Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 44
Filtrar
1.
J Med Chem ; 2024 Sep 21.
Artículo en Inglés | MEDLINE | ID: mdl-39305244

RESUMEN

The fluorescence high-throughput screening method is of importance for new antioxidant drug candidate discovery for the treatment of serious hepatorenal syndrome, which displayed an obvious upregulated peroxynitrite level. However, most of the current ONOO- probes possessed incomplete fluorescence quenching efficiency, which can result in non-negligible probe inherent fluorescence. Hence, we utilized the probe conjugated structure disruption strategy to construct hydrogenation phosphorus-substituted rhodamine (H-PRh) with "zero" probe inherent fluorescence character. Based on the precursor, a series of natural products were screened for identifying antioxidant drug candidates. Luteolin was screened out by activating the Sirt1-Nrf2-HO-1 signaling pathway to regulate the accumulation of ONOO- in the hepatorenal syndrome. Overall, the "zero" probe inherent fluorescence ONOO- sensor constructed here applies for a promising and versatile toolbox for illuminating the ONOO--related pathological process in the hepatorenal syndrome. Besides, this strategy of constructing highly sensitive sensors could serve as a valuable reference for further fluorescent probes.

2.
Front Oncol ; 14: 1428498, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39144828

RESUMEN

Introduction: 68Ga labeled DOTA-Ibandronate (68Ga-DOTA-IBA) positron emission tomography/computed tomography (PET/CT), is a novel bone-targeting imaging tracer and promising diagnostic method for bone metastases detection. Therefore, this study aimed to compare 68Ga-DOTA-IBA PET/CT to the 99mTc-MDP whole-body bone scan (WBBS) for detecting bone metastases in breast cancer (BC). Materials and methods: In this prospective study, 45 women with BC underwent imaging via 68Ga-DOTA-IBA PET/CT and 99mTc-MDP WBBS. Clinical and demographic information as well as BC imaging features were recorded. The two methods were compared in terms of their detection rate for bone metastases and the number of lesions. Results: The 45 women were aged 53.5 ± 11.0 years. The bone metastases detection rate with 68Ga-DOTA-IBA PET/CT was 100% (45/45) and with 99mTc-MDP WBBS was 95.6% (43/45). A total of 546 bone metastases lesions were detected. The lesion detection rate using 68Ga-DOTA-IBA PET/CT was 100% (546/546) and using 99mTc-MDP WBBS was 67.8% (370/546). More lesions were found at each site via 68Ga-DOTA-IBA than via 99mTc-MDP WBBS. Conclusions: 68Ga-DOTA-IBA PET/CT is a more sensitive method than 99mTc-MDP WBBS for assessing bone metastases in BC and may therefore represent a useful imaging technique for bone metastases, while offering a visual basis for 177Lu-DOTA-IBA diagnosis and therapy response assessments for BC. Further validation using a broader study cohort is warranted to confirm these findings. Clinical trial registration: https://www.chictr.org.cn/showproj.html?proj=170163, identifier ChiCTR2200064487.

3.
Clin Nucl Med ; 2024 Aug 28.
Artículo en Inglés | MEDLINE | ID: mdl-39192499

RESUMEN

ABSTRACT: 68Ga-labeled DOTA-ibandronic acid (68Ga-DOTA-IBA) is a novel PET agent developed for bone tumors. In addition, 68Ga-DOTA-IBA uptake in nonosseous findings has also been reported. Herein, we present a case of 68Ga-DOTA-IBA uptake in primary prostate adenocarcinoma.

4.
Clin Nucl Med ; 2024 Aug 06.
Artículo en Inglés | MEDLINE | ID: mdl-39104035

RESUMEN

ABSTRACT: A 29-year-old man with Ewing sarcoma in the right ankle underwent 68Ga-DOTA-IBA PET/CT and 18F-FDG PET/CT, both of which showed high radiotracer activity for the primary tumor. Interestingly, bone metastases were detected early using 68Ga-DOTA-IBA PET/CT for the sixth thoracic vertebrae and with 18F-FDG PET/CT for the bilateral humerus. Higher uptake of 68Ga-DOTA-IBA was found in both primary and metastatic sites of Ewing sarcoma. 177Lu-DOTA-IBA may be one of the possible therapies for metastatic or recurrent Ewing sarcoma.

5.
Front Oncol ; 14: 1344643, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38974238

RESUMEN

Purpose: This study aimed to analyze articles on the diagnosis and treatment of bone and soft tissue sarcoma using positron emission tomography (PET)/computed tomography (CT) published in the last 13 years. The objective was to conduct a bibliometric analysis and identify the research hotspots and emerging trends. Methods: Web of Science was used to search for articles on PET/CT diagnosis and treatment of bone and soft tissue sarcoma published from January 2010 to June 2023. CiteSpace was utilized to import data for bibliometric analysis. Results: In total, 425 relevant publications were identified. Publications have maintained a relatively stable growth rate for the past 13 years. The USA has the highest number of published articles (139) and the highest centrality (0.35). The UDICE-French Research Universities group is the most influential institution. BYUN BH is a prominent contributor to this field. The Journal of Clinical Oncology has the highest impact factor in the field. Conclusion: The clinical application of PET/CT is currently a research hotspot. Upcoming areas of study concentrate on the merging of PET/CT with advanced machine learning and/or alternative imaging methods, novel imaging substances, and the fusion of diagnosis and therapy. The use of PET/CT has progressively become a crucial element in the identification and management of sarcomas. To confirm its efficacy, there is a need for extensive, multicenter, prospective studies.

6.
Front Oncol ; 14: 1413771, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39011487

RESUMEN

Purpose: The 68Ga/177Lu-FAP-2286 is a newly developed tumor imaging agent that shows potential for visualizing and treating tumor stroma. The objective of this research was to evaluate the effectiveness of 68Ga-FAP-2286 PET/CT and 18F-FDG PET/CT in diagnosing advanced lung cancer. Methods: In this prospective study, patients with lung cancer who underwent 68Ga-FAP-2286 and 18F-FDG PET/CT examinations between September 2022 and June 2023 were analyzed. Lesion uptake was converted to SUVmax. A paired T-test was used to compare the SUVmax, and the number of positive lesions detected by the two methods was recorded. Results: In total, 31 participants (median age: 56 years) were assessed. The uptake of 68Ga-FAP-2286 was significantly higher than that of 18F-FDG in primary lesions (9.90 ± 5.61 vs. 6.09 ± 2.84, respectively, P < 0.001), lymph nodes (7.95 ± 2.75 vs. 5.55 ± 1.59, respectively, P=0.01), and bone metastases (7.74 ± 3.72 vs. 5.66 ± 3.55, respectively, P=0.04). Furthermore, the detection sensitivity of lymph nodes using 68Ga-FAP-2286 PET/CT was superior to that with 18F-FDG PET/CT [100% (137/137) vs. 78.8% (108/137), respectively], as well as for bone metastases [100% (384/384) vs. 68.5% (263/384), respectively]. However, the detection sensitivity for primary tumors using both modalities was comparable [100% (13/13) for both]. Conclusion: Compared to 18F-FDG PET/CT, 68Ga-FAP-2286 PET/CT demonstrated better lesion detection capabilities for lung cancer, particularly in lymph nodes and bone metastases, providing compelling imaging evidence for the efficacy of 177Lu-FAP-2286 treatment.

7.
Anal Chem ; 96(29): 12074-12083, 2024 07 23.
Artículo en Inglés | MEDLINE | ID: mdl-38981066

RESUMEN

Activatable probes with a higher signal-to-background ratio and accuracy are essential for monitoring liver cancer as well as intraoperative fluorescence navigation. However, the presence of only one biomarker is usually not sufficient to meet the high requirement of a signal-to-background ratio in cancer surveillance, leading to the risk of misdiagnosis. In this work, a dual-locked activation response probe, Si-NTR-LAP, for nitroreductase and leucine aminopeptidase was reported. This dual-locked probe provides better tumor recognition and a higher signal-to-noise ratio than that of single-locked probes (Si-LAP and Si-NTR). In both the subcutaneous tumor model and the more complex orthotopic hepatocellular carcinoma model, the probe was able to identify tumor tissue with high specificity and accurately differentiate the boundaries between tumor tissue and normal tissue. Therefore, the dual-locked probe may provide a new and practical strategy for applying to real patient tumor tissue samples.


Asunto(s)
Leucil Aminopeptidasa , Neoplasias Hepáticas , Nitrorreductasas , Neoplasias Hepáticas/diagnóstico , Neoplasias Hepáticas/metabolismo , Humanos , Animales , Leucil Aminopeptidasa/metabolismo , Leucil Aminopeptidasa/análisis , Nitrorreductasas/metabolismo , Nitrorreductasas/análisis , Carcinoma Hepatocelular/diagnóstico , Carcinoma Hepatocelular/metabolismo , Ratones , Colorantes Fluorescentes/química , Imagen Óptica
10.
Adv Mater ; 36(31): e2404828, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38781580

RESUMEN

High-performance fluorescent probes stand as indispensable tools in fluorescence-guided imaging, and are crucial for precise delineation of focal tissue while minimizing unnecessary removal of healthy tissue. Herein, machine-learning-assisted strategy to investigate the current available xanthene dyes is first proposed, and a quantitative prediction model to guide the rational synthesis of novel fluorescent molecules with the desired pH responsivity is constructed. Two novel Si─rhodamine derivatives are successfully achieved and the cathepsin/pH sequentially activated probe Si─rhodamine─cathepsin-pH (SiR─CTS-pH) is constructed. The results reveal that SiR─CTS-pH exhibits higher signal-to-noise ratio of fluorescence imaging, compared to single pH or cathepsin-activated probe. Moreover, SiR─CTS-pH shows strong differentiation abilities for tumor cells and tissues and accurately discriminates the complex hepatocellular carcinoma tissues from normal ones, indicating its significant application potential in clinical practice. Therefore, the continuous development of xanthene dyes and the rational design of superior fluorescent molecules through machine-learning-assisted model broaden the path and provide more advanced methods to researchers.


Asunto(s)
Catepsinas , Colorantes Fluorescentes , Aprendizaje Automático , Rodaminas , Rodaminas/química , Colorantes Fluorescentes/química , Humanos , Concentración de Iones de Hidrógeno , Catepsinas/metabolismo , Silicio/química , Imagen Óptica/métodos , Carcinoma Hepatocelular/diagnóstico por imagen , Neoplasias Hepáticas/diagnóstico por imagen
11.
Front Bioeng Biotechnol ; 12: 1353901, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38720880

RESUMEN

The separate vertical wire (SVW) technique and the improved candy box (CB) technique have been proposed for treating inferior pole patellar fractures. However, there is still a lack of clear explanation regarding the location of the wire passing through the patella. Five models of SVW techniques were established in different positions. Finite element analysis was then conducted to determine the optimal bone tunnel position for the SVW technique. Based on these findings, six groups of finite element models were created for CB techniques. The maximum displacement and stress on both the patella and steel wire were compared among these groups under 100-N, 200-N, 300-N, 400-N, and 500-N force loads. The results indicated that, in the SVW technique, the steel wire group near the fracture end of the longitudinal bone tunnel showed minimal displacement and stress on the patella when subjected to different forces. On the other hand, in the CB technique, both the patella and wire experienced minimal stress when a transverse bone tunnel wire was placed near the upper posterior aspect of patella. In conclusion, the SVW technique may require the bone tunnel wire to be positioned near the fractured end of the lower pole of the patella. On the other hand, in CB technique, the transverse bone tunnel wire passing through the patella may be close to its upper posterior aspect. However, further validation is necessary through comprehensive finite element analysis and additional biomechanical experiments.

12.
Sci Rep ; 14(1): 7111, 2024 03 26.
Artículo en Inglés | MEDLINE | ID: mdl-38531907

RESUMEN

This study aims to measure anatomical data of the capitate bone, develop an external fixator for treating late-stage osteonecrosis of lunate through Ilizarov technique, and evaluate its biomechanical performance. We selected eight wrist joint specimens to measure various parameters of the capitate bone, including its length, the distance from the junction of capitate head and body to the proximal end, as well as the width of its proximal head and distal body. Additionally, we measured these same indicators in 107 patients who had undergone wrist X-ray examination. Based on our measurements, we categorized the capitate bone into two groups and designed two types of capitate bone Ilizarov external fixator (CIEF) for it. Then, we compared it with the orthofix external fixator (OEF) through dynamic fatigue biomechanical experiments and pull-out resistance experiments. The results of the measurement revealed two categories of general patterns in the capitate bone. The first type maintains a consistent longitudinal axis between the proximal and distal ends. The second type is characterized by its proximal end being close to the radial side and its distal end being close to the ulnar side. In the dynamic tensile fatigue test, CIEF-A and CIEF-B had smaller maximum displacement values compared to the OEF (P < 0.05). In the anti-pull-out experiment, both CIEF-A and CIEF-B exhibited higher maximum pull-out force than the OEF (P < 0.05). CIFE is a treatment for advanced osteonecrosis of the lunate bone. It is specifically designed to align with the anatomical characteristics of the capitate bone, providing excellent biomechanical properties and a simple clinical procedure. However, additional clinical experiments are needed to confirm its effectiveness in the future.


Asunto(s)
Hueso Grande del Carpo , Hueso Semilunar , Osteonecrosis , Humanos , Osteonecrosis/cirugía , Articulación de la Muñeca/cirugía , Radio (Anatomía)
13.
Front Bioeng Biotechnol ; 12: 1340482, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38515618

RESUMEN

Objective: Few reports exist on the treatment of transverse patellar fractures (TPFs) using absorbable cannulated screws and high-strength sutures, and most screws and sutures lack good biomechanics and clinical trials. Therefore, this study aimed to demonstrate the biomechanical stability and clinical efficacy of tension-band high-strength sutures combined with absorbable cannulated screws (TBSAS) in treating TPFs (AO/OTA 34 C1). Methods: Finite element models of five internal fixation schemes were established: tension-band wire with K-wire (TBW), TBW with cerclage wire (TBWC), TBW with headless pressure screws (TBWHS), TBW with full-thread screws (TBWFS), and TBSAS. We comprehensively compared the biomechanical characteristics of the TBSAS treatment scheme during knee flexion and extension. Forty-one patients with TPFs in our hospital between January 2020 and August 2022 were retrospectively enrolled and divided into the TBSAS (n = 22) and TBWC (n = 19) groups. Clinical and follow-up outcomes, including operative time, visual analog scale (VAS) pain score, postoperative complications, Bostman score, and final knee range of motion, were compared between both groups. Results: Finite element analysis (FEA) showed that TBWHS and TBWFS achieved the minimum mean fracture interface relative displacement during knee flexion (45°, 0-500 N bending load) and full extension (0°, 0-500 N axial load). There was no significant difference between TBSAS (0.136 mm) and TBWC (0.146 mm) during knee flexion (500 N); however, TBSAS displacement was smaller (0.075 mm) during full extension (500 N). Furthermore, the stress results for the internal fixation and the patella were generally lower when using TBSAS. Retrospective clinical studies showed that the TBSAS group had a shorter operative time, lower VAS pain score at 1 and 2 months postoperatively, better Bostman knee function score at 3 and 9 months postoperatively, and better final knee joint motion than the TBWC group (all p < 0.05). There were five cases (26.3%) of internal fixation stimulation complications in the TBWC group. Conclusion: TBSAS demonstrated excellent safety and effectiveness in treating TPFs. It is sufficient to meet the needs of TPF fixation and early functional exercise and effectively reduces metal internal fixation-induced complications and secondary surgery-induced trauma.

14.
Clin Nucl Med ; 49(6): 574-575, 2024 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-38537211

RESUMEN

ABSTRACT: A 77-year-old woman with recently diagnosed breast cancer underwent 68 Ga-labeled DOTA-ibandronic acid ( 68 Ga-DOTA-IBA) PET/CT scan for the evaluation of bone metastases. The examination revealed increased tracer uptake, indicating that the cervical vertebrae presented osteoblastic metastasis. Interestingly, the breast cancer also showed enhanced activity of 68 Ga-DOTA-IBA.


Asunto(s)
Neoplasias de la Mama , Tomografía Computarizada por Tomografía de Emisión de Positrones , Humanos , Femenino , Anciano , Neoplasias de la Mama/diagnóstico por imagen , Neoplasias de la Mama/metabolismo , Compuestos Organometálicos/farmacocinética , Transporte Biológico , Compuestos Heterocíclicos con 1 Anillo , Radioisótopos de Galio , Difosfonatos/farmacocinética
15.
Int J Biochem Cell Biol ; 166: 106494, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37956954

RESUMEN

Microparticles (MPs) are a heterogeneous subpopulation of extracellular vesicles that originate from the plasma membranes of cells. There is increasing evidence that tumor-derived MPs (T-MPs) play a significant role in tumor progression and immune response in cancer. In our study, we found an increased secretion of MPs in osteosarcoma tissues obtained from metastatic patients. These T-MPs promoted polarization of M2-like macrophages and stimulated the migration and chemoresistance of osteosarcoma cells. Mechanistically, T-MPs promoted macrophage polarization to an M2-like phenotype through TBK1-STAT6 signaling. Consequently, these M2-like macrophages mediated osteosarcoma cell migration via CCL18/STAT3 signaling. Blockade of STAT3 signaling pathway improved the outcome of chemotherapy in LM8-bearing osteosarcoma mice model. Thus, our study reveals how tumor cells regulate macrophage polarization by releasing MPs and provides new insights into clinical osteosarcoma therapy.


Asunto(s)
Neoplasias Óseas , Osteosarcoma , Animales , Ratones , Humanos , Macrófagos/metabolismo , Osteosarcoma/patología , Transducción de Señal , Fenotipo , Neoplasias Óseas/patología , Línea Celular Tumoral
16.
JACS Au ; 3(12): 3462-3472, 2023 Dec 25.
Artículo en Inglés | MEDLINE | ID: mdl-38155649

RESUMEN

Enriching the palette of high-performance fluorescent dyes is vital to support the frontier of biomedical imaging. Although various rhodamine skeletons remain the premier type of small-molecule fluorophores due to the apparent high brightness and flexible modifiability, they still suffer from the inherent defect of small Stokes shift due to the nonideal fluorescence imaging signal-to-background ratio. Especially, the rising class of fluorescent dyes, sulfone-substituted xanthone, exhibits great potential, but low chemical stability is also pointed out as the problem. Molecular engineering of sulfone-xanthone to obtain a large Stokes shift and high stability is highly desired, but it is still scarce. Herein, we present the combination modification method for optimizing the performance of sulfone-xanthone. These redesigned fluorescent skeletons owned greatly improved stability and Stokes shift compared with the parent sulfone-rhodamine. To the proof of bioimaging capacity, annexin protein-targeted peptide LS301 was introduced to the most promising dyes, J-S-ARh, to form the tumor-targeted fluorescent probe, J-S-LS301. The resulting probe, J-S-LS301, can be an outstanding fluorescence tool for the orthotopic transplantation tumor model of hepatocellular carcinoma imaging and on-site pathological analysis. In summary, the combination method could serve as a basis for rational optimization of sulfone-xanthone. Overall, the chemistry reported here broadens the scope of accessible sulfone-xanthone functionality and, in turn, enables to facilitate the translation of biomedical research toward the clinical domain.

17.
BMC Musculoskelet Disord ; 24(1): 835, 2023 Oct 23.
Artículo en Inglés | MEDLINE | ID: mdl-37872511

RESUMEN

BACKGROUND: Maintaining effective reduction and firm fixation in inferior pole patellar fractures is a highly challenging task. There are various treatment methods available; although tension-band wiring combined with cerclage wiring (TBWC) is the mainstream approach, its effectiveness is limited. Herein, we propose and evaluate a new technique called candy box (CB), based on separate vertical wiring (SVW), for the treatment of inferior pole patellar fractures. Specifically, we provide biomechanical evidence for its clinical application. METHODS: Five fixation models were built: SVW combined with cerclage wiring (SVWC); TBWC; modified SVW with the middle (MSVW-A) or upper (MSVW-B) 1/3 of the steel wire reserved, and CB. A finite element analysis was performed to compare the displacement and stress under 100-N, 200-N, 300-N, 400-N and 500-N force loads. Three-dimensional printing technology was utilized to create fracture models, and the average displacement of each model group was compared under a 500-N force. RESULTS: The results of the finite element analysis indicate that CB technology exhibits significantly lower maximum displacement, bone stress, and wire stress compared to that with other technologies under different loads. Additionally, in biomechanical experiments, the average force displacement in the CB group was significantly smaller than that with other methods under a 500-N force (P < 0.05). CONCLUSIONS: CB technology has the potential to overcome the limitations of current techniques due to its superior biomechanical characteristics. By incorporating early functional exercise and ensuring strong internal fixation, patient prognosis could be enhanced. However, further clinical trials are needed to fully evaluate the therapeutic effects of CB technology.


Asunto(s)
Fracturas Óseas , Traumatismos de la Rodilla , Humanos , Análisis de Elementos Finitos , Rótula/diagnóstico por imagen , Rótula/cirugía , Fracturas Óseas/diagnóstico por imagen , Fracturas Óseas/cirugía , Fijación Interna de Fracturas/métodos , Hilos Ortopédicos , Fenómenos Biomecánicos
18.
Medicine (Baltimore) ; 102(39): e35302, 2023 Sep 29.
Artículo en Inglés | MEDLINE | ID: mdl-37773872

RESUMEN

There are multiple surgical options for treatment of chronic Achilles tendon (AT) rupture according to the classifications and length of defect. However, no gold standard method has been confirmed, and there is no clear evidence to support the superiority of 1 procedure over others. This study aimed to evaluate the long-term clinical outcome of flexor hallucis longus tendon (FHL) transfer for chronic AT rupture with large defect. Clinical data of patients treated with FHL transfer due to chronic AT rupture between January 2009 and October 2019 were reviewed retrospectively. All cases were presented with AT rupture for more than 4 weeks after injury. The gap between ruptured ends was > 5 cm after debridement in all patients. The harvest of FHL was performed through a single incision in accordance with AT rupture debridement in all cases. Clinical outcomes were assessed with AOFAS ankle-hindfoot scale, Achilles tendon total rupture score and AOFAS hallux metatarsophalangeal-interphalangeal scale. Twenty-eight patients were followed successfully for 62.6 ±â€…22.2 months. According to the complete datasets obtained from 28 patients, none of the tendons re-ruptured. The AOFAS ankle-hindfoot scale and Achilles tendon total rupture score at last follow-up visit was 90.4 ±â€…5.7 and 89.8 ±â€…5.3 respectively, which revealed statistically significant improvement from the preoperative score of 61.1 ±â€…6.7 and 53.8 ±â€…8.3. The AOFAS hallux metatarsophalangeal-interphalangeal scale at last follow-up visit was 87.5 ±â€…6.1. The FHL transfer through a single incision for chronic AT rupture with large defect is a safe and simple method with low risk of morbidity and complications.


Asunto(s)
Tendón Calcáneo , Traumatismos del Tobillo , Traumatismos de los Tendones , Humanos , Estudios Retrospectivos , Tendón Calcáneo/cirugía , Tendón Calcáneo/lesiones , Transferencia Tendinosa/métodos , Resultado del Tratamiento , Traumatismos de los Tendones/cirugía , Traumatismos de los Tendones/etiología , Rotura/cirugía , Rotura/etiología , Enfermedad Crónica , Traumatismos del Tobillo/etiología
19.
Clin Nucl Med ; 48(9): 818-819, 2023 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-37335257

RESUMEN

ABSTRACT: A 60-year-old man with back pain underwent 99m Tc-MDP to evaluate bone metastases from newly esophageal carcinoma. No bone metastasis was found on the whole-body bone scan. Unexpectedly, subcutaneous metastasis revealed increased 99m Tc-MDP activity.


Asunto(s)
Neoplasias Óseas , Carcinoma , Neoplasias Esofágicas , Masculino , Humanos , Persona de Mediana Edad , Medronato de Tecnecio Tc 99m , Tomografía Computarizada por Rayos X , Neoplasias Óseas/diagnóstico por imagen , Neoplasias Óseas/secundario , Neoplasias Esofágicas/diagnóstico por imagen , Neoplasias Esofágicas/patología , Cintigrafía
20.
ACS Sens ; 8(6): 2359-2367, 2023 06 23.
Artículo en Inglés | MEDLINE | ID: mdl-37265237

RESUMEN

Accurate detection of target analytes and generation of high-fidelity fluorescence signals are particularly critical in life sciences and clinical diagnostics. However, the majority of current NIR-I fluorescent probes are vulnerable to pH effects resulting in signal distortion. In this work, a series of fluorescence-tunable and pH-independent probes are reported by combining optically tunable groups of unsymmetric Si-rhodamines and introducing the methoxy instead of the spiro ring on the benzene ring at position 9. To validate the concept, the leucine aminopeptidase response site was introduced into Si-2,6OMe-NH2 with the best optical properties to synthesize Si-LAP for monitoring the intrahepatic LAP in vivo. Therefore, the design approach may provide a new and practical strategy for designing innovative functional fluorescent probes and generating high-stability and high-fidelity fluorescent signals.


Asunto(s)
Colorantes Fluorescentes , Leucil Aminopeptidasa , Colorantes Fluorescentes/química , Rodaminas/química , Fluorescencia , Concentración de Iones de Hidrógeno
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...