Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 18 de 18
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
J Indian Prosthodont Soc ; 23(2): 184-191, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37102545

RESUMEN

Context: To promote better biological response and osseointegration continuous research is going on to modify the titanium (Ti) implant surface for successful implant treatment modality. Aims: This study aims to evaluate the osteogenic cell growth upon the uncoated Ti discs and boron nitride (BN) coated Ti to assess osseointegration and clinical success of dental implants. Settings and Design: This is an descriptive experimental study which includes coating of uncoated titanium alloy suraface with boron nitride in the form of hexagonal boron nitride sheets. Than comparative evaluation of osteogenic cell growth upon both coated and uncoated titanium surfaces was done using specific cell growth determinants. Materials and Methods: In this descriptive experimental study, both BN-coated and uncoated Ti discs were assessed for osteogenic cell growth using 3-(4, 5-dimethyl thiazolyl-2)-2, 5-diphenyltetrazolium bromide assay, 4',6-diamidino-2-phenylindole, is a fluorescent stain assay, and cell adhesion assay. Statistical Analysis Used: As this study is a descriptive experimental analysis between two variables only so there is no need of statistical analysis or p-value. Results: Overall good cell adhesion, cell differentiation, and cell proliferation occurred in the BN-coated Ti discs as compared to uncoated Ti discs. Conclusions: To promote osseointegration of dental implants, surface coating with BN proved to be an effective approach toward better osseointegration and long-duration success of dental implants as a single unit or implant-supported prosthesis BN which is a biocompatible graphene material with advantages in chemical and thermal stability. BN promoted better osteogenic cell adhesion, differentiation, and proliferation. Hence, it can be used as a new promising Ti implant surface-coating material.


Asunto(s)
Implantes Dentales , Titanio/farmacología , Materiales Biocompatibles Revestidos/farmacología , Materiales Dentales/farmacología , Proliferación Celular
2.
Materials (Basel) ; 15(16)2022 Aug 19.
Artículo en Inglés | MEDLINE | ID: mdl-36013880

RESUMEN

Resin-bonded fixed dental prostheses (RBFDP) are minimally invasive alternatives to traditional full-coverage fixed partial dentures as they rely on resin cements for retention. This study compared and evaluated the tensile bond strength of three different resin-bonded bridge designs, namely, three-unit fixed-fixed, two-unit cantilever single abutment, and three-unit cantilever double-abutted resin-bonded bridge. Furthermore, the study attempted to compare the tensile bond strengths of the Maryland and Rochette types of resin-bonded bridges. Based on the inclusion and exclusion criteria, a total of seventy-five extracted maxillary incisors were collected and later were mounted on the acrylic blocks. Three distinct resin-bonded metal frameworks were designed: three-unit fixed-fixed (n = 30), two-unit cantilever single abutment (n = 30), and a three-unit cantilever double abutment (n = 30). The main groups were further divided into two subgroups based on the retainer design such as Rochette and Maryland. The different prosthesis designs were cemented to the prepared teeth. Later, abutment preparations were made on all specimens keeping the preparation as minimally invasive and esthetic oriented. Impression of the preparations were made using polyvinyl siloxane impression material, followed by pouring cast using die stone. A U-shaped handle of 1.5 mm diameter sprue wax with a 3 mm hole in between was attached to the occlusal surface of each pattern. The wax patterns were sprued and cast in a cobalt-chromium alloy. The castings were cleaned by sandblasting, followed by finishing and polishing. Lastly, based on the study group, specimens for Rochette bridge were perforated to provide mechanical retention between resin cement and metal, whereas the remaining 15 specimens were sandblasted on the palatal side to provide mechanical retention (Maryland bridge). In order to evaluate the tensile bond strength, the specimens were subjected to tensile forces on a universal testing machine with a uniform crosshead speed. The fixed-fixed partial prosthesis proved superior to both cantilever designs, whereas the single abutment cantilever design showed the lowest tensile bond strength. Maryland bridges uniformly showed higher bond strengths across all framework designs. Within the limitations of this study, the three-unit fixed-fixed design and Maryland bridges had greater bond strengths, implying that they may demonstrate lower clinical failure than cantilever designs and Rochette bridges.

3.
J Contemp Dent Pract ; 23(3): 351-354, 2022 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-35781442

RESUMEN

AIM/OBJECTIVE: The aim of this study was to evaluate the displacement of the denture base of conventional acrylic dentures and Click Fit partials in Kennedy's class I and II situations in the mandibular arch. MATERIALS AND METHODS: Four removable partial dentures-two conventional clasp dentures and two attachment dentures (Click Fit)-were designed. The two conventional clasp dentures were retained by C (conventional) clasps, and the two attachment dentures were retained by rigid precision attachments. The displacement of denture bases and the movements of denture bases were investigated, and the influences of denture design were studied. RESULT: The values obtained were statistically analyzed by using independent t-tests. For all statistical purposes, a p-value of ≤0.001 was considered significant. The results showed that mean vertical displacements (mm) of the conventional acrylic removable partial denture base for Kennedy's class I mandibular arch under 50, 75, and 100 N forces were 0.0317, 0.04377, and 0.06392, respectively, and those for Kennedy's class II mandibular arch under 50, 75, and 100 N forces were 0.04922, 0.09849, and 0.1522, respectively. Vertical displacements (mm) of the Click Fit removable partial denture base for Kennedy's class I mandibular arch under 50, 75, and 100 N forces were 0.02185, 0.03436, and 0.005365, respectively, and those for Kennedy's class II mandibular arch under 50N, 75N, and 100N forces were 0.0445, 0.07851, and 0.14457, respectively. The difference between the groups was statistically significant (p ≤0.001). CONCLUSION: The vertical displacement of the denture base retained by conventional C clasps was more than that of the denture base retained by rigid precision attachment. The displacement of the denture base tended to be less when the denture was designed with a rigid connection for the retainer and with cross-arch stabilization as in Kennedy's class I case. CLINICAL IMPLICATIONS: This research evaluated the vertical denture base displacement using different designs and retention types. Hence, it helped predict the prognosis of different removable partial denture base designs in various clinical conditions.


Asunto(s)
Dentadura Parcial Removible , Bases para Dentadura , Movimiento
4.
Materials (Basel) ; 15(12)2022 Jun 12.
Artículo en Inglés | MEDLINE | ID: mdl-35744226

RESUMEN

This in vitro research aimed to evaluate the Tensile Bond Strength of Poly Ether Ether Ketone and Zirconia copings using resin cement with or without Visio.link adhesive. From commercially available Zirconia and PEEK, blocks were machined milled using (CAD)/(CAM) to obtain 20 Zirconia and 20 PEEK copings. These specimens were sandblasted using 110 µm of alumina. The two main groups (20 Zirconia and 20 PEEK copings) were divided further into 4 subgroups, GROUP 1 (n = 10) PEEK substructure with self-adhesive resin cement without pretreatment, and GROUP 2 (n = 10) PEEK substructure with self-adhesive resin cement pre-treated with Visio.link adhesive. GROUP 3 (n = 10) Zirconia copings with self-adhesive resin cement without pretreatment. GROUP 4 (n = 10) Zirconia copings with self-adhesive resin cement pre-treated with Visio.link adhesive. Universal testing machine was used to evaluate the tensile bond strength of these copings. The results were analyzed using SPSS software Version 25.0 (SPSS Inc., Chicago, IL, USA). One-way ANOVA and independent t-test were used to compare the mean scores. Statistically significant increase was observed in Tensile Bond Strength of samples when Visio.link adhesive was used. Tensile Bond Strength of PEEK copings and Zirconia copings with Visio.link adhesive is considerably greater than PEEK copings and Zirconia copings without adhesive. The mean Tensile Bond Strength of Zirconia (with or without adhesive) is less as compared to Tensile Bond Strength of PEEK (with or without adhesive), but the difference is not statistically significant.

5.
J Contemp Dent Pract ; 23(12): 1218-1223, 2022 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-37125519

RESUMEN

AIM: This study was conducted to evaluate the distribution of stress in the bone around the natural tooth, endodontically treated tooth having post and core, and implant as an abutment in different combinations in fixed partial prosthesis using two-dimensional finite element analysis (FEA). MATERIALS AND METHODS: Six models were simulated using ANSYS Modeller19. All six models were divided into 12 zones and 4 lines, and stress values were calculated and compared. The study combinations were - tooth supported fixed partial prosthesis, fixed partial prosthesis having the combination of tooth and post- and core-treated tooth, fixed partial prosthesis with the combination of tooth and implant, fixed partial prosthesis having the combination of implant and post- and core-treated tooth, fixed partial prosthesis with the combination of post- and core-treated tooth on both sides, and fixed partial prosthesis having the combination of implant on both sides. RESULT: On comparing the stress values, the maximum stress value was observed in fixed partial prosthesis having the combination of implant on both sides (306.2434 MPa) followed by Model 4 (223.1255 MPa), Model 3 (154.3952 MPa), Model 5 (136.9041 MPa), Model 2 (116.2034 MPa), and least stress seen in Model 1 (99.6209 MPa), and minimum in tooth supported fixed partial prosthesis (99.6209 MPa). CONCLUSION: This study concluded that stress concentration in bone was maximum when the implant was used as an abutment in fixed partial prosthesis. The least stress was seen in bone around the natural tooth due to the dampening effect of the periodontal ligament. Further, the modulus of elasticity of a post acts as a vital parameter in the distribution of stress in post- and core-treated tooth. CLINICAL SIGNIFICANCE: The stress concentration in the bone around the abutments affects the longevity of the prosthesis, hence, the clinically appropriate combination of the abutments should be considered for a fixed partial prosthesis.


Asunto(s)
Implantes Dentales , Diente , Análisis de Elementos Finitos , Ligamento Periodontal , Prótesis Dental de Soporte Implantado , Estrés Mecánico , Análisis del Estrés Dental , Dentadura Parcial Fija , Pilares Dentales
6.
Indian J Dent Res ; 31(2): 326-330, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32436918

RESUMEN

A patient who is suffering from complete loss of one eye or one phthisical eye due to injury, inflammation, or tumor experiences lot of physical and psychological trauma. Ocular prostheses are used in the management of a wide variety of acquired and congenital anopthalmia. Several techniques have been used in fitting and fabricating artificial eyes. These eyes can be prefabricated or custom made, but a prosthesis that is lifelike in appearance provides a sense of psychological security to the patient, which is better achieved with custom ocular prosthesis. This article discusses series of cases made by utilizing one of the latest techniques of iris duplication (digital imaging) and also aims at enhanced awareness of the cosmetic benefits of custom designed ocular prosthesis when compared with stock eye.


Asunto(s)
Ojo Artificial , Iris , Atrofia , Humanos , Diseño de Prótesis , Proyectos de Investigación
7.
J Contemp Dent Pract ; 20(1): 83-88, 2019 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-31058618

RESUMEN

AIM: To evaluate solubility of soft denture liner material and acrylic denture base resin when stored in 8% and 50% concentration of alcohol and tea(with milk and green tea) at an interval of 4,7,11 and 15 days. MATERIALS AND METHODS: An in vitro study wasdone on 75 standardized samples in disk form (15 mm × 2 mm), each for soft-liner and acrylic denture base resin. Samples were divided into 5 groups (15 per group/per material) and stored in distilled water (A), 8% alcohol (B), 50% alcohol (C), tea with milk (D) and green tea (E). Solubility was determined at each time interval by dividing difference of weight (taken after drying the sample in a desiccator) from day 1 divided by surface area of the specimen. For each day (i.e., 4, 7, 11 and 15),one-way analysis of variance (ANOVA) test was used to determine if the distribution of mean solubility was similar in five groups followed by post-hoc Tukey's test for pair-wise comparisons. RESULTS: Mean solubility of soft-liner was the highest tea with milk (D) followed by green tea (E), then 50% and 8 % alcohol (C and B) and was least in group A at each time of measurement. Mean solubility of an acrylic resin was highest for 8% alcohol (B) and all other groups it was similar. CONCLUSION: This study shows increased solubility for soft-liners when immersed in tea with milk, green tea, and alcohol at 8% and 50% concentration. The solubility of acrylic resin also increases at 8% alcohol concentration. CLINICAL SIGNIFICANCE: Drinks/beverages used in our study are commonly consumed, the results of this study caution for restricting the frequency of intake. However, this needs to be confirmed by in-vivo studies designed to prove the association of denture life with the consumption pattern of these drinks/ beverages.


Asunto(s)
Polimetil Metacrilato , , Ensayo de Materiales , Solubilidad , Propiedades de Superficie
8.
J Int Oral Health ; 7(8): 89-92, 2015 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-26464547

RESUMEN

BACKGROUND: Denture repair involves joining two parts of a fractured denture with a denture repair material. Hence, a substantial repairing system for denture base fracture should be there to elude frequent fracture. MATERIALS AND METHODS: Surface treatment of conventional heat cure denture base resin with different surface treatments (chemical ethyl acetate, and mechanical roughening with bur), with control group formed without surface treatment. Specimens were repaired with auto polymerizing acrylic resin using sprinkle on technique. The testing of the transverse strength of the repaired specimens was evaluated with three-point bending test on universal testing machine. RESULTS: The study revealed that surface chemical treatment with ethyl acetate improved the transverse strength of repaired heat cure denture base when compared with mechanical and control group. A two-way analysis of variance revealed that there was statistically significant difference in mean strengths of the three groups. CONCLUSION: Surface chemical treatment with ethyl acetate improved the transverse strength of the repaired heat cure denture base when compared with mechanical roughening with bur and group without surface treatment.

9.
J Clin Diagn Res ; 9(6): ZC29-34, 2015 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-26266213

RESUMEN

BACKGROUND: In patients with extensive tooth loss, restoration of masticatory function and aesthetics is main concern for a prosthodontist. AIM OF STUDY: This study aimed to evaluate and compare differences in masticatory efficiency of patients treated with complete dentures made with either high impact or flexible resins. SETTING AND DESIGN: The sample size consisted of 10 study subjects. Two sets of dentures first conventional followed by flexible dentures were fabricated for each subject and both the sets of dentures were accessed for masticatory performance and efficiency. MATERIALS AND METHODS: This study compared the masticatory performance and efficiency of dentures by means of standardized mesh sieves. Masticatory efficiency was calculated by recording the total number of chewing cycles and time required to completely swallow a standardized food item. A patient satisfaction questionnaire was given and evaluated. STATISTICAL ANALYSIS USED: The statistical analyses were performed using Z-test of Proportion and Paired t-test. RESULTS: The masticatory performance ratio was found to be more for hard food in conventional dentures. The values of masticatory performance ratios for soft food, time and number of masticatory strokes were indicating better masticatory efficiency of conventional dentures. CONCLUSION: Though masticatory efficiency and performance were found to be better for patient's dentures made with Polymethyl methacrylate (PMMA), a statistically significant number of patients reported that the flexible dentures were more satisfying than the conventional dentures.

10.
J Nat Sci Biol Med ; 6(2): 340-2, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-26283825

RESUMEN

AIM: We evaluated the effect of incorporating Fluconazole, Chlorhexidine Gluconate, and Silver-Zinc Zeolite as bioactive materials (10% of mass) on the flexural strength of commercially available heat-cured polymethyl methacrylate (PMMA; Travelon). MATERIALS AND METHODS: The following four groups were compared; Group 1: Control group with pure PMMA, Group 2: Antibacterial drug group with chlorhexidine gluconate in powder form + PMMA, Group 3: Antifungal drug group with fluconazole in powder form + PMMA, Group 4: Antimicrobial agent group with silver zinc zeolite in powder form + PMMA. After processing, the specimens were subjected for flexural strength testing using three-point bending test in a universal testing machine. RESULTS: A significant (P < 0.0001) decrease in flexural strength following incorporation of Fluconazole, Chlorhexidine Gluconate, and Silver-Zinc Zeolite to heat polymerized acrylic resin was observed when compared with the control group. The decrease in mean flexural strength was minimal in the fluconazole group. CONCLUSION: Although the addition of a bioactive material to PMMA acrylic is desirable, it is not practical as it reduces flexural strength of the acrylic base.

11.
J Int Oral Health ; 7(Suppl 1): 54-6, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-26225106

RESUMEN

BACKGROUND: Acrylic teeth have long been used in the treatment of a complete denture. One of the primary advantages of acrylic teeth is their ability to adhesively bond to the denture base resins. Although the bonding seems satisfactory, however, bond failures at the acrylic teeth and denture base resin interface are still a common clinical problem in prosthodontics. The purpose of this study was to evaluate the bond strength of acrylic teeth to denture base using different polymerizing techniques. MATERIALS AND METHODS: Acrylic resin teeth were bonded to heat cure acrylic resin and were polymerized by conventional water bath and microwave energy. The samples are then retrieved from the flask; trimmed and polished. The samples were then subjected to tensile forces till failure by using the Instron Universal testing machine. The machine used a direct pull on the incisal portion of the lingual surface in a labial direction at a height above the denture base resin bar with a crosshead speed of 0.5 mm/min. RESULTS: In the present study, it was found that conventionally cured specimens exhibited higher bond strength than microwave cured specimens and majority of fractures occur within the body of the tooth. It was found that debonding occurs within the body of the tooth rather than tooth acrylic interface, so there is no need of surface treatment of ridge lap surface. CONCLUSION: Conventionally cured specimens possess statistically higher bond strength than microwave cured specimens.

12.
J Indian Prosthodont Soc ; 15(3): 257-62, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-26929522

RESUMEN

STATEMENT OF PROBLEM: The occurrence porosity in polymethyl methacrylate, the most commonly used denture base material is a problem. The occurrence of oral candidiasis and other infections has also been reported in denture users. PURPOSE: The aim of this study was to evaluate the effect of addition of an antimicrobial agent, silver zeolite on the porosity of denture base resin, which will be an effective tool in the prevention of oral candidiasis among denture wearers. This study also aims to analyze the effect of polymerization technique on porosity in zeolite incorporated dentures to develop a denture base resin which will be easy to process with optimal mechanical and antimicrobial properties. MATERIALS AND METHODS: Eighty rectangular resin specimens (65 mm × 40 mm × 5 mm) were divided into one control group (A) and three experimental groups (B - Microwave cured denture base resin specimens, C - Conventionally cured denture base resin incorporated with antibacterial zeolites, D - Microwave cured denture base resin incorporated with antibacterial zeolites) porosity was calculated by measurement of the specimen volume before and after its immersion in water. Data were analyzed using one-way analysis of variance. RESULTS: The mean values of the percent mean porosity were: A = 0.9555%, B = 0.9590%, C = 0.9630%, D = 0.9695%. No significant differences were found in mean porosity among the groups evaluated. CONCLUSION: Within the limitations of this study, it could be concluded that the addition of zeolites did not result in significant porosity and that the use of microwave processing is a viable option for denture processing.

13.
J Int Oral Health ; 6(1): 66-71, 2014 02.
Artículo en Inglés | MEDLINE | ID: mdl-24653606

RESUMEN

BACKGROUND: Orofacial pain is a common encounter in dentistry (affecting 12% of the population) and is a primary reason for patients seeking emergency care. Dentists often prescribe oral analgesics, which have disadvantages of decreased absorption rates and delayed onset. Intranasal (IN) delivery takes advantage of a large surface area of mucosal tissue for rapid absorption. The purpose of this study was to evaluate the efficacy of IN ketorolac for endodontic pain using a randomized, double-blind, placebocontrolled parallel design study. MATERIALS & METHODS: Twenty patients presenting with moderate to severe endodontic pain were selected to receive IN treatment with placebo (n = 10) or ketorolac (n = 10) 30 minutes before endodontic treatment was started and immediately after the completion of endodontic treatment. Baseline pain levels were recorded before IN treatment. Pain levels were also recorded at 15 and 30 minutes after the initial IN dosing (before endodontic treatment); 30 minutes after completion of endodontic treatment; and 4, 8, and 12 hours after the initial IN spray. RESULTS: IN ketorolac alone or with endodontic treatment showed significantly better pain relief compared with IN placebo spray alone or with endodontic treatment at 30 minutes after the first or second intranasal dose and at 4 hours after the first intranasal dose. CONCLUSIONS: These results suggest that IN ketorolac may provide a novel and efficacious method for pain relief in endodontic pain patients. How to cite the article: Maroli S, Srinath HP, Goinka C, Yadav NS, Bhardwaj A, Varghese RK. Sniffing out pain: An in vivo intranasal study of analgesic efficacy. J Int Oral Health 2014;6(1):66-71.

14.
J Int Oral Health ; 6(6): 26-31, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-25628479

RESUMEN

BACKGROUND: Differences in the dental arch among Bhil Aboriginals were investigated and compared with non-tribal individuals residing in a tribal zone of Central India. Plaster models (120) were made with the help of alginate impression of tribal adults as well as non-tribal adults residing in the same area. The supposition as aboriginals being primitive due to dietary practices maxillary arch size and mandibular arch size is distended in comparison to the non-tribal population as adaptation of soft refined diet has disrupted the growth of the jaws. Hence, an attempt was made to evaluate the arch widths of tribal population and to associate it with non-tribe population in the same area of Central India. MATERIALS AND METHODS: Difference in morphology and dimension of the maxillary and mandibular arches was aimed at Bhil tribes as well as non-tribal residents of tribe rich zone of Central India. The study was steered amid 120 individuals both tribal and non-tribe equally around 60 each through a well-organized out-reach program intermittently. Study models were made of dental arches of all participants. All measurements of the arch dimension were patent on the study casts using an electronic digital sliding caliper. Pair t-test was applied by using SPSS software version-19.0. RESULTS: In the maxillary arch, on appraisal the non-tribal and Bhil tribe's subjects, it showed a statistically significant difference in inter-incisor width (2.95 mm), inter-canine width (2.60 mm), arch depth (3.25 mm). While inter premolar width (0.20 mm) and inter molar width (0.80 mm) anterior arch length (0.60 mm), and posterior arch length (0.10 mm) showed statistically not significant difference between non-tribal population and Bhil tribe subjects. In the mandibular arch, it showed a statistically significant difference in inter-canine width (1.00 mm). Although, inter-incisor width (0.72 mm), inter-molar width (0.80 mm), arch depth (0.90 mm), anterior arch length (0.30 mm), posterior arch length (0.35 mm), and curve of Spee (0.13 mm) showed statistically not significant difference between general population and Bhil tribe subjects. CONCLUSION: When associated non-tribal population to Bhil tribes subjects, for the morphological and dimensional characteristics of dental arches Bhil tribe subjects exhibited: A narrower and shorter maxilla; reduced mandible size; smaller incisor widths for the maxillary and mandibular arches.

15.
J Contemp Dent Pract ; 14(2): 265-8, 2013 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-23811657

RESUMEN

AIM: Aim of the present study was to comparatively evaluate dimensional accuracy of newely introduced elastomeric impression material after repeated pours at different time intervals. MATERIALS AND METHODS: In the present study a total of 20 (10 + 10) impressions of master model were made from vinyl polyether silicone and vinyl polysiloxane impression material. Each impression was repeatedly poured at 1, 24 hours and 14 days. Therefore, a total of 60 casts were obtained. Casts obtained were scanned with three-dimensional (3D) laser scanner and measurements were done. RESULTS: Vinyl polyether silicone produced overall undersized dies, with greatest change being 0.14% only after 14 days. Vinyl polysiloxane produced smaller dies after 1 and 24 hours and larger dies after 14 days, differing from master model by only 0.07% for the smallest die and to 0.02% for the largest die. CONCLUSION: All the deviations measured from the master model with both the impression materials were within a clinically acceptable range. CLINICAL SIGNIFICANCE: In a typical fixed prosthodontic treatment accuracy of prosthesis is critical as it determines the success, failure and the prognosis of treatment including abutments. This is mainly dependent upon fit of prosthesis which in turn is dependent on dimensional accuracy of dies, poured from elastomeric impressions.


Asunto(s)
Materiales de Impresión Dental/química , Elastómeros/química , Imagenología Tridimensional/métodos , Rayos Láser , Técnica de Impresión Dental/instrumentación , Humanos , Ensayo de Materiales , Modelos Dentales , Polivinilos/química , Elastómeros de Silicona/química , Siloxanos/química , Propiedades de Superficie , Factores de Tiempo , Compuestos de Vinilo/química
16.
J Contemp Dent Pract ; 14(1): 80-3, 2013 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-23579899

RESUMEN

AIM: The purpose of this study was to evaluate and compare the flexural strength of commercially available acrylic (trevalone) and modified polymethylmethacrylate (PMMA). MATERIALS AND METHODS: Four groups were tested; Group 1- control group regular MMA, group 2-2% methacrylic acid, 88% MMA, group 3-16% methacrylic acid, 84% MMA group 4- 20% methacrylic acid, 80% MMA 15 resin specimens of each group were polymerized. After processing, the specimens were subjected for flexural strength testing using three point bending test in a Universal Testing Machine. All data was statistically analyzed with one-way ANOVA, differences within the groups were analyzed by Scheffe's analysis. RESULTS: As the ratio of incorporated methacrylic acid to PMMA increased, the flexural strength decreased. Analysis of data revealed a significant decrease in flexural strength of specimens (p < 0.000) after incorporation of 12%, 16%, 20% methacrylic acid to heat polymerized acrylic resin, when compared with the control group. Lowest flexural strength was observed with specimens containing 20% methacrylic acid and highest flexural strength was observed with specimens containing conventional monomer without methacrylic acid. CONCLUSION: It was observed that as the concentration of methacrylic acid in heat polymerized acrylic resin increases, the flexural strength decreases. Lowest flexural strength was observed with specimens containing 20% methacrylic acid and highest flexural strength was observed with specimens containing conventional monomer without methacrylic acid. CLINICAL SIGNIFICANCE: The major advantages of addition of methacrylic acid to polymethylmethacrylate could be for the elderly people with restricted manual dexterity or cognitive disturbances, especially for patients who do not follow an adequate denture cleansing protocol and diabetic patients who are more susceptible for denture stomatitis.


Asunto(s)
Materiales Dentales/química , Metilmetacrilatos/química , Polimetil Metacrilato/química , Análisis del Estrés Dental/instrumentación , Módulo de Elasticidad , Elasticidad , Calor , Humanos , Ensayo de Materiales , Metacrilatos/química , Metilmetacrilato/química , Docilidad , Polimerizacion , Estrés Mecánico , Propiedades de Superficie
17.
J Contemp Dent Pract ; 13(1): 55-60, 2012 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-22430694

RESUMEN

OBJECTIVES: To attain alliance between the oral hygiene practices with prevalence of tooth abrasion among urban and rural adult population of Central India. To plan dental care services in inaccessible areas and to suggest appropriate remedial measures to prevent this avertable and self-inflicted injury of teeth in this cross-sectional study. MATERIALS AND METHODS: A sum of 1045 adult residents both from Urban (529) and rural (516) parts of Bhopal district (Central India) was selected on a random basis. The multistage sampling technique was adopted to ascertain the sample size. In urban area the study population consisted of 240 males, 289 females and 201 males and 315 females in rural area respectively. All residents above 18 years of age from the Bhopal district were included in cross-sectional study. Assessment form comprises of questionnaire and general information on oral hygiene practices, dietary habits and medical history. Abrasion was assessed using diagnostic criteria recommended by Smith and Knight (modified). Chi- square test was used to test associations between categorical variables at 5% level of significance. Regression analysis attempted to define for risk factors causing abrasion. Literature on the prevalence of abrasion is very sparse, so attempt is made to correlate the etiological factors and recommend to prevent tooth wear. RESULTS: Investigation of this cross-sectional study was aggregate of 1045 residences. Result shows high prevalence of abrasion 70.2%. Higher prevalence concomitant with diffident habits related to oral hygiene maintenance was recorded more among rural (76.9%) when compared to urban dwellers (63.7%). Presence of abrasion verifies statistical significance in relation to age, rural urban difference and variations in habit of oral hygiene care. Stated in the present study, avertable and self-inflicted is tooth abrasion, recurrently resulted by the reprehensible brushing method and common use of indigenous material for the maintenance of oral hygiene. CONCLUSION: Shows significant liaisons with the presence of abrasions in relation to Urban and rural dwelling, age, material used and mode of brushing and duration of brushing. Indigenous and course material causes high amount of enamel wear and with the advancement in age abrasion tend to increase. Prevalence of abrasion does not show any gender predilection. Cultural believes, lifestyle and transition reflects in deviating presence of abrasion in populations.


Asunto(s)
Higiene Bucal/estadística & datos numéricos , Salud Rural/estadística & datos numéricos , Abrasión de los Dientes/epidemiología , Salud Urbana/estadística & datos numéricos , Adolescente , Adulto , Factores de Edad , Estudios Transversales , Conducta Alimentaria , Femenino , Conductas Relacionadas con la Salud , Humanos , India/epidemiología , Masculino , Anamnesis , Persona de Mediana Edad , Prevalencia , Cepillado Dental/estadística & datos numéricos , Adulto Joven
18.
J Contemp Dent Pract ; 12(5): 333-8, 2011 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-22269192

RESUMEN

AIM: This study was carried out with the purpose of comparing three impression methods as to which of them placed tissues most favorably. METHODS: The methods used were Hindels method, selective tissue placement method and functional reline method. The measurements obtained were analyzed to determine which of the three impression methods placed the mucosal tissues maximally. To compare and measure tissue placements, autopolymerizing acrylic resin platforms were constructed to the height of the occlusal surfaces of the remaining teeth. 15 orthodontic buccal tubes were placed on each side of the platform. They were arranged in three sets of five and attached to the platform over selected reference regions by means of autopolymerizing resin. The selected reference areas were in anterior, middle and posterior areas of the ridge on either side. RESULTS: No significant difference was seen in tissue placement in the anterior middle and posterior regions in each of the three methods when each method was assessed separately. Selective tissue placement method placed the tissues maximally (7.547 mm) followed by Hindels method (7.2110 mm) and the least placement was by functional reline method (5.856 mm). Tissue placement was significantly higher in Hindels method as compared to functional reline method (p < 0.001). CONCLUSION: Tissue placement was maximum in the posterior region, followed by the middle region and least in the anterior region of the mandibular ridge for all three methods. Selective tissue placement method showed the maximum overall tissue placement followed by the Hindels method and minimum placement was by functional reline method. CLINICAL SIGNIFICANCE: Selective tissue placement method provided maximum overall tissue placement and can be a preferred technique for impression making for bilateral distal extension removable partial denture fabrication.


Asunto(s)
Técnica de Impresión Dental , Diseño de Dentadura , Dentadura Parcial Removible , Resinas Acrílicas/química , Adulto , Alginatos/química , Proceso Alveolar/patología , Sulfato de Calcio/química , Pilares Dentales , Aleaciones Dentales/química , Abrazadera Dental , Materiales de Impresión Dental/química , Técnica de Impresión Dental/instrumentación , Técnica de Impresión Dental/normas , Materiales Dentales/química , Bases para Dentadura , Rebasado de Dentaduras , Diseño de Equipo , Femenino , Humanos , Arcada Parcialmente Edéntula/patología , Arcada Parcialmente Edéntula/rehabilitación , Mandíbula/patología , Modelos Dentales , Mucosa Bucal/patología , Cemento de Óxido de Zinc-Eugenol/química
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...