Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Ann Vasc Surg ; 106: 196-204, 2024 May 27.
Artículo en Inglés | MEDLINE | ID: mdl-38810725

RESUMEN

BACKGROUND: Endovascular aortic repair (EVAR) has become the standard of care for patients with infrarenal aortic aneurysms over the last 2 decades. Endograft technology and treatment of complications like endoleaks, graft migration, or graft occlusion developed over time. However, sometimes open surgical conversion maybe required. Our aim was to analyze the indications, the technical aspects and outcomes in patients who underwent open conversion after EVAR with different types and generations of endografts. METHODS: This retrospective single-center study reviewed all patients who underwent EVAR from 2004 to 2020. Open surgical conversions >1 month post EVAR were identified. Conversions for graft infection were excluded. Indications for conversion and operative technique were analyzed. Primary endpoint of the study was 30-day mortality. Secondary endpoints were re-interventions and follow-up mortality. RESULTS: During 2004 and 2020, 443 consecutive EVARs were performed, and 28 patients required open surgical conversion, with an additional 3 referred from other hospitals (N = 31). The median age was 75 (range 58-93); 94% were male. Conversion was performed after a median time of 55 months (range 16-209). Twenty patients underwent elective and 11 emergency conversion. Indications for open conversion were graft migration, respectively, disease progression with endoleak type Ia and/or Ib in 52% (16/31) and sac expansion due to endoleak type II in 26% (8/31). Of the 31 patients, 17 (55%) had at least one previous endovascular re-intervention. All patients met the device-specific instructions for use for each implanted endograft. In-hospital intervention rate was 16% (5/31). Thirty-day mortality rate was 3% (1/31) with one patient died due to multiorgan failure after rupture with complete endograft replacement. Five patients (16%) died during follow-up. Mid-term follow-up was 47.5 months (range 24-203) with estimated cumulative survival rates of 97%, 89%, and 84%, at 1, 3, and 5 years, respectively. CONCLUSIONS: Late open conversion remains a valuable treatment option and can be performed safely in elective and emergency setting with a low early mortality. Lifelong surveillance and prompt intervention when necessary are essential in ensuring optimal outcomes after EVAR and preventing the need for emergent conversions.

2.
Ann Vasc Surg ; 74: 229-236, 2021 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-33549779

RESUMEN

BACKGROUND: To compare the perioperative outcome of patients treated with elective or urgent fenestrated and branched stent grafting (fbEVAR) for pararenal (pAAA) and thoracoabdominal aortic aneurysm (TAAA) after previous open with previous endovascular abdominal aortic repair. METHODS: Single center retrospective analysis of all patients undergoing fbEVAR after previous open (post-open fbEVAR group) or endovascular abdominal aortic repair (post-endo fbEVAR group) between January 2015 and December 2017. Primary outcomes were technical success and in-hospital all-cause mortality. RESULTS: We identified 42 patients undergoing fbEVAR after previous open or endovascular abdominal aortic repair during this period. Twenty-one patients (post-open fbEVAR group) had previous open abdominal aortic repair, 13 with a bifurcated and 8 with a tube graft. Of these, 2 patients presented with pAAA and 19 with TAAA. Twenty-one patients (post-endo fbEVAR group) had previous EVAR. Thirteen patients presented with pAAA, 3 of them with additional type Ia endoleak, 2 with stent-graft migration and 2 with previously failed fEVAR. Eight presented with TAAA. Median interval between previous repair and fbEVAR was 84 months (IQR 60-156) for the post-open fbEVAR group and 72 months (IQR 36-96) for the post-endo fbEVAR group (P = 0.746). Eighteen patients (86%) had branched stent grafting in the post-open versus 11 (52%) in the post-endo group (P < 0.01). In 2 patients in the post-open group, 3 renal arteries were not catheterized due to severe ostial stenosis, resulting in technical success of 91% in the post-open and 100% in the post-endo fbEVAR group. Four patients (19%) in the post-open fbEVAR group died in hospital, 2 due to cerebral hemorrhage and 2 due to pneumonia, and none in the post-endo fbEVAR group (P = 0.101). There were 5 nonstent-graft-related reinterventions, 2 (10%) in the post-open fbEVAR group and 3 (14%) in the post-endo fbEVAR group (P = 0.844). After 12 months there were 4 events in the post-endo fbEVAR group: one renal artery stent occluded, one renal artery stent required relining because of disconnection and 2 type II endoleaks were embolized with coils. There were no reinterventions in the post-open fbEVAR group during 12 months. CONCLUSIONS: Fenestrated and branched repair after previous open or endovascular abdominal aortic repair appears safe with high technical success rate. There is no difference in the technical success and in-hospital all-cause mortality rates between fbEVAR after previous open or endovascular abdominal aortic repair.


