-free step, convenient operation, on-site assay, low cost, and high sensitivity, which is promising for reliable detection of arsenate and total arsenic in environmental samples.


Asunto(s)
Arseniatos/química , Cobalto/química , Colorimetría/métodos , Óxidos/química , China , Técnicas Electroquímicas , Contaminantes Ambientales/química , Contaminación Ambiental , Nanoestructuras , Contaminación del Agua
3.
Biosens Bioelectron ; 97: 325-331, 2017 Nov 15.
Artículo en Inglés | MEDLINE | ID: mdl-28622643

RESUMEN

We report a sensor combining two distinguishable magnetic nanoprobes (DNA1/Fe3O4 NPs/Thi and DNA2/Fe3O4 NPs/Fc) with target-triggered hybridization chain reaction (HCR) strategy for the simultaneous detection of microRNA-141 (miR-141) and microRNA-21 (miR-21). In the presence of targets, the thiol-modified hairpin capture probes (HCP1 and HCP2) specifically hybridize with miR-141 and miR-21 on a gold electrode, leading to the conformation change of HCP1 and HCP2, respectively. The conformation change subsequently triggers HCR to generate plentiful bonding sequences of magnetic nanoprobes. Thus, numerous thionine (Thi) modified DNA1/Fe3O4 NPs/Thi and ferrocene carboxaldehyde (Fc-CHO) modified DNA2/Fe3O4 NPs/Fc are captured by the well-designed HCR, via DNA hybridization respectively, giving rise to the dual magnified response of currents. The increase in the electrochemical currents at different potentials of the two magnetic nanoprobes enables us to simultaneously and quantitatively detect miR-141 and miR-21. Target-triggered HCR increases the amount of captured nanoprobes due to the increasing number of bonding sequences, greatly amplifying the currents of the two magnetic nanoprobes in the presence of targets, and ultimately realizing the dual signal amplification with increased sensitivity. The sensor can be applied for detecting miRNAs in cell lysates, thus, promising to be a clinic diagnosis of cancers by means of simultaneous detection of a variety of miRNA biomarkers.


Asunto(s)
Técnicas Electroquímicas/métodos , Nanopartículas de Magnetita/química , MicroARNs/análisis , Hibridación de Ácido Nucleico/métodos , Técnicas Biosensibles/métodos , Electrodos , Compuestos Ferrosos/química , Humanos , Células MCF-7 , Nanopartículas de Magnetita/ultraestructura , Metalocenos/química
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA