Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 21
Filtrar
1.
Lab Med ; 54(1): 56-64, 2023 Jan 05.
Artículo en Inglés | MEDLINE | ID: mdl-35849098

RESUMEN

OBJECTIVE: To evaluate the accuracy of the reverse transcription loop-mediated isothermal amplification (RT-LAMP) assay for rapid detection of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) in community or primary-care settings. METHOD: We systematically searched the Web of Science, Embase, PubMed, and Cochrane Library databases. We conducted quality evaluation using ReviewManager software (version 5.0). We then used MetaDisc software (version 1.4) and Stata software (version 12.0) to build forest plots, along with a Deeks funnel plot and a bivariate boxplot for analysis. RESULT: Overall, the sensitivity, specificity, and diagnostic odds ratio were 0.79, 0.97, and 328.18, respectively. The sensitivity for the subgroup with RNA extraction appeared to be higher, at 0.88 (0.86-0.90), compared to the subgroup without RNA extraction, at 0.50 (0.45-0.55), with no significant difference in specificity. CONCLUSION: RT-LAMP assay exhibited high specificity regarding current SARS-CoV-2 infection. However, its overall sensitivity was relatively moderate. Extracting RNA was found to be beneficial in improving sensitivity.


Asunto(s)
COVID-19 , SARS-CoV-2 , Humanos , SARS-CoV-2/genética , COVID-19/diagnóstico , Prueba de COVID-19 , Técnicas de Laboratorio Clínico , Sensibilidad y Especificidad , Técnicas de Diagnóstico Molecular , Técnicas de Amplificación de Ácido Nucleico , ARN Viral/genética
2.
Yonsei Med J ; 63(5): 480-489, 2022 May.
Artículo en Inglés | MEDLINE | ID: mdl-35512751

RESUMEN

PURPOSE: Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is the pathogen of coronavirus disease 2019. Diagnostic methods based on the clustered regularly interspaced short palindromic repeats (CRISPR) have been developed to detect SARS-CoV-2 rapidly. Therefore, a systematic review and meta-analysis were performed to assess the diagnostic accuracy of CRISPR for detecting SARS-CoV-2 infection. MATERIALS AND METHODS: Studies published before August 2021 were retrieved from four databases, using the keywords "SARS-CoV-2" and "CRISPR." Data were collected from these publications, and the sensitivity, specificity, negative likelihood ratio (NLR), positive likelihood ratio (PLR), and diagnostic odds ratio (DOR) were calculated. The summary receiver operating characteristic curve was plotted for analysis with MetaDiSc 1.4. The Stata 15.0 software was used to draw Deeks' funnel plots to evaluate publication bias. RESULTS: We performed a pooled analysis of 38 independent studies shown in 30 publications. The reference standard was reverse transcription-quantitative PCR. The results indicated that the sensitivity of CRISPR-based methods for diagnosis was 0.94 (95% CI 0.93-0.95), the specificity was 0.98 (95% CI 0.97-0.99), the PLR was 34.03 (95% CI 20.81-55.66), the NLR was 0.08 (95% CI 0.06-0.10), and the DOR was 575.74 (95% CI 382.36-866.95). The area under the curve was 0.9894. CONCLUSION: Studies indicate that a diagnostic method based on CRISPR has high sensitivity and specificity. Therefore, this would be a potential diagnostic tool to improve the accuracy of SARS-CoV-2 detection.


Asunto(s)
COVID-19 , SARS-CoV-2 , COVID-19/diagnóstico , Humanos , Curva ROC , Estándares de Referencia , SARS-CoV-2/genética , Sensibilidad y Especificidad
3.
Biomark Med ; 16(3): 197-216, 2022 02.
Artículo en Inglés | MEDLINE | ID: mdl-35112920

RESUMEN

Aim: CYFRA21-1 is a biomarker of cancer and has a promising future in the diagnosis of bladder cancer. The purpose of this study was to assess the diagnostic accuracy of CYFRA21-1 for bladder cancer. Methods: We included articles from the Cochrane Library, Web of Science, PubMed and Embase. Meta-DiSc 1.4 and Stata 12.0 were used for data analysis. Results: Twenty-eight articles were analyzed, and the results are as follows: sensitivity, specificity, PLR, NLR, DOR and AUC were 0.69 (95% CI [0.67, 0.71]), 0.81 (95% CI [0.80, 0.83]), 5.99 (95% CI [4.42, 8.11]), 0.31 (95% CI [0.25, 0.38]), 24.58 (95% CI [15.15, 39.89]) and 0.8917, respectively. Conclusion: CYFRA21-1 has a high diagnostic efficiency for bladder cancer.


Asunto(s)
Queratina-19 , Neoplasias de la Vejiga Urinaria , Antígenos de Neoplasias , Humanos , Neoplasias de la Vejiga Urinaria/diagnóstico
4.
Jpn J Infect Dis ; 75(2): 183-191, 2022 Mar 24.
Artículo en Inglés | MEDLINE | ID: mdl-34053954

RESUMEN

Xpert Xpress Flu/RSV is a fast and automated real-time nucleic acid amplification tool for detecting influenza virus and respiratory syncytial virus (RSV). The aim of this study was to verify the accuracy of Xpert Xpress Flu/RSV for detecting influenza virus and RSV. PubMed, EMBASE, Cochrane Library, and Web of Science databases were searched up to October 2020. The quality of the original research was assessed using the Quality Assessment of Diagnostic Accuracy Studies-2 guidelines. Meta-DiSc 1.4 software was used to analyze the sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, diagnostic odds ratio, and summary receiver operating characteristic curve. Deek's funnel plot asymmetry test was used to evaluate the publication bias using the Stata 12.0 software. Ten studies with 25 fourfold tables were included in the analysis. The sensitivity of Xpert Xpress Flu/RSV for detecting influenza A, influenza B, and RSV were 0.97, 0.98, and 0.96, respectively, and the specificities were 0.97, 1.00, and 1.00, respectively. Compared with other common clinical real-time reverse transcription-polymerase chain reaction (RT-PCR), Xpert Xpress Flu/RSV is a valuable tool for diagnosing influenza virus and RSV with high sensitivity and specificity.


Asunto(s)
Virus de la Influenza A , Gripe Humana , Infecciones por Virus Sincitial Respiratorio , Virus Sincitial Respiratorio Humano , Humanos , Virus de la Influenza A/genética , Virus de la Influenza B/genética , Gripe Humana/diagnóstico , Técnicas de Diagnóstico Molecular , Nasofaringe , Infecciones por Virus Sincitial Respiratorio/diagnóstico , Virus Sincitial Respiratorio Humano/genética , Sensibilidad y Especificidad
5.
Biochem Genet ; 60(3): 1076-1094, 2022 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-34787756

RESUMEN

COVID-19 is a serious infectious disease that has recently swept the world, and research on its causative virus, SARS-CoV-2, remains insufficient. Therefore, this study uses bioinformatics analysis techniques to explore the human digestive tract diseases that may be caused by SARS-CoV-2 infection. The gene expression profile data set, numbered GSE149312, is from the Gene Expression Omnibus (GEO) database and is divided into a 24-h group and a 60-h group. R software is used to analyze and screen out differentially expressed genes (DEGs) and then gene ontology (GO) term and Kyoto Encyclopedia of Genes and Genomes (KEGG) pathway enrichment analyses are performed. In KEGG, the pathway of non-alcoholic fatty liver disease exists in both the 24-h group and 60-h group. STRING is used to establish a protein-protein interaction (PPI) network, and Cytoscape is then used to visualize the PPI and define the top 12 genes of the node as the hub genes. Through verification, nine statistically significant hub genes are identified: AKT1, TIMP1, NOTCH, CCNA2, RRM2, TTK, BUB1B, KIF20A, and PLK1. In conclusion, the results of this study can provide a certain direction and basis for follow-up studies of SARS-CoV-2 infection of the human digestive tract and provide new insights for the prevention and treatment of diseases caused by SARS-CoV-2.


Asunto(s)
COVID-19 , Biología Computacional , COVID-19/genética , Biología Computacional/métodos , Perfilación de la Expresión Génica/métodos , Humanos , Intestinos , SARS-CoV-2/genética
6.
Yonsei Med J ; 63(1): 95-103, 2022 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-34913289

RESUMEN

PURPOSE: Acute respiratory viral infections pose significant morbidity and mortality, making it essential to diagnose respiratory viral infections rapidly. In this study, the diagnostic efficacy of the Luminex xTAG Respiratory Virus Panel (RVP) FAST v2 test was evaluated on respiratory viral infections. MATERIALS AND METHODS: Information was retrieved from electronic databases, including Embase, Web of Science, PubMed, and Cochrane Library, for systematic review. Studies that fulfilled predefined inclusion criteria were included. After the extraction of information, statistical software was utilized for quality evaluation, data analysis, and assessment of publication bias. RESULTS: Eighty groups in fourfold tables from nine articles were included to perform statistical analyses. Therein, the mean specificity and mean sensitivity of Luminex xTAG RVP FAST v2 test for the detection of respiratory viral infections were 0.99 (0.98-0.99) and 0.88 (0.87-0.90), respectively. Additionally, the negative and positive likelihood ratios were 0.14 (0.11-0.19) and 87.42 (61.88-123.50), respectively. Moreover, the diagnostic odds ratio and area under the curve of summary receiver operating characteristic were 714.80 and 0.9886, respectively. CONCLUSION: The Luminex xTAG RVP FAST v2 test could be a reliable and rapid diagnostic method for multiple respiratory viral infections.


Asunto(s)
Infecciones del Sistema Respiratorio , Virosis , Virus , Humanos , Sistema Respiratorio , Infecciones del Sistema Respiratorio/diagnóstico , Sensibilidad y Especificidad , Virosis/diagnóstico
7.
Eur J Med Res ; 26(1): 146, 2021 Dec 17.
Artículo en Inglés | MEDLINE | ID: mdl-34920753

RESUMEN

BACKGROUND: At the end of 2019, the world witnessed the emergence and ravages of a viral infection induced by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). Also known as the coronavirus disease 2019 (COVID-19), it has been identified as a public health emergency of international concern (PHEIC) by the World Health Organization (WHO) because of its severity. METHODS: The gene data of 51 samples were extracted from the GSE150316 and GSE147507 data set and then processed by means of the programming language R, through which the differentially expressed genes (DEGs) that meet the standards were screened. The Gene Ontology (GO) and Kyoto Encyclopedia of Genes and Genomes (KEGG) analyses were performed on the selected DEGs to understand the functions and approaches of DEGs. The online tool STRING was employed to construct a protein-protein interaction (PPI) network of DEGs and, in turn, to identify hub genes. RESULTS: A total of 52 intersection genes were obtained through DEG identification. Through the GO analysis, we realized that the biological processes (BPs) that have the deepest impact on the human body after SARS-CoV-2 infection are various immune responses. By using STRING to construct a PPI network, 10 hub genes were identified, including IFIH1, DDX58, ISG15, EGR1, OASL, SAMD9, SAMD9L, XAF1, IFITM1, and TNFSF10. CONCLUSION: The results of this study will hopefully provide guidance for future studies on the pathophysiological mechanism of SARS-CoV-2 infection.


Asunto(s)
COVID-19/genética , Biología Computacional/métodos , Regulación de la Expresión Génica/genética , Pulmón/patología , Mapas de Interacción de Proteínas/genética , COVID-19/patología , Bases de Datos Genéticas , Perfilación de la Expresión Génica , Ontología de Genes , Humanos , Inmunidad Humoral/genética , Inmunidad Humoral/inmunología , Pulmón/virología , Activación Neutrófila/genética , Activación Neutrófila/inmunología , Neutrófilos/inmunología , SARS-CoV-2 , Transcriptoma/genética
8.
Ann Clin Microbiol Antimicrob ; 20(1): 62, 2021 Sep 06.
Artículo en Inglés | MEDLINE | ID: mdl-34488790

RESUMEN

BACKGROUND: Group B Streptococcal (GBS) infection is the primary agent of neonatal morbidity and mortality. Rapid and simple methods to detect GBS are Xpert GBS and GBS LB assays based on real-time polymerase chain reaction (PCR). However, since the diagnostic accuracy of the two techniques in diagnosing GBS remains unclear, we designed this study to appraise the diagnostic accuracy of the aforementioned. METHODS: A systematic search of all literature published before July 16, 2020 was conducted using Embase, PubMed, Web of Science, and Cochrane Library. The study quality was evaluated through Review Manager 5.3. Accordingly, data extracted in the included studies were analyzed using Meta-DiSc 1.4 and Stata 12.0 software. The diagnosis odds ratio (DOR) and bivariate boxplot were utilized to evaluate the heterogeneity. Publication bias was appraised by using Deeks' funnel plot. RESULTS: A total of 13 studies were adopted and only 19 sets of data met the criteria. The sensitivity and specificity of Xpert GBS were 0.91 (95% CI 0.89-0.92) and 0.93 (95% CI 0.92-0.94). The area under the curve (AUC) was 0.9806. The sensitivity and specificity results of Xpert GBS LB were 0.96 (95% CI 0.95-0.98) and 0.94 (95% CI 0.92-0.95), respectively. The AUC was 0.9950. No publication bias was found. CONCLUSIONS: The Xpert GBS and GBS LB assays are valuable alternative methods with high sensitivity and specificity. However, determining whether they can be used as clinical diagnostic standards for GBS is essential for the future.


Asunto(s)
Técnicas Bacteriológicas/métodos , Técnicas de Diagnóstico Molecular/métodos , Reacción en Cadena en Tiempo Real de la Polimerasa/normas , Infecciones Estreptocócicas/diagnóstico , Streptococcus agalactiae/aislamiento & purificación , Humanos , Recién Nacido , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Infecciones Estreptocócicas/microbiología , Streptococcus agalactiae/genética
9.
Biomed Res Int ; 2021: 5527505, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34055977

RESUMEN

BACKGROUND: West Africa has witnessed the unprecedented outbreak of Ebola virus disease (EVD). The Ebola virus (EBOV) can cause Ebola hemorrhagic fever, which is documented as the most deadly viral hemorrhagic fever in the world. RT-PCR had been suggested to be employed in the detection of Ebola virus; however, this method has high requirements for laboratory equipment and takes a long time to determine Ebola infection. Although Xpert Ebola is a fast and simple instrument for the detection of Ebola virus, its effect is still unclear. This study is aimed at evaluating the accuracy of Xpert Ebola in diagnosing Ebola virus infection. METHODS: Using the keywords "Xpert" and "Ebola virus", relevant studies were retrieved from the database of PubMed, Embase, Web of Science, and Cochrane. RT-PCR was employed as a reference standard to evaluate whether the study is eligible to be included in the meta-analysis. Data from these included studies were extracted by two independent assessors and were then analyzed by the Meta-DiSc 1.4 software to produce the heterogeneity of sensitivity (SEN), specificity (SP), positive likelihood ratio (PLR), negative likelihood ratio (NLR), and diagnostic advantage ratio (DOR) of the study. The results of pooled analysis were plotted, together with the summary receiver operating characteristic (SROC) curve plotted by calculating the area under the curve (AUC). Generated pooled summary estimates (95% CIs) were calculated for the evaluation of the overall accuracy of this study. RESULTS: Five fourfold tables were made from the four studies that were included in the meta-analysis. The pooled sensitivity of Xpert Ebola was 0.98 (95% confidence interval (CI) (0.95, 0.99)), and the pooled specificity was 0.98 (95% CI (0.97, 0.99)). The pooled values of positive likelihood ratio was 53.91 (95% CI (12.82, 226.79)), with negative likelihood ratio being 0.04 (95% CI (0.02, 0.08)) and diagnostic odds ratio being 2649.45 (95% CI (629.61, 11149.02)). The AUC was 0.9961. CONCLUSIONS: Compared with RT-PCR, Xpert Ebola has high sensitivity and specificity. Therefore, it is a valued alternative method for the clinical diagnosis of Ebola virus infection. However, the Xpert Ebola test is a qualitative test that does not provide quantitative testing of EBOV concentration. Whether it can completely replace other methods or not calls for further evidences.


Asunto(s)
Ebolavirus/aislamiento & purificación , Fiebre Hemorrágica Ebola/diagnóstico , Técnicas de Diagnóstico Molecular/métodos , África Occidental , Animales , Área Bajo la Curva , Bases de Datos Factuales , Humanos , Oportunidad Relativa , Curva ROC , Estándares de Referencia , Sensibilidad y Especificidad
10.
Biomed Res Int ; 2021: 6614812, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33928150

RESUMEN

INTRODUCTION: High mortality associated with carbapenemase-producing Gram-negative bacteria (CP-GNB) has evolved into a global health threat. Rapid and accurate detection as well as prompt treatment are of great significance in this case. Xpert Carba-R, a multiple qualitative analysis designed to detect five clinically relevant carbapenem-resistant gene families within one hour, is regarded as reliable, accurate, and easy-to-operate. This study is to present a systematic evaluation of the performance of Xpert Carba-R in detecting carbapenemase genes in GNB suspected for carbapenemase production. METHODS: We searched and screened the literature on "Xpert Carba-R" in the database of PubMed, Web of Science, Embase, and Cochrane Library, employing two independent evaluators to collect data, respectively. Then, statistical analysis of the data obtained was performed by the Stata 12.0 software to measure the accuracy of Xpert Carba-R assay in detecting the carbapenemase genes in GNB. RESULTS: We screened a total of 1767 Gram-negative bacillus isolates documented in 9 articles. The precision of the detection of OXA-48 carbapenemase genes was 100%; that of NDM = 100%; that of VIM = 100%. When it came to KPC, the precision rate was 100%; that of IMP = 99%. The overall accuracy of the detection of carbapenemase genes was 100%. CONCLUSIONS: Xpert Carba-R assay demonstrates a 100% precision in identifying carbapenemase genes in GNB. It can be seen that Xpert Carba-R method is an effective tool for early clinical detection, which is suitable for the detection of carbapenase gene in GNB.


Asunto(s)
Proteínas Bacterianas/genética , Pruebas de Enzimas/métodos , Bacterias Gramnegativas/enzimología , Bacterias Gramnegativas/genética , beta-Lactamasas/genética , Bacterias Gramnegativas/aislamiento & purificación , Humanos , Sesgo de Publicación , Especificidad de la Especie
11.
Hum Genomics ; 15(1): 18, 2021 03 16.
Artículo en Inglés | MEDLINE | ID: mdl-33726831

RESUMEN

BACKGROUND: In the novel coronavirus pandemic, the high infection rate and high mortality have seriously affected people's health and social order. To better explore the infection mechanism and treatment, the three-dimensional structure of human bronchus has been employed in a better in-depth study on severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). METHODS: We downloaded a separate microarray from the Integrated Gene Expression System (GEO) on a human bronchial organoids sample to identify differentially expressed genes (DEGS) and analyzed it with R software. After processing with R software, Gene Ontology (GO) and Kyoto PBMCs of Genes and Genomes (KEGG) were analyzed, while a protein-protein interaction (PPI) network was constructed to show the interactions and influence relationships between these differential genes. Finally, the selected highly connected genes, which are called hub genes, were verified in CytoHubba plug-in. RESULTS: In this study, a total of 966 differentially expressed genes, including 490 upregulated genes and 476 downregulated genes were used. Analysis of GO and KEGG revealed that these differentially expressed genes were significantly enriched in pathways related to immune response and cytokines. We construct protein-protein interaction network and identify 10 hub genes, including IL6, MMP9, IL1B, CXCL8, ICAM1, FGF2, EGF, CXCL10, CCL2, CCL5, CXCL1, and FN1. Finally, with the help of GSE150728, we verified that CXCl1, CXCL8, CXCL10, CCL5, EGF differently expressed before and after SARS-CoV-2 infection in clinical patients. CONCLUSIONS: In this study, we used mRNA expression data from GSE150819 to preliminarily confirm the feasibility of hBO as an in vitro model to further study the pathogenesis and potential treatment of COVID-19. Moreover, based on the mRNA differentiated expression of this model, we found that CXCL8, CXCL10, and EGF are hub genes in the process of SARS-COV-2 infection, and we emphasized their key roles in SARS-CoV-2 infection. And we also suggested that further study of these hub genes may be beneficial to treatment, prognostic prediction of COVID-19.


Asunto(s)
Bronquios/virología , COVID-19/genética , Regulación de la Expresión Génica , Bronquios/fisiología , Quimiocina CXCL10/genética , Factor de Crecimiento Epidérmico/genética , Interacciones Huésped-Patógeno/genética , Humanos , Interleucina-8/genética , Organoides , Mapas de Interacción de Proteínas/genética , Programas Informáticos
12.
Biomed Res Int ; 2020: 2892734, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-33102576

RESUMEN

BACKGROUND: Chlamydia trachomatis (CT) and Neisseria gonorrhoeae (NG) are widely spread across the world. Asymptomatic or inconspicuous CT/NG infections are difficult to diagnose and treat. Traditional methods have the disadvantages of low detection rate, inaccurate results, and long detection time. However, Xpert CT/NG makes up for the aforementioned shortcomings and has research value and popularization significance. METHODS: PubMed, Embase, Cochrane Library, and Web of Science were systematically searched, and studies were screened using Xpert CT/NG for diagnosing CT/NG. QUADAS-2 was used to evaluate the quality of the eligible studies. Then, two groups of researchers independently extracted data from these studies. Meta-analyses of sensitivity (SEN), specificity (SPE), positive likelihood ratio (PLR), negative likelihood ratio (NLR), diagnostic odds ratio (DOR), and the area under the curve (AUC) of the summary receiver operating characteristic (SROC) curve were conducted using Meta-DiSc 1.4. Finally, Deek's funnel plots were made using Stata 12.0 to evaluate publication bias. RESULTS: 14 studies were identified, and 46 fourfold tables were extracted in this meta-analysis. The pooled SEN, SPE, PLR, NLR, DOR, and AUC in diagnosing CT were 0.94 (95% confidence interval (CI): 0.93-0.95), 0.99 (95% CI: 0.99-1.00), 97.17 (95% CI: 56.76-166.32), 0.07 (95% CI: 0.04-0.12), 1857.25 (95% CI: 943.78-3654.86), and 0.9960, respectively. The pooled SEN, SPE, PLR, NLR, DOR, and AUC in diagnosing NG were 0.95 (95% CI: 0.93-0.96), 1.00 (95% CI: 1.00-1.00), 278.15 (95% CI: 152.41-507.63), 0.08 (95% CI: 0.06-0.12), 4290.70 (95% CI: 2161.78-8516.16), and 0.9980, respectively. CONCLUSIONS: Xpert CT/NG had high diagnostic sensitivity and specificity for CT and NG. However, more evidence is required to confirm that Xpert CT/NG might serve as the primary method for detecting CT and NG and even the gold standard for diagnosis in the future.


Asunto(s)
Infecciones por Chlamydia/diagnóstico , Gonorrea/diagnóstico , Área Bajo la Curva , Infecciones por Chlamydia/microbiología , Chlamydia trachomatis/patogenicidad , Gonorrea/microbiología , Humanos , Neisseria gonorrhoeae/patogenicidad , Oportunidad Relativa , Curva ROC , Sensibilidad y Especificidad
13.
Biomed Res Int ; 2020: 3969868, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32964030

RESUMEN

BACKGROUND: Influenza virus mainly causes acute respiratory infections in humans. However, the diagnosis of influenza is not accurate based on clinical evidence, as the symptoms of flu are similar to other respiratory virus. The lateral-flow assay is a rapid method to detect influenza virus. But the effectiveness of the technique in detecting flu viruses is unclear. Hence, a meta-analysis would be performed to evaluate the accuracy of LFA in detecting influenza virus. METHODS: Relevant literature was searched out in PubMed, Embase, Web of Science, and Cochrane Library databases with the keywords "lateral flow assay" and "flu virus". By Meta-DiSc software, pooled sensitivity, pooled specificity, positive likelihood ratio (PLR), negative likelihood ratio (NLR), diagnostic odds ratio (DOR), summary receiver operating characteristic curve (SROC), and area under the curve (AUC) can be calculated. RESULTS: This meta-analysis contains 13 studies and 24 data. The pooled sensitivity and specificity of the influenza virus detected by LFA were 0.84 (95% CI: 0.82-0.86) and 0.97 (95% CI: 0.97-0.98), respectively. The pooled values of PLR, NLR, DOR, and SROC were 32.68 (17.16-62.24), 0.17 (0.13-0.24), 334.07 (144.27-773.53), and 0.9877. No publication bias was found. CONCLUSIONS: LFA exhibited high sensitivity and specificity in diagnosing influenza virus. It is a valuable alternative method which can diagnose influenza virus quickly. However, more evidence is required to confirm whether LFA is comparable to traditional methods for detecting the virus.


Asunto(s)
Infecciones por Orthomyxoviridae/diagnóstico , Orthomyxoviridae/aislamiento & purificación , Animales , Área Bajo la Curva , Humanos , Infecciones por Orthomyxoviridae/virología , Curva ROC , Sensibilidad y Especificidad
15.
BMC Infect Dis ; 20(1): 560, 2020 Jul 31.
Artículo en Inglés | MEDLINE | ID: mdl-32736603

RESUMEN

An amendment to this paper has been published and can be accessed via the original article.

16.
Biomed Res Int ; 2020: 1968487, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32685449

RESUMEN

BACKGROUND: The World Health Organization approved the use of Xpert MTB/RIF for the detection of Mycobacterium tuberculosis DNA, which has significantly improved the diagnosis of tuberculosis. In this study, our main objective was to evaluate the diagnostic efficacy of Xpert MTB/RIF for lymphoid tuberculosis to determine whether Xpert MTB/RIF could be used as a routine detection method. MATERIALS AND METHODS: We searched four databases for the relevant literature published from May 2007 to December 2019. The quality of the literature was evaluated with reference to the evaluation criteria. Data that were extracted from the literature on Xpert MTB/RIF diagnosis of lymphatic tuberculosis were used to plot the summary receiver operating characteristic (SROC) curve, after which the software was used to combine and analyze the accuracy of these data. RESULTS: A total of 27 studies were included. The sensitivity of Xpert MTB/RIF for detecting lymphatic tuberculosis was 0.79 (95% CI (0.77, 0.81)), the specificity was 0.88 (95% CI (0.87, 0.90)), and the positive likelihood ratio (PLR) was 7.21 (95% CI (4.93, 10.55)). In addition, the negative likelihood ratio (NLR) was 0.25 (95% CI (0.19, 0.32)) and the diagnostic odds ratio (DOR) was 40.23 (95% CI (24.53, 65.98)). At the same time, we used the extracted data to make the SROC curve, obtaining the following parameters: area under the curve (AUC) = 0.9144, Q = 0.8470 (SE = 0.0163). CONCLUSION: Xpert MTB/RIF has high accuracy in detecting lymphatic tuberculosis, and it can be used to quickly and easily diagnose lymphatic tuberculosis at an early stage as a general method.


Asunto(s)
Mycobacterium tuberculosis/efectos de los fármacos , Técnicas de Amplificación de Ácido Nucleico/métodos , Rifampin/farmacología , Tuberculosis/diagnóstico , Humanos , Pruebas de Sensibilidad Microbiana , Sesgo de Publicación , Curva ROC
17.
BMC Infect Dis ; 20(1): 525, 2020 Jul 20.
Artículo en Inglés | MEDLINE | ID: mdl-32689953

RESUMEN

BACKGROUND: Neisseria meningitidis is a major cause of bacterial meningitis, and these infections are associated with a high mortality rate. Rapid and reliable diagnosis of bacterial meningitis is critical in clinical practice. However, this disease often occurs in economically depressed areas, so an inexpensive, easy to use, and accurate technology is needed. We performed a pooled-analysis to assess the potential of the recently developed loop-mediated isothermal amplification (LAMP) assay for detection of meningococcus. METHODS: Pubmed, Embase, and Web of Science were searched to identify original studies that used the LAMP assay to detect meningococcus. After pooling of data, the sensitivity and specificity were calculated, a summary receiver operating characteristic (SROC) curve was determined, and the area under the SROC curve was computed to determine diagnostic accuracy. Publication bias was assessed using Deek's funnel plot. RESULTS: We examined 14 studies within 6 publications. The LAMP assay had high sensitivity (94%) and specificity (100%) in the detection of meningococcus in all studies. The area under the SROC curve (0.980) indicated high overall accuracy of the LAMP assay. There was no evidence of publication bias. DISCUSSION: The LAMP assay has accuracy comparable to bacterial culture and PCR for detection of meningococcus, but is less expensive and easier to use. We suggest the adoption of the LAMP assay to detect meningococcus, especially in economically depressed areas.


Asunto(s)
Meningitis Meningocócica/diagnóstico , Técnicas de Diagnóstico Molecular/métodos , Neisseria meningitidis/genética , Técnicas de Amplificación de Ácido Nucleico/métodos , Exactitud de los Datos , Humanos , Meningitis Meningocócica/microbiología , Técnicas de Diagnóstico Molecular/economía , Técnicas de Amplificación de Ácido Nucleico/economía , Reacción en Cadena de la Polimerasa/economía , Reacción en Cadena de la Polimerasa/métodos , Curva ROC , Sensibilidad y Especificidad
18.
Biosci Rep ; 40(6)2020 06 26.
Artículo en Inglés | MEDLINE | ID: mdl-32543657

RESUMEN

BACKGROUND: At present, the infection and prevalence rates of tuberculosis (TB) are still high in worldwide. The Xpert MTB/RIF technology has improved the diagnosis speed of Mycobacterium tuberculosis (MTB) and facilitated the rapid treatment of TB patients. METHODS: We searched experimental data derived from Xpert MTB/RIF for detecting MTB in gastric aspirates in PubMed, Embase, Web Of Science, and the Cochrane Library databases between January 2012 to April 2019. A summary receiver operating characteristic curve (SROC curve) was used to analyze the pooled sensitivity, pooled specificity, PLR, NLR, and DOR for determining the accuracy of the test. RESULTS: Our database search resulted in 10 relevant articles. The pooled sensitivity of Xpert MTB/RIF for detecting TB in GA was 86% (95% CI, 83-89%), and I2 = 93.4%. The pooled specificity was 92% (95% CI, 90-93%) and I2 = 97.8%. In addition, the positive LR was 12.12 (95% CI, 5.60-26.21), negative LR was 0.20 (95% CI, 0.11-0.36), and the diagnostic odds ratio (DOR) was 147.04 (95% CI, 37.20-581.19). Using the SROC curve, the AUC was 0.9730 and Q* was 0.9248 (SE = 0.0261). The publication bias was P=0.517 (P>0.05). CONCLUSIONS: The Xpert MTB/RIF for detecting MTB in gastric aspirates was highly accurate. In addition, we observed that the publication bias in the present study was low. Hence, the Xpert MTB/RIF technology is highly accurate and has the advantage of rapid testing for MTB in clinical samples.


Asunto(s)
Técnicas de Diagnóstico Molecular , Mycobacterium tuberculosis/genética , Estómago/microbiología , Tuberculosis/diagnóstico , Humanos , Mycobacterium tuberculosis/aislamiento & purificación , Valor Predictivo de las Pruebas , Reproducibilidad de los Resultados , Succión , Tuberculosis/microbiología
19.
J Clin Lab Anal ; 34(7): e23281, 2020 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-32157743

RESUMEN

BACKGROUND: Detection of hepatitis B virus (HBV) is vital for the diagnosis of hepatitis B infection. A novel test loop-mediated isothermal amplification (LAMP) has been successfully applied to detect various pathogens. However, the accuracy of LAMP in diagnosing HBV remains unclear. Therefore, in the present study, the accuracy of LAMP for HBV detection was evaluated systematically. METHODS: Embase, Cochrane Library, and PubMed databases were searched for studies using LAMP to detect HBV. Then, two researchers extracted data and assessed the quality of literature using the QUADAS-2 tool independently. I2 statistic and chi-square test were analyzed to investigate the heterogeneity, and Deek's funnel plot assessed the publication bias. The pooled sensitivity (SEN), specificity (SPE), positive LR (PLR), negative LR (NLR), diagnostic odds ratio (DOR), and 95% confidence intervals were displayed in forest plots. We calculated the area under the curve (AUC) to assess the overall efficiency of LAMP for HBV detection. RESULTS: A total of nine studies with 1298 samples were finally included in this evaluation. The pooled sensitivity and specificity of HBV detection were 0.91 (95% CI: 0.89 ~ 0.92) and 0.97 (95% CI: 0.94 ~ 0.99), respectively. The PLR, NLR, and DOR were 16.93 (95% CI: 6.15 ~ 46.55), 0.08 (95% CI: 0.05 ~ 0.14), and 397.57 (95% CI: 145.41 ~ 1087.07). Besides, the AUC was 0.9872, and Deek's plot suggested that there existed publication bias in the studies. CONCLUSION: Compared with PCR, LAMP is a simple, rapid, and effective assay to diagnose HBV. However, additional evidence is essential to confirm that LAMP can replace other methods in diagnosing HBV infection.


Asunto(s)
Hepatitis B/diagnóstico , Técnicas de Diagnóstico Molecular/métodos , Técnicas de Amplificación de Ácido Nucleico/métodos , Hepatitis B/sangre , Humanos , Control de Calidad , Sensibilidad y Especificidad
20.
Biosci Rep ; 39(10)2019 10 30.
Artículo en Inglés | MEDLINE | ID: mdl-31537628

RESUMEN

BACKGROUND: Candida is a fungus that causes various types of candidemia, which is the fourth major infectious disease of the blood system. MALDI-TOF-MS is a simple and rapid detection instrument. The aim of the present study was to verify the accuracy of MALDI-TOF-MS in detecting Candida. METHOD: A pooled analysis of articles on MALDI-TOF-MS for diagnosis of candidemia was performed. The quality of original research was assessed using the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) guidelines. Stata 12.0 software was used to merge the correct identification rates of Candida and Candida subspecies and obtain pooled sensitivity and specificity of the diagnostic methods. Heterogeneity was found in the subgroup analysis of the included articles. Hence, we explored the factors causing the heterogeneity and its impact on the overall situation. Sensitivity analysis was used to examine the effect of Candida level on total response. Egger's test was used to evaluate the publication bias of the included articles. RESULTS: A total of 16 articles in Pubmed, 79 articles in Embase, 1 article in Cochrane Library, 30 articles in Web of Science and 3 from other sources were identified, of which 10 articles were included based on the inclusion and exclusion criteria. The overall identification accuracy was 100%. CONCLUSION: The accuracy of MALDI-TOF-MS for the identification of Candida was 100%. Further research is necessary to determine whether MALDI-TOF-MS can be used as a clinical diagnostic standard for the identification of Candida.


Asunto(s)
Candida/metabolismo , Candidiasis/diagnóstico , Candidiasis/metabolismo , Espectrometría de Masa por Láser de Matriz Asistida de Ionización Desorción/clasificación , Candida/clasificación , Humanos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...