Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Lab Med ; 54(5): 512-518, 2023 Sep 05.
Artículo en Inglés | MEDLINE | ID: mdl-36810591

RESUMEN

Massive-scale SARS-CoV-2 testing using the SwabSeq diagnostic platform came with quality assurance challenges due to the novelty and scale of sequencing-based testing. The SwabSeq platform relies on accurate mapping between specimen identifiers and molecular barcodes to match a result back to a patient specimen. To identify and mitigate mapping errors, we instituted quality control using placement of negative controls within a rack of patient samples. We designed 2-dimensional paper templates to fit over a 96-position rack of specimens with holes to show the control tube placements. We designed and 3-dimensionally printed plastic templates that fit onto 4 racks of patient specimens and provide accurate indications of the correct control tube placements. The final plastic templates dramatically reduced plate mapping errors from 22.55% in January 2021 to less than 1% after implementation and training in January 2021. We show how 3D printing can be a cost-effective quality assurance tool to mitigate human error in the clinical laboratory.


Asunto(s)
COVID-19 , SARS-CoV-2 , Humanos , SARS-CoV-2/genética , COVID-19/diagnóstico , Prueba de COVID-19 , Secuenciación de Nucleótidos de Alto Rendimiento , Impresión Tridimensional , Plásticos
2.
Lab Med ; 53(1): e8-e13, 2022 Jan 06.
Artículo en Inglés | MEDLINE | ID: mdl-34436601

RESUMEN

OBJECTIVE: To describe and quantify the effect of quality control (QC) metrics to increase testing efficiency in a high-complexity, Clinical Laboratory Improvement Amendments-certified laboratory that uses amplicon-based, next generation sequencing for the clinical detection of SARS-CoV-2. To enable rapid scalability to several thousands of specimens per day without fully automated platforms, we developed internal QC methods to ensure high-accuracy testing. METHODS: We implemented procedures to increase efficiency by applying the Lean Six Sigma model into our sequencing-based COVID-19 detection. RESULTS: The application of the Lean Six Sigma model increased laboratory efficiency by reducing errors, allowing for a higher testing volume to be met with minimal staffing. Furthermore, these improvements resulted in an improved turnaround time. CONCLUSION: Lean Six Sigma model execution has increased laboratory efficiency by decreasing critical testing errors and has prepared the laboratory for future scaling up to 50,000 tests per day.


Asunto(s)
Prueba de COVID-19 , Laboratorios Clínicos , Gestión de la Calidad Total , COVID-19/diagnóstico , Humanos , SARS-CoV-2/aislamiento & purificación
3.
Neural Regen Res ; 8(17): 1541-1550, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-24459465

RESUMEN

The electrodes of a cochlear implant are located far from the surviving neurons of the spiral ganglion, which results in decreased precision of neural activation compared to the normal ear. If the neurons could be induced to extend neurites toward the implant, it might be possible to stimulate more discrete subpopulations of neurons, and to increase the resolution of the device. However, a major barrier to neurite growth toward a cochlear implant is the fluid filling the scala tympani, which separates the neurons from the electrodes. The goal of this study was to evaluate the growth of cochlear neurites in three-dimensional extracellular matrix molecule gels, and to increase biocompatibility by using fibroblasts stably transfected to produce neurotrophin-3 and brain-derived neurotrophic factor. Spiral ganglion explants from neonatal rats were evaluated in cultures. They were exposed to soluble neurotrophins, cells transfected to secrete neurotrophins, and/or collagen gels. We found that cochlear neurites grew readily on collagen surfaces and in three-dimensional collagen gels. Co-culture with cells producing neurotrophin-3 resulted in increased numbers of neurites, and neurites that were longer than when explants were cultured with control fibroblasts stably transfected with green fluorescent protein. Brain-derived neurotrophic factor-producing cells resulted in a more dramatic increase in the number of neurites, but there was no significant effect on neurite length. It is suggested that extracellular matrix molecule gels and cells transfected to produce neurotrophins offer an opportunity to attract spiral ganglion neurites toward a cochlear implant.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...