Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Más filtros













Base de datos
Intervalo de año de publicación
1.
AAPS J ; 24(3): 52, 2022 04 06.
Artículo en Inglés | MEDLINE | ID: mdl-35384529

RESUMEN

In-clinic dried blood spot (DBS) pharmacokinetic (PK) sampling was incorporated into two phase 3 studies of verubecestat for Alzheimer's disease (EPOCH [NCT01739348] and APECS [NCT01953601]), as a potential alternative to plasma PK sampling for improved logistical feasibility and decreased blood volume burden. However, an interim PK analysis revealed verubecestat concentrations in DBS samples declined with time to assay in both trials. An investigation revealed wide variation in implementation practices for DBS sample handling procedures resulting in insufficient desiccation which caused verubecestat instability. High-resolution mass spectrometry evaluations of stressed and aged verubecestat DBS samples revealed the presence of two hydrolysis degradants. To minimize instability, new DBS handling procedures were implemented that provided additional desiccant and minimized the time to analysis. Both verubecestat hydrolysis products were previously discovered and synthesized during active pharmaceutical ingredient stability characterization. A liquid chromatography-mass spectrometry assay to quantitate the dominant verubecestat degradant in DBS samples was developed and validated. The application of this method to stressed and aged verubecestat DBS samples confirmed that degradant concentrations accounted for the observed decreases in the verubecestat concentration. Furthermore, after increasing desiccant amounts, degradant concentrations accounted for approximately 7% of the verubecestat concentration in DBS clinical samples, indicating that issues with sample handling were minimized with new storage and shipping conditions. This case study illustrates the challenges with employing new sampling techniques in large, global trials, and the importance of anticipating and mitigating implementation risks.


Asunto(s)
Pruebas con Sangre Seca , Espectrometría de Masas en Tándem , Óxidos S-Cíclicos , Pruebas con Sangre Seca/métodos , Higroscópicos , Manejo de Especímenes , Espectrometría de Masas en Tándem/métodos , Tiadiazinas
2.
Clin Transl Sci ; 13(3): 482-490, 2020 05.
Artículo en Inglés | MEDLINE | ID: mdl-31758661

RESUMEN

Ubrogepant (MK-1602) is a novel, oral, calcitonin gene-related peptide receptor antagonist in clinical development with positive phase III outcomes for acute treatment of migraine. This paper describes the population exposure-response (E-R) modeling and simulations, which were used to inform the phase III dose-selection rationale, based on ~ 800 participants pooled across two phase IIb randomized dose-finding clinical trials. The E-R model describes the placebo and ubrogepant treatment effects based on migraine pain end points (2-hour pain relief and 2-hour pain freedom) at various dose levels. Sensitivity analyses were conducted to evaluate various assumptions of placebo response in light of the high placebo response observed in one phase II trial. A population pharmacokinetic model describing the effect of formulations was included in the E-R simulation framework to assess potential dose implications of a formulation switch from phase II to phase III. Model-based simulations predict that a dose of 25 mg or higher is likely to achieve significantly better efficacy than placebo with desirable efficacy levels. The understanding of E-R helped support the dose selection for the phase III clinical trials.


Asunto(s)
Toma de Decisiones Clínicas/métodos , Trastornos Migrañosos/tratamiento farmacológico , Piridinas/administración & dosificación , Pirroles/administración & dosificación , Adolescente , Adulto , Anciano , Ensayos Clínicos Fase III como Asunto , Relación Dosis-Respuesta a Droga , Método Doble Ciego , Femenino , Humanos , Masculino , Persona de Mediana Edad , Trastornos Migrañosos/diagnóstico , Modelos Biológicos , Dimensión del Dolor , Piridinas/efectos adversos , Piridinas/farmacocinética , Pirroles/efectos adversos , Pirroles/farmacocinética , Factores de Tiempo , Resultado del Tratamiento , Adulto Joven
3.
Bioanalysis ; 11(4): 233-250, 2019 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-30767560

