Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 21
Filtrar
1.
Diabetes Res Clin Pract ; 207: 111080, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38145827

RESUMEN

OBJECTIVE: This study aimed at assessing the changes of left atrial (LA) volume and strain function in metabolic syndrome (MS) patients using four-dimensional automatic left atrial quantification (4D-LAQ) and exploring independent correlative factors for LA function. METHODS: A total of 110 MS patients and 70 normal controls were selected and assigned into the MS group and the control group, respectively. Echocardiogram parameters were routinely examined and the thickness of epicardial adipose tissue (EAT) were measured with a parasternal long axis of left ventricle(LV). The LA volume and strain parameters were determined using 4D-LAQ. The independent correlation factors for LA strain parameters in MS patients were investigated through linear regression analysis. RESULTS: Compared with the control group, LA volume parameters were increased in the MS group, LA strain parameters and LA emptying fraction (LAEF) were decreased (all P < 0.05). EAT thickness is associated with LA reservoir longitudinal strain (LASr), conduit longitudinal strain (LAScd), reservoir circumferential strain (LASr-c), and conduit circumferential strain (LAScd-c) (all P < 0.05). LA contraction longitudinal (LASct) and circumferential strain (LASct-c) were not statistically significant. Regression analysis results show that systolic blood pressure (SBP) and triglyceride (TG) are independent correlative factors. Intra-observer and inter-observer repeatability test showed that the LA parameters examined by 4D-LAQ had good agreement. CONCLUSIONS: 4D-LAQ is capable of effectively assessing the LA function in MS patients and providing a useful reference for clinical diagnosis. SBP and TG serve as the independent correlative factors for LA function.


Asunto(s)
Función del Atrio Izquierdo , Síndrome Metabólico , Humanos , Función del Atrio Izquierdo/fisiología , Síndrome Metabólico/diagnóstico por imagen , Ecocardiografía/métodos , Atrios Cardíacos/diagnóstico por imagen , Presión Sanguínea
2.
Sci Rep ; 13(1): 14415, 2023 09 02.
Artículo en Inglés | MEDLINE | ID: mdl-37660205

RESUMEN

Given the inconsistent results on the prognostic significance of epicardial adipose tissue (EAT), the purpose of the present study was to investigate the association of EAT thickness and myocardial work by non-invasive left ventricular pressure-strain loop in people with suspected metabolic syndrome (MS). A total of 194 participants imaged with echocardiography were evaluated. In accordance with the median EAT thickness, MS patients fell into thin EAT group and thick EAT group. Conventional echocardiographic parameters, global longitudinal strain (GLS) and the global myocardial work parameters obtained by pressure-strain loop analysis, comprising the global work index (GWI), global work efficiency (GWE), global constructive work (GCW) and global wasted work (GWW) were compared between the two groups. In comparison with the thin EAT group, thick EAT group achieved significantly higher values in interventricular septal thickness, end-diastolic left ventricular posterior wall thickness, left ventricular mass index and GWW (p < 0.05). while the absolute value of GLS, GWI, GCW, and GWE were notably lower in the thick EAT group (p < 0.001). EAT thickness showed a significant correlation with GWI and GCW (r = - 0.328, p = 0.001; r = - 0.253, p = 0.012), and also independently correlated with GWI and GCW in the multivariate regression analysis (ß = - 0.310, p = 0.001; ß = - 0.199, p = 0.049). EAT thickness is associated with left ventricular myocardial function in subjects with suspected metabolic syndrome, independently of other risk factors. Further studies are supposed to ensure the causal associations and related mechanisms.


Asunto(s)
Síndrome Metabólico , Humanos , Síndrome Metabólico/diagnóstico por imagen , Presión Ventricular , Tejido Adiposo/diagnóstico por imagen , Factores de Riesgo , Diástole
3.
BMC Cardiovasc Disord ; 23(1): 479, 2023 09 27.
Artículo en Inglés | MEDLINE | ID: mdl-37759197

RESUMEN

OBJECTIVE: This study aimed to investigate the value of left ventricular (LV) press-strain loop (PSL) in evaluating global and regional myocardial work (MW) in hypertrophic cardiomyopathy (HCM) patients. METHODS: A total of 30 HCM patients with interventricular septum hypertrophy (HCM group) and 35 healthy subjects (control group) were selected from First Hospital of Qinhuangdao. The general clinical data and conventional ultrasound parameters of two groups were acquired. The MW parameters were analyzed using LV PSL. The regional MW parameters in the HCM group were compared between ventricular septum and the free walls of left ventricle. RESULTS: The epicardial adipose tissue thickness of the HCM group was significantly greater than that of the control group (P < 0.05). Global work efficiency was significantly reduced, while global wasted work was increased in patients with HCM compared with controls (all P < 0.05). The HCM group was compared in the group, to be specific, in the HCM group, the work index, the work efficiency, and the longitudinal strain on the interventricular septum were lower than those on the free wall (all P < 0.05). CONCLUSION: PSL is more effective than LVEF in assessing left ventricular systolic function in HCM and is able to quantify regional myocardial work in the ventricular septum in HCM patients with preserved LVEF, suggesting a novel idea for clinical diagnosis and assessment.


Asunto(s)
Cardiomiopatía Hipertrófica , Humanos , Presión Ventricular , Cardiomiopatía Hipertrófica/complicaciones , Cardiomiopatía Hipertrófica/diagnóstico por imagen , Miocardio , Sístole , Función Ventricular Izquierda
5.
Int Orthop ; 47(2): 351-358, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-36572784

RESUMEN

PURPOSE: This study is to compare the precision and safety of the orthopaedic robot with conventional fluoroscopy for assisted percutaneous sacroiliac joint screw implantation. METHODS: Retrospective analysis was performed on the clinical data of 57 patients with unstable posterior pelvic ring injuries who were admitted and met the criteria between January 2017 and January 2022. All of these patients underwent percutaneous sacroiliac joint screw implantation, and their clinical data were split into two groups based on the surgical technique: a RA group (robot-assisted implantation, 30 patients, 54 screws) and a CF group (conventional fluoroscopic freehand implantation, 27 patients, 42 screws). There were 96 screws placed in total. The durations of the two groups' operations, fluoroscopy examinations, fluoroscopy doses, total number of fluoroscopies, and intra-operative guide pin applications were noted and compared. On post-operative CT scans, the placement of each screw was assessed using the Gertzbein-Robbins classification. Finally, imaging Matta criteria were used to assess the sacroiliac joint fracture reduction. The Majeed functional score was used to assess clinical function. RESULTS: Both groups successfully completed 57 procedures in total. In both groups, there were no consequences from vascular injury, wound infection, or urinary tract infection. Additionally, there were no complications from robotic-induced nerve injury, operating time, fluoroscopic dose, and the frequency of fluoroscopic; the number of percutaneous punctures in the RA group was lower than that of the CF group.There were statistically significant differences between the aforementioned data (P < 0.05). The modified Matta evaluated the effectiveness of fracture reduction. In the RA group, there was no statistically significant difference between the CF group (P > 0.05). According to the modified Gertzbein-Robbins classification criteria, the 54 screws implanted in the RA group were classified as follows: class A (45), class B (5), class C (4), and class D (0); the accuracy rate of the implants was 92.59%. Forty-two screws implanted in the CF group, 30 screws were defined class A, class B (3), class C (7), and class D (2). The accuracy rate of the implants was 78.57%(χ2 = 3.967, P < 0.05). There was a statistically significant difference between the two groups. The Majeed score 30 patients in RA group, one month post-operation, 16 considered exceptional, eight decent, six moderate, and zero bad. Post-operation more than six months,25 recorded exceptional, five decent. By the time,27 patients in CF group,12 exceptional grade, eight decent, six moderate, and one bad,one month post-operation. Post-operation more than six months,22 recorded exceptional, five decent.Both group (P > 0.05). CONCLUSION: "TiRobot" robot-assisted screw implant treatment for unstable posterior pelvic ring injury has a greater success rate than traditional surgery as compared to conventional percutaneous screw implant. It is a precise, secure, and minimally invasive surgical technique that can also be applied to severe pelvic injuries even congenital sacral deformities.


Asunto(s)
Fracturas Óseas , Ortopedia , Robótica , Humanos , Fijación Interna de Fracturas/efectos adversos , Fijación Interna de Fracturas/métodos , Articulación Sacroiliaca/diagnóstico por imagen , Articulación Sacroiliaca/cirugía , Estudios Retrospectivos , Fluoroscopía , Tornillos Óseos , Fracturas Óseas/diagnóstico por imagen , Fracturas Óseas/cirugía
6.
J Stroke Cerebrovasc Dis ; 32(3): 106941, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36586243

RESUMEN

OBJECTIVE: Using shear wave elastography (SWE) and contrast enhanced ultrasound (CEUS)to examine carotid plaques with different echoes, and explore a reliable method to quantify characteristics associated with vulnerable carotid plaques. METHODS: 2D ultrasound, SWE and CEUS were performed on 244 carotid plaques, and the echoes were evaluated according to the Gray-Weale classification scale and gray-scale median (GSM), and the mean Young's modulus (YM) of the plaque was measured and the intraplaque neovascularization was observed to investigate the relationship between carotid plaque types with different echo characteristics, GSM and the values of each parameter of YM and CEUS. The relationship between GSM and YM and CEUS values was investigated. RESULTS: The differences between GSM values (F = 49.742, P < 0.001), with the maximum, mean, and minimum YM values of ultrasound elastography (P < 0.001), and with the number (P < 0.001) and density (P = 0.047) of neovascularization on CEUS were statistically significant for the different echogenic types of plaques, and the lower the echogenicity of the plaque, the lower the GSM values (r = 0.632, P < 0.001), the smaller the YM values (all r > 0, P < 0.001), and the higher the neovascularization number and density values (r < 0, P < 0.001); and there were also statistically significant differences between the above indicators in the vulnerable and stable plaque groups (all P < 0.05). CONCLUSION: GSM, SWE, and CEUS techniques can quantitatively evaluate the vulnerability of different echo carotid plaques in a more comprehensive and objective manner, which may help clinical identification of vulnerable plaques, and provide important reference values for early diagnosis and treatment in clinical practice.


Asunto(s)
Estenosis Carotídea , Diagnóstico por Imagen de Elasticidad , Placa Aterosclerótica , Humanos , Diagnóstico por Imagen de Elasticidad/métodos , Estenosis Carotídea/diagnóstico por imagen , Ultrasonografía/métodos , Arterias Carótidas/diagnóstico por imagen , Neovascularización Patológica/diagnóstico por imagen , Medios de Contraste
7.
Int Orthop ; 47(3): 839-845, 2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-35922521

RESUMEN

PURPOSE: The purpose of this study was to assess the efficiency, safety, and accuracy of cannulated screw fixation using a robot-assisted method compared with a traditional percutaneous freehand method. METHODS: This retrospective clinical study included 18 patients with scaphoid fracture who underwent cannulated screw fixation by robot-assisted technique or traditional percutaneous freehand technique from June 2018 to June 2020. All patients were divided into the robot-assisted group (9 patients) or the traditional surgery group (9 patients). The operation time, blood loss, number of intra-operative fluoroscopies, fracture healing time, Mayo wrist function score, and screw implantation accuracy were recorded in the two groups. RESULTS: The average age of the robot-assisted group was 37.9 ± 10.6 years (with a range of 30 to 52 years), there were eight males and one female, and there were six cases of scaphoid fracture on the right side and three on the left side. The average pre-operative time was 2.8 ± 0.7 days (ranging from 1 to 3 days). The average age of the traditional surgery group was 31.6 ± 6.8 years (with a range of 20 to 45 years), there were eight males and one female, and there were five cases of scaphoid fracture on the right side and four on the left side. The average pre-operative time was 2.1 ± 0.8 days (with a range of 2 to 4 days). The number of intra-operative fluoroscopies was 24.4 ± 3.5 in the traditional surgery group, whereas it was only 10.1 ± 1.9 in the robot-assisted group, which was significantly lower (P < 0.05). The average operation time of the traditional operation group was 48.4 ± 12.2 min, and that of the robot-assisted group was 32.6 ± 4.2 minutes, which was significantly shorter (P < 0.05). The angles between the actual screw position and the central axis of the scaphoid on both the coronal and sagittal post-operative CT images were 8.3° ± 2.3° and 8.8° ± 1.6° for the traditional operation group and 3.8° ± 0.8° and 4.3° ± 1.2° for the robot-assisted group, so the accuracy of the robot-assisted group was significantly higher (P < 0.05). There were no significant differences between the two groups in wrist function recovery or fracture healing time. CONCLUSION: Robot-assisted treatment of scaphoid fracture is more accurate than traditional freehand technology, with shorter operation time and fewer intra-operative fluoroscopies. There is no difference between the two surgical techniques in intra-operative bleeding, post-operative fracture healing, or functional recovery. Robot-assisted surgery is a safe, effective, and accurate method for treating scaphoid fracture.


Asunto(s)
Fracturas Óseas , Traumatismos de la Mano , Robótica , Hueso Escafoides , Traumatismos de la Muñeca , Masculino , Humanos , Femenino , Adulto , Persona de Mediana Edad , Adulto Joven , Fracturas Óseas/cirugía , Estudios Retrospectivos , Fijación Interna de Fracturas/efectos adversos , Fijación Interna de Fracturas/métodos , Resultado del Tratamiento , Hueso Escafoides/cirugía , Hueso Escafoides/lesiones
8.
Sci Rep ; 12(1): 22250, 2022 12 23.
Artículo en Inglés | MEDLINE | ID: mdl-36564474

RESUMEN

A proline-rich region was found in Streptococcus mutans (S. mutans) surface antigen I/II (Ag I/II). The functions of this region were explored to determine its role in the cariogenic abilities of S. mutans; specifically, the proline-rich region was compared with human amelogenin. The full-length amelogenin genes were cloned from human (AmH) and surface antigen I/II genes from S. mutans. Then, the genes expressed and purified. We analyzed the structure and self-assembly ability of AmH and Ag I/II, compared their capacities to induce mineralization, and assessed the adhesion ability of S. mutans to AmH- and Ag I/II-coated tooth slices. AmH formed ordered chains and net frames in the early stage of protein self-assembly, while Ag I/II formed irregular and overlapping structures. AmH induced mineralization possessed a parallel rosary structure, while Ag I/II-induced mineralization is rougher and more irregular. The S. mutans adhesion assay indicated that the adhesion ability S. mutans on the Ag I/II-induced crystal layer was significantly higher than that on the AmH-induced crystal layer. S. mutans' Ag I/II may have evolved to resemble human amelogenin and form a rougher crystal layer on teeth, which play a competitive mineralization role and promotes better bacterial adhesion and colonization. Thus, the cariogenic ability of S. mutans Ag I/II is increased.


Asunto(s)
Adhesión Bacteriana , Streptococcus mutans , Humanos , Streptococcus mutans/genética , Prolina , Amelogenina , Anticuerpos , Antígenos de Superficie
9.
ACS Omega ; 7(10): 8706-8716, 2022 Mar 15.
Artículo en Inglés | MEDLINE | ID: mdl-35309471

RESUMEN

Inspired by the recent practical application of two-dimensional (2D) nanomaterials as gas sensors, catalysts, and materials for waste gas disposal, herein, the adsorption behaviors of environmental gas molecules, including NO, CO, O2, CO2, NO2, H2O, H2S, and NH3, on the 2D pristine and defective MoSi2N4 (MSN) monolayers were systematically investigated using spin-polarized density functional theory (DFT) calculations. Our results reveal that all the gas molecules are physically adsorbed on the MSN surface with small charge transfer, but the electronic structures of NO, NO2, and O2 are obviously modified due to the in-gap states. The introduction of N vacancy on the MSN surface enhances the interaction between gas molecules and the substrate, especially for NO2 and O2. Interestingly, the adsorption type of NO and CO evolves from physisorption to chemisorption, which may be utilized in NO and CO catalytic reaction. Furthermore, the moderate adsorption strength and obvious changes in electronic properties of H2O and H2S on the defective MSN make them have promising prospects in highly sensitive and reusable gas sensors. This work offers several promising gas sensors based on the MSN monolayer and also provides a theoretical reference of other related 2D materials in the field of gas sensors, catalysts, and toxic gas disposal.

10.
Front Surg ; 9: 1005200, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36684340

RESUMEN

Background: This systematic review and meta-analysis was performed to summarize available evidence of anterior transposition of the ulnar nerve for patients with distal humerus fractures. Materials and Methods: The databases were searched from PubMed, Cochrane, Embase, Scopus, Web of Science, Chinese National Knowledge Infrastructure (CNKI), Chongqing VIP Database (VIP), and Wan Fang Database up to June 2022. The clinical outcome included operation time, fracture healing time, hospital stays, elbow joint function, and ulnar neuritis rate. Statistical analysis was performed with Review Manager 5.3 (Cochrane Collaboration). Results: A total of 17 studies were included (8 RCTs and 9 retrospective studies), and 1280 patients were analyzed. The results of this meta-analysis showed anterior transposition group had longer operation time (MD = 20.35 min, 95%CI: 12.56-28.14, P < 0.00001). There was no significant difference in fracture healing time (SMD = -0.50, 95%CI: -1.50-0.50, P = 0.33), hospital stays (MD = -1.23 days, 95%CI: -2.72--0.27, P = 0.11), blood loss (MD = 2.66 ml, 95%CI: -2.45-7.76, P = 0.31), and ulnar neuritis rate (OR = 1.23, 95%CI: 0.63-2.42, P = 0.54) between two groups. Finally, elbow joint motion, elbow joint function, fracture nonunion, and post-operative infection (P > 0.05) between two groups were not significantly statistic difference. Conclusion: This meta-analysis showed that anterior transposition group is not superior to non-transposition group for patients with distal humerus fractures without ulnar nerve injury. On the contrary, non-transposition group have shorter operation time than that of anterior transposition group. Non-transposition group did not increase the post-operative ulnar neuritis rate. Therefore, both anterior transposition group and non- transposition group are the treatment options for patients with distal humerus fractures without ulnar nerve injury. Besides, these findings need to be further verified by multi-center, double-blind, and large sample RCTs.

11.
Ann Palliat Med ; 10(10): 10467-10474, 2021 10.
Artículo en Inglés | MEDLINE | ID: mdl-34763493

RESUMEN

BACKGROUND: To investigate the preventive effect of elastic stockings on deep vein thrombosis (DVT) after orthopedic surgery by literature search and meta-analysis. METHODS: PubMed, Embase and Cochrane were selected as the search database platforms to search the literature of randomized controlled trials related to elastic stockings and DVT published from 2008 to date. Revman 5.3.5 software was used for statistical analysis of the data to obtain forest and funnel plots. RESULTS: In this study, 90 studies were initially screened and 7 were finally included, covering a total of 3,116 patients. Meta-analysis showed that the 7 studies had statistical heterogeneity (I2=32%, P=0.18), so a random effect model was used. The obtained statistic was [odds ratio (OR) =0.59, 95% confidence interval (CI): (0.34, 1.03)], the statistical effect size was Z=1.84, P=0.07, and the difference was not statistically significant, so a stepwise sensitivity analysis was performed by the exclusion method. One study was excluded, and the remaining 6 showed homogeneity (I2=0%, P=0.46). They were analyzed by subgroup according to the type of operation: ankle surgery or hip and knee arthroplasty. The internal literatures of each subgroup were homogeneous: ankle surgery subgroup (I2=0%, P=0.43), hip and knee arthroplasty subgroup (I2=0%, P=0.88). Therefore, fixed effect mode analysis was used, and the effect size of elastic stockings after ankle surgery was Z=3.65, P=0.0003, while the effect size of elastic stockings in the hip and knee arthroplasty subgroup was Z=1.23, P=0.22. DISCUSSION: Elastic stockings had an obvious preventive effect on DVT in patients undergoing ankle surgery, but not in patients undergoing lumbar, knee or spinal surgery. It is necessary to combine anticoagulant drugs and other physical therapies to prevent DVT.


Asunto(s)
Procedimientos Ortopédicos , Trombosis , Trombosis de la Vena , Humanos , Procedimientos Ortopédicos/efectos adversos , Medias de Compresión , Trombosis de la Vena/prevención & control
12.
Life Sci ; 274: 119363, 2021 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-33737083

RESUMEN

AIMS: Post-fracture calcium and phosphorus excretion is greater than influx, which might be caused by stress. Glucocorticoid is known to enhance calcium and phosphorous excretion, and hydrogen sulfide (H2S) has been shown to exert inhibitory effects on glucocorticoid. Therefore, this study explored whether H2S could inhibit calcium and phosphorus loss after fracture by regulating glucocorticoid and/or its receptor. MAIN METHODS: The following properties were analyzed in rats with femur fractures: serum and urinary calcium and phosphorus (by colorimetry); bone turnover markers alkaline phosphatase, serum type 1 collagen amino terminal peptide, type 1 procollagen carboxy terminal peptide, and anti-tartaric acid phosphatase (by ELISA); factors related to calcium-phosphorus metabolism including glucocorticoid, parathyroid hormone, calcitonin, fibroblast growth factor 23, and 1,25(OH)2D3 (by ELISA); and sulfhydration of glucocorticoid receptor α in the kidney (by immunoprecipitation linked biotin-switch assay), after supplementing with mifepristone, the H2S donor GYY4137 or H2S generating enzyme inhibitors aminooxyacetic acid and propargylglycine. KEY FINDINGS: Serum H2S decreased and glucocorticoid secretion increased in rats post-fracture. The glucocorticoid receptor inhibitor mifepristone partly blunted calcium and phosphorus loss. Furthermore, supplementation with GYY4137 reduced glucocorticoid secretion; inhibited glucocorticoid receptor α activity by sulfhydration; downregulated vitamin D 1α-hydroxylase expression; and upregulated 24-hydroxylase, calbindin-D28k, and sodium phosphate cotransporter 2a expression in the kidney; thereby inhibiting calcium and phosphorus loss induced by fracture. Moreover, inhibiting endogenous H2S generation showed opposite effects. SIGNIFICANCE: Our findings suggest that H2S antagonized calcium and phosphorus loss after fracture by reducing glucocorticoid secretion and inhibiting glucocorticoid receptor α activity by sulfhydration.


Asunto(s)
Calcio/metabolismo , Fracturas del Fémur/tratamiento farmacológico , Regulación de la Expresión Génica/efectos de los fármacos , Sulfuro de Hidrógeno/farmacología , Morfolinas/farmacología , Compuestos Organotiofosforados/farmacología , Fósforo/metabolismo , Receptores de Glucocorticoides/antagonistas & inhibidores , Animales , Fracturas del Fémur/metabolismo , Fracturas del Fémur/patología , Gasotransmisores/farmacología , Masculino , Ratas , Ratas Sprague-Dawley
13.
Orthop Surg ; 13(1): 244-252, 2021 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-33448703

RESUMEN

OBJECTIVE: To assess the long-term clinical efficacy of TiRobot-assisted percutaneous cannulated screw fixation in the treatment of femoral neck fractures. METHODS: This retrospective study included 50 patients with unilateral femoral neck fractures who were treated with TiRobot-assisted percutaneous cannulated screw fixation from September 2017 to May 2018. After at least 2 years of follow-up, the results of treatment, including operation duration, frequency of fluoroscopy use, intraoperative bleeding, hospital stay, medical expense, screw placement accuracy, rate of fracture healing and necrosis of the femoral head, and Harris hip scores at the last follow up, were recorded and compared with those of 83 matched patients who underwent conventional manual positioning surgery. RESULTS: The TiRobot group had longer operation duration (83.3 ± 31.2 min vs 44.1 ± 14.8 min) and higher medical expenses (28,407.1 ± 7498.0 yuan vs 22,672.3 ± 4130.3 yuan) than the conventional group. The TiRobot group had significantly less intraoperative bleeding (11.3 ± 7.3 mL vs 51.6 ± 40.4 mL) and shorter hospital stay (8.6 ± 2.8 days vs 11.1 ± 3.41 days) than the conventional group. Screw parallelism (1.32° ± 1.85° vs 2.54° ± 2.99° on anteroposterior radiograph; 1.42° ± 2.25° vs 3.09° ± 3.63° on lateral radiograph) and distance between screws (58.44 ± 10.52 mm vs 39.69 ± 12.17 mm) were significantly improved. No significant difference was found between the two groups in terms of the use of fluoroscopy (40.1 ± 28.5 times vs 38.6 ± 21.0 times) and Harris hip scores at the last follow-up (93.2 ± 10.3 points vs 88.4 ± 11.9 points). Two cannulated screws penetrated the femoral head during manual insertion in the conventional group but not in the TiRobot group. The rate of nonunion and necrosis of the femoral head in the TiRobot group was reduced compared with that in the conventional group (0 vs 7.2%; 6.0% vs 24.1%). CONCLUSION: TiRobot-assisted percutaneous cannulated screw fixation of femoral neck fractures is accurate and minimally invasive and helps in reducing late complications, particularly necrosis of the femoral head and nonunion of fractures.


Asunto(s)
Tornillos Óseos , Fracturas del Cuello Femoral/cirugía , Fijación Interna de Fracturas/métodos , Procedimientos Quirúrgicos Robotizados/métodos , Adulto , Evaluación de la Discapacidad , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias , Estudios Retrospectivos
14.
Medicine (Baltimore) ; 99(14): e19684, 2020 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-32243406

RESUMEN

BACKGROUND: Fracture is a common disease; many factors affect fracture healing. Recent studies have confirmed that hydrogen sulfide (H2S) plays an essential role in bone formation, but most of these studies are drawing conclusions based on animal experiment; whether H2S could promote fracture healing in patients is still unclear. We aim to investigate the change of serum H2S in fracture patients, and analyze its effort on fracture healing. METHODS: This is a single-center, prospective cohort study. Patients with spinal or limb fracture will be recruited. Patient's serum and urine will be collected at baseline for examination (serum H2S, ß-CTX, OC, PINP, 25-OH-VitD3, S-CTX, urinary calcium, and urinary creatinine). All patients will be followed-up for 24 months in outpatients settings, the image of X-ray or CT will be reviewed and fracture healing will be judged by 2 experienced orthopedic physicians. The difference in serum parameters especially H2S will be compared between patients with fracture healed within 9 months and those with fracture unhealed at 9 months. DISCUSSION: Results of the trial could provide insight into influence of H2S on fracture healing. ETHICS AND DISSEMINATION: The study was approved by the ethics committee of School of Medicine UESTC & Sichuan Provincial People's Hospital Ethics Committee. All the participants will be asked to provide written informed consent before data collection. The findings of the study will be published in peer-reviewed journals and will be presented at national or international conferences.


Asunto(s)
Curación de Fractura/fisiología , Fracturas Óseas/sangre , Sulfuro de Hidrógeno/sangre , Traumatismos del Brazo/sangre , Fracturas Óseas/orina , Humanos , Sulfuro de Hidrógeno/orina , Traumatismos de la Pierna/sangre , Osteogénesis/fisiología , Estudios Prospectivos , Fracturas de la Columna Vertebral/sangre
15.
Nanoscale ; 12(3): 1541-1550, 2020 Jan 23.
Artículo en Inglés | MEDLINE | ID: mdl-31854412

RESUMEN

The electrocatalytic reduction of naturally abundant N2 to NH3 is an attractive approach to replace the Haber-Bosch nitrogen-fixation process that causes enormous energy consumption and greenhouse gas emissions. However, designing high-performance catalysts toward the electrocatalytic N2 reduction reaction (eNRR) remains one of the greatest challenges in this area. Herein, high-throughput screening of catalysts for the NRR among a series of transition metal atoms supported on a defective hexagonal boron nitride (h-BN) nanosheet is performed through spin-polarized density functional theory (DFT) computations. Strikingly, among the 18 candidates, the V/Tc atom anchored on a defective h-BN monolayer (V@BN and Tc@BN) showed good NRR activity with relatively low onset potentials. Particularly, V@BN was found to exhibit outstanding catalytic activity for the NRR via an enzymatic pathway with an extremely low overpotential of 0.25 V. The value is significantly lower than that on the Ru (0001) stepped surface that has the best NRR catalytic performance among bulk metal catalysts. The novel NRR activity of V@BN is attributed to the enhanced electrical conductivity due to V-doping, the "donation-backdonation" process for N2 activation, and the highly centralized spin-polarization on the V atom. This work not only provides a quite promising catalyst for the NRR but also provides new insights for the rational design of single-atom NRR catalysts.

16.
Plast Reconstr Surg ; 137(2): 523-533, 2016 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-26818287

RESUMEN

BACKGROUND: A central issue underlying end-to-side neurorrhaphy technique is whether injury to the donor nerve fibers is necessary for successful reinnervation of the recipient nerve. To address this question, the authors developed a novel atraumatic end-to-side neurorrhaphy model that uses the preexisting anatomical structure of the median nerve as the Y-chamber to study the mechanism of collateral sprouting. METHODS: In this rat forelimb model, the authors transected the musculocutaneous nerve and the lateral head of the median nerve, and coapted their distal stumps together. In this model, the authors use the medial head of the median nerve as the donor nerve, and the lateral head of the median nerve (distal stump) as a Y-shaped chamber, which provided structural connection to the recipient musculocutaneous nerve in end-to-side fashion. RESULTS: Three months after surgery, converging histologic, electrophysiologic, and behavioral observations confirmed the successful reinnervation of the recipient nerve. Retrograde labeling indicated that sensory fibers exhibited greater collateral sprouting than observed for motor fibers. Interestingly, fluorescence of these collateral sprouting fibers was present only when the median nerve lateral head was attached to the musculocutaneous nerve of the biceps, indicating that factors derived from the denervated tissue likely induced the collateral sprouting in this model. CONCLUSIONS: The authors' findings provide strong evidence that collateral sprouting can be robustly initiated independent of donor nerve fiber injury. The authors' model can accelerate the understanding of the mechanism underlying end-to-side neurorrhaphy and the optimization of its clinical use.


Asunto(s)
Nervio Mediano/cirugía , Nervio Musculocutáneo/cirugía , Regeneración Nerviosa/fisiología , Procedimientos Neuroquirúrgicos/métodos , Traumatismos de los Nervios Periféricos/cirugía , Procedimientos de Cirugía Plástica/métodos , Nervio Cubital/cirugía , Anastomosis Quirúrgica/métodos , Animales , Modelos Animales de Enfermedad , Femenino , Nervio Mediano/lesiones , Nervio Musculocutáneo/lesiones , Fibras Nerviosas/patología , Ratas , Ratas Sprague-Dawley , Nervio Cubital/lesiones
17.
J Reconstr Microsurg ; 30(5): 297-304, 2014 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-24683138

RESUMEN

The purpose of this study was to compare the outcomes of different numbers of intercostal nerve (ICN) transfers for elbow flexion and to determine whether age, body mass index (BMI), type of injury, and preoperative delay influence the outcomes. From 2004 to 2010, 32 (30 included) consecutive patients underwent ICN transfer to the musculocutaneous nerve following brachial plexus injury. Elbow flexion strength was evaluated according to the British Medical Research Council (BMRC) grading system. Of nine patients who received two ICN transfers, six (66.7%) recovered with useful elbow flexion compared with 14 of 17 (82.4%) patients who received three ICN transfers. Of the four patients with four ICN transfers, three (75%) achieved useful recovery. Statistical analysis showed no significant difference. There is no significant difference among the outcomes of two, three, and four ICN transfers to the musculocutaneous nerve. Two ICN transfers are sufficient for useful recovery of elbow flexion. Younger patients achieve better results.


Asunto(s)
Neuropatías del Plexo Braquial/cirugía , Plexo Braquial/lesiones , Plexo Braquial/cirugía , Articulación del Codo/fisiopatología , Nervios Intercostales/trasplante , Músculo Esquelético/inervación , Nervio Musculocutáneo/fisiopatología , Transferencia de Nervios/métodos , Adolescente , Adulto , Factores de Edad , Índice de Masa Corporal , Plexo Braquial/fisiopatología , Neuropatías del Plexo Braquial/etiología , Articulación del Codo/cirugía , Femenino , Estudios de Seguimiento , Humanos , Nervios Intercostales/cirugía , Masculino , Persona de Mediana Edad , Músculo Esquelético/fisiopatología , Nervio Musculocutáneo/cirugía , Regeneración Nerviosa , Conducción Nerviosa , Rango del Movimiento Articular , Recuperación de la Función , Estudios Retrospectivos , Resultado del Tratamiento
18.
Respir Physiol Neurobiol ; 196: 25-32, 2014 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-24556382

RESUMEN

The degree of impairment of ventilation and exercise performance after unilateral diaphragmatic paralysis (UDP) induced by phrenic nerve injury has been controversial due to heterogeneity in the published clinical studies. The aim of this study was to assess the effect of isolated UDP on breathing and exercise performance in conscious rats. Breathing was measured by unrestrained whole body plethysmography during quiet breathing and after moderate aerobic exercise. Additionally, incremental exercise testing was performed to evaluate the effects of intensive activity. The results demonstrated that complete UDP in rats resulted in a permanent decrease of peak inspiratory flow at rest breathing. Nevertheless, adequate ventilation could be maintained, and the breathing pattern was unaltered due to a strong compensatory mechanism and central re-coordination initiated by UDP. After being affected at an early stage, the ventilatory response to exercise was gradually regained and subsequently restored.


Asunto(s)
Actividad Motora/fisiología , Respiración , Parálisis Respiratoria/fisiopatología , Animales , Prueba de Esfuerzo , Femenino , Inhalación/fisiología , Nervio Frénico/lesiones , Pletismografía Total , Distribución Aleatoria , Ratas , Ratas Sprague-Dawley , Recuperación de la Función , Parálisis Respiratoria/etiología , Factores de Tiempo
20.
J Perinat Med ; 42(5): 585-9, 2014 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-24566358

RESUMEN

OBJECTIVE: To evaluate the risk of developing pulmonary edema in women exposed to nifedipine, magnesium sulfate (MgSO4), or both in a preterm setting. STUDY DESIGN: We carried out a retrospective case-control study at a large tertiary care center from 2007 to 2012. Cases of pulmonary edema were age, and gestational age matched to controls at a ratio of 1 case to 4 controls. Logistic regression analysis was used to estimate the effect of nifedipine and/or MgSO4 on the development of pulmonary edema while controlling for predetermined confounding variables. Stepwise logistic regression analysis was used to evaluate additional risk factors of pulmonary edema. RESULTS: A total of 150 charts were reviewed (28 cases and 122 controls). Nifedipine did not increase the odds of developing pulmonary edema [adjusted odds ratio (OR)=1.22 (confidence interval (CI) 0.50, 3.01), P=0.67], whereas exposure to MgSO4, or both MgSO4 and nifedipine, significantly increased the risk of developing pulmonary edema [adjusted OR=3.91 (CI 1.44, 10.65), P=0.008 and adjusted OR=4.75 (CI 1.15, 19.71), P=0.032, respectively]. In the stratified analysis, this association persisted even in nonpreeclamptic women [nifedipine: adjusted OR=0.91 (CI 0.33, 2.52), P=0.852; MgSO4: adjusted OR=3.51 (CI 1.26, 9.76), P=0.016; both: adjusted OR=3.39 (0.76, 15.07), P=0.108]. Other independent risk factors for pulmonary edema were multi-fetal pregnancy, azithromycin, and erythromycin administration. CONCLUSION: MgSO4 treatment is strongly associated with the development of pulmonary edema when used either as a tocolytic agent or for seizure prophylaxis. In light of the availability of safer alternatives, MgSO4 should be used for tocolysis only in cases whereby the benefits clearly outweigh the risks.


Asunto(s)
Sulfato de Magnesio/efectos adversos , Nifedipino/efectos adversos , Complicaciones del Embarazo/etiología , Edema Pulmonar/etiología , Tocolíticos/efectos adversos , Adulto , Azitromicina/administración & dosificación , Azitromicina/efectos adversos , Estudios de Casos y Controles , Sinergismo Farmacológico , Eritromicina/administración & dosificación , Eritromicina/efectos adversos , Femenino , Humanos , Recién Nacido , Modelos Logísticos , Sulfato de Magnesio/administración & dosificación , Nifedipino/administración & dosificación , Trabajo de Parto Prematuro/tratamiento farmacológico , Embarazo , Embarazo Múltiple , Nacimiento Prematuro/prevención & control , Edema Pulmonar/complicaciones , Estudios Retrospectivos , Factores de Riesgo , Tocólisis , Tocolíticos/administración & dosificación , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA