Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 103
Filtrar
1.
Clin Exp Nephrol ; 2024 Jun 15.
Artículo en Inglés | MEDLINE | ID: mdl-38879735

RESUMEN

BACKGROUND: Although vaccination has been reported to reduce the morbidity and severity of COVID-19 infection in patients with kidney disease, gross hematuria is frequently reported following vaccination in patients with IgA nephropathy. We investigated the frequency of gross hematuria following COVID-19 vaccination and its effect on renal function in IgA nephropathy patients. METHODS: Adverse reactions after two or more COVID-19 vaccine doses were investigated in 295 IgA nephropathy patients attending Osaka Cty general hospital from September 2021 to November 2022. We compared differences in background characteristics and other adverse reactions between groups with and without gross hematuria after vaccination, and examined changes in renal function and proteinuria. RESULTS: Twenty-eight patients (9.5%) had gross hematuria. The median age of patients with and without gross hematuria was 44 (29-48) and 49 (42-61) years, respectively, indicating a significant difference. The percentage of patients with microscopic hematuria before vaccination differed significantly between those with (65.2%) and without (32%) gross hematuria. Adverse reactions, such as fever, chills, headache and arthralgia, were more frequent in patients with gross hematuria. There was no difference in renal functional decline after approximately 1 year between patients with and without gross hematuria. We also found no significant changes in estimated glomerular filtration rate or proteinuria before and after vaccination in the gross hematuria group. However, some patients clearly had worsening of renal function. CONCLUSIONS: While COVID-19 vaccination is beneficial, care is required since it might adversely affect renal function in some patients.

2.
Hypertens Res ; 2024 May 17.
Artículo en Inglés | MEDLINE | ID: mdl-38760521

RESUMEN

Renal denervation has attracted attention as a novel antihypertensive treatment for hypertensive patients who are poorly controlled by medicine. Clinical studies have shown the antihypertensive effects of renal denervation in patients with treatment-resistant hypertension. However, renal denervation potentially has other beneficial effects, such as improving glucose metabolism and cardioprotection beyond its antihypertensive effects. In this mini-review article, we summarize and discuss the effects of renal denervation on proteinuria, albuminuria, and renal function based on the recent findings of clinical studies, and review the renoprotective effects of renal denervation.

4.
Case Rep Cardiol ; 2024: 3426669, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38406208

RESUMEN

Femoral arteriovenous access is most commonly used in endovascular diagnosis and treatment. Complications arising during femoral arteriovenous access include hematoma, retroperitoneal hemorrhage, pseudoaneurysm, and arteriovenous fistula. A 66-year-old woman diagnosed with paroxysmal atrial fibrillation was treated with catheter ablation. This patient had a high femoral artery bifurcation, and we punctured the femoral vein by the conventional Merkmal method, which led to a femoral vein puncture through the deep femoral artery. The next day, echography revealed a pseudoaneurysm communicating with the deep femoral artery. We performed a thrombin injection without complication, and the pseudoaneurysm was occluded. However, echography three days after thrombin embolization showed a recurrence of the pseudoaneurysm and an arteriovenous fistula connecting to the common femoral vein. The first choice for the treatment of pseudoaneurysms and arteriovenous fistula is surgical treatment, but in addition to the lack of vascular surgery in our hospital, the patient did not want an invasive treatment and strongly preferred to be treated with a catheter. We performed endovascular treatment by VIABAHN® stent graft insertion. VIABAHN® stent graft was implanted at the deep femoral artery, and the patient was discharged without complications. VIABAHN® stent graft placement in the deep femoral artery sealed the entrance of the pseudoaneurysm and the arteriovenous fistula at once, which simultaneously treated both the pseudoaneurysm and AV fistula, and helped avoid the use of an invasive surgical procedure.

6.
Artículo en Inglés | MEDLINE | ID: mdl-36914159

RESUMEN

BACKGROUND: The development of minimally invasive endoscopic neurosurgery has enabled widespread application of endoscopic surgery via the ipsilateral transfrontal approach for putaminal hematoma evacuation. However, this approach is unsuitable for putaminal hematomas that extend into the temporal lobe. We adopted the endoscopic trans-middle temporal gyrus approach, instead of the conventional surgical approach, for the management of these complicated cases and determined its safety and feasibility. METHODS: Twenty patients with putaminal hemorrhage underwent surgical treatment at the Shinshu University Hospital between January 2016 and May 2021. Of these, two patients with left putaminal hemorrhage that extended into the temporal lobe underwent surgical treatment using the endoscopic trans-middle temporal gyrus approach. The procedure entailed the use of a thinner transparent sheath to reduce the technique's invasiveness, a navigation system to determine the location of the middle temporal gyrus and the sheath's trajectory, and an endoscope with a 4K camera for higher image quality and utility. The sylvian fissure was compressed superiorly using our novel "port retraction technique" (i.e., by tilting the transparent sheath superiorly) to avoid damage to the middle cerebral artery and Wernicke's area. RESULTS: The endoscopic trans-middle temporal gyrus approach allowed sufficient hematoma evacuation and hemostasis under endoscopic observation without any surgical complexities or complications. The postoperative course was uneventful in both patients. CONCLUSION: The endoscopic trans-middle temporal gyrus approach for putaminal hematoma evacuation helps avoid damage to normal brain tissue, which could result from the wide range of motion of the conventional technique, particularly when the hemorrhage extends to the temporal lobe.

8.
Interv Neuroradiol ; : 15910199231201517, 2023 Sep 11.
Artículo en Inglés | MEDLINE | ID: mdl-37697723

RESUMEN

We read with great interest the paper titled "Transradial access with Simmons guiding catheter for carotid artery stenting: Feasibility and procedural complications in a single-center experience" by Muszynski et al. The authors concluded that a transradial carotid artery stenting (CAS) using a Glidesheath Slender 7F Introducer/7F Envoy Simmons 2 catheter system was feasible with a high procedural success rate and low access site complication rate. We completely agree with their conclusions. In this study, large-diameter sheaths were used. Large sheaths increase the risk of developing radial artery spasms. Interventionalists must be aware that radial artery spasm can not only require an access crossover, but can also cause severe access site complications, such as eversion or avulsion of the radial artery, catheter/sheath entrapment, and compartment syndrome. A 6F Simmons guiding sheath has a smaller outer diameter than the Glidesheath Slender 7F Introducer does, and it offers a large-bore working channel compatible with a 10-mm diameter Wallstent and Acculink. Transradial CAS with a 6F Simmons guiding sheath has previously yielded a high procedural success rate without serious access site complications. Nevertheless, we believe that a further decrease in the sheath diameter is required to safely perform transradial neurointerventions in more patients.

9.
J Neurosci ; 43(49): 8294-8305, 2023 12 06.
Artículo en Inglés | MEDLINE | ID: mdl-37429719

RESUMEN

Dopamine neurons (DANs) are extensively studied in the context of associative learning, in both vertebrates and invertebrates. In the acquisition of male and female Drosophila olfactory memory, the PAM cluster of DANs provides the reward signal, and the PPL1 cluster of DANs sends the punishment signal to the Kenyon cells (KCs) of mushroom bodies, the center for memory formation. However, thermo-genetical activation of the PPL1 DANs after memory acquisition impaired aversive memory, and that of the PAM DANs impaired appetitive memory. We demonstrate that the knockdown of glutamate decarboxylase, which catalyzes glutamate conversion to GABA in PAM DANs, potentiated the appetitive memory. In addition, the knockdown of glutamate transporter in PPL1 DANs potentiated aversive memory, suggesting that GABA and glutamate co-transmitters act in an inhibitory manner in olfactory memory formation. We also found that, in γKCs, the Rdl receptor for GABA and the mGluR DmGluRA mediate the inhibition. Although multiple-spaced training is required to form long-term aversive memory, a single cycle of training was sufficient to develop long-term memory when the glutamate transporter was knocked down, in even a single subset of PPL1 DANs. Our results suggest that the mGluR signaling pathway may set a threshold for memory acquisition to allow the organisms' behaviors to adapt to changing physiological conditions and environments.SIGNIFICANCE STATEMENT In the acquisition of olfactory memory in Drosophila, the PAM cluster of dopamine neurons (DANs) mediates the reward signal, while the PPL1 cluster of DANs conveys the punishment signal to the Kenyon cells of the mushroom bodies, which serve as the center for memory formation. We found that GABA co-transmitters in the PAM DANs and glutamate co-transmitters in the PPL1 DANs inhibit olfactory memory formation. Our findings demonstrate that long-term memory acquisition, which typically necessitates multiple-spaced training sessions to establish aversive memory, can be triggered with a single training cycle in cases where the glutamate co-transmission is inhibited, even within a single subset of PPL1 DANs, suggesting that the glutamate co-transmission may modulate the threshold for memory acquisition.


Asunto(s)
Drosophila , Olfato , Animales , Femenino , Masculino , Drosophila/fisiología , Olfato/fisiología , Dopamina/metabolismo , Neuronas Dopaminérgicas/fisiología , Penicilinas/metabolismo , Glutamatos , Sistema de Transporte de Aminoácidos X-AG/metabolismo , Ácido gamma-Aminobutírico/metabolismo , Cuerpos Pedunculados/metabolismo , Drosophila melanogaster/metabolismo
10.
Proc Natl Acad Sci U S A ; 120(32): e2221770120, 2023 Aug 08.
Artículo en Inglés | MEDLINE | ID: mdl-37523543

RESUMEN

Oceanic lithosphere moves over a mechanically weak layer (asthenosphere) characterized by low seismic velocity and high attenuation. Near mid-ocean ridges, partial melting can produce such conditions because of the high-temperature geotherm. However, seismic observations have also shown a large and sharp velocity reduction under oceanic plates at the lithosphere-asthenosphere boundary (LAB) far from mid-ocean ridges. Here, we report the effect of water on the seismic properties of olivine aggregates in water-undersaturated conditions at 3 GPa and 1,223 to 1,373 K via in-situ X-ray observation using cyclic loading. Our results show that water substantially enhances the energy dispersion and reduces the elastic moduli over a wide range of seismic frequencies (0.5 to 1,000 s). An attenuation peak that appears at higher frequencies (1 to 5 s) becomes more pronounced as the water content increases. If water exists only in the asthenosphere, this is consistent with the observation that the attenuation in the asthenosphere is almost constant over a wide frequency range. These sharp seismic changes at the oceanic LAB far from mid-ocean ridges could be explained by the difference in water content between the lithosphere and asthenosphere.

11.
World Neurosurg ; 178: 126-131, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37506842

RESUMEN

BACKGROUND: Aberrant right subclavian artery (ARSA) is a rare condition, but the most common anomaly of the aortic arch. Although neurointerventions via transradial access (TRA) are becoming increasingly popular worldwide, transradial carotid cannulation has been extremely challenging in patients with an ARSA. Herein, we present a case of ARSA-associated anterior communicating artery (ACoA) aneurysm that was successfully treated with a radial-specific 6F Simmons guiding sheath via left TRA. We also review the relevant literature. METHODS: A 68-year-old-woman who was diagnosed as having an ARSA-associated ACoA aneurysm underwent simple coiling via left TRA. After the 6F Simmons guiding sheath was engaged into the right common carotid artery using the pull-back-technique, transradial quadraxial system (6F Simmons guiding sheath/6F intermediate catheter/3.2F intermediate catheter/coil-delivery microcatheter) was implemented. RESULTS: Simple coiling of the aneurysm was successfully achieved without catheter kinking or system instability. The postprocedural course was uneventful. A follow-up magnetic resonance angiography showed no evidence of recanalization 1 years 9 months after the procedure. CONCLUSIONS: Transradial anterior circulation intervention has been rarely used for patients with an ARSA due to unfavorable catheter trajectory. Left TRA using the 6F Simmons guiding sheath is a useful treatment option to address anterior circulation interventions for patients with an ARSA. Preoperative diagnosis of ARSA is necessary for the application of our method.


Asunto(s)
Aneurisma , Anomalías Cardiovasculares , Femenino , Humanos , Adulto , Niño , Anciano , Arteria Radial/diagnóstico por imagen , Arteria Radial/cirugía , Arteria Subclavia/diagnóstico por imagen , Arteria Subclavia/cirugía , Arteria Subclavia/anomalías , Aneurisma/diagnóstico por imagen , Aneurisma/cirugía , Anomalías Cardiovasculares/complicaciones , Anomalías Cardiovasculares/diagnóstico por imagen
13.
World Neurosurg ; 177: 31-38, 2023 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-37268190

RESUMEN

BACKGROUND: Flow diverter (FD) treatment is a promising therapeutic strategy for intracranial aneurysms such as cavernous carotid aneurysms (CCAs). Direct cavernous carotid fistula (CCF) caused by delayed rupture of FD-treated CCAs has been reported, and endovascular therapy has been used in the literature. Surgical treatment is warranted for patients who have failed or are ineligible for endovascular treatment. However, no studies have evaluated surgical treatment to date. Here, this paper presents the first case of direct CCF due to delayed rupture of an FD-treated CCA managed with surgical internal carotid artery (ICA) trapping with bypass revascularization, in which the intracranial ICA with FD placement was successfully occluded with aneurysm clips. METHODS: A 63-year-old man with a diagnosis of large symptomatic left CCA underwent FD treatment. The FD was deployed from the supraclinoid segment of the ICA distal to the ophthalmic artery to the petrous segment of the ICA. Since angiography 7 months after the FD placement showed progressive direct CCF, left superficial temporal artery-middle cerebral artery bypass followed by ICA trapping was performed. RESULTS: The intracranial ICA proximal to the ophthalmic artery where the FD was placed was successfully occluded using two aneurysm clips. The postoperative course was uneventful. Follow-up angiography 8 months after the surgery confirmed complete obliteration of the direct CCF and CCA. CONCLUSIONS: The intracranial artery in which the FD was deployed was successfully occluded with two aneurysm clips. ICA trapping can be a feasible and useful therapeutic option to treat direct CCF caused by FD-treated CCAs.

14.
J Artif Organs ; 2023 Apr 29.
Artículo en Inglés | MEDLINE | ID: mdl-37120686

RESUMEN

Neuron-specific enolase (NSE) is one of the biomarkers used as an indicator of brain disorder, but since it is also found in blood cell components, there is a concern that a spurious increase in NSE may occur after cardiovascular surgery, where cardiopulmonary bypass (CPB) causes hemolysis. In the present study, we investigated the relationship between the degree of hemolysis and NSE after cardiovascular surgery and the usefulness of immediate postoperative NSE values in the diagnosis of brain disorder. A retrospective study of 198 patients who underwent surgery with CPB in the period from May 2019 to May 2021 was conducted. Postoperative NSE levels and Free hemoglobin (F-Hb) levels were compared in both groups. In addition, to verify the relationship between hemolysis and NSE, we examined the correlation between F-Hb levels and NSE levels. We also examined whether different surgical procedures could produce an association between hemolysis and NSE. Among 198 patients, 20 had postoperative stroke (Group S) and 178 had no postoperative stroke (Group U). There was no significant difference in postoperative NSE levels and F-Hb levels between Group S and Group U (p = 0.264, p = 0.064 respectively). F-Hb and NSE were weakly correlated (r = 0.29. p < 0.01). In conclusion, NSE level immediately after cardiac surgery with CPB is modified by hemolysis rather than brain injury, therefore it would be unreliable as a biomarker of brain disorder.

15.
Nagoya J Med Sci ; 85(1): 179-184, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-36923619

RESUMEN

Penetrating head injury is a relatively rare condition associated with high morbidity and mortality. Although the immediate treatment of penetrating head injury is needed, surgical strategies are varied based on the trajectory of the penetrating objects in the cranium. We present a case of 24-year-old man who sustained a transorbital penetrating injury caused by a wooden chopstick. Neuroimages revealed a linear lesion extending from the left intraorbital segment to the cavernous sinus passing through the superior orbital fissure. The foreign body was successfully removed via the transcranial approach without complications. A careful management based on the perioperative images and correct diagnosis is necessary to avoid unfavorable complications. Four cases of transorbital penetrating injuries have been previously reported, in which the foreign body penetrated through the superior orbital fissure and lodged in the cavernous sinus. The frontotemporal craniotomy with extradural approach can be a useful option to remove foreign bodies around the cavernous sinus regions.


Asunto(s)
Seno Cavernoso , Cuerpos Extraños , Traumatismos Penetrantes de la Cabeza , Masculino , Humanos , Adulto Joven , Adulto , Traumatismos Penetrantes de la Cabeza/diagnóstico por imagen , Traumatismos Penetrantes de la Cabeza/cirugía , Traumatismos Penetrantes de la Cabeza/complicaciones , Seno Cavernoso/diagnóstico por imagen , Seno Cavernoso/cirugía , Seno Cavernoso/lesiones , Cuerpos Extraños/diagnóstico por imagen , Cuerpos Extraños/cirugía , Cuerpos Extraños/complicaciones , Órbita/diagnóstico por imagen , Órbita/cirugía , Órbita/lesiones , Craneotomía
16.
World Neurosurg ; 173: 88-93, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-36842527

RESUMEN

OBJECTIVE: Stent-assisted coiling (SAC) using the jailing technique is a well-established treatment for wide-neck intracranial aneurysms. However, low-volume packing, which is a key factor for aneurysm recanalization, can occur in patients with irregularly shaped aneurysms. We have devised a real-time monitoring system for aneurysm catheterization that allows the intentional placement of the jailed coil-delivery microcatheter and deployed stent, referred to as the "scope" technique. Herein, we present a case of irregularly shaped anterior communicating artery (ACoA) aneurysm successfully treated with SAC using this technique. METHODS: A 72-year-old woman diagnosed with an unruptured wide-neck ACoA aneurysm that was eccentric to the parent ACoA and overhanging posteriorly underwent SAC using this technique. Bilateral transradial quadraxial systems (6-Fr Simmons guiding sheath/6-Fr intermediate catheter/3.2-Fr intermediate catheter/microcatheter) were established via right and left internal carotid artery. The stent-delivery microcatheter was advanced into the left A2 via the right A1, leaving a 0.014″ microguidewire for visualization under fluoroscopic guidance. To place the coil-delivery microcatheter in the middle of the aneurysm after stent deployment, the coil-delivery microcatheter was cannulated into the aneurysm via the left A1, intendedly through the posterior side of the stent-delivery microcatheter in the down-the-barrel view of the parent ACoA (the scope technique). RESULTS: After stent deployment, SAC of the aneurysm was successfully achieved. CONCLUSIONS: Using this technique, the coil-delivery microcatheter was cannulated into the aneurysm, while monitoring its positional relationship with the stent-delivery microcatheter in real time. This technique is a useful treatment option for irregularly shaped and wide-neck aneurysms.


Asunto(s)
Embolización Terapéutica , Aneurisma Intracraneal , Femenino , Humanos , Adulto , Niño , Anciano , Aneurisma Intracraneal/diagnóstico por imagen , Aneurisma Intracraneal/cirugía , Resultado del Tratamiento , Embolización Terapéutica/métodos , Stents , Cateterismo/métodos , Angiografía Cerebral/métodos
18.
Brain Sci ; 13(1)2023 Jan 09.
Artículo en Inglés | MEDLINE | ID: mdl-36672096

RESUMEN

An encephalocele is a pathological brain herniation caused by osseous dural defects. Encephaloceles are known to be regions of epileptogenic foci. We describe the case of a 44-year-old woman with refractory epilepsy associated with a frontal skull base encephalocele. Epilepsy surgery for encephalocele resection was performed; however, the epilepsy was refractory. A second epilepsy surgery for frontal lobectomy using intraoperative electroencephalography was required to achieve adequate seizure control. Previous reports have shown that only encephalocele resection can result in good seizure control, and refractory epilepsy due to frontal lobe encephalocele has rarely been reported. To the best of our knowledge, this is the first report of frontal encephalocele plus epilepsy in which good seizure control using only encephalocele resection was difficult to achieve. Herein, we describe the possible mechanisms of encephalocele plus epilepsy and the surgical strategy for refractory epilepsy with encephalocele, including a literature review.

19.
Br J Neurosurg ; 37(6): 1786-1791, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-33851560

RESUMEN

BACKGROUND: The prognosis for spinal artery aneurysms associated with spinal cord arteriovenous malformations (AVMs) is poor because of the high rupture rate of aneurysms. However, endovascular treatment remains technically difficult because the catheter system must be constructed via the small-caliber anterior spinal artery (ASA) or posterior spinal artery (PSA), which feeds functionally eloquent spinal cord. A 2.6F Carnelian HF-S microcatheter (Tokai Medical Products, Aichi, Japan) has been specifically designed to assist a 1.6F Carnelian MARVEL S microcatheter (Tokai Medical Products) as a small-profile 'platform catheter' close to the target lesion. Here we present a prenidal ASA aneurysm treated using a 2.6F Carnelian HF-S microcatheter as an intraspinal canal platform catheter and review related literature. CASE PRESENTATION: A 50-year-old man presented with a subarachnoid haemorrhage due to cervical spinal cord AVM. Diagnostic vertebral angiography revealed the AVM supplied by the PSA originated from the right C2 segmental artery and ASA arising from the right V4 segment. Superselective angiography for each feeder was achieved through a 2.6F Carnelian HF-S microcatheter, and a prenidal ASA aneurysm was diagnosed, which was clinically consistent with haemorrhagic origin. A 1.6F Carnelian MARVEL S microcatheter was cannulated into the aneurysm through the 2.6F Carnelian HF-S microcatheter positioned at the ASA. The aneurysm coiling was successfully performed without system instability or periprocedural complications. CONCLUSIONS: Only a few cases have described endovascular treatment for spinal artery aneurysms. To date, no reports have been published regarding the use of an intraspinal canal platform catheter to treat spinal artery aneurysms. A 2.6F Carnelian HF-S microcatheter served as a useful intraspinal canal platform catheter for coil embolization of the ASA aneurysm. This system can provide excellent accessibility and controllability for endovascular treatment of spinal artery lesions.


Asunto(s)
Aneurisma , Malformaciones Arteriovenosas , Embolización Terapéutica , Aneurisma Intracraneal , Hemorragia Subaracnoidea , Masculino , Humanos , Persona de Mediana Edad , Aneurisma/terapia , Malformaciones Arteriovenosas/complicaciones , Malformaciones Arteriovenosas/diagnóstico por imagen , Malformaciones Arteriovenosas/cirugía , Hemorragia Subaracnoidea/diagnóstico por imagen , Hemorragia Subaracnoidea/etiología , Hemorragia Subaracnoidea/cirugía , Arteria Vertebral/diagnóstico por imagen , Arteria Vertebral/cirugía , Médula Espinal/diagnóstico por imagen , Médula Espinal/cirugía , Embolización Terapéutica/efectos adversos , Aneurisma Intracraneal/complicaciones
20.
J Neuroradiol ; 50(2): 217-222, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-35752296

RESUMEN

Intracranial angioplasty/stenting is a treatment option for patients with symptomatic intracranial atherosclerotic disease refractory to aggressive medical treatment. However, it carries a risk of procedure-related embolism as well as reperfusion hemorrhage and in-stent thrombosis. We have devised a new embolic protection system which can achieve both total ipsilateral internal carotid artery (ICA) embolic protection and real-time visualization of the target lesion during endovascular revascularization of intracranial atherosclerotic disease below the carotid T junction. Herein, we describe a case of medically refractory symptomatic intracranial atherosclerotic ICA stenosis successfully treated with this method.


Asunto(s)
Estenosis Carotídea , Arteriosclerosis Intracraneal , Humanos , Estenosis Carotídea/terapia , Succión , Angioplastia/efectos adversos , Arteria Carótida Interna , Angiografía , Stents , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...