Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 401
Filtrar
1.
Artículo en Inglés | MEDLINE | ID: mdl-39278576

RESUMEN

BACKGROUND: Right ventricular (RV) involvement has been reported in type 2 diabetes mellitus (T2DM). The relationship between glycemic control and RV function remains unknown. We aimed to investigate the association between glycemic control and RV function assessed by two-dimensional speckle-tracking echocardiography (2D-STE) and three-dimensional echocardiography (3DE) in T2DM individuals. METHODS: This study prospectively enrolled 207 patients with T2DM and 84 individuals with normal glucose metabolism (NGM). T2DM patients were divided into two subgroups according to glycated hemoglobin (HbA1c) level: controlled (HbA1c < 7.0%, n = 91) and uncontrolled subgroup (HbA1c ≥ 7.0%, n = 116). RV free wall longitudinal strain (RVFWLS) was acquired by 2D-STE, RV volumes and RV ejection fraction (RVEF) were assessed using 3DE. RV coupling to pulmonary circulation was defined as the ratio of RVFWLS/pulmonary artery systolic pressure (PASP). RESULTS: Controlled and uncontrolled T2DM subgroups had impaired RV function as reflected by reduced RVFWLS and RVEF compared to the NGM group. The reduction in RVFWLS was more pronounced in the uncontrolled subgroup than in the controlled subgroup (P < 0.001), whereas no significant difference was found in RVEF between these two T2DM subgroups. Higher PASP and lower RVFWLS/PASP ratio were also noted in uncontrolled T2DM patients. Additionally, the incidence of RV dysfunction was significantly higher in the uncontrolled T2DM patients than in the controlled subgroup (43.1% vs 17.6%, P < 0.001). After adjustment for potential clinical confounders, PASP and left ventricular parameters, HbA1c level was independently associated with RVFWLS (ß = 0.290, P = 0.003) and RVFWLS/PASP ratio (ß = 0.028, P = 0.006). CONCLUSIONS: Subclinical RV myocardial dysfunction is present in T2DM patients and is more pronounced in patients with uncontrolled blood glucose. HbA1c level is independently associated with subclinical RV myocardial dysfunction, providing further insight into a possible link between poor glycemic control and diabetic cardiomyopathy.

3.
Front Cardiovasc Med ; 11: 1405754, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39175629

RESUMEN

Purpose: The impact of aortic stenosis (AS) severity on multidirectional myocardial function in patients with bicuspid aortic valve (BAV) remains unclear, despite the recognized presence of early left ventricular longitudinal myocardial dysfunction in BAV patients with normal valve function. The aim of the study was to evaluate the multidirectional myocardial functions of BAV patients. Methods: A total of 86 BAV patients (age 46.71 ± 13.62 years, 69.4% men) with normally functioning (BAV-nf), mild AS, moderate AS, and severe AS with preserved left ventricular ejection fraction (LVEF ≥ 52%) were included. 30 healthy volunteers were recruited as the control group. Multidirectional strain and volume analysis were performed by three-dimensional speckle tracking echocardiography(3D-STE). Results: Global longitudinal strain (GLS), and global radial strain (GRS) were reduced in BAV-nf patients compared with the controls. With each categorical of AS severity from BAV-nf to severe AS, there was an associated progressive impairment of GLS and GRS (all P < 0.001). Global circumferential strain (GCS) did not show a significant decrease from BAV-nf to mild AS but began to decrease from moderate AS. Multiple linear regressions indicated that indexed aortic valve area (AVA/BSA), as a measure of AS severity, was an independent determinant of GLS, GCS and GRS. Conclusions: Left ventricular longitudinal myocardial reduction is observed even in patients with well-functioning bicuspid aortic valves. With each categorical increase in the grade of AS severity from normally functioning to severe aortic stenosis, there was an associated progressive impairment of longitudinal myocardial function. Furthermore, circumferential myocardial function was starting damaged from moderate AS. AVA/BSA was independently associated with multidirectional myocardial function injuries.

4.
Front Cardiovasc Med ; 11: 1417757, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39161660

RESUMEN

Background and aims: Transcatheter tricuspid valve replacement (TTVR) has recently emerged as a novel therapeutic approach for managing severe tricuspid regurgitation (TR). However, surgical tricuspid valve replacement (STVR) continues to be the predominant treatment modality. There are limited comparative data on both procedures. This study aimed to compare clinical and echocardiographic outcomes between patients who underwent mini-thoracotomy transatrial LuX-Valve TTVR and those who underwent STVR. Methods: This study prospectively collected patients with severe TR who underwent TTVR (n = 29) or isolated STVR (n = 59) at Wuhan Union Hospital from 2019 to 2022. All TTVR patients received the LuX-Valve via a mini-thoracotomy and transatrial approach. The clinical and echocardiographic outcomes were compared at 30-day and one-year follow-ups. Results: At baseline, patients with LuX-Valve TTVR had higher surgical risk scores and a greater proportion of right ventricular dysfunction compared with STVR. In the early postoperative period, the STVR group had a greater decrease in right ventricular function. Hospital length of stay (LOS), intensive care unit LOS, total procedure time, and tracheal intubation time were shorter in the TTVR than in the STVR group. The incidence of postoperative paravalvular leaks was higher among patients who underwent TTVR. Compared to the STVR group, the pacemaker implantation rate was lower in the TTVR group. During follow-up, the peak tricuspid valve velocity and mean gradient in the TTVR group were consistently lower than those in the STVR group. There was similar mortality between TTVR and STVR at 30-day and one-year follow-ups. Conclusions: The mini-thoracotomy transatria LuX-Valve TTVR has a higher incidence of paravalvular leaks and a lower rate of pacemaker implantation than STVR, with similar 30-day and one-year mortality rates. In some respects, mini-thoracotomy transatrial LuX-Valve TTVR may be a feasible and safe treatment option for specific populations, or it could potentially serve as an alternative therapy to supplement conventional STVR. Further follow-up is required to assess differences in long-term clinical outcomes and valve durability.

6.
Echocardiography ; 41(8): e15886, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-39007877

RESUMEN

BACKGROUND: Due to insufficient near-field resolution and artifacts, it is challenging to evaluate the left ventricular apical perfusion with phased-array probes. By combining high-frequency linear probe and contrast-enhanced ultrasound (CEUS), imaging of apical myocardial perfusion could be improved. The study aims to evaluate the preliminary application of CEUS by high-frequency linear probes to assess the apical perfusion. METHODS: The study enrolled retrospectively 91 patients to test the feasibility of the novel method. In protocol 1, patients were stratified into a group with left anterior descending artery (LAD) stenosis (N = 40) and a group without LAD stenosis or coronary artery disease (N = 41) based on the degree of coronary artery narrowing, quantified by >50% stenosis in coronary angiography. Receiver operating characteristics (ROC) analysis was performed to test the diagnostic value of perfusion parameters. In protocol 2, the reproducibility of high-frequency linear probe in apical perfusion analysis was compared with the conventional phased-array probe in 30 patients. RESULTS: (1) The novel method is feasible in 81(89.01%) patients. (2) In protocol 1, to detect LAD stenosis, the best cut-off of ß, T, A, and MBF were 10.32, 3.28, 9.39, and 4.99, respectively. Area under the curve of ß, T, A, and MBF were .880, .881, .761, and .880, respectively. (3) In protocol 2, compared with phased-array probe, the quantitative analysis of high-frequency linear probe is of high reproducibility and could get good curve fitting (R2 = .29 vs. R2 = .71, P < .01). CONCLUSION: Observation of apical perfusion using this method is feasible and quantitative analysis allows an accurate and convenient identification of LAD stenosis. This method provides an alternative for patients who have difficulties in visualizing the apical region with a phased-array probe.


Asunto(s)
Medios de Contraste , Estudios de Factibilidad , Humanos , Masculino , Femenino , Reproducibilidad de los Resultados , Estudios Retrospectivos , Persona de Mediana Edad , Imagen de Perfusión Miocárdica/métodos , Ecocardiografía/métodos , Aumento de la Imagen/métodos , Anciano , Sensibilidad y Especificidad , Ventrículos Cardíacos/diagnóstico por imagen , Ventrículos Cardíacos/fisiopatología , Estenosis Coronaria/fisiopatología , Estenosis Coronaria/diagnóstico por imagen , Diseño de Equipo
8.
Chin Med J (Engl) ; 137(15): 1802-1810, 2024 Aug 05.
Artículo en Inglés | MEDLINE | ID: mdl-38958034

RESUMEN

BACKGROUND: Carotid intima-media thickness (IMT) and diameter, stiffness, and wave reflections, are independent and important clinical biomarkers and risk predictors for cardiovascular diseases. The purpose of the present study was to establish nationwide reference values of carotid properties for healthy Chinese adults and to explore potential clinical determinants. METHODS: A total of 3053 healthy Han Chinese adults (1922 women) aged 18-79 years were enrolled at 28 collaborating tertiary centers throughout China between April 2021 and July 2022. The real-time tracking of common carotid artery walls was achieved by the radio frequency (RF) ultrasound system. The IMT, diameter, compliance coefficient, ß stiffness, local pulse wave velocity (PWV), local systolic blood pressure, augmented pressure (AP), and augmentation index (AIx) were then automatically measured and reported. Data were stratified by age groups and sex. The relationships between age and carotid property parameters were analyzed by Jonckheere-Terpstra test and simple linear regressions. The major clinical determinants of carotid properties were identified by Pearson's correlation, multiple linear regression, and analyses of covariance. RESULTS: All the parameters of carotid properties demonstrated significantly age-related trajectories. Women showed thinner IMT, smaller carotid diameter, larger AP, and AIx than men. The ß stiffness and PWV were significantly higher in men than women before forties, but the differences reversed after that. The increase rate of carotid IMT (5.5 µm/year in women and 5.8 µm/year in men) and diameter (0.03 mm/year in both men and women) were similar between men and women. For the stiffness and wave reflections, women showed significantly larger age-related variations than men as demonstrated by steeper regression slopes (all P for age by sex interaction <0.05). The blood pressures, body mass index (BMI), and triglyceride levels were identified as major clinical determinants of carotid properties with adjustment of age and sex. CONCLUSIONS: The age- and sex-specific reference values of carotid properties measured by RF ultrasound for healthy Chinese adults were established. The blood pressures, BMI, and triglyceride levels should be considered for clinical application of corresponding reference values.


Asunto(s)
Grosor Intima-Media Carotídeo , Análisis de la Onda del Pulso , Rigidez Vascular , Humanos , Adulto , Persona de Mediana Edad , Masculino , Femenino , Anciano , Adulto Joven , Rigidez Vascular/fisiología , Adolescente , Valores de Referencia , China , Ultrasonografía/métodos , Pueblo Asiatico , Arterias Carótidas/diagnóstico por imagen , Pueblos del Este de Asia
10.
Front Cardiovasc Med ; 11: 1410594, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39006165

RESUMEN

Transesophageal Echocardiography (TEE) is an important imaging method for the evaluation of cardiac structure and function, and it holds significant value in the clinical management of cardiovascular diseases. Unlike transthoracic echocardiography (TTE), which is non-invasive, TEE involves semi-invasive intracavity operations, leading to increasing attention to its safety and potential complications. Especially with the increasing demand for TEE applications in clinical practice and the rapid growth in the number of facilities utilizing it, the standardized application and safe operation of TEE technology have become particularly crucial. This article will review the literature and draw upon personal experience to analyze the complications and safety of TEE examinations from a technical perspective.

12.
Digit Health ; 10: 20552076241260557, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38882253

RESUMEN

Background: Left ventricular opacification (LVO) improves the accuracy of left ventricular ejection fraction (LVEF) by enhancing the visualization of the endocardium. Manual delineation of the endocardium by sonographers has observer variability. Artificial intelligence (AI) has the potential to improve the reproducibility of LVO to assess LVEF. Objectives: The aim was to develop an AI model and evaluate the feasibility and reproducibility of LVO in the assessment of LVEF. Methods: This retrospective study included 1305 echocardiography of 797 patients who had LVO at the Department of Ultrasound Medicine, Union Hospital, Huazhong University of Science and Technology from 2013 to 2021. The AI model was developed by 5-fold cross validation. The validation datasets included 50 patients prospectively collected in our center and 42 patients retrospectively collected in the external institution. To evaluate the differences between LV function determined by AI and sonographers, the median absolute error (MAE), spearman correlation coefficient, and intraclass correlation coefficient (ICC) were calculated. Results: In LVO, the MAE of LVEF between AI and manual measurements was 2.6% in the development cohort, 2.5% in the internal validation cohort, and 2.7% in the external validation cohort. Compared with two-dimensional echocardiography (2DE), the left ventricular (LV) volumes and LVEF of LVO measured by AI correlated significantly with manual measurements. AI model provided excellent reliability for the LV parameters of LVO (ICC > 0.95). Conclusions: AI-assisted LVO enables more accurate identification of the LV endocardium and reduces observer variability, providing a more reliable way for assessing LV function.

13.
J Thorac Dis ; 16(5): 3117-3128, 2024 May 31.
Artículo en Inglés | MEDLINE | ID: mdl-38883679

RESUMEN

Background: Left atrioventricular valvular regurgitation (LAVVR) recurrence after partial and transitional atrioventricular septal defect (AVSD) repair is the main risk factor associated with reoperation or mortality. The purpose of this study was to identify risk factors associated with the recurrence of LAVVR after surgical repair of transitional and partial AVSD at a single institution. Methods: A hundred and fifty-seven patients who underwent anatomical repair for partial and transitional AVSD from January 2013 to December 2021 were included in our institutional database. Demographic characteristics, operative information, comorbidities, complications, and outcomes were retrieved from electronic medical records. Echocardiographic evaluations included cardiac dimensions, the degree of LAVVR, and the anatomy of the atrioventricular valve. Results: After a median follow-up period of 5.8 years, 40 patients had recurrent moderate or even more severe LAVVR. Compared with patients without recurrent LAVVR, those experiencing LAVVR recurrence were more likely to have larger preoperative left atrial (LA) size and larger left ventricular (LV) size after standardization, larger left atrioventricular valve (LAVV) cleft width, higher proportions of preoperative moderate or even more severe LAVVR, and immediately postoperative mild to moderate or even more severe LAVVR. Univariate Cox regression analysis showed that age at first repair, height, LA size after standardization, LV size after standardization, the severity of preoperative LAVVR, immediately postoperative LAVVR, and the LAVV cleft width more than 1cm were risk factors for recurrent LAVVR (P<0.05 for all). Multivariable Cox regression analysis showed that mild to moderate or even more severe LAVVR postoperatively [hazard ratio (HR) 9.53, 95% confidence interval (CI): 3.78-24.01; P<0.001], the width of LAVV cleft more than 1 cm (HR: 3.90, 95% CI: 1.80-8.48; P<0.001) and age at first repair (HR: 0.45, 95% CI: 0.31-0.66; P<0.001) were independently associated with the recurrence of LAVVR. Conclusions: The width of LAVV cleft, mild to moderate or even more severe LAVVR immediately after surgery, and age at initial surgery are risk factors for recurrent LAVVR. The presence of recurrent LAVVR necessitates proactive surveillance to facilitate timely reintervention.

14.
Diagnostics (Basel) ; 14(12)2024 Jun 16.
Artículo en Inglés | MEDLINE | ID: mdl-38928685

RESUMEN

As an integral part of the mitral valve apparatus, the left ventricle papillary muscle (PM) controls mitral valve closure during systole and participates in the ejection process during left ventricular systole. Mitral regurgitation (MR) is the most immediate and predominant result when the PM is structurally or functionally abnormal. However, dysfunction of the PM is easily underestimated or overlooked in clinical interventions for MR-related diseases. Therefore, adequate recognition of PM dysfunction and PM-derived MR is critical. In this review, we systematically describe the normal anatomical variations in the PM and the pathophysiology of PM dysfunction-related diseases and summarize the commonly used parameters and the advantages and disadvantages of various noninvasive imaging modalities for the structural and functional assessment of the PM.

15.
Diagnostics (Basel) ; 14(12)2024 Jun 20.
Artículo en Inglés | MEDLINE | ID: mdl-38928720

RESUMEN

Heart transplantation (HT) is the mainstream therapy for end-stage heart disease. However, the cardiac graft function can be affected by several factors. It is important to monitor HT patients for signs of graft dysfunction. Transthoracic echocardiography is a simple, first-line, and non-invasive method for the assessment of cardiac function. The emerging speckle-tracking echocardiography (STE) could quickly and easily provide additive information over traditional echocardiography. STE longitudinal deformation parameters are markers of early impairment of ventricular function. Although once called the "forgotten ventricle", right ventricular (RV) assessment has gained attention in recent years. This review highlights the potentially favorable role of STE in assessing RV systolic function in clinically well HT patients.

19.
Adv Sci (Weinh) ; 11(26): e2309907, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38696589

RESUMEN

Myocardial ischemia/reperfusion injury (MIRI) is the leading cause of irreversible myocardial damage. A pivotal pathogenic factor is ischemia/reperfusion (I/R)-induced cardiomyocyte ferroptosis, marked by iron overload and lipid peroxidation. However, the impact of lipid droplet (LD) changes on I/R-induced cardiomyocyte ferroptosis is unclear. In this study, an aggregation-induced emission probe, TPABTBP is developed that is used for imaging dynamic changes in LD during myocardial I/R-induced ferroptosis. TPABTBP exhibits excellent LD-specificity, superior capability for monitoring lipophagy, and remarkable photostability. Molecular dynamics (MD) simulation and super-resolution fluorescence imaging demonstrate that the TPABTBP is specifically localized to the phospholipid monolayer membrane of LDs. Imaging LDs in cardiomyocytes and myocardial tissue in model mice with MIRI reveals that the LD accumulation level increase in the early reperfusion stage (0-9 h) but decrease in the late reperfusion stage (>24 h) via lipophagy. The inhibition of LD breakdown significantly reduces the lipid peroxidation level in cardiomyocytes. Furthermore, it is demonstrated that chloroquine (CQ), an FDA-approved autophagy modulator, can inhibit ferroptosis, thereby attenuating MIRI in mice. This study describes the dynamic changes in LD during myocardial ischemia injury and suggests a potential therapeutic target for early MIRI intervention.


Asunto(s)
Modelos Animales de Enfermedad , Ferroptosis , Gotas Lipídicas , Daño por Reperfusión Miocárdica , Miocitos Cardíacos , Animales , Ratones , Miocitos Cardíacos/metabolismo , Daño por Reperfusión Miocárdica/metabolismo , Gotas Lipídicas/metabolismo , Masculino , Simulación de Dinámica Molecular , Peroxidación de Lípido
20.
World J Urol ; 42(1): 302, 2024 May 08.
Artículo en Inglés | MEDLINE | ID: mdl-38720010

RESUMEN

PURPOSE: To evaluate the diagnostic performance of contrast-enhanced (CE) ultrasound using Sonazoid (SNZ-CEUS) by comparing with contrast-enhanced computed tomography (CE-CT) and contrast-enhanced magnetic resonance imaging (CE-MRI) for differentiating benign and malignant renal masses. MATERIALS AND METHODS: 306 consecutive patients (from 7 centers) with renal masses (40 benign tumors, 266 malignant tumors) diagnosed by both SNZ-CEUS, CE-CT or CE-MRI were enrolled between September 2020 and February 2021. The examinations were performed within 7 days, but the sequence was not fixed. Histologic results were available for 301 of 306 (98.37%) lesions and 5 lesions were considered benign after at least 2 year follow-up without change in size and image characteristics. The diagnostic performances were evaluated by sensitivity, specificity, positive predictive value, negative predictive value, and compared by McNemar's test. RESULTS: In the head-to-head comparison, SNZ-CEUS and CE-MRI had comparable sensitivity (95.60 vs. 94.51%, P = 0.997), specificity (65.22 vs. 73.91%, P = 0.752), positive predictive value (91.58 vs. 93.48%) and negative predictive value (78.95 vs. 77.27%); SNZ-CEUS and CE-CT showed similar sensitivity (97.31 vs. 96.24%, P = 0.724); however, SNZ-CEUS had relatively lower than specificity than CE-CT (59.09 vs. 68.18%, P = 0.683). For nodules > 4 cm, CE-MRI demonstrated higher specificity than SNZ-CEUS (90.91 vs. 72.73%, P = 0.617) without compromise the sensitivity. CONCLUSIONS: SNZ-CEUS, CE-CT, and CE-MRI demonstrate desirable and comparable sensitivity for the differentiation of renal mass. However, the specificity of all three imaging modalities is not satisfactory. SNZ-CEUS may be a suitable alternative modality for patients with renal dysfunction and those allergic to gadolinium or iodine-based agents.


Asunto(s)
Medios de Contraste , Compuestos Férricos , Hierro , Neoplasias Renales , Imagen por Resonancia Magnética , Óxidos , Tomografía Computarizada por Rayos X , Ultrasonografía , Humanos , Neoplasias Renales/diagnóstico por imagen , Neoplasias Renales/patología , Masculino , Femenino , Persona de Mediana Edad , Estudios Prospectivos , Ultrasonografía/métodos , Tomografía Computarizada por Rayos X/métodos , Imagen por Resonancia Magnética/métodos , Anciano , Diagnóstico Diferencial , Adulto , Anciano de 80 o más Años
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...