Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Front Oncol ; 12: 868216, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36531073

RESUMEN

Background and objective: The pathological type of non-small cell lung cancer is considered to be an important factor affecting the treatment and prognosis. The purpose of this study was to investigate the diagnostic value of spectral parameters of dual-layer spectral detector computed tomography (DLCT) in determining efficacy to distinguish adenocarcinoma (AC) and squamous cell carcinoma (SC), and their combined diagnostic efficacy was also analyzed. Methods: This is a single-center prospective study, and we collected 70 patients with lung SC and 127 patients with lung AC confirmed by histopathological examination. Morphological parameters, plain scan CT value, biphasic enhanced CT value, and spectral parameters were calculated. The diagnostic efficiency of morphological parameters, spectral parameters, and spectral parameters combined with morphological parameters was obtained by statistical analysis. Results: In univariate analysis, seven morphological CT features differed significantly between SC and AC: tumor location (distribution), lobulation, spicule, air bronchogram, vacuole sign, lung atelectasis and/or obstructive pneumonia, and vascular involvement (all p < 0.05). In the arterial phase and the venous phase, the spectral parameters of AC were higher than those of SC (AP-Zeff: 8.07 ± 0.23 vs. 7.85 ± 0.16; AP-ID: 1.41 ± 0.47 vs. 0.94 ± 0.28; AP-NID: 0.13 ± 0.04 vs. 0.09 ± 0.03; AP-λ: 3.42 ± 1.10 vs. 2.33 ± 0.96; VP-Zeff: 8.26 ± 0.23 vs. 7.96 ± 0.16; VP-ID: 1.18 ± 0.51 vs. 1.16 ± 0.30; VP-NID: 0.39 ± 0.13 vs. 0.29 ± 0.08; VP-λ: 4.42 ± 1.28 vs. 2.85 ± 0.72; p < 0.001). When conducting multivariate analysis combining CT features and DLCT parameters with the best diagnostic efficacy, the independent predictors of AC were distribution on peripheral (OR, 4.370; 95% CI, 1.485-12.859; p = 0.007), presence of air bronchogram (OR, 5.339; 95% CI, 1.729-16.484; p = 0.004), and presence of vacuole sign ( OR, 7.330; 95% CI, 1.030-52.184; p = 0.047). Receiver operating characteristic curves of the SC and AC showed that VP-λ had the best diagnostic performance, with an area under the curve (AUC) of 0.864 and sensitivity and specificity rates of 85.8% and 74.3%, respectively; the AUC was increased to 0.946 when morphological parameters were combined, and sensitivity and specificity rates were 89.8% and 87.1%, respectively. Conclusion: The quantitative parameters of the DLCT spectrum are of great value in the diagnosis of SC and AC, and the combination of morphological parameters and spectral parameters is helpful to distinguish SC from AC.

2.
Quant Imaging Med Surg ; 12(9): 4601-4611, 2022 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-36060598

RESUMEN

Background: It is difficult to distinguish the pathological grade of lung adenocarcinoma (LUAD) with traditional computed tomography (CT). The aim of this study was to assess tumor differentiation by dual-layer spectral detector CT combined with morphological parameters. Methods: In this prospective study, a total of 67 patients with pathologically diagnosed LUAD were enrolled: 39 patients in the well- and moderately-differentiated group (14 and 25 patients, respectively) and 28 patients in the poorly-differentiated group. Morphological parameters, non-enhanced CT number, double-enhanced CT number, effective atomic number, monoenergetic CT images (40 and 70 keV), iodine density, and thoracic aorta iodine density of tumors were measured. The slope of the spectral curve and normalized iodine density were calculated. The diagnostic efficiency of the spectral parameters alone, and the combined spectral and morphological parameters were obtained by statistical analysis. Results: The morphological signs of LUAD (the vessel convergence sign, bronchus encapsulated air sign, and liquefactive necrosis) were higher in the poorly-differentiated group than in the well-moderately-differentiated group (57.1% vs. 30.8%, 40.0%; 60.7% vs. 28.2%, 32.0%; 64.3% vs. 28.2%, 24.0%; all P<0.05). There were significant differences in normalized iodine density (arterial phase: 0.10±0.04 vs. 0.12±0.05, 0.13±0.04; venous phase: 0.31±0.07 vs. 0.39±0.17, 0.40±0.17) among the poorly-differentiated group and moderately-differentiated group as well as the well-differentiated group (all P<0.05). Receiver operating characteristic (ROC) curves of the poorly-differentiated group and well-moderately-differentiated group showed that the normalized iodine density had the best diagnostic efficiency in the arterial phase, with an area under the curve (AUC) of 0.817, sensitivity of 92.9%, and specificity of 82.1% (P<0.001). The AUC increased to 0.916 when the morphological parameters were included, and sensitivity and specificity were 96.4% and 82.1% (P<0.001), respectively. Conclusions: The parameters of dual-layer spectral detector CT can help discriminate the pathological grade of LUAD. Among the spectral parameters, the normalized iodine density in the arterial phase has the best diagnostic efficiency, and the combination of spectral and morphological parameters improves the pathological grading of LUAD.

3.
Materials (Basel) ; 13(6)2020 Mar 17.
Artículo en Inglés | MEDLINE | ID: mdl-32192105

RESUMEN

A novel method involving the effect of thermal contact resistance (TCR) was proposed using a plane heat source smaller than the measured samples for improving measurement accuracy of the simultaneous determination of in-plane and cross-plane thermal conductivities and the volumetric heat capacity of anisotropic materials. The heat transfer during the measurement process was mathematically modeled in a 3D Cartesian coordinate system. The temperature distribution inside the sample was analytically derived by applying Laplace transform and the variables separation method. A multiparameter estimation algorithm was developed on the basis of the sensitivity analysis of the parameters to simultaneously estimate the measured parameters. The correctness of the algorithm was verified by performing simulation experiments. The thermophysical parameters of insulating materials were experimentally measured using the proposed method at different temperatures and pressures. Fiber glass and ceramic insulation materials were tested at room temperature. The measured results showed that the relative error was 1.6% less than the standard value and proved the accuracy of the proposed method. The TCRs measured at different pressures were compared with those obtained using the steady-state method, and the maximum deviation was 8.5%. The thermal conductivity obtained with the contact thermal resistance was smaller than that without the thermal resistance. The measurement results for the anisotropic silica aerogels at different temperatures and pressures revealed that the thermal conductivity and thermal contact conductance increased as temperature and pressure increased.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...