Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Brain Sci ; 12(1)2022 Jan 08.
Artículo en Inglés | MEDLINE | ID: mdl-35053829

RESUMEN

BACKGROUND: Current approaches to detect the positions and orientations of directional deep brain stimulation (DBS) electrodes rely on radiative imaging data. In this study, we aim to present an improved version of a radiation-free method for magnetic detection of the position and the orientation (MaDoPO) of directional electrodes based on a series of magnetoencephalography (MEG) measurements and a possible future solution for optimized results using emerging on-scalp MEG systems. METHODS: A directional DBS system was positioned into a realistic head-torso phantom and placed in the MEG scanner. A total of 24 measurements of 180 s each were performed with different predefined electrode configurations. Finite element modeling and model fitting were used to determine the position and orientation of the electrode in the phantom. Related measurements were fitted simultaneously, constraining solutions to the a priori known geometry of the electrode. Results were compared with the results of the high-quality CT imaging of the phantom. RESULTS: The accuracy in electrode localization and orientation detection depended on the number of combined measurements. The localization error was minimized to 2.02 mm by considering six measurements with different non-directional bipolar electrode configurations. Another six measurements with directional bipolar stimulations minimized the orientation error to 4°. These values are mainly limited due to the spatial resolution of the MEG. Moreover, accuracies were investigated as a function of measurement time, number of sensors, and measurement direction of the sensors in order to define an optimized MEG device for this application. CONCLUSION: Although MEG introduces inaccuracies in the detection of the position and orientation of the electrode, these can be accepted when evaluating the benefits of a radiation-free method. Inaccuracies can be further reduced by the use of on-scalp MEG sensor arrays, which may find their way into clinics in the foreseeable future.

2.
J Neural Eng ; 18(5)2021 10 14.
Artículo en Inglés | MEDLINE | ID: mdl-34598173

RESUMEN

Objective.The aim of the present study was to evaluate the effect of different electrode configurations on the accuracy of determining the rotational orientation of the directional deep brain stimulation (DBS) electrode with our previously published magnetoencephalography (MEG)-based method.Approach.A directional DBS electrode, along with its implantable pulse generator, was integrated into a head phantom and placed within the MEG sensor array. Predefined bipolar electrode configurations, based on activation of different directional and omnidirectional contacts of the electrode, were set to generate a defined magnetic field during stimulation. This magnetic field was then measured with MEG. Finite element modeling and model fitting approach were used to calculate electrode orientation.Main results.The accuracy of electrode orientation detection depended on the electrode configuration: the vertical configuration (activation of two directional contacts arranged one above the other) achieved an average accuracy of only about 41 ∘. The diagonal configuration (activation of the electrode tip and a single directional contact at the next higher level of the electrode) achieved an accuracy of 13∘, while the horizontal electrode configuration (activation of two adjacent directional contacts at the same electrode level) achieved the best accuracy of 6∘. The accuracy of orientation detection of the DBS electrode depends on the change in spatial distribution of the magnetic field with the rotation of the electrode along its own axis. In the vertical configuration, rotation of the electrode has a small effect on the magnetic field distribution, while in the diagonal or horizontal configuration, electrode rotation has a significant effect on the magnetic field distribution.Significance.Our work suggests that in order to determine rotational orientation of a DBS electrode using MEG, horizontal configuration should be used as it provides the most accurate results compared to other possible configurations.


Asunto(s)
Estimulación Encefálica Profunda , Magnetoencefalografía , Electrodos , Fantasmas de Imagen , Rotación
3.
Sensors (Basel) ; 21(7)2021 Apr 04.
Artículo en Inglés | MEDLINE | ID: mdl-33916581

RESUMEN

Correct position and orientation of a directional deep brain stimulation (DBS) electrode in the patient's brain must be known to fully exploit its benefit in guiding stimulation programming. Magnetoelectric (ME) sensors can play a critical role here. The aim of this study was to determine the minimum required limit of detection (LOD) of a ME sensor that can be used for this application by measuring the magnetic field induced by DBS. For this experiment, a commercial DBS system was integrated into a head phantom and placed inside of a state-of-the-art Superconducting Quantum Interference Device (SQUID)-based magnetoencephalography system. Measurements were performed and analyzed with digital signal processing. Investigations have shown that the minimum required detection limit depends on various factors such as: measurement distance to electrode, bandwidth of magnetic sensor, stimulation amplitude, stimulation pulse width, and measurement duration. For a sensor that detects only a single DBS frequency (stimulation frequency or its harmonics), a LOD of at least 0.04 pT/Hz0.5 is required for 3 mA stimulation amplitude and 60 µµs pulse width. This LOD value increases by an order of magnitude to 0.4 pT/Hz0.5 for a 1 kHz, and by approximately two orders to 3 pT/Hz0.5 for a 10 kHz sensor bandwidth. By averaging, the LOD can be reduced by at least another 2 orders of magnitude with a measurement duration of a few minutes.

4.
J Neural Eng ; 18(2)2021 03 02.
Artículo en Inglés | MEDLINE | ID: mdl-33503598

RESUMEN

Objective.The aim of the present study was to investigate the accuracy of localization and rotational orientation detection of a directional deep brain stimulation (DBS) electrode using a state-of-the-art magnetoencephalography (MEG) scanner.Approach.A directional DBS electrode along with its stimulator was integrated into a head phantom and placed inside the MEG sensor array. The electrode was comprised of six directional and two omnidirectional contacts. Measurements were performed while stimulating with different contacts and parameters in the phantom. Finite element modeling and fitting approach were used to compute electrode position and orientation.Main results.The electrode was localized with a mean accuracy of 2.2 mm while orientation was determined with a mean accuracy of 11∘. The limitation in detection accuracy was due to the lower measurement precision of the MEG system. Considering an ideal measurement condition, these values represent the lower bound of accuracy that can be achieved in patients.Significance.However, a future magnetic measuring system with higher precision will potentially detect location and orientation of a DBS electrode with an even greater accuracy.


Asunto(s)
Estimulación Encefálica Profunda , Magnetoencefalografía , Animales , Decapodiformes , Estimulación Encefálica Profunda/métodos , Electrodos , Humanos , Magnetoencefalografía/métodos , Fantasmas de Imagen
5.
Parkinsonism Relat Disord ; 66: 62-67, 2019 09.
Artículo en Inglés | MEDLINE | ID: mdl-31327629

RESUMEN

INTRODUCTION: Late-onset essential tremor is characterised by shorter life expectancy and more advanced aging parameters and may therefore be an 'aging-related' tremor. Brainstem functions involved in pupillary responses are hypothesized to reflect such earlier aging. The pupillary light response (PLR) and a task evoked pupillary response (TEPR) were used to test this hypothesis in same-aged patients with early onset (EOET) and late onset (LOET) essential tremor and healthy controls. SUBJECTS AND METHODS: Age related changes of the PLR and TEPR during the paced auditory serial addition test (PASAT) were tested in 57 normal subjects. Subsequently, 13 patients with LOET and 16 patients with EOET were compared with 15 age matched healthy controls. Standard parameters of PLR were recorded, amongst others the time to maximum acceleration of the PLR (T1) and the time to maximum velocity (T2). The TEPR was determined during the PASAT as the percentage change in pupil size (PCPS). Data were analysed with ANOVA and post-hoc testing. RESULTS: In normal subjects the pupil diameter, latency, maximum acceleration/velocity and percentage amplitude were correlated with age. Latency of the pupillary light response was significantly longer in LOET compared to controls and EOET while no differences were found between EOET and controls. The TEPR showed no significant differences between the three groups. CONCLUSION: LOET showed a prolonged latency of the PLR compared to EOET possibly indicating premature aging or rather pathophysiological differences on brainstem level. This study further supports the hypothesis of abnormal aging in LOET.


Asunto(s)
Tronco Encefálico/fisiología , Temblor Esencial/fisiopatología , Reflejo Pupilar/fisiología , Adulto , Edad de Inicio , Anciano , Anciano de 80 o más Años , Cognición/fisiología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estimulación Luminosa , Pensamiento/fisiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...