RESUMEN

Aim: MK-8591 (EFdA), a novel anti-HIV nucleoside analog, is converted to mono-, di- and tri-phosphates (MK-8591-MP, MK-8591-DP and MK-8591-TP) intracellularly, among which MK-8591-TP is the active pharmacological form. An ultrasensitive LC-MS/MS assay was required to measure MK-8591-DP and MK-8591-TP levels in human peripheral blood mononuclear cells (PBMCs). Sensitivity and reproducibility were major bottlenecks in these analyses. Materials and methods: Human PBMCs were isolated from blood and lysed with 70/30 methanol/RPMI-1640. An LC-MS/MS method was developed to simultaneously quantify MK-8591-DP and MK-8581-TP in PBMC lysates. Results: Low flow LC and dimethyl sulfoxide mediated signal enhancement enabled an extreme sensitivity with limit of quantitation at 0.1 ng/ml. Assay accuracy was 92.5-106% and precision was 0.7-12.1% for a linear curve range of 0.1-40 ng/ml. Matrix variability and interference liability were comprehensively evaluated. Conclusion: Our study findings and steps taken in addressing clinical sample issues help understand and overcome the challenges facing intracellular nucleotide analog analysis.

4.
Clin Pharmacol Ther ; 105(1): 168-176, 2019 01.
Artículo en Inglés | MEDLINE | ID: mdl-29885208

RESUMEN

Merck & Co, Inc (Kenilworth, NJ) is investing in approaches to enrich clinical trial data and augment decision making through use of digital health technologies, outpatient sampling, and real-time data access. As part of this strategy, a phase I study was conducted to explore a few technologies of interest. In this fixed-sequence two-period trial, 16 healthy subjects were administered 50-mg once-daily sitagliptin packaged in a bottle that electronically captured the date and time study medication was dispensed (period 1) and in a traditional pharmacy bottle (period 2). Dried blood spot samples were collected for sitagliptin concentration analysis on select study days, both in clinic and at home, with collection time recorded using an electronic diary in period 1 and by clinic staff in period 2. Study results demonstrated the feasibility and subject acceptance of collecting digital adherence data and outpatient dried blood spot samples in clinical trials and highlighted areas for future improvements.


Asunto(s)
Pruebas con Sangre Seca/métodos , Desarrollo de Medicamentos/métodos , Hipoglucemiantes/sangre , Fosfato de Sitagliptina/sangre , Telemedicina/métodos , Adulto , Pruebas con Sangre Seca/normas , Desarrollo de Medicamentos/normas , Femenino , Humanos , Hipoglucemiantes/administración & dosificación , Masculino , Persona de Mediana Edad , Fosfato de Sitagliptina/administración & dosificación , Manejo de Especímenes/métodos , Manejo de Especímenes/normas , Encuestas y Cuestionarios/normas , Telemedicina/normas , Adulto Joven
5.
Bioanalysis ; 10(15): 1207-1220, 2018 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-30062907

RESUMEN

AIM: Advances in technology have led to a shift for peptide quantification from traditional ligand-binding assays to LC-MS/MS-based analysis, which presents challenges, in other assay sensitivity, specificity and ruggedness, in addition to lacking of regulatory guidance, especially for the hybrid assay format. Methodology & results: This report communicates a strategy that has been employed in our laboratories for method development and assay validation, and exemplified in a case study of MK-2640, a glucose-responsive insulin, in multiple matrices. Intact MK-2640 was monitored, while immunoaffinity purification and SPE were used to support the rat/dog GLP and clinical studies, respectively. The rationale and considerations behind our approach, as well as the acceptance criteria applied to the assay validation are discussed.


Asunto(s)
Cromatografía Líquida de Alta Presión , Insulina/análogos & derivados , Péptidos/sangre , Espectrometría de Masas en Tándem , Animales , Anticuerpos Monoclonales/inmunología , Cromatografía de Afinidad , Perros , Semivida , Humanos , Insulina/análisis , Insulina/química , Insulina/farmacología , Insulina de Acción Prolongada/química , Insulina de Acción Corta/química , Insulinas/química , Insulinas/inmunología , Límite de Detección , Péptidos/aislamiento & purificación , Péptidos/farmacocinética , Ratas , Reproducibilidad de los Resultados , Extracción en Fase Sólida
6.
J Pharm Biomed Anal ; 156: 58-66, 2018 Jul 15.
Artículo en Inglés | MEDLINE | ID: mdl-29689469

RESUMEN

Volumetric absorptive microsampling (VAMS), a new microsampling technique, was evaluated for its potential in supporting regulated bioanalysis. Our initial assessment with MK-0518 (raltegravir) using a direct extraction method resulted in 45-52% extraction recovery, significant hematocrit (Ht) related bias, and more importantly, unacceptable stability (>15% bias from nominal concentration) after 7-day storage. Our investigation suggested that the observed biases were not due to VAMS absorption, sampling techniques, lot-to-lot variability, matrix effect, and/or chemical stability of the compound, but rather the low extraction recovery. An effort to improve assay recovery led to a modified liquid-liquid extraction (LLE) method that demonstrated more consistent performance, minimal Ht impact (Ht ranged from 20 to 65%), and acceptable sample stability. The same strategy was successfully applied to another more hydrophilic model compound, MK-0431 (sitagliptin). These results suggest that the previously observed Ht effect and "instability" were in fact due to inconsistent extractability, and optimizing the extraction recovery to greater than 80% was critical to ensure VAMS performance. We recommend adding Ht-independent recovery as part of feasibility assessment to de-risk the long-term extractability-mediated stability bias before implementing VAMS in regulated bioanalysis.


Asunto(s)
Recolección de Muestras de Sangre/métodos , Fraccionamiento Químico/métodos , Pruebas con Sangre Seca/métodos , Raltegravir Potásico/aislamiento & purificación , Recolección de Muestras de Sangre/instrumentación , Fraccionamiento Químico/instrumentación , Cromatografía Líquida de Alta Presión , Pruebas con Sangre Seca/instrumentación , Estabilidad de Medicamentos , Hematócrito , Raltegravir Potásico/sangre , Raltegravir Potásico/química , Estándares de Referencia , Fosfato de Sitagliptina/sangre , Fosfato de Sitagliptina/química , Fosfato de Sitagliptina/aislamiento & purificación , Espectrometría de Masas en Tándem
7.
J Clin Pharmacol ; 58(3): 294-303, 2018 03.
Artículo en Inglés | MEDLINE | ID: mdl-29136283

RESUMEN

Merck & Co., Inc. (Kenilworth, New Jersey) has recently published an integrated strategy for implementation of dried blood spots (DBS) in late-stage trials for population pharmacokinetic (PK) modeling. We applied this strategy for another late-stage clinical program: ubrogepant (MK-1602), a novel oral calcitonin gene-related peptide receptor antagonist for acute treatment of migraine. At the time of implementation, ubrogepant was entering phase 2 development. DBS was implemented to acquire PK information proximal to an acute migraine event to enable exposure-response modeling. The clinical endpoint was a spontaneous event, which generally occurs outside a clinic visit. Thus, an innovative feature of this trial was facilitating DBS in an outpatient setting. In vitro and bioanalytical tests established initial method feasibility and suitability for further evaluations in the clinic. A quantitative relationship was developed between blood and plasma concentrations from concurrently collected samples in a phase 1 (healthy subjects) and phase 2 (target patient population) study using graphical and population PK approaches. This integrated information was presented to the Food and Drug Administration for regulatory input. Following regulatory concurrence, DBS was poised for use in further clinical studies. Population PK modeling was used to dissect sources of variability contributing to DBS collection in the outpatient setting. What has been learned from this program has informed the broader integrated strategy of Merck & Co., Inc. (Kenilworth, NJ) for DBS implementation in clinical trials and research to improve the precision of PK data collected in an outpatient setting.


Asunto(s)
Antagonistas del Receptor Peptídico Relacionado con el Gen de la Calcitonina/sangre , Antagonistas del Receptor Peptídico Relacionado con el Gen de la Calcitonina/farmacocinética , Trastornos Migrañosos/sangre , Trastornos Migrañosos/tratamiento farmacológico , Piridinas/sangre , Piridinas/farmacocinética , Pirroles/sangre , Pirroles/farmacocinética , Adulto , Antagonistas del Receptor Peptídico Relacionado con el Gen de la Calcitonina/administración & dosificación , Relación Dosis-Respuesta a Droga , Pruebas con Sangre Seca , Femenino , Humanos , Persona de Mediana Edad , Piridinas/administración & dosificación , Pirroles/administración & dosificación , Encuestas y Cuestionarios
8.
J Pharm Sci ; 103(2): 636-42, 2014 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-24382706

RESUMEN

Preclinical studies in dogs are often employed as part of formulation screening process. However, the shorter transit time and colonic length in dogs may result in underestimation of absorption, especially for extended-release (ER) formulations. In the recent years, minipigs have attracted attention as an alternative animal model. However reports on studies with ER formulations are limited. In this manuscript, we report the first comprehensive comparison of minipig and clinical data for two types of ER formulations. Matrix tablets and multiparticulates in capsules of a BCS Class III compound were tested in the Yucatan minipig model. The relative performance of the formulations in minipigs in the fasted state was reasonably aligned with the clinical observations. The minipig model was able to rank order the formulations, reflecting the targeted release rate, in a manner consistent with the clinical data. Minipigs also reflected the loss of bioavailability relative to the immediate-release formulation. A level C in vitro/in vivo correlation was demonstrated for both the minipig and clinical data. However, an assessment of food effect in the minipig model appeared challenging, especially for the matrix formulation for which a negative food effect was observed in minipigs compared with the positive food effect in the clinic.


Asunto(s)
Química Farmacéutica/métodos , Preparaciones de Acción Retardada/química , Porcinos Enanos/fisiología , Porcinos/fisiología , Animales , Área Bajo la Curva , Benzamidas/administración & dosificación , Benzamidas/farmacocinética , Disponibilidad Biológica , Células CACO-2 , Cápsulas , Permeabilidad de la Membrana Celular , Portadores de Fármacos , Activadores de Enzimas/administración & dosificación , Activadores de Enzimas/farmacocinética , Excipientes , Femenino , Interacciones Alimento-Droga , Humanos , Derivados de la Hipromelosa , Masculino , Metilcelulosa/análogos & derivados , Modelos Biológicos , Solubilidad , Sulfonas/administración & dosificación , Sulfonas/farmacocinética , Comprimidos
9.
Assay Drug Dev Technol ; 2(1): 71-80, 2004 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-15090212

RESUMEN

With robotics widely used in bioanalytical assays, accurate system performance is essential to ensure the quality and productivity of the robotics. In our lab, an automated calibration procedure has been developed to evaluate the precision and accuracy of the TECAN (Research Triangle Park, NC, U.S.A.) Genesis liquid handling system in a bioanalytical laboratory setting. The calibrations were performed by transferring and weighing the solvents automatically on a microbalance controlled by a Gemini program. From the data acquired, calibration reports were generated using a template. The novel aspect of this approach is the use of an on-line balance and a density meter, both of which combine to make the calibration process simple, efficient, and precise. For quantitative bioanalysis, a variety of solvents, including methanol, water, mixed solvents, and plasma, are typically used to prepare standards and unknown samples. Density information is usually unknown for the mixed solvents, and the density of plasma can vary from species to species. However, with the use of a universal density meter, the density could be obtained in seconds. The issue of solvent evaporation during the calibration process was also addressed. Calibration curves were set up for various liquid classes. Pipetting volumes ranged from 10 microL to 900 microL. Precision and accuracy results obtained from the semiannual performance evaluations showed this procedure to be reliable and user-friendly. Using the automated calibration procedure, the calibration and performance evaluation of the robotic system is considerably more efficient, and the incidence of unacceptable precision and accuracy is greatly reduced.


Asunto(s)
Bioensayo/instrumentación , Calibración , Automatización , Bioensayo/normas , Células CACO-2 , Permeabilidad de la Membrana Celular , Densitometría , Documentación , Humanos , Indicadores y Reactivos , Sistemas en Línea , Control de Calidad , Robótica , Programas Informáticos , Solventes , Pesos y Medidas
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA