Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros













Base de datos
Intervalo de año de publicación
1.
Front Immunol ; 15: 1376276, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38745658

RESUMEN

Background: Hepatic Inflammatory Pseudotumor (IPT) is an infrequent condition often masquerading as a malignant tumor, resulting in misdiagnosis and unnecessary surgical resection. The emerging concept of IgG4-related diseases (IgG4-RD) has gained widespread recognition, encompassing entities like IgG4-related hepatic IPT. Clinically and radiologically, corticosteroids and immunosuppressive therapies have proven effective in managing this condition. Case Presentation: A 3-year-old Chinese boy presented to the clinic with an 11-month history of anemia, fever of unknown origin, and a tender hepatic mass. Blood examinations revealed chronic anemia (Hb: 6.4 g/L, MCV: 68.6 fl, MCH: 19.5 pg, reticulocytes: 1.7%) accompanied by an inflammatory reaction and an elevated serum IgG4 level (1542.2 mg/L). Abdominal contrast-enhanced computed tomography unveiled a 7.6 cm low-density mass in the right lateral lobe, while magnetic resonance imaging demonstrated slight hypointensity on T1-weighted images and slight hyperintensity on T2-weighted images, prompting suspicion of hepatic malignancy. A subsequent liver biopsy revealed a mass characterized by fibrous stroma and dense lymphoplasmacytic infiltration. Immunohistochemical analysis confirmed the presence of IgG4-positive plasma cells, leading to the diagnosis of IgG4-related hepatic IPT. Swift resolution occurred upon initiation of corticosteroid and mycophenolate mofetil therapies. Conclusion: This study underscores the diagnostic approach to hepatic IPT, utilizing histopathology, immunostaining, imaging, serology, organ involvement, and therapeutic response. Early histological examination plays a pivotal role in clinical guidance, averting misdiagnosis as a liver tumor and unnecessary surgical interventions.


Asunto(s)
Granuloma de Células Plasmáticas , Enfermedad Relacionada con Inmunoglobulina G4 , Inmunoglobulina G , Humanos , Masculino , Granuloma de Células Plasmáticas/diagnóstico , Granuloma de Células Plasmáticas/inmunología , Granuloma de Células Plasmáticas/tratamiento farmacológico , Preescolar , Inmunoglobulina G/sangre , Inmunoglobulina G/inmunología , Enfermedad Relacionada con Inmunoglobulina G4/diagnóstico , Hepatopatías/diagnóstico , Hepatopatías/inmunología , Diagnóstico Diferencial , Hígado/patología , Hígado/diagnóstico por imagen , Hígado/inmunología , Tomografía Computarizada por Rayos X , Biopsia , Inmunosupresores/uso terapéutico
2.
J Chromatogr A ; 1720: 464794, 2024 Apr 12.
Artículo en Inglés | MEDLINE | ID: mdl-38484640

RESUMEN

The distinctive morphology of dendritic mesoporous silica nanoparticles (DMSN) has recently attracted considerable attention in scientific community. However, synthesis of DMSN with well-defined structure and uniform size for ultrafast extraction of trace herbicide residues from environmental and food samples remains to be a compelling challenge. In this study, sulfhydryl functionalized dendritic mesoporous silica (SH-DMSN) was synthesized and the SH-DMSN showcases monodisperse microspheres with flower shape and precisely tailored and controllable pore sizes. This distinctive structural configuration accelerates mass transfer within the silica layer, resulting in heightened adsorption efficiencies. Furthermore, the particle sizes (455, 765, and 808) of the adsorbent can be meticulously fine-tuned by introducing distinct templates. Specifically, when the particle size is 765 nm, the optimized SH-DMSN exhibits a substantial specific surface area (691.32 m²/g), outstanding adsorption efficiencies (>90 %), remarkably swift adsorption and desorption kinetics (2 min and 3 min, respectively), and exceptional stability. The superior adsorption capabilities of this novel adsorbent, ranging from 481.65 to 1021.7 µg/g for organochlorine herbicides containing amide groups, can be attributed to the interplay of S-π interactions, halogen bonding, and electrostatic attraction interaction. These interactions involve the lone pair electrons of sulfhydryl and silanol groups with the π-electrons, halogen atoms and amide groups in herbicide molecules. This study not only offers a new perspective on advancing the practical utilization of dendritic mesoporous silica but also provides a pragmatic strategy for the separation and analysis of herbicides in diverse sample matrices.


Asunto(s)
Herbicidas , Nanosferas , Nanosferas/química , Dióxido de Silicio/química , Halógenos , Porosidad
3.
Front Neurol ; 14: 1241549, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37731857

RESUMEN

Background: Reversible splenial lesion syndrome (RESLES) is a new clinico-radiological syndrome. We retrospectively analyzed the clinical features of 130 children with RESLES in China, which is the largest case series available in the literature. Methods: The clinical data of children diagnosed as RESLES in Jiangxi Provincial Children's Hospital between 2017 and 2023 were retrospectively analyzed. The 130 cases were divided into two groups: ≤ 3 years old group (group A) (n = 83) and > 3 years old group (group B) (n = 47). The chi-squared test or Fisher's test was used to evaluate the data. Results: The vast majority of patients (127/130 cases, 97.7%) had prodromal symptoms of infection. Preceding infections of the gastrointestinal tract were statistically more significant in group A (60/83, 72.3%) than in group B (11/47, 23.4%) (P < 0.05). Preceding infections of the respiratory tract were statistically more significant in group B (33/47, 70.2%) than in group A (17/83, 20.5%) (P < 0.05). Seizures were statistically more significant in group A (82/83, 98.8%) than in group B (24/47,51.1%) (P < 0.05). The disturbance of consciousness and headache/dizziness were statistically more significant in group B (27/47, 57.4%; 37/47, 78.7%) than in group A (3/83, 3.6%; 1/83, 1.2%), respectively (P < 0.05). Convulsions with mild gastroenteritis (CwG) were statistically more significant in group A (50/83, 60.2%) than in group B (8/47, 17.0%) (P < 0.05). However, encephalitis/encephalopathy was statistically more significant in group B (20/47, 42.6%) than in group A (10/83, 12.0%) (P < 0.05). MRI showed cytotoxic edema in typical locations (RESLES type-1 limited to the splenium of the corpus callosum and RESLES type-2 spread to the entire corpus callosum, adjacent white matter, or both). There was full recovery of the lesions of MRI in all cases from 3 days to 50 days after the initial examinations. All the children showed normal neurodevelopment. Conclusion: Infection was the most common cause of RESLES. Infections of the gastrointestinal tract are common in ≤ 3 years old children, while infections of the respiratory tract are common in >3 years old children. Younger patients are more likely to develop convulsions, and older children were more likely to have symptoms with disturbance of consciousness and headache/dizziness. RESLES has characteristic MRI manifestations and a good prognosis.

4.
J Sep Sci ; 46(14): e2300112, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-37132076

RESUMEN

In this work, amphiphilic polymers synthesized from carboxylated carbon nanotubes stabilized high internal phase emulsions are demonstrated to be capable of direct extracting zearalenone and zearalanone in samples consisting of an oil-water emulsion system. Under optimal conditions, the maximum adsorption capacities for zearalenone and zearalanone are 17.27 and 13.26 mg/g. The adsorption is mainly attributed to π-π interaction, hydrophobic interaction, and hydrogen-bonding interaction for zearalenone and zearalanone. The adsorption isotherms reveal that the adsorption of zearalenone and zearalanone on amphiphilic polymers synthesized from carboxylated carbon nanotubes stabilized high internal phase emulsions follows Freundlich model with multilayer and heterogeneous adsorption due to the presence of multiple kinds of adsorption sites. The relative recoveries of the spiked zearalenone and zearalanone in corn juice samples range from 85% to 93% with relative standard deviations lower than 3.52%. The results manifest the high efficiency of amphiphilic polymers synthesized from carboxylated carbon nanotubes stabilized high internal phase emulsions for the adsorption and separation of analytes in the oil-water emulsion system. This study provides a new perspective on adsorbent engineering for the adsorption application in heterogeneous media.


Asunto(s)
Nanotubos de Carbono , Zearalenona , Zearalenona/análisis , Nanotubos de Carbono/química , Zea mays , Emulsiones , Espectrometría de Masas en Tándem/métodos , Cromatografía Líquida de Alta Presión/métodos , Cromatografía Liquida , Extracción en Fase Sólida/métodos , Agua
5.
Anal Chim Acta ; 1227: 340270, 2022 Sep 22.
Artículo en Inglés | MEDLINE | ID: mdl-36089309

RESUMEN

In this work, a porous capillary monolithic column was simply prepared by in situ thiol-alkyne click polymerization of dipentaerythritol hexakis (3-mercaptopropionate) and dimethyl dipropargylmalonate in fused-silica capillary. The capillary monolithic column shows excellent permeability, high porosity, and thoiether-rich groups, thereby, a high-efficient capacity for trace estrogens from complex samples are obtained via electron-donor-acceptor π-π interaction and hydrophobic interaction. The highest adsorption efficiency for estrogens is achieved at pH = 7.0 with a flow rate of 0.200 mL min-1. The superior adsorption capacities of the as-prepared capillary column for eight estrogens range from 0.092 mg m-1 to 0.31 mg m-1. A simple, reliable, and sensitive method for the determination of eight estrogens in biological and environmental samples is developed using the monolithic polymer as in-tube solid-phase microextraction coupled with ultrahigh performance liquid chromatography-tandem mass spectrometry (SPME-UPLC-MS/MS), and the total instrumental analysis time for the SPME-UPLC-MS/MS procedures was about 60 min per sample. The developed method shows a wide linear range (0.0500-5.00 µg L-1), and low limits of detection (5.34-9.63 ng L-1) for estrogens. The concentrations of estrogens in serum, urine, and pond water samples are found to be no more than 3.69, 0.741, and 1.04 µg L-1, respectively, and the satisfying recoveries for the eight estrogens range from 80.3% to 113% with relative standard deviations (n = 5) of 1.5-9.4%. The established method is highly potential for extraction and analysis of ultratrace target estrogens in complex matrices, such as biological and environmental samples.


Asunto(s)
Estrógenos , Espectrometría de Masas en Tándem , Cromatografía Líquida de Alta Presión/métodos , Cromatografía Liquida/métodos , Estrógenos/análisis , Porosidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA