Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 96
Filtrar
2.
Artículo en Inglés | MEDLINE | ID: mdl-38871537

RESUMEN

BACKGROUND: Permanent pacemaker implantation (PPI) rates following transcatheter aortic valve replacement (TAVR) remain a concern. We assessed the PPI rates over time in patients implanted with an Evolut supra-annular, self-expanding transcatheter valve from the US STS/ACC TVT Registry. METHODS: Patients who underwent TAVR with an Evolut R, Evolut PRO or Evolut PRO+ valve between July 2018 (Q3) and June 2021 (Q2) were included. PPI rates were reported by calendar quarter. In-hospital PPI rates were reported as proportions and 30-day rates as Kaplan-Meier estimates. A Cox regression model was used to determine potential predictors of a new PPI within 30 days of the TAVR procedure. RESULTS: From July 2018 to June 2021, 54,014 TAVR procedures were performed using Evolut valves. Mean age was 79.3 ± 8.8 years and 49.2 % were male. The 30-day PPI rate was 16.6 % in 2018 (Q3) and 10.8 % in 2021 (Q2, 34.9 % decrease, p < 0.001 for trend across all quarters). The in-hospital PPI rate decreased by 40.1 %; from 14.7 % in 2018 (Q3) to 8.8 % in 2021 (Q2) (p < 0.001 for trend across all quarters). Significant predictors of a new PPI within 30 days included a baseline conduction defect, history of atrial fibrillation, home oxygen, and diabetes mellitus. CONCLUSION: From 2018 to 2021, TAVR with an Evolut transcatheter heart valve in over 50,000 patients showed a significant decreasing trend in the rates of in-hospital and 30-day PPI, representing the lowest rate of PPI in any large real-world registry of Evolut. During the same evaluated period, high device success and shorter length of stay was also observed.

3.
JACC Cardiovasc Interv ; 17(12): 1440-1451, 2024 Jun 24.
Artículo en Inglés | MEDLINE | ID: mdl-38639690

RESUMEN

BACKGROUND: Thirty-day outcomes with the investigational Intrepid transapical (TA) transcatheter mitral valve replacement (TMVR) system have previously demonstrated good technical success, but longer-term outcomes in larger cohorts need to be evaluated. OBJECTIVES: The authors sought to evaluate the 2-year safety and performance of the Intrepid TA-TMVR system in patients with symptomatic, ≥moderate-severe mitral regurgitation (MR) and high surgical risk. METHODS: Patient eligibility was determined by local heart teams and approved by a central screening committee. Clinical events were adjudicated by an independent clinical events committee. Echocardiography was evaluated by an independent core laboratory. RESULTS: The cohort included 252 patients that were enrolled at 58 international sites before February 2021 as part of the global Pilot Study (n = 95) or APOLLO trial (primary cohort noneligible + TA roll-ins, n = 157). Mean age was 74.2 years, mean STS-PROM was 6.3%, 60.3% were male, and 80.6% were in NYHA functional class III/IV. Most presented with secondary MR (70.1%), and nearly all had ≥moderate-severe MR (98.4%). All-cause mortality was 13.1% (30-day), 27.3% (1-year), and 36.2% (2-year). The 30-day ≥major bleeding event rate was 22.3%. Heart failure rehospitalization was 9.6% (30-day) and 36.2% (2-year). At 2 years, >50% of patients were alive with improvement in NYHA functional class (82.1%, class I/II), and all patients with available echocardiograms had ≤mild MR. CONCLUSIONS: This analysis represents the largest reported TA-TMVR experience with the longest follow-up in high-risk ≥moderate-severe MR patients. Early mortality and heart failure rehospitalizations were significant, exacerbated by early TA-related bleeding events; however, meaningful improvements in clinical outcomes and marked reductions in MR severity were observed through 2 years.


Asunto(s)
Cateterismo Cardíaco , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Insuficiencia de la Válvula Mitral , Válvula Mitral , Recuperación de la Función , Índice de Severidad de la Enfermedad , Humanos , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/fisiopatología , Insuficiencia de la Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/mortalidad , Femenino , Masculino , Anciano , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/fisiopatología , Válvula Mitral/cirugía , Resultado del Tratamiento , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/instrumentación , Cateterismo Cardíaco/mortalidad , Factores de Tiempo , Anciano de 80 o más Años , Factores de Riesgo , Diseño de Prótesis , Valor Predictivo de las Pruebas , Complicaciones Posoperatorias/etiología , Persona de Mediana Edad , Hemodinámica , Readmisión del Paciente , Ecocardiografía
4.
Am J Cardiol ; 223: 147-155, 2024 Jul 15.
Artículo en Inglés | MEDLINE | ID: mdl-38641189

RESUMEN

There are limited data from randomized controlled trials assessing the impact of transcatheter aortic valve replacement (TAVR) or surgery in women with aortic stenosis and small aortic annuli. We evaluated 2-year clinical and hemodynamic outcomes after aortic valve replacement to understand acute valve performance and early and midterm clinical outcomes. This post hoc analysis pooled women enrolled in the randomized, prospective, multicenter Evolut Low Risk and Surgical Replacement and Transcatheter Aortic Valve Implantation (SURTAVI) intermediate risk trials. Women with severe aortic stenosis at low or intermediate surgical risk who had a computed tomography-measured annular perimeter of ≤72.3 mm were included and underwent self-expanding, supra-annular TAVR or surgery. The primary end point was 2-year all-cause mortality or disabling stroke rate. The study included 620 women (323 TAVR, 297 surgery) with a mean age of 78 years. At 2 years, the all-cause mortality or disabling stroke was 6.5% for TAVR and 8.0% for surgery, p = 0.47. Pacemaker rates were 20.0% for TAVR and 8.3% for surgery, p <0.001. The mean effective orifice area at 2 years was 1.9 ± 0.5 cm2 for TAVR and 1.6 ± 0.5 cm2 for surgery and the mean gradient was 8.0 ± 4.1 versus 12.7 ± 6.0 mm Hg, respectively (both p <0.001). Moderate or severe patient-prothesis mismatch at discharge occurred in 10.9% of patients who underwent TAVR and 33.2% of patients who underwent surgery, p <0.001. In conclusion, in women with small annuli, the clinical outcomes to 2 years were similar between self-expanding, supra-annular TAVR and surgery, with better hemodynamics in the TAVR group and fewer pacemakers in the surgical group.


Asunto(s)
Estenosis de la Válvula Aórtica , Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Femenino , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Estenosis de la Válvula Aórtica/cirugía , Anciano , Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Estudios Prospectivos , Anciano de 80 o más Años , Implantación de Prótesis de Válvulas Cardíacas/métodos , Resultado del Tratamiento , Factores de Riesgo , Índice de Severidad de la Enfermedad , Medición de Riesgo/métodos , Complicaciones Posoperatorias/epidemiología , Tomografía Computarizada por Rayos X , Prótesis Valvulares Cardíacas
5.
JAMA ; 331(13): 1099-1108, 2024 04 02.
Artículo en Inglés | MEDLINE | ID: mdl-38563835

RESUMEN

Importance: Left atrial appendage elimination may improve catheter ablation outcomes for atrial fibrillation. Objective: To assess the safety and effectiveness of percutaneous left atrial appendage ligation adjunctive to catheter pulmonary vein isolation for nonparoxysmal atrial fibrillation. Design, Setting, and Participants: This multicenter, prospective, open-label, randomized clinical trial evaluated the safety and effectiveness of percutaneous left atrial appendage ligation adjunctive to planned pulmonary vein isolation for nonparoxysmal atrial fibrillation present for less than 3 years. Eligible patients were randomized in a 2:1 ratio to undergo left atrial appendage ligation and pulmonary vein isolation or pulmonary vein isolation alone. Use of a 2:1 randomization ratio was intended to provide more device experience and safety data. Patients were enrolled from October 2015 to December 2019 at 53 US sites, with the final follow-up visit on April 21, 2021. Interventions: Left atrial appendage ligation plus pulmonary vein isolation compared with pulmonary vein isolation alone. Main Outcomes and Measures: A bayesian adaptive analysis was used for primary end points. Primary effectiveness was freedom from documented atrial arrythmias of greater than 30 seconds duration 12 months after undergoing pulmonary vein isolation. Rhythm was assessed by Holter monitoring at 6 and 12 months after pulmonary vein isolation, symptomatic event monitoring, or any electrocardiographic tracing obtained through 12 months after pulmonary vein isolation. Primary safety was a composite of predefined serious adverse events compared with a prespecified 10% performance goal 30 days after the procedure. Left atrial appendage closure was evaluated through 12 months after pulmonary vein isolation. Results: Overall, 404 patients were randomized to undergo left atrial appendage ligation plus pulmonary vein isolation and 206 were randomized to undergo pulmonary vein isolation alone. Primary effectiveness was 64.3% with left atrial appendage ligation and pulmonary vein isolation and 59.9% with pulmonary vein isolation only (difference, 4.3% [bayesian 95% credible interval, -4.2% to 13.2%]; posterior superiority probability, 0.835), which did not meet the statistical criterion to establish superiority (0.977). Primary safety was met, with a 30-day serious adverse event rate of 3.4% (bayesian 95% credible interval, 2.0% to 5.0%; posterior probability, 1.0) which was less than the prespecified threshold of 10%. At 12 months after pulmonary vein isolation, complete left atrial appendage closure (0 mm residual communication) was observed in 84% of patients and less than or equal to 5 mm residual communication was observed in 99% of patients. Conclusions and Relevance: Percutaneous left atrial appendage ligation adjunctive to pulmonary vein isolation did not meet prespecified efficacy criteria for freedom from atrial arrhythmias at 12 months compared with pulmonary vein isolation alone for patients with nonparoxysmal atrial fibrillation, but met prespecified safety criteria and demonstrated high rates of closure at 12 months. Trial Registration: ClinicalTrials.gov Identifier: NCT02513797.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Compuestos Organotiofosforados , Venas Pulmonares , Humanos , Apéndice Atrial/cirugía , Fibrilación Atrial/cirugía , Teorema de Bayes , Estudios Prospectivos , Venas Pulmonares/cirugía , Ablación por Catéter , Cateterismo
6.
JACC Cardiovasc Interv ; 17(8): 979-988, 2024 Apr 22.
Artículo en Inglés | MEDLINE | ID: mdl-38658126

RESUMEN

BACKGROUND: Symptomatic patients with severe aortic stenosis (AS) at high risk for surgical aortic valve replacement (SAVR) sustain comparable improvements in health status over 5 years after transcatheter aortic valve replacement (TAVR) or SAVR. Whether a similar long-term benefit is observed among intermediate-risk AS patients is unknown. OBJECTIVES: The purpose of this study was to assess health status outcomes through 5 years in intermediate risk patients treated with a self-expanding TAVR prosthesis or SAVR using data from the SURTAVI (Surgical Replacement and Transcatheter Aortic Valve Implantation) trial. METHODS: Intermediate-risk patients randomized to transfemoral TAVR or SAVR in the SURTAVI trial had disease-specific health status assessed at baseline, 30 days, and annually to 5 years using the Kansas City Cardiomyopathy Questionnaire (KCCQ). Health status was compared between groups using fixed effects repeated measures modelling. RESULTS: Of the 1,584 patients (TAVR, n = 805; SAVR, n = 779) included in the analysis, health status improved more rapidly after TAVR compared with SAVR. However, by 1 year, both groups experienced large health status benefits (mean change in KCCQ-Overall Summary Score (KCCQ-OS) from baseline: TAVR: 20.5 ± 22.4; SAVR: 20.5 ± 22.2). This benefit was sustained, albeit modestly attenuated, at 5 years (mean change in KCCQ-OS from baseline: TAVR: 15.4 ± 25.1; SAVR: 14.3 ± 24.2). There were no significant differences in health status between the cohorts at 1 year or beyond. Similar findings were observed in the KCCQ subscales, although a substantial attenuation of benefit was noted in the physical limitation subscale over time in both groups. CONCLUSIONS: In intermediate-risk AS patients, both transfemoral TAVR and SAVR resulted in comparable and durable health status benefits to 5 years. Further research is necessary to elucidate the mechanisms for the small decline in health status noted at 5 years compared with 1 year in both groups. (Safety and Efficacy Study of the Medtronic CoreValve® System in the Treatment of Severe, Symptomatic Aortic Stenosis in Intermediate Risk Subjects Who Need Aortic Valve Replacement [SURTAVI]; NCT01586910).


Asunto(s)
Estenosis de la Válvula Aórtica , Válvula Aórtica , Arteria Femoral , Estado de Salud , Prótesis Valvulares Cardíacas , Calidad de Vida , Recuperación de la Función , Índice de Severidad de la Enfermedad , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/fisiopatología , Femenino , Masculino , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Resultado del Tratamiento , Anciano , Anciano de 80 o más Años , Factores de Riesgo , Válvula Aórtica/cirugía , Válvula Aórtica/fisiopatología , Válvula Aórtica/diagnóstico por imagen , Medición de Riesgo , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Cateterismo Periférico/efectos adversos , Punciones , Diseño de Prótesis
7.
JACC Cardiovasc Interv ; 17(8): 1007-1016, 2024 Apr 22.
Artículo en Inglés | MEDLINE | ID: mdl-38573257

RESUMEN

BACKGROUND: Data on valve reintervention after transcatheter aortic valve replacement (TAVR) or surgical aortic valve replacement (SAVR) are limited. OBJECTIVES: The authors compared the 5-year incidence of valve reintervention after self-expanding CoreValve/Evolut TAVR vs SAVR. METHODS: Pooled data from CoreValve and Evolut R/PRO (Medtronic) randomized trials and single-arm studies encompassed 5,925 TAVR (4,478 CoreValve and 1,447 Evolut R/PRO) and 1,832 SAVR patients. Reinterventions were categorized by indication, timing, and treatment. The cumulative incidence of reintervention was compared between TAVR vs SAVR, Evolut vs CoreValve, and Evolut vs SAVR. RESULTS: There were 99 reinterventions (80 TAVR and 19 SAVR). The cumulative incidence of reintervention through 5 years was higher with TAVR vs SAVR (2.2% vs 1.5%; P = 0.017), with differences observed early (≤1 year; adjusted subdistribution HR: 3.50; 95% CI: 1.53-8.02) but not from >1 to 5 years (adjusted subdistribution HR: 1.05; 95% CI: 0.48-2.28). The most common reason for reintervention was paravalvular regurgitation after TAVR and endocarditis after SAVR. Evolut had a significantly lower incidence of reintervention than CoreValve (0.9% vs 1.6%; P = 0.006) at 5 years with differences observed early (adjusted subdistribution HR: 0.30; 95% CI: 0.12-0.73) but not from >1 to 5 years (adjusted subdistribution HR: 0.61; 95% CI: 0.21-1.74). The 5-year incidence of reintervention was similar for Evolut vs SAVR (0.9% vs 1.5%; P = 0.41). CONCLUSIONS: A low incidence of reintervention was observed for CoreValve/Evolut R/PRO and SAVR through 5 years. Reintervention occurred most often at ≤1 year for TAVR and >1 year for SAVR. Most early reinterventions were with the first-generation CoreValve and managed percutaneously. Reinterventions were more common following CoreValve TAVR compared with Evolut TAVR or SAVR.


Asunto(s)
Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Complicaciones Posoperatorias , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/fisiopatología , Prótesis Valvulares Cardíacas , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Complicaciones Posoperatorias/cirugía , Diseño de Prótesis , Ensayos Clínicos Controlados Aleatorios como Asunto , Medición de Riesgo , Factores de Riesgo , Índice de Severidad de la Enfermedad , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Resultado del Tratamiento , Incidencia , Retratamiento
8.
EuroIntervention ; 20(6): e376-e388, 2024 03 18.
Artículo en Inglés | MEDLINE | ID: mdl-38506739

RESUMEN

BACKGROUND: There are limited data regarding treatment for failed balloon-expandable transcatheter heart valves (THVs) in redo-transcatheter aortic valve implantation (TAVI). AIMS: We aimed to assess THV performance, neoskirt height and expansion when performing redo-TAVI with the ACURATE platform inside a SAPIEN 3 (S3) compared to redo-TAVI with an S3 in an S3. METHODS: Redo-TAVI was performed on the bench using each available size of the S3, the ACURATE neo2 (ACn2) and the next-generation ACURATE Prime XL (AC XL) implanted at 2 different depths within 20 mm/23 mm/26 mm/29 mm S3s serving as the "failed" index THV. Hydrodynamic testing was performed to assess THV function. Multimodality assessment was performed using photography, X-ray, microcomputed tomography (micro-CT), and high-speed videos. RESULTS: The ACURATE in S3 combinations had favourable hydrodynamic performance compared to the S3 in S3 for all size combinations. In the 20 mm S3, redo-TAVI with the ACn2 had lower gradients compared to the S3 (mean gradient 16.3 mmHg for the ACn2 vs 24.7 mmHg for the 20 mm S3 in 20 mm S3). Pinwheeling was less marked for the ACURATE THVs than for the S3s. On micro-CT, the S3s used for redo-TAVI were underexpanded across all sizes. This was also observed for the ACURATE platform, but to a lesser extent. CONCLUSIONS: Redo-TAVI with an ACn2/AC XL within an S3 has favourable hydrodynamic performance and less pinwheeling compared to an S3 in S3. This comes at the price of a taller neoskirt.


Asunto(s)
Insuficiencia Cardíaca , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Microtomografía por Rayos X , Catéteres , Válvulas Cardíacas
11.
Catheter Cardiovasc Interv ; 102(4): 721-730, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-37605512

RESUMEN

BACKGROUND: Bicuspid aortic valve (BAV) is present in approximately 0.5%-2% of the general population, causing significant aortic stenosis (AS) in 12%-37% of affected individuals. Transcatheter aortic valve replacement (TAVR) is being considered the treatment of choice in patients with symptomatic AS across all risk spectra. AIM: Aim Our study aims to compare TAVR outcomes in patients with BAV versus tricuspid aortic valves (TAV). METHODS: A comprehensive literature search was performed in PubMed, Web of Science, and Cochrane trials. Studies were included if they included BAV and TAV patients undergoing TAVR with quantitative data available for at least one of our predefined outcomes. Meta-analysis was performed by the random-effects model using Stata software. RESULTS: Fifty studies of 203,288 patients were included. BAV patients had increased 30-day all-cause mortality (odds ratio [OR] = 1.23 [1.00-1.50], p = 0.05), in-hospital stroke (OR = 1.39 [1.01-1.93], p = 0.05), in-hospital and 30-day PPI (OR = 1.13 [1.00-1.27], p = 0.04; OR = 1.16 [1.04-1.13], p = 0.01) and in-hospital, 30-day and 1-year aortic regurgitation (AR) (OR = 1.48 [1.19-1.83], p < 0.01; OR = 1.79 [1.26-2.52], p < 0.01; OR = 1.64 [1.03-2.60], p = 0.04). Subgroup analysis on new-generation valves showed a reduced 1-year all-cause mortality (OR = 0.86 [CI = 0.75-0.98], p = 0.03), despite higher in-hospital and 30-day PPI (OR = 0.1.21 [1.04-1.41], p = 0.01; OR = 1.17 [1.05-1.31], p = 0.01) and in-hospital AR (OR = 1.62 [1.14-2.31], p = 0.01) in the BAV group. The quality of included studies was moderate-to-high, and only three analyses presented high heterogeneity. CONCLUSION: TAVR is associated with comparable outcomes in patients with BAV and TAV. Careful selection of BAV cases by preprocedural assessment of valve anatomy and burden of calcification, pre- and post-procedural dilation, and implementing newer generations of valves may improve the safety and efficacy of TAVR in BAV patients.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Estenosis de la Válvula Aórtica , Enfermedad de la Válvula Aórtica Bicúspide , Enfermedades de las Válvulas Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Enfermedad de la Válvula Aórtica Bicúspide/cirugía , Enfermedades de las Válvulas Cardíacas/diagnóstico por imagen , Enfermedades de las Válvulas Cardíacas/cirugía , Enfermedades de las Válvulas Cardíacas/etiología , Resultado del Tratamiento , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/etiología , Insuficiencia de la Válvula Aórtica/etiología
13.
J Am Coll Cardiol ; 81(17): 1663-1674, 2023 05 02.
Artículo en Inglés | MEDLINE | ID: mdl-36882136

RESUMEN

BACKGROUND: Randomized data comparing outcomes of transcatheter aortic valve replacement (TAVR) with surgery in low-surgical risk patients at time points beyond 2 years is limited. This presents an unknown for physicians striving to educate patients as part of a shared decision-making process. OBJECTIVES: The authors evaluated 3-year clinical and echocardiographic outcomes from the Evolut Low Risk trial. METHODS: Low-risk patients were randomized to TAVR with a self-expanding, supra-annular valve or surgery. The primary endpoint of all-cause mortality or disabling stroke and several secondary endpoints were assessed at 3 years. RESULTS: There were 1,414 attempted implantations (730 TAVR; 684 surgery). Patients had a mean age of 74 years and 35% were women. At 3 years, the primary endpoint occurred in 7.4% of TAVR patients and 10.4% of surgery patients (HR: 0.70; 95% CI: 0.49-1.00; P = 0.051). The difference between treatment arms for all-cause mortality or disabling stroke remained broadly consistent over time: -1.8% at year 1; -2.0% at year 2; and -2.9% at year 3. The incidence of mild paravalvular regurgitation (20.3% TAVR vs 2.5% surgery) and pacemaker placement (23.2% TAVR vs 9.1% surgery; P < 0.001) were lower in the surgery group. Rates of moderate or greater paravalvular regurgitation for both groups were <1% and not significantly different. Patients who underwent TAVR had significantly improved valve hemodynamics (mean gradient 9.1 mm Hg TAVR vs 12.1 mm Hg surgery; P < 0.001) at 3 years. CONCLUSIONS: Within the Evolut Low Risk study, TAVR at 3 years showed durable benefits compared with surgery with respect to all-cause mortality or disabling stroke. (Medtronic Evolut Transcatheter Aortic Valve Replacement in Low Risk Patients; NCT02701283).


Asunto(s)
Insuficiencia de la Válvula Aórtica , Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Accidente Cerebrovascular , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Femenino , Anciano , Masculino , Válvula Aórtica/cirugía , Insuficiencia de la Válvula Aórtica/cirugía , Factores de Riesgo , Resultado del Tratamiento , Estudios Prospectivos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Prótesis Valvulares Cardíacas/efectos adversos , Accidente Cerebrovascular/epidemiología , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/cirugía
14.
Am J Cardiol ; 193: 1-18, 2023 04 15.
Artículo en Inglés | MEDLINE | ID: mdl-36857839

RESUMEN

Since the first transcatheter delivery of an aortic valve prosthesis was performed by Cribier et al in 2002, the picture of aortic stenosis (AS) therapeutics has changed dramatically. Initiated from an indication of inoperable to high surgical risk, extending to intermediate and low risk, transcatheter aortic valve replacement (TAVR) is now an approved treatment for patients with severe, symptomatic AS across all the risk categories. The current evidence supports TAVR as a frontline therapy for treating severe AS. The crucial question remains concerning the subset of patients who still are not ideal candidates for TAVR because of certain inherent anatomic, nonmodifiable, and procedure-specific factors. Therefore, in this study, we focus on these scenarios and reasons for referring selected patients for surgical aortic valve replacement in 2023.


Asunto(s)
Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Factores de Riesgo , Resultado del Tratamiento , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/etiología , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Prótesis Valvulares Cardíacas/efectos adversos
15.
JACC Cardiovasc Interv ; 16(5): 558-570, 2023 03 13.
Artículo en Inglés | MEDLINE | ID: mdl-36922042

RESUMEN

BACKGROUND: Procedural success and clinical outcomes after transcatheter aortic valve replacement (TAVR) have improved, but residual aortic regurgitation (AR) and new permanent pacemaker implantation (PPI) rates remain variable because of a lack of uniform periprocedural management and implantation. OBJECTIVES: The Optimize PRO study evaluates valve performance and procedural outcomes using an "optimized" TAVR care pathway and the cusp overlap technique (COT) in patients receiving the Evolut PRO/PRO+ (Medtronic) self-expanding valves. METHODS: Optimize PRO, a nonrandomized, prospective, postmarket study conducted in the United States, Canada, Europe, Middle East, and Australia, is enrolling patients with severe symptomatic aortic stenosis and no pre-existing pacemaker. Sites follow a standardized TAVR care pathway, including early discharge and a conduction disturbance management algorithm, and transfemoral deployment using the COT. RESULTS: A total of 400 attempted implants from the United States and Canada comprised the main cohort of this second interim analysis. The mean age was 78.7 ± 6.6 years, and the mean Society of Thoracic Surgeons predictive risk of mortality was 3.0 ± 2.4. The median length of stay was 1 day. There were no instances of moderate or severe AR at discharge. At 30 days, all-cause mortality or stroke was 3.8%, all-cause mortality was 0.8%, disabling stroke was 0.7%, hospital readmission was 10.1%, and cardiovascular rehospitalization was 6.1%. The new PPI rate was 9.8%, 5.8% with 4-step COT compliance. In the multivariable model, right bundle branch block and the depth of the implant increased the risk of PPI, whereas using the 4-step COT lowered 30-day PPI. CONCLUSIONS: The use of the TAVR care pathway and COT resulted in favorable clinical outcomes with no moderate or severe AR and low PPI rates at 30 days while facilitating early discharge and reproducible outcomes across various sites and operators. (Optimize PRO; NCT04091048).


Asunto(s)
Insuficiencia de la Válvula Aórtica , Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Accidente Cerebrovascular , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Estados Unidos , Anciano , Anciano de 80 o más Años , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/complicaciones , Vías Clínicas , Estudios Prospectivos , Factores de Riesgo , Resultado del Tratamiento , Insuficiencia de la Válvula Aórtica/etiología , Prótesis Valvulares Cardíacas/efectos adversos
16.
JAMA Cardiol ; 8(2): 111-119, 2023 02 01.
Artículo en Inglés | MEDLINE | ID: mdl-36515976

RESUMEN

Importance: The frequency and clinical importance of structural valve deterioration (SVD) in patients undergoing self-expanding transcatheter aortic valve implantation (TAVI) or surgery is poorly understood. Objective: To evaluate the 5-year incidence, clinical outcomes, and predictors of hemodynamic SVD in patients undergoing self-expanding TAVI or surgery. Design, Setting, and Participants: This post hoc analysis pooled data from the CoreValve US High Risk Pivotal (n = 615) and SURTAVI (n = 1484) randomized clinical trials (RCTs); it was supplemented by the CoreValve Extreme Risk Pivotal trial (n = 485) and CoreValve Continued Access Study (n = 2178). Patients with severe aortic valve stenosis deemed to be at intermediate or increased risk of 30-day surgical mortality were included. Data were collected from December 2010 to June 2016, and data were analyzed from December 2021 to October 2022. Interventions: Patients were randomized to self-expanding TAVI or surgery in the RCTs or underwent self-expanding TAVI for clinical indications in the nonrandomized studies. Main Outcomes and Measures: The primary end point was the incidence of SVD through 5 years (from the RCTs). Factors associated with SVD and its association with clinical outcomes were evaluated for the pooled RCT and non-RCT population. SVD was defined as (1) an increase in mean gradient of 10 mm Hg or greater from discharge or at 30 days to last echocardiography with a final mean gradient of 20 mm Hg or greater or (2) new-onset moderate or severe intraprosthetic aortic regurgitation or an increase of 1 grade or more. Results: Of 4762 included patients, 2605 (54.7%) were male, and the mean (SD) age was 82.1 (7.4) years. A total of 2099 RCT patients, including 1128 who received TAVI and 971 who received surgery, and 2663 non-RCT patients who received TAVI were included. The cumulative incidence of SVD treating death as a competing risk was lower in patients undergoing TAVI than surgery (TAVI, 2.20%; surgery, 4.38%; hazard ratio [HR], 0.46; 95% CI, 0.27-0.78; P = .004). This lower risk was most pronounced in patients with smaller annuli (23 mm diameter or smaller; TAVI, 1.32%; surgery, 5.84%; HR, 0.21; 95% CI, 0.06-0.73; P = .02). SVD was associated with increased 5-year all-cause mortality (HR, 2.03; 95% CI, 1.46-2.82; P < .001), cardiovascular mortality (HR, 1.86; 95% CI, 1.20-2.90; P = .006), and valve disease or worsening heart failure hospitalizations (HR, 2.17; 95% CI, 1.23-3.84; P = .008). Predictors of SVD were developed from multivariate analysis. Conclusions and Relevance: This study found a lower rate of SVD in patients undergoing self-expanding TAVI vs surgery at 5 years. Doppler echocardiography was a valuable tool to detect SVD, which was associated with worse clinical outcomes. Trial Registration: ClinicalTrials.gov Identifiers: NCT01240902, NCT01586910, and NCT01531374.


Asunto(s)
Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Masculino , Humanos , Anciano de 80 o más Años , Femenino , Válvula Aórtica/cirugía , Resultado del Tratamiento , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos
17.
Cardiovasc Revasc Med ; 47: 48-54, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-36266154

RESUMEN

We evaluated predictors of permanent pacemaker implantation (PPI) following self-expanding transcatheter aortic valve replacement (TAVR), examined site-to-site variability of PPI rates, and explored the relationship of implantation methods on the need for PPI. Despite the benefits of TAVR compared to surgical aortic valve replacement, increased PPI remains a limitation. A total of 699 patients without baseline PPI were included in the study. Clinical, echocardiographic, and procedural characteristics were compared in patient with and without new PPI. Clinical outcomes were assessed at 30 days and 1 year. Funnel plots were constructed to display site-to- site variability and identify outliers in PPI. Clinical outcomes were similar in patients with and without PPI. Predictors of a new PPI within 7 days included a baseline right bundle branch block (p < 0.001) and not using general anesthesia (p = 0.003). There was substantial site to site variability in the rate of PPI. Patients at sites with a lower PPI rate had shallower implantation depth at the non-coronary (p < 0.001) and the left coronary sinus (p < 0.001), and fewer patients with an implantation depth > 5 mm below the annulus (p = 0.004). In low-risk patients undergoing TAVR with Evolut valves, baseline conduction disorders and implant depth were important predictors of PPI. Implantation method may have contributed to this variability in PPI rates across clinical sites.


Asunto(s)
Estenosis de la Válvula Aórtica , Marcapaso Artificial , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Estenosis de la Válvula Aórtica/cirugía , Prótesis Valvulares Cardíacas , Marcapaso Artificial/estadística & datos numéricos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
18.
JAMA Cardiol ; 7(10): 1000-1008, 2022 10 01.
Artículo en Inglés | MEDLINE | ID: mdl-36001335

RESUMEN

Importance: In patients with severe aortic valve stenosis at intermediate surgical risk, transcatheter aortic valve replacement (TAVR) with a self-expanding supra-annular valve was noninferior to surgery for all-cause mortality or disabling stroke at 2 years. Comparisons of longer-term clinical and hemodynamic outcomes in these patients are limited. Objective: To report prespecified secondary 5-year outcomes from the Symptomatic Aortic Stenosis in Intermediate Risk Subjects Who Need Aortic Valve Replacement (SURTAVI) randomized clinical trial. Design, Setting, and Participants: SURTAVI is a prospective randomized, unblinded clinical trial. Randomization was stratified by investigational site and need for revascularization determined by the local heart teams. Patients with severe aortic valve stenosis deemed to be at intermediate risk of 30-day surgical mortality were enrolled at 87 centers from June 19, 2012, to June 30, 2016, in Europe and North America. Analysis took place between August and October 2021. Intervention: Patients were randomized to TAVR with a self-expanding, supra-annular transcatheter or a surgical bioprosthesis. Main Outcomes and Measures: The prespecified secondary end points of death or disabling stroke and other adverse events and hemodynamic findings at 5 years. An independent clinical event committee adjudicated all serious adverse events and an independent echocardiographic core laboratory evaluated all echocardiograms at 5 years. Results: A total of 1660 individuals underwent an attempted TAVR (n = 864) or surgical (n = 796) procedure. The mean (SD) age was 79.8 (6.2) years, 724 (43.6%) were female, and the mean (SD) Society of Thoracic Surgery Predicted Risk of Mortality score was 4.5% (1.6%). At 5 years, the rates of death or disabling stroke were similar (TAVR, 31.3% vs surgery, 30.8%; hazard ratio, 1.02 [95% CI, 0.85-1.22]; P = .85). Transprosthetic gradients remained lower (mean [SD], 8.6 [5.5] mm Hg vs 11.2 [6.0] mm Hg; P < .001) and aortic valve areas were higher (mean [SD], 2.2 [0.7] cm2 vs 1.8 [0.6] cm2; P < .001) with TAVR vs surgery. More patients had moderate/severe paravalvular leak with TAVR than surgery (11 [3.0%] vs 2 [0.7%]; risk difference, 2.37% [95% CI, 0.17%- 4.85%]; P = .05). New pacemaker implantation rates were higher for TAVR than surgery at 5 years (289 [39.1%] vs 94 [15.1%]; hazard ratio, 3.30 [95% CI, 2.61-4.17]; log-rank P < .001), as were valve reintervention rates (27 [3.5%] vs 11 [1.9%]; hazard ratio, 2.21 [95% CI, 1.10-4.45]; log-rank P = .02), although between 2 and 5 years only 6 patients who underwent TAVR and 7 who underwent surgery required a reintervention. Conclusions and Relevance: Among intermediate-risk patients with symptomatic severe aortic stenosis, major clinical outcomes at 5 years were similar for TAVR and surgery. TAVR was associated with superior hemodynamic valve performance but also with more paravalvular leak and valve reinterventions.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Accidente Cerebrovascular , Anciano , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/complicaciones , Femenino , Prótesis Valvulares Cardíacas/efectos adversos , Humanos , Masculino , Estudios Prospectivos , Accidente Cerebrovascular/epidemiología , Accidente Cerebrovascular/etiología
19.
JACC Cardiovasc Interv ; 15(7): 728-738, 2022 04 11.
Artículo en Inglés | MEDLINE | ID: mdl-35393106

RESUMEN

OBJECTIVES: This study sought to evaluate patient-centered metrics in intermediate-surgical-risk aortic stenosis patients enrolled in the SURTAVI (Surgical Replacement and Transcatheter Aortic Valve Implantation) trial treated with self-expanding transcatheter aortic valve replacement (TAVR) or surgery. BACKGROUND: Studies have shown TAVR to be an alternative to surgery in patients with severe symptomatic aortic stenosis but have focused on "hard endpoints," including all-cause mortality and stroke, rather than on comparative patient-centered metrics, such as functional status and symptom burden. METHODS: The study analyzed functional status (6-minute walk test [6MWT]) and symptom burden (Kansas City Cardiomyopathy Questionnaire) in 1,492 patients from the SURTAVI trial at baseline, 30 days, 1 year, and 2 years. Patients were categorized by baseline functional status into tertiles of slow, medium, and fast walkers. RESULTS: Patients with lowest capacity baseline functional status were commonly women, had higher Society of Thoracic Surgeons scores, and had more New York Heart Association functional class III or IV symptoms; reduced baseline functional status was associated with higher aortic valve- and heart failure-related hospitalization at 2 years. There was greater improvement in 6MWT distance in TAVR compared with surgery patients at 30 days (P < 0.001) and 1 year (P = 0.012), but at 2 years, both groups had similar improvement (P = 0.091). The percentage of patients with large improvement in 6MWT was greatest in patients categorized as slow walkers and lowest in fast walkers. Symptom burden improved after TAVR at 30 days and after both procedures at 1 and 2 years. CONCLUSIONS: In this substudy of patients from the SURTAVI trial, patients receiving TAVR demonstrated a more rapid improvement in functional status and symptom burden compared with patients undergoing surgery; however, both groups had similar improvements in long-term follow-up. (Safety and Efficacy Study of the Medtronic CoreValve® System in the Treatment of Severe, Symptomatic Aortic Stenosis in Intermediate Risk Subjects Who Need Aortic Valve Replacement [SURTAVI]; NCT01586910).


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Femenino , Estado Funcional , Humanos , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
20.
Cardiovasc Revasc Med ; 42: 1-5, 2022 09.
Artículo en Inglés | MEDLINE | ID: mdl-35398007

RESUMEN

BACKGROUND: Death in high- and intermediate-risk patients after self-expanding transcatheter (TAVR) and surgical aortic valve replacement (surgery) differed in mechanisms and timing. In both risk groups, 1-year all-cause mortality was lower in TAVR than in surgery patients. The differences in mechanism and timing of death in low-risk patients has not been studied. This report explores the mechanisms of death during 3 time periods; 0 to 30 days (early), 31 to 120 days (recovery), and 121 to 365 days (late). METHODS: We retrospectively examined the mechanisms and timing of death following TAVR or surgery in the randomized Evolut Low Risk Trial. Patients were enrolled between March 2016 and November 2018 from 86 designated TAVR centers. Mechanisms of death were categorized as due to technical reasons, failure to repair, complications linked to death, failure to recover or other. RESULTS: All-cause mortality at 1 year was 2.2% for TAVR and 2.8% for surgery, p = 0.44. Early deaths included 3 TAVR patients, all due to technical reasons, and 8 surgery patients (1 technical, 5 complications and 2 failed to recover). Recovery period deaths included 6 TAVR patients (4 complications, 1 failed to recover and 1 other), and 1 surgery patient from complications of valve endocarditis. Late period deaths included 6 TAVR patients and 9 surgery patients, primarily due to complications. CONCLUSIONS: In this low-risk study cohort, no patient died from failure to repair the valve; reduction in procedural complications in the TAVR and surgery groups remain opportunities for further improvement in outcomes. Clinical Trial Registrations (clinicaltrials.gov): NCT02701283 (Evolut Low Risk).


Asunto(s)
Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/complicaciones , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Humanos , Estudios Retrospectivos , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...