Asunto(s)
Aneurisma de la Aorta Abdominal/cirugía , Aneurisma de la Aorta Torácica/cirugía , Implantación de Prótesis Vascular/instrumentación , Prótesis Vascular , Procedimientos Endovasculares/instrumentación , Stents , Anciano , Anciano de 80 o más Años , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/mortalidad , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Aneurisma de la Aorta Torácica/mortalidad , Implantación de Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/mortalidad , Procedimientos Endovasculares/efectos adversos , Procedimientos Endovasculares/mortalidad , Femenino , Mortalidad Hospitalaria , Humanos , Masculino , Complicaciones Posoperatorias/mortalidad , Complicaciones Posoperatorias/terapia , Reoperación , Estudios Retrospectivos , Factores de Tiempo , Resultado del Tratamiento
3.
Zentralbl Chir ; 143(5): 510-515, 2018 Oct.
Artículo en Alemán | MEDLINE | ID: mdl-30357791

RESUMEN

Aneurysm rupture is a potentially lethal complication. Open and endovascular treatment show similar mortality rates in high volume centres (15 - 20%). Individual patient management is more important than the choice between open or endovascular repair. Permissive hypotension with fluid restriction and aneurysm morphology suitable for endovascular treatment have a positive impact on mortality after either method of repair. Coronary artery disease, chronic renal impairment, and hypovolaemic shock raise mortality. Reintervention rates after endovascular repair are high and mandate lifelong follow-up.


Asunto(s)
Aneurisma de la Aorta Abdominal , Rotura de la Aorta , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Humanos , Complicaciones Posoperatorias , Resultado del Tratamiento
4.
J Vasc Access ; 16 Suppl 9: S121-5, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-25751566

RESUMEN

Rapidly growing technical developments and working time constraints call for changes in trainee formation. In reality, trainees spend fewer hours in the hospital and face more difficulties in acquiring the required qualifications in order to work independently as a specialist. Simulation-based training is a potential solution. It offers the possibility to learn basic technical skills, repeatedly perform key steps in procedures and simulate challenging scenarios in team training. Patients are not at risk and learning curves can be shortened. Advanced learners are able to train rare complications. Senior faculty member's presence is key to assess and debrief effective simulation training. In the field of vascular access surgery, simulation models are available for open as well as endovascular procedures. In this narrative review, we describe the theory of simulation, present simulation models in vascular (access) surgery, discuss the possible benefits for patient safety and the difficulties of implementing simulation in training.


Asunto(s)
Derivación Arteriovenosa Quirúrgica/educación , Simulación por Computador , Instrucción por Computador/métodos , Educación de Postgrado en Medicina/métodos , Internado y Residencia , Enseñanza/métodos , Derivación Arteriovenosa Quirúrgica/efectos adversos , Competencia Clínica , Curriculum , Humanos , Modelos Anatómicos , Modelos Cardiovasculares , Seguridad del Paciente
5.
J Vasc Surg Venous Lymphat Disord ; 3(4): 442-445, 2015 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-26992623

RESUMEN

Venous angioplasty with stenting of iliac veins is an important treatment option for patients suffering from post-thrombotic syndrome due to chronic venous obstruction. Interventional treatment of a chronically occluded vena cava, however, is challenging and often associated with failure. We describe a case of a chronic total occlusion of the entire inferior vena cava that was successfully recanalized using bidirectional wire access and a balloon puncture by a re-entry catheter to establish patency of the inferior vena cava.


Asunto(s)
Procedimientos Endovasculares , Stents , Síndrome de la Vena Cava Superior/terapia , Vena Cava Inferior/patología , Angioplastia de Balón , Constricción Patológica , Humanos , Vena Ilíaca , Masculino , Persona de Mediana Edad , Punciones , Resultado del Tratamiento , Enfermedades Vasculares
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...