Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Artículo en Inglés | MEDLINE | ID: mdl-39087831

RESUMEN

The development of wearable electronic devices for human health monitoring requires materials with high mechanical performance and sensitivity. In this study, we present a novel transparent tissue-like ionogel-based wearable sensor based on silver nanowire-reinforced ionogel nanocomposites, P(AAm-co-AA) ionogel-Ag NWs composite. The composite exhibits a high stretchability of 605% strain and a moderate fracture stress of about 377 kPa. The sensor also demonstrates a sensitive response to temperature changes and electrostatic adsorption. By encapsulating the nanocomposite in a polyurethane transparent film dressing, we address issues such as skin irritation and enable multidirectional stretching. Measuring resistive changes of the ionogel nanocomposite in response to corresponding strain changes enables its utility as a highly stretchable wearable sensor with excellent performance in sensitivity, stability, and repeatability. The fabricated pressure sensor array exhibits great proficiency in stress distribution, capacitance sensing, and discernment of fluctuations in both external electric fields and stress. Our findings suggest that this material holds promise for applications in wearable and flexible strain sensors, temperature sensors, pressure sensors, and actuators.

2.
Environ Health ; 23(1): 64, 2024 Jul 13.
Artículo en Inglés | MEDLINE | ID: mdl-39003460

RESUMEN

BACKGROUND: Brominated Flame Retardants (BFRs) have attracted widespread concern due to their environmental persistence and potential toxicity. This study aims to examine the association between BFRs exposure and hypertension. METHODS: We used data from the National Health and Nutrition Examination Survey (NHANES) spanning 2005 to 2016 for the cross-sectional analysis. To evaluate the individual and combined impacts of BFRs exposure on hypertension, we utilized multivariate models, including generalized additive models, weighted quantile sum (WQS) regression, and Bayesian kernel machine regression (BKMR) models. RESULTS: 9882 individuals (48% male) aged ≥ 20 were included in the final analysis, of whom 4114 had hypertension. After controlling for potential covariates, higher serum concentrations of PBDE100 (OR: 1.26; 95% CI: 1.01, 1.57) and PBDE153 (OR: 1.50; 95% CI: 1.18, 1.88) were significantly associated with hypertension. A nonlinear relationship between PBDE28 and hypertension was observed (P = 0.03). Moreover, BFRs mixture were positively associated with the prevalence of hypertension in both the WQS (ß:1.09; 95% CI: 1.02, 1.17; P = 0.02) and BKMR models. CONCLUSION: Our study suggested that BFRs exposure is positively associated with hypertension in the general population. To confirm this association and elucidate the mechanisms, further research is required.


Asunto(s)
Exposición a Riesgos Ambientales , Contaminantes Ambientales , Retardadores de Llama , Éteres Difenilos Halogenados , Hipertensión , Encuestas Nutricionales , Humanos , Retardadores de Llama/análisis , Femenino , Masculino , Hipertensión/epidemiología , Hipertensión/inducido químicamente , Adulto , Persona de Mediana Edad , Éteres Difenilos Halogenados/sangre , Estudios Transversales , Exposición a Riesgos Ambientales/efectos adversos , Contaminantes Ambientales/sangre , Estados Unidos/epidemiología , Adulto Joven , Anciano , Bifenilos Polibrominados/sangre
3.
Nanoscale ; 16(32): 15170-15175, 2024 Aug 15.
Artículo en Inglés | MEDLINE | ID: mdl-39052086

RESUMEN

Gallium nitride (GaN) exhibits various potential applications in optics and optoelectronics due to its outstanding physical characteristics, including a wide direct bandgap, strong deep-ultraviolet emission, and excellent electron transport properties. However, research on the piezoelectric and related properties of GaN nanosheets are scarce, as previous small-scale GaN investigations have mainly concentrated on nanowires and nanotubes. Here, we report a strategy for growing 2D GaN nanosheets using chemical vapor deposition on Ga/W liquid-phase substrates. Additionally, utilizing scanning probe techniques, it has been observed that 700 nm-thick GaN nanosheets demonstrate a piezoelectric constant of deff33 = 1.53 ± 0.21 pm V-1 and possess the capability to effectively modulate the Schottky barrier. The piezoelectric characteristics of 2D GaN are offering new options for innovative applications in various fields, including energy harvesting, electronics, sensing, and communications.

4.
Nat Commun ; 15(1): 4777, 2024 Jun 05.
Artículo en Inglés | MEDLINE | ID: mdl-38839748

RESUMEN

Drawing inspiration from cohesive integration of skeletal muscles and sensory skins in vertebrate animals, we present a design strategy of soft robots, primarily consisting of an electronic skin (e-skin) and an artificial muscle. These robots integrate multifunctional sensing and on-demand actuation into a biocompatible platform using an in-situ solution-based method. They feature biomimetic designs that enable adaptive motions and stress-free contact with tissues, supported by a battery-free wireless module for untethered operation. Demonstrations range from a robotic cuff for detecting blood pressure, to a robotic gripper for tracking bladder volume, an ingestible robot for pH sensing and on-site drug delivery, and a robotic patch for quantifying cardiac function and delivering electrotherapy, highlighting the application versatilities and potentials of the bio-inspired soft robots. Our designs establish a universal strategy with a broad range of sensing and responsive materials, to form integrated soft robots for medical technology and beyond.


Asunto(s)
Robótica , Robótica/instrumentación , Robótica/métodos , Animales , Biomimética/métodos , Biomimética/instrumentación , Humanos , Prótesis e Implantes , Piel , Diseño de Equipo , Músculo Esquelético/fisiología , Dispositivos Electrónicos Vestibles
5.
Lab Chip ; 24(13): 3294-3304, 2024 Jun 25.
Artículo en Inglés | MEDLINE | ID: mdl-38864519

RESUMEN

On-demand drug delivery holds great promise to optimize pharmaceutical efficacy while minimizing the side effects. However, existing on-demand drug delivery systems often require complicated manufacturing processes that preclude their wide implementation of a broad range of drugs. In this work, we demonstrate the introduction of MXene-coated microneedles (MNs) into bioelectronics for digitally controllable gate-valve drug delivery. MXenes, featuring high electronic conductivity, excellent biocompatibility, and solution processibility, enable low-cost scalability for printable bioelectronics. In an electrolytic state (e.g., body fluid), the coated MXene is oxidized and desorbed due to redox reactions caused by electrical bias, allowing the underlying drug to be controllably released. The MXene-incorporated drug delivery system not only demonstrates excellent biocompatibility and operational stability, but also features low-cost construction and sustainable usage. Besides, these MXene-coated MNs allow both on-demand transformation and local-region customization, further increasing the structural versatility and capability of multidrug delivery systems.


Asunto(s)
Sistemas de Liberación de Medicamentos , Conductividad Eléctrica , Sistemas de Liberación de Medicamentos/instrumentación , Agua/química , Humanos , Diseño de Equipo
6.
Nanomaterials (Basel) ; 14(3)2024 Jan 27.
Artículo en Inglés | MEDLINE | ID: mdl-38334545

RESUMEN

Two-dimensional (2D) piezoelectric semiconductor materials are garnering significant attention in applications such as intelligent sensing and energy harvesting due to their exceptional physical and chemical properties. Among these, molybdenum disulfide (MoS2), a 2D wide-bandgap semiconductor, exhibits piezoelectricity in odd-layered structures due to the absence of an inversion symmetry center. In this study, we present a straightforward chemical vapor deposition (CVD) technique to synthesize monolayer MoS2 on a Si/SiO2 substrate, achieving a lateral size of approximately 50 µm. Second-harmonic generation (SHG) characterization confirms the non-centrosymmetric crystal structure of the wide-bandgap MoS2, indicative of its piezoelectric properties. We successfully transferred the triangular MoS2 to a polyethylene terephthalate (PET) flexible substrate using a wet-transfer method and developed a wide-bandgap MoS2-based micro-displacement sensor employing maskless lithography and hot evaporation techniques. Our testing revealed a piezoelectric response current of 5.12 nA in the sensor under a strain of 0.003% along the armchair direction of the monolayer MoS2. Furthermore, the sensor exhibited a near-linear relationship between the piezoelectric response current and the strain within a displacement range of 40-100 µm, with a calculated response sensitivity of 1.154 µA/%. This research introduces a novel micro-displacement sensor, offering potential for advanced surface texture sensing in various applications.

7.
Small ; 20(29): e2310768, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38342671

RESUMEN

There is a noticeable gap in the literature regarding research on halogen-substitution-regulated ferroelectric semiconductors featuring multiple phase transitions. Here, a new category of 1D perovskite ferroelectrics (DFP)2SbX5 (DFP+ = 3,3-difluoropyrrolidium, X- = I-, Br-, abbreviated as I-1 and Br-2) with twophase transitions (PTs) is reported. The first low-temperature PT is a mmmFmm2 ferroelectric PT, while the high-temperature PT is a counterintuitive inverse temperature symmetry-breaking PT. By the substitution of iodine with bromine, the Curie temperature (Tc) significantly increases from 348 K of I-1 to 374 K of Br-2. Their ferroelectricity and pyroelectricity are improved (Ps value from 1.3 to 4.0 µC cm-2, pe value from 0.2 to 0.48 µC cm-2 K-1 for I-1 and Br-2), while their optical bandgaps increased from 2.1 to 2.7 eV. A critical slowing down phenomenon is observed in the dielectric measurement of I-1 while Br-2 exhibits the ferroelastic domain. Structural and computational analyses elucidate that the order-disorder movement of cations and the distortion of the chain perovskite [SbX5]2- anions skeleton lead to PT. The semiconductor properties are determined by [SbX5]2- anions. The findings contribute to the development of ferroelectric semiconductors and materials with multiple PTs and provide materials for potential applications in the optoelectronic field.

8.
Research (Wash D C) ; 7: 0316, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38371274

RESUMEN

Transient receptor potential vanilloid family member 1 (TRPV1) has been revealed as a therapeutic target of osteoarthritis (OA), the most common deteriorating whole joint disease, by impeding macrophagic inflammation and chondrocytes ferroptosis. However, the clinical application for capsaicin as the TRPV1 agonist is largely limited by its chronic toxicity. To address this issue, we developed a bifunctional controllable magnetothermal switch targeting TRPV1 for the alleviation of OA progression by coupling of magnetic nanoparticles (MNPs) to TRPV1 monoclonal antibodies (MNPs-TRPV1). Under the alternating magnetic field (AMF) stimulation, MNPs-TRPV1 locally dissipated heat, which was sufficient to trigger the opening and activation of TRPV1, and effectively impeded macrophagic inflammation and chondrocyte ferroptosis. This magnetothermal modulation of TRPV1 simultaneously attenuated synovitis and cartilage degeneration in mice incurred by destabilization of medial meniscus surgery, indicating the delayed OA progression. Furthermore, MNPs-TRPV1 with AMF exposure remarkably reduced knee pain sensitivity, alleviated the crippled gait, and improved spontaneous ambulatory activity performance in the mice OA model. Overall, this work provides a potential pathogenesis-based precise OA therapy with temporally and spatially magnetothermal modulation of TRPV1 in a controllable manner.

9.
BMC Cardiovasc Disord ; 24(1): 37, 2024 01 08.
Artículo en Inglés | MEDLINE | ID: mdl-38191302

RESUMEN

BACKGROUND: Catheter ablation is recommended in patients with frequent and symptomatic ventricular arrhythmias (VAs) in an otherwise normal heart. Right or left outflow tract (OT) are the most common origins, and catheter ablation is highly effective with low complication rates. However, outcome of catheter ablation of VAs other than the OT (non-OTVAs) is limited. The aim of this single-center study was to assess the safety and mid-term outcome of catheter ablation for non-OTVAs. METHOD AND RESULTS: From 2013 to 2018, 251 patients who underwent catheter ablation for idiopathic non-OTVAs were enrolled and grouped according to the origins including His-Purkinje system (HPS, n = 108), papillary muscle / moderator band (PM/MB, n = 47), tricuspid annulus (TA, n = 70), and mitral annulus (MA, n = 26), 244 (97.2%) had acute elimination of VAs. The time of VAs recurrence of the single procedure was 1.69 (0.12,9.72) months, with 66% occurring within the first 3 months. The recurrence rate was significantly higher in the PM/MB group than in the TA (p = 0.025) and MA groups (p = 0.023). The single procedure success rate in all patients was 70.1%, in which 66.7%, 59.6%, 80%, and 76.9% were achieved in the HPS, PM/MB, TA, and MA groups, respectively (p = 0.284). After multiple procedures, the total success rate was 76.5% at the follow-up of 4.38 ± 2.42 years. The rate was significantly lower in the PM/MB group than in the TA group (p = 0.035). In subgroup analysis, no significant difference was observed in the recurrence rate of single procedure in patients with different VA origins within the PM/MB (log-rank test, p = 0.546). CONCLUSION: Despite a certain percentage of recurrences observed in the mid-term follow-up, catheter ablation remained feasible and effective for idiopathic non-OTVAs.


Asunto(s)
Ablación por Catéter , Músculos Papilares , Humanos , Ventrículos Cardíacos , Arritmias Cardíacas , Ablación por Catéter/efectos adversos , Válvula Mitral
10.
Res Sq ; 2023 Dec 22.
Artículo en Inglés | MEDLINE | ID: mdl-38196588

RESUMEN

Living organisms with motor and sensor units integrated seamlessly demonstrate effective adaptation to dynamically changing environments. Drawing inspiration from cohesive integration of skeletal muscles and sensory skins in these organisms, we present a design strategy of soft robots, primarily consisting of an electronic skin (e-skin) and an artificial muscle, that naturally couples multifunctional sensing and on-demand actuation in a biocompatible platform. We introduce an in situ solution-based method to create an e-skin layer with diverse sensing materials (e.g., silver nanowires, reduced graphene oxide, MXene, and conductive polymers) incorporated within a polymer matrix (e.g., polyimide), imitating complex skin receptors to perceive various stimuli. Biomimicry designs (e.g., starfish and chiral seedpods) of the robots enable various motions (e.g., bending, expanding, and twisting) on demand and realize good fixation and stress-free contact with tissues. Furthermore, integration of a battery-free wireless module into these robots enables operation and communication without tethering, thus enhancing the safety and biocompatibility as minimally invasive implants. Demonstrations range from a robotic cuff encircling a blood vessel for detecting blood pressure, to a robotic gripper holding onto a bladder for tracking bladder volume, an ingestible robot residing inside stomach for pH sensing and on-site drug delivery, and a robotic patch wrapping onto a beating heart for quantifying cardiac contractility, temperature and applying cardiac pacing, highlighting the application versatilities and potentials of the nature-inspired soft robots. Our designs establish a universal strategy with a broad range of sensing and responsive materials, to form integrated soft robots for medical technology and beyond.